HomeMy WebLinkAboutNCG551012_Inspection_20220620DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
NORTH CAROLINA
Environmental Quality
June 20, 2022
Yolanda Platero-Cruz
5010 Glenn Road
Durham, NC 27704
Certified Mail # 7020 3160 0000 4115 3500 Return Receipt Requested
Subject: NOTICE OF VIOLATION
Tracking Number: NOV-2022-PC-0342
Compliance Evaluation Inspection
General NPDES Permit NCG550000
Certificate of Coverage NCG551012
Facility: 5010 Glenn Road // Durham County
Dear Ms. Platero-Cruz:
This letter serves as a Notice of Violation (NOV) of General NPDES Permit No. NCG550000,
Certificate of Coverage No. NCG551012, and North Carolina GS § 143-215.1(a). The following
deficiencies have been previously noted in prior inspection reports and were again noted during
this inspection: failure to provide effluent sampling results (noted in 2017); no chlorine tablets
were observed in the chlorinator and/or the permittee did not have the proper chlorine tablets
(noted in 2017). Within 30-days receipt of this letter, please submit a written response to this
office indicating the actions you will take or have taken to comply with or resolve these issues.
On April 22, 2022, Alys Hannum from the Raleigh Regional Office visited your single-family
residence wastewater treatment system to evaluate compliance with the subject General National
Pollution Discharge Elimination System (NPDES) Permit. No one was at home at the time of the
inspection. The inspector left a packet of information regarding Single Family Treatment
Systems and the requirements of the General Permit at the residence and requested a callback.
Osmar Soto's assistance after the inspection was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, pump tank, sub -surface sand
filter, tablet chlorinator with chlorine contact chamber, discharge pipe and a rip -rap apron for
post aeration.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551012 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as an unnamed tributary to Ellerbe Creek in the Neuse River Basin, in accordance with the
effluent limits and monitoring requirements established within the General Permit. The following
conditions were noted at your facility:
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
Yolanda Platero-Cruz, NCG551012
June 20, 2022
Page 2 of 3
• Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than
1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required. The
General NPDES Permit requires the permittee to retain records associated with sewage
disposal activities for a period of at least 5 years.
After the inspection, Osmar Soto provided documentation showing Forever Clean
Portable Toilets Inc. pumped out the septic tank on March 6, 2017 and again on June 10,
2022.
• Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine
tablets be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming pools. Part 1,
Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect
the tablet chlorinator weekly to ensure there is an adequate supply of tablets for
continuous and proper operation.
The inspector did not observe any chlorine tablets in the chlorinator. Please ensure the
correct type of tablets are used and maintained in the chlorinator as required by the
General NPDES Permit.
• Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the
effluent leaving his/her treatment system prior to discharge annually. Parameters to be
sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total
Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia -
Nitrogen, and Total Phosphorus.
After the inspection, you informed the inspector that the effluent has not been monitored
since 2017. Please collect a representative sample of the effluent, have it analyzed by a
certified commercial laboratory and submit the results to this office no later than
December 31, 2022. Failure to monitor the effluent discharge as required is a violation
of NPDES General Permit NCG550000.
dD_E
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
Yolanda Platero-Cruz, NCG551012
June 20, 2022
Page 3 of 3
• Discharge outlet location. The permittee is required to conduct a visual review of the
outfall location at least twice each year (one at the time of sampling) to ensure that no
visible solids or other obvious evidence of system malfunctioning is observed. Any
visible signs of a malfunctioning system shall be documented and steps taken to correct
the problem.
The discharge pipe was visible and accessible the day of the inspection. Please continue
to ensure the outlet is always visible/maintained and cleared of vegetation, soil and
leaves.
Division records indicate the required annual fee ($60 per year) due June 2, 2022, for the period
ending May 31, 2023, has been paid. There are no overdue fees for the subject COC.
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of three
years for inspection.
Within 30-days receipt of this letter, please submit a written response to this office indicating
the actions you will take or have taken to comply with or resolve the issues noted above.
If you have questions or comments about this inspection or the requirements to take corrective
action, please contact Alys Hannum at alys.hannum@ncdenr.gov, or by phone at 919-791-4255.
Sincerely,
Docu Signed by:
Flatiu-ssa, f. 14tiuta
B2916E6AB32144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
cc: RRO/SWP Files // Laserfiche
£D_E
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction
1
21IIIIII
671
Code
IN I 2 IL
NPDES yr/mo/day Inspection
I 3 I NCG551012 111 121 22/04/22 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIII IIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
I 70I3 I 711 1 72 I N I 73I 1 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES Dermit Number)
5010 Glenn Road
5010 Glenn Rd
Durham NC 27704
Entry Time/Date
10:OOAM 22/04/22
Permit Effective Date
21/08/10
Exit Time/Date
10:30AM 22/04/22
Permit Expiration Date
25/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Yolanda Platero-Cruz,5010 Glenn Rd Durham NC 27704///
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenar Self -Monitoring Progran
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Alys K Hannum
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
�Docusignedby: DWR/RRO WQ/919-791-4255/
6/17/2022 b
"-4C22170C5AA04F3...
Signature
of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
fliDocuSigned by:
iss 6/17/2022
B2916E6AB32144F...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
NPDES yr/mo/day
31 NCG551012 111 121 22/04/22
I17
Inspection Type
18LI
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
Permit: NCG551012
Inspection Date: 04/22/2022
Owner - Facility: 5010 Glenn Road
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ � ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Comment:
Sand Filters (Low rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Comment:
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
• ❑ ❑ ❑
❑ ❑ ❑ •
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ ❑ ❑
Are the tablets the proper size and type? • ❑ ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? ❑ ❑ ❑ •
Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ •
Comment:
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Yes No NA NE
❑ ❑ ❑ •
Page# 3
DocuSign Envelope ID: 803C594A-027D-4092-98FF-BD6DDC08402D
Permit: NCG551012
Inspection Date: 04/22/2022
Owner - Facility: 5010 Glenn Road
Inspection Type: Compliance Evaluation
Effluent Sampling
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: Homeowner has not sampled the effluent.
Yes No NA NE
❑ • ❑ ❑
Page# 4