HomeMy WebLinkAboutNCG551733_Contractor Inspection_20220701Name and Address of System Inspector: McFarland Septic 6801 Mount Hermon Church Road Durham, NC 27705 (919) 383-1015 Inspection Date: 7/1/2022 Service Call County System Durham Classification & Type Surface Drip Sub -Surface Drip ❑ Spray System ❑ Surface Discharge �1 Name and Address of Owner: Paul Mangen 5234 Summit Ridge Dr Durham, NC 27712 Location of System: 5234 Summit Ridge Dr Durham, NC 27712 S = Satisfactory, M = Marginal, X = Unsatisfactory, N = Not Evaluated, NA = Not Applicable SEPTIC TANK Odors? Tank risers accessible? Signs of infiltration? Tanks and access structurally sound? 5 Sanitary tee(s) in good condition? 5 Effluent filter cleaned? 5 Effluent filter in good condition? 5 5 5 5 Septic Tank Water Depth Septic Tank needs pumping? Yes No Water Meter Reading: N/A Sludge Scum Level Level 8" 1" 48" x EFFLUENT DOSING STATION Tank riser height? Signs of infiltration? Required pumps present & operating properly? High water alarm operating properly? Floats, pipes, valves, disconnects in good condition? Control panel enclosure/components in good condition? Effluent appears clear and free of solids? Rain sensor working properly? Pump Readings: Pump Spin Filter Flush Zone 1 Zone 2 Zone 3 Zone 4 Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: Elapsed Time: 127.9 NA NA NA NA NA NA S S 5 5 5 5 5 NA Events 1571 Events Events Events Alarm Events: NA Events Secondary Count: NA Events Power Failure: NA Events Timer: On: NA Off: NA HEADWORKS Vortex filter in good condition? Vortex filter manually flushed? Valves in good condition? Valves manually flushed? Pressure Readings: Pre -filter: Post -filter: Drainfield: Any visible leaks? Air vent in good condition? #1 NA NA NA NA NA NA NA NA NA #2 NA #3 NA #4 NA Overall Condition? NA GROUND ABSORPTION FIELDS Odors? S Rainfall in last 3 days? Yes n No No evidence of effluent surfacing? NA Surface water being effectively diverted away? S Line cover & vegetation cover maintained properly? S Protected from traffic, destructive uses? S Distribution devices in good working condition? S Repair area properly reserved, maintained? NA Drainfield pressure (at air vent): #1 NA #2 NA #3 NA #4 NA Flow Meter Reading: NA Pre -Treatment Station: Advantex Media in good condition? S Media container in good condition? S Ponding on surface of media? S Excessive scum build up on surface? S Equal spray patterns? S Any orifices clogged? S Piping network flushed? S Does media need cleaning? S Squirt Height: Observed: NA Adjusted: NA Processing Tank: Tank Risers accessible? S Signs of infiltration? S Tanks & access structurally sound? S Effluent appears clear and free of solids? S Required pumps present & operating properly? S High water alarm operating properly? S Floats, pipes, valves, disconnects in good condition? S Control Panel enclosure/components in good condition? S Telemetry working properly? S RSV in good condition & operating properly? S Pump Readings: Elapsed: 2061.8 Events: 53293 Alarm Events: 0 Timer Settings: On: 0.8 min Off: 14.2 min Sludge Scum Level: 1" Level: Lt. UV Disinfection Station: Basin Riser accessible? S Signs of infiltration? S Electrical components in good condition? S Any leaks? S Unit in good condition? S Intensity level: S Does bulb need replacing? S Cleaned quartz sleeve? S Any Alarms? S 0.38Amps Changed UV during ORC visit. RECOMMENDATIONS TO OWNER: 1.Changed UV Bulb during ORC visit. COMPLIANCE STATUS: COMPLIANT N NON -COMPLIANT 4(- -ze SIGNATURE OF "ORC"