HomeMy WebLinkAboutGW1-2022-05752_Well Construction - GW1_20220609 ji WELL CONSTRUCTION RECORDAGW-1 1.Well Contractor Information: 513"I_7 R 'm Alfred Kiesling Sr OM TO DE.SCRiPrIO\ Well Contractor Name �Ll ft. I fc. 2670-A 0 ft. NC Nell Contractor Certification Number B & K Well Drilling Inc FROM TO I D C.": R TEHC RUL o ft. 6 1/4' SDR-21 PVC Company Name FROM 1,0 DIAMETER THICKNE&; MAILKIAL 2.Well Construction Permit#: c It ft. List all applicable well colrMcdo,pen, e. L,fC*.Coturrv.Starr.VaHancc.err.) R. jfL I ft. 3.Well Use(check well use): Water Supply Well: FROM I TO DIAMETER SLOTSIZE T14ICKN MATERIAL OAgi I ft. 0-MunicipaYPublic ft. oGeothermal(Heating/cooling supply) 2<dential Water Supply(single) ft. fL zidenTial Water Supply(shared) 01ndustriaKominercial ORL Cirrigation oWells> 100,000GPD FROM TU KxTERLILL VKMACE3�`r METHOD&.0101J.m Nun-Water Supply Well: 0 fL 20 fL Benionite Pour ONMonitoring CJRccovcry ft. I ft. I i Injection R`ell: ft. ft. Groutidwater Remediation OAquifer Recharge O ClAquifer Storage and Recovery OSaliiiiry Barrier FROM TO MAT I ERIAL PLAC [ENT METHOD CAquifer Test oStormwater Drainage ft. I ClExperimenEal Technology OSubsidence Control OGeothermal(Closed Loop) OTracer FROM TO DESCRIPTION(color.bard eSsdt k ermt--izee.) CGeothermal(Heating(Cooliag Return) 00ther(e.Vlain under#21 Remarks) ft. S let 4.Date Well(s)Cowletm-:,jq [j.2 -W X9 ell rD# go R. Sa-Well Location: n,aA N 70fL FacilityloivneT Nam M Name Facility-tw-ni LLt4 Facility ,(irapplicable" ft. ft. /,S-2 cS, ll Uret.La, -LA 11 ft. ft. Physical.Address,City.and Zip county ?"cl Identification 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees. (ifw'cll field,one lat/long is sufficient) zZ.Cc to 'on: N -We e4v 6.ls(are)thewell(s): nPermanent or OTemporary S;=atA ofCaniied well Com Date rhcr rhe,:-Pll(s) C ine P ,ivOY4 .;5.4 NCj.00k.0J0ror 15.,,kC,4CO2C.020n _ '11. 7.Is this a repair to an existing well; CYes or !lNo �If riji ri ff this isa repair.fill nutkno"r we'll -`11677"lim'and explai,-.Me'an"Fil"r h" _1 recnrd has bect,17,ol-ided in:the v.ra of repair render#21 remarks section or on the back qfrjiwfibm. 23.Site diagram or additional well details: J U N Qj 2022 8.For Geoprobe/DFT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional we onstruction info (add'See Ovee iu Remarkt,13o--).You may al-af ach a itio construction.only I GW-1 is needed. Indicate TOTAL XLTMBER ofwcIls ,I In C� . ­Z-Ax. drilled- 1 24.SUBMITTAL INSTRUCTIONS D-NQ1BOG 9.Total well depth below land surface: SM (f ) Submit this GW-1 within 30 days of well completion per the following: For muldple arils lisr,di depila ifififferent(example-3,�.200'anef 2@1001 24a. For All Wells: Original form to Division of Water Resources (DA'R). 10.Static water level below top of casing:40 (ft-) Information Processing Unit,1617 MSC,Raleigh.NC 27699-1617 jfivtjfer Intl isabatvcasing.use 24b.For Iniection wells-.Copy to DWR_Underground Injection Control(IUQ 11.Borehole diameter:6 1/8 (in.) Program,1636 MSC,Raleigh.,NC 276 99-1 63 6 12.Well construction method:Air Rotary 124c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the -talled al healt h of (i.e.auger,rotary.cable.dirrect push,etc.) county en department .county wh in, FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100.000 GPD:Copy to D%A'R,CCPCUA Air Lift Pcrmit Pro.-n-arn.1611 MSC.Raleigh-N:7 27699-1611 13a.Yield(gpm) Method of test.• 13b.Disinfection type: Chlor. Tabs .kniount. 1 1/2 Lbs RcvisLd"-2019 Form GW-1 North Carolina Deliartracrit ofEni ironinenral Quality-Division of Warcr RcsoLn:cs