Loading...
HomeMy WebLinkAboutNC0026042_Correspondence_20070309NPDES DOCUMENT ! CANNINO COVER SHEET NC0026042 Robersonville WWTP NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Correspondence Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: March 9, 2007 This document is printed on reuse paper - 44 none airy content on the reYerse side 11/30/2009 14:41 2529469215 NCDENR DWO PAGE 03/07 THE WOOTEN COMPANY ENGINEERING PLANNING ARC fHI T E CTUR C I2n Nnrth Nov Avenn., Ralelrlx NC 27603-1123 919 828.0531 fax 910 834.3589 March 9, 2007 Ms. Kristin C. Jarman Wastewater Treatment Plant Consultant NCDWQ Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 Re: Comment Response to Compliance Evaluation Inspection Town of Robersonville Dear Ms. Jarman: RECEIVED ;';i;,Z 1 3 Z007 DWQ-WARO ticoo "o9Z On behalf of the Town of Robersonvillc, we are writing in response to your January 8, 2007 letter regarding the Compliance Evaluation Inspection held at the plant on 12/5/06. 1 understand that Mr. Willie Andrews with the Town submitted an initial response within the time frame requested and identified that The Wooten Company would be following up with additional comments which arc provided herein. In 1999 the Town implemented variable frequency drives for improved control of the existing 100 HP oxidation ditch aerators as part of a nutrient improvements project at the plant- These VFDs offered operational flexibility by allowing the aerator motor speed to vary up/down in response to maintaining the desired dissolved oxygen levels in the aeration zone of the treatment process. These improvements not only enhanced the plant process capabilities but also offered opportunity for significant electrical power savings. Recently the plant staff has experienced problems with both of the VFD units such that the plant currently operates the aerators at full speed without the aid of the VFD control. In 2003 the Perdue processing plant shut down and influent flow to the plant has been significantly reduced from around 1.2 mgd ADF in 2003 to around 0.45 mgd ADF today The Wooten Company has been asked to assist the Town in developing a plan for optimal use of the existing plant facilities under the reduced loading conditions. Currently three of the six existing clarifiers have been taken out of service and other process changes may be planned as well. One aspect of our approach is to repair the VFD control .system at the oxidation ditch and implement measures that will improve and optimize the operation of the existing oxidation ditch system under current loading conditions. Since the oxidation ditch aerators constitute the single largest electrical load at the plant, it is vital to reduce electrical costs in a time when the Town has lost significant water and sewer revenue resulting from the Purdue closure. 11/30/25309 14:41 2529469215 NCDENR DWO PAGE 04/07 Ms. Kristin C. Jarman Page 2 March 9, 2007 Therefore, in consideration of the above factors, the Town desires to primarily focus on repairs to the VFD control system in the near term along with other plant optimization strategies as a result of reduced influent loading. We acknowledge that improvements could be made to the plant's stand-by power capabilities; however, there is potential to delay such expenditures if we can reduce the overall plant olcctrical power consumption such that the current stand-by power systems can support the critical processes without the need for supplemental stand-by power at this time. Historically the Town of Robersonvillc has been an exemplary steward of the Statc's natural resources and has alwaysworked closely with the Washington Regional Office. We respectfully ask for your consideration of our planned approach ab V Tdwould welcome the opportunity to discuss these iss"es further with your office if necessary. If you have any questions our need additional information, please do not hesitate to contact me. Thanks for your assistance in this matter and we look forward to your response. Sincerely, c: Mr. John Pritchard, Town of Robersonville Mr. Willie Andrews, Town of Robersonvillc Mr. Bucky Moore, The Wooten Company 11/30/2009 14:41 2529469215 NCDENR Dw0 PAGE 02/07 February 6, 2Q07 ¶IIJoartz of CROt EZS.onuittE P.O. BOX 487 ROBERSONVILLE, N. C. 27871 PHONE (252) 795-3511 RECEIVE. FEB 0/700/ D'` 0-MVA62Q Kristin C. Jarman Wastewater Treatment Plant Consultant Division of Water Quality 943 Washington Square Mall Washington, NC 27889 Subject: Response to December 5, 2006 Compliance Evaluation Inspection Town of Robersonville Robersonville WWTP Permit No.: NC0026042 Martin County Dear Kristin Jarman: The Town of Robersonville is responding to our main aerators not on any emergency power source in the event of an electrical power failure. By the town owning their electrical system our priority is making sure that the waste treatment system is back on line first. If the main substation goes out, North Carolina Power is on the scene fairly quickly. As of this letter our engineers, The Wooten Company, is working on a solution to the Town's emergency power for the main aerators. The Wooten Company said they would address a letter to you and the Division within two weeks. During any event, the Town and I will do all we can do to keep untreated waste water from being discharged. If you have any questions please contact John H. Pritchard, Jr., Town Manager at 252- 795-4006 of Willie Andrews, WWTP ORC at 252-795-4558 or 252-799-8047. Sincerely, WU& OWAIAI Willie Andrews WWTP ORC Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and -Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality January 8, 2007 John H Pritchard, Jr Town of Robersonville PO Box 487 Robersonville NC 27871 SUBJECT: December 5, 2006 Compliance Evaluation Inspection Town of Robersonville Robersonville WWTP Permit No: NC0026042 Martin County Dear Mr Pritchard: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on December 5, 2006. The Compliance Evaluation Inspection was conducted by Kristin C Jarman of the Washington Regional Office. The facility was found to be in Compliance with permit NC0026042. Part II, Section C (7) of your permit states that "The Permittee is responsible for maintaining adequate safeguards (as required by 15A NCAC 2H.0124- Reliability) to prevent the discharge of untreated or inadequately treated wastes during electrical power failures either by means of alternate power sources, standby generators or retention of inadequately treated effluent." The two generators at the Wastewater Treatment Plant will not run the entire plant. The grit chamber, oxidation ditch aerators and 5 of the clarifiers will not be fully operable during an electrical power failure. If no other power source is to be added, a written verification is needed from the Permittee stating that during an electrical power failure there will be no discharge of untreated or inadequately treated wastes. Please send this verification within 30 days from the date this letter is received. