HomeMy WebLinkAboutWQ0043531_Application (FTSE)_20220610State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: viCto04353 (. (m be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Yadkin Valley Sewer Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Federal ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ State/County 3 Municipal ❑ Other 3. Signature authority's name: Nicole Johnston per 15A NCAC 02T .0106(b) Title: Executive Director 4. Applicant's mailing address: 500 NC Hwy 268 W City: Elkin State: NC Zip: 28621- 5. Applicant's contact information: Phone number: (336) 835-9819- Email Address: nicote.johnston(riyvsa.org 1I. PROJECT INFORMATION: I. Project name: High Priority Collection System Rehabilitation 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000 and issued date: For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Surly 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.249304' Longitude: -80.842260' 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) 1I1. CONSULTANT INFORMATION: , I. Professional Engineer: Benjamin B. Thomas Firm: West Consultants, PLLC Mailing address: 405 S Sterling, St City: Morganton State: NC Zip: 28655- Phone number: (828) 522-4728 Email Address: bthomas License Number: 20757 rest-consultants.cont IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Yadkin Valley Sewer Authority WWTP Permit Number: NC0020567 Owner Name: Yadkin Valley Sewer Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Pennit Number(s): unknown Downstream (Receiving) Sewer Information: 8 inch El Gravity 0 Force Main 3. System Wide Collection System Permit Number(s) (if applicable): 1VQCS00376 Owner Name(s): Yadkin Valley Sewer Authority FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.01 I5(c) been attached? ❑ Yes ❑ No Z N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ® Residential (Leased) ❑ School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories 0 Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home 0 Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool/Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? 0 Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? 0 Yes ® No > If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(Q) Daily Design Flow alb No. of Units Flow N/A gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Told GPD a See 15A NCAC 02T .0I 14(b), (d), (e)(I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I SA NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. 0 Flow has already been allocated in Permit Number: Issuance Date: ® Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA Of Applicable) - 02T.0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 662 PVC 8 40 DIP ➢ Section II & Ili of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to tninimtmt slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)— 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Total number of pumps at the pump station: 3. Design Flow of the pump station: millions gallons per day (fine capacity) • This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the me hod of solids reduction per MDCPSFM Section 2.0IC.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - I5A NCAC 02T.0305(11)(I)(B): D Required for all pump stations •ivith an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day I5A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & ISA NCAC 02T .0305(Q): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? ISA NCAC 02T.0305(t) contains minimum separations that shall be provided for sewer systems: Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not Iisted below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HOW, or SB from normal , high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height t 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > If noncompliance with 02T.0305(f) or (g). see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A > Please provide supplementary information identifying the areas of non-conformance. > See the Division's draft separation requirements for situations where separation cannot be met. > No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No > This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? > Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0I05(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonnwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per ISA NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be,inspected by the permittee or its representative at least once every six -months and inspections documented per ISA NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project. the full technical review is required. 2. Professional Engineer's Certification: 1, Benjamin B. Thomas, attest that this application for the High Priority Collection System Rehabilitation (Professional Engineer's name from Application Gem 111.1.) (Project Name from Application Item 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version . Although other professionals may have`developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. J NOTE — In accordance with General Statutes I43-215.6A and 143 215.6B, any person who knowingly makes any false statement, representation, or Certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-cotnpliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) gaaavx3xs.. North Carolina Professional Engineer's seal, signature, and date: CAROL 3. Applicant's Certification per I5A NCAC 02T .0106(b): 1, Nicole Johnston, Executive Director, attest that this application for the High Priority Collection System Rehabilitation (Signature Authority Name from Application Item 13.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, andior criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215,6 \ and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: FORM: FTA 06-21 Page 5 of 5 CONSULTANTS MC June 7, 2022 405 South Sterling Street, Morganton, NC 28655 828 433 5661 / fax 828 433 5662 / info@west-consultants.com Water Quality Section Winston-Salem Regional Office NCDEQ 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Re: Yadkin Valley Sewer Authority High Priority Collection System Rehabilitation Project To Whom It May Concerti: The Fast -Track application submitted is for the subject project that proposes to install approximately 662 LF of PVC pipe and 40 LF of ductile iron pipe to replace approximately 702 LF of deteriorated 6" clay gravity sewers. Included in this submittal are the following: • Fast -Track Application (FTA 06-21) + Description of proposed work • USGS and Aerial Location Maps • Check for $480.00 Since no new flow is being added, a FTSE form was not completed. Please let me know if you have questions or comments. Thank you, WEST CONSULTANTS, PLLC Benjamin B. Thomas, PE bthomas@west-consultants.com PROJECT DESCRIPTION: Yadkin Valley Sewer Authority (YVSA) High Priority Collection System Rehabilitation Project Elkin, North Carolina SRP-W-0202 The project is located in the Towns of Elkin (Surry County). The YVSA maintains the sewer collection system in the towns of Elkin, Jonesville, and Ronda (Wilkes County). The primary purpose of the project is to address inadequate sewer piping and to address inflow and infiltration from aging sewer infrastructure that causes SSO's and subsequent NOV's. The project includes the following: New 8" PVC gravity sewer (662 LF) and ductile iron pipe (40 LF) to replace approximately 702 LF of 6" clay gravity sewers. All proposed gravity sewer pipe will be SDR 35 PVC or ductile iron pipe. The project also includes the rehabilitation of approximately 16,705 LF of 8" gravity sewer by cured -in - place pipe (CIPP) and various manhole and pipe defect rehab/repairs. Since no new flow is being added, a FTSE form was not completed. Letter of Transmittal WEST CONSULTANTS, PLLC Consulting Engineers and Surveyors 405 South Sterling Street Morganton, NC 28655 www.west-consultants.com Phone (828) 433-5661 Fax (828) 433-5662 To: NCDEQ WATER QUALITY SECTION WINSTON-SALEM REGIONAL OFFICE 450 W. HANES MILL ROAD SUITE 300 WINSTON-SALEM, NORTH CAROLINA 27105 (336) 776-9800 lune 8, 2022 CONSULTANTS ruc Attention: Winston-Salem Regional Office Re: Yadkin Valley Sewer Authority High Priority, CS Rehab Project Project ID: SRP-W-0202 Job Number: 21.056 ® _ r We are Sendin9,irou following: Enclosed ❑ Under Separate Cover via: [Type text here] the ❑ Shop Drawings 0 Prints Plans IR Other: f ❑ Copy of Letter 0 Change Order 0 Samples Application ❑ Total Quantity ❑ Reproducible 0 Specification Copi O Eer Ntlrttlser Description " r _ 1 riginal FTA (w/ check) - . av 1 Copy of FTA For Approval/Review ❑ For Your Use ❑ As Requested ofylo:w r Yadkin Valley Sewer Authority ❑ Approved as Submitted ❑ Resubmit copies for approval ❑ Approved as Noted ❑ Submit [#] copies for distribution ❑ Returned for Corrections 0 Return [#] corrected prints l�flat rvr1, Ron Lynn (828) 522-4724 la PROPOSED 8" PIPE REPLACEMENTS (TYP)...,____. USGS LOCATION MAP YADKIN VALLEY SEWER AUTHORITY HIGH PRIORITY COLLECTION SYSTEM REHABILITATION ELKIN, NC SCALE 1 "=400' AERIAL LOCATION MAP YADKIN VALLEY SEWER AUTHORITY HIGH PRIORITY COLLECTION SYSTEM REHABILITATION ELKIN, NC