HomeMy WebLinkAboutNCC222180_Site Plan or Location Map_20220622SITE PLAN
FOR
BURCH BROTHERS FLOORING
CLEVELAND TOWNSHIP -JOHNSTON COUNTY, NC
ENGINEER
DALTON ENGINEERING AND ASSOCIATES, P. A.
446 EAST MAIN STREET P.O. BOX 426
CLAYTON, NC 27520 CLAYTON, NC 27528
(919) 550-4740 - FAX (919) 550-4741
INDEX TO DRAWINGS
SHEET 1..... COVER SHEET
SHEET 2..... EXISTING CONDITIONS SHEET
SHEET 3..... SITE LAYOUT SHEET
SHEET 4..... DETAIL SHEET
SHEET 5..... STORMWATER MANAGEMENT AND SEDIMENT AND EROSION CONTROL PLAN
SHEET 6..... SEDIMENT AND EROSION CONTROL DETAIL SHEET
SHEET 7..... SEDIMENT AND EROSION CONTROL DETAIL SHEET
ADDENDUM
NCG01 GROUND STABILIZATION AND MATERIALS HANDLING
NCG01 SELF -INSPECTION, RECORDKEEPING AND REPORTING
SURVEYOR
TRUE LINE SURVEYING, P. C.
205 WEST MAIN STREET
CLAYTON, NC 27520
(919) 359-0427
Dalton Engineering
and Associates, P. A.
OWNER / DEVELOPER
BURCH BROTHERS FLOORING
182 CLEVELAND CROSSING
SUITE 400
GARNER, NC 27529
(919) 615-0022
NOTES:
1. DURING THE COURSE OF THE REVIEW IT WAS NOTED THAT THE SITE MAY
HAVE IMPACTED A RIVER BASIN BUFFER ZONE AND/OR MAY REQUIRE THE
APPLICATION AND ISSUANCE OF PERMITS FOR STORMWATER MANAGEMENT
SYSTEMS. IT IS THE RESPONSIBILITY OF THE DEVELOPER/APPLICANT TO
CONFORM TO THE REGULATIONS OF GOVERNMENT AGENCIES WITH REGARD
TO MINIMIZING WATER QUALITY IMPACTS IN ADDITION TO THE DRAINAGE
REQUIREMENTS OF THE DIVISION OF HIGHWAYS. THIS REVIEW DOES NOT
IMPLY CONFORMITY TO LOCAL OR OTHER STATE GOVERNMENT REGULATIONS
NOR CONSTITUTE AN APPROVAL OF SUCH.
2. ALL OPEN END CROSS PIPES IN NON C.A.M.A. COUNTIES WILL BE BURIED
20% OF THEIR DIAMETER UP TO A MAXIMUM OF ONE FOOT AS THE BED
CONDITIONS ALLOW.
3. HEADWALLS ARE USED ON PIPES ABOVE OR EQUAL TO 36" IN DIAMETER,
USUALLY ON BOTH ENDS BUT ALWAYS ON THE INLET. FLARED END
SECTIONS ARE USED ON SMALLER PIPES.
4. ALL DRAINAGE STRUCTURES INCLUDING OUTFALL DITCHES OUTSIDE OF THE
PROPOSED RIGHT OF WAY ARE TO BE ENCLOSED WITHIN A PERMANENT
PUBLIC DRAINAGE EASEMENT.
5. ALL ROADWAY DITCHES MUST BE STABLE BEFORE ACCEPTANCE UPON THE
STATE SYSTEM FOR MAINTENANCE.
6. ALL SURVEY INFORMATION/DATA SHOWN, AND/OR REPRESENTED, IN THE
CONSTRUCTION DRAWINGS HAS BEEN PROVIDED BY A PROFESSIONAL LAND
SURVEYOR AND IS NOT THE WORK OF DALTON ENGINEERING AND
ASSOCIATES, P.A.
7. IT IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER TO PROVIDE
DRAWINGS TO THE VARIOUS UTILITY PROVIDERS, SUCH AS DUKE PROGRESS,
CENTURYLINK, SPECTRUM, PIEDMONT GAS, ETC.
8. THE FINAL PLAT WILL BE REQUIRED TO SHOW ALL DRAINAGE EASEMENTS,
RIPARIAN BUFFERS, JURISDICTIONAL WETLANDS AND FLOOD HAZARD AREAS.
\\ C
PRE
1 RY
NOT FORCONSTRU
�
///�-T.
III 41D11P� \\`
REVISION 001: ADDRESSED JOHNSTON COUNTY PUBLIC UTILITIES COMMENTS - 5/19/22