Loading...
HomeMy WebLinkAboutSW3220304_Response To Comments_20220629(Z) Colelenest&Stone BOLTON & MENK,INC. June 28, 2022 Mr. Jim Farkas NCDEQ Division of Energy, Mineral & Land Resources 512 N. Salisbury Street, Office 640E Raleigh, NC 27604 RE: 4773 —Aldi East Spencer In -bound Traffic Improvements Stormwater Permit No. SW3220304 Dear Jim: South Tryon Street, Suite 1400 Charlotte, NC 28202 Office: 704-376-1555 colejeneststone.com The following responses are offered in connection with the permit review comment letter dated June 8, 2022, for the referenced project: Comment 1.a.i — Overland flow from parking area The subject parking area has been re -graded to reduce the overland flow path to <150 LF. Comment Lb — Pipe network around the proposed dispatch building The pipe network has been eliminated in favor of a graded swale with culverts under the sidewalk areas and the roof drain leaders are indicated to outlet to the swale where possible or tie to the sidewalk culvert where they directly intersect. Comment 1.c — Pipe network crossing the inbound traffic lanes Additional side swales at the driveway fill slope have been added to direct as much flow away from the pipe network as possible. The pipe network at the driveway low point is retained to convey drainage under the pavement and down the adjacent fill slope to a stabilized outlet at the base of slope (Drainage Structures STCB-2 to HW-1). This drainage system will collect approximately 4.2 acres of drainage area with an associated 10-year discharge of approximately 26.9 cfs. Accordingly, a pipe is used to control the drainage and maintain stable slope conditions. Approximately 500 LF of vegetated outfall swale exists beyond the toe of slope to the downstream discharge point at the property line. Comment 1.d —Trench drain at loading dock Comment acknowledged. The trench drain is retained. Comment 2 —Surface water areas Surface water areas and associated buffers have been noted on Sheet C-403. The surface water areas have been deducted from the property area total for purposes of density calculations on the permit application and Supplement- EZ form. Note that the pond area indicated on the USGS map no longer exists so has not been included in the surface water deduction. Comment 3 — Drainage areas The drainage areas in Section IV 10 of the permit application have been converted to square feet. Comment 4 — Manning s n-values The Manning's n-value for all ditch calculations has been adjusted to 0.045, representative of a short grass lining. Comment 5 — Supplement-EZ Form Corrections to the Supplement-EZ Form have been made as indicated. Respectfully submitted, R. Todd Fisher, PE Director of Civil Engineering 00000.00 1 June 28, 2022