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 252-948-3918. Sincerely, Kristin Cinan Wastewater Treatment Plant Consultant cc: Willie Lee Andrews, ORC Central Files Washington Files North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 Customer Service Internet www.newaterquality.org 943 Washington Square Mall, Washington, NC 27889 FAX (252) 946-9215 1-877-623-6748 V� Won` Carolina ataral4' An Equal Opportunity/Affirmative Action Employer- 50% Recyctedll0% Post Consumer Paper United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmo/day Inspection 1 HI 2 15' 31 NC0026042 111 121 06/12/05 117 �--t �-_� 1 1 Type Inspector Fac Type 181 r-1 191 cI 201 i U �J !J I I I I 1 1 1 I I 1 I I I I 166 Remarks 211 I I I I I I I 1 I J 1 1' 11 1 1 1 1 1 1 1 1 1 I I I I 1 I I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA 67 69 70111 7111 72 tJ Reserved 73 u 74 75f I I I I , I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Robersonville WWTP 1149 Rogerson Rd Robersonville NC 27871 Entry Time/Date 10:00 AM 06/12/05 Permit Effective Date 05/06/01 Exit Time/Date 11:15 AM 06/12/05 Permit Expiration Date 09/11/30 Name(s) of Onsite Representative(s)/Titles(s)!Phone and Fax Number(s) /// Willie Lee Andrews/ORC/252-795-4558/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number John H Pritchard, PO Box 487 Robersonville NC 27871/Town Contacted Manager/252-795-4558/2527954607 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review • Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) • (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Kristin C Jarman 116WARO WQ//252-945-6481 Ext.3151 Jig/o7 Sign of nag ment Q A Reviewer Agency/Office/Phone and Fax Numbers Date tikv),..",---- ,R C - 79' t ,4 7,Q1 // et t ? EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 31 WOES NC0026042 ill 121 yrlmolday Inspection Type 06/12/05 I17 18U (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) DMRs were reviewed from May 2005 through August 2006. There were 3 daily maximum violations for Mercury. The bar screen needs to be repaired as well as the skimmer arm on one of the clarifiers. Five weirs need replacing. The outside wall of the dechiorination tank needs to be repaired. All walkways and rails need to be checked for safety issues. The two generators on site will not run the entire wastewater plant. The grit chamber, oxidation ditch aerators and 5 of the clarifiers will not be fully operable during an electrical power failure. If no other power source is to be added, a written verification is needed from the Permittee stating that during an electrical power failure there will be no discharge of untreated or inadequately treated wastes. Page # . 2 Permit NC0026042 Owner - Facility: Robersonville WWTP Inspection Date: 12/05/2006 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally dean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ 0 0 0 Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? 0 0 • 0 Is the facility as described in the permit? 0 • 0 0 # Are there any special conditions for the permit'? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Facility has a BNR basin before the oxidation ditches. They have 6 clarifiers and 3 chlorine contact chambers. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? • 0 0 0 Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑ Is the chain -of -custody complete? • 0 ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling 0 Results of analysis and calibration 0 Dates of analysis 0 Name of person performing analyses 0 Transported COCs 0 Are DMRs complete: do they include all permit parameters? • ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? 0 0 • 0 Is the ORC visitation log available and current? • ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? • ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facilityvclq.sifi ation? ■ ❑ ❑ ❑ iiw i a y u bL .i� :14A + .�:t wia� Page # 3 • Permit: NC0026042 Owner - Facility: Robersonville WIIVTP Inspection Date: 12/05/2006 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? 11000 Facility has copy of previous year's Annual Report on file for review? 1.000 Comment: • Y Effluent Pipe es No NA NE Is right of way to the outfall properly maintained? • ❑ 0 Are the receiving water free of foam other than trace amounts and other debris? • 0 If effluent (diffuser pipes are required) are they operating properly? Q 0 • 0 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 11000 Is flow meter calibrated annually? • 0 0 .0 Is the flow meter operational? 11000 (If units are separated) Does the chart recorder match the flow meter? 0 0 ■ 0 Comment: Meter was calibrated on 4-4-06. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • 000 Is the wet well free of excessive grease? 0 • 0 0 Are all pumps present? • 0 0 Are all pumps operable? M 0 0 Are float controls operable? ® C3 0 0 Is SCADA telemetry available and operational? 0 0 • 0 Is audible and visual alarm available and operational? 1 ❑ 0 ❑ Comment: Wet well had Tots of old grease and needs to be cleaned. Bar Screens Yes No NA NE Type of bar screen a.Manual 0 b.Mechanical Are the bars adequately screening debris? • ❑ 00 Is the screen free of excessive debris? • ❑ 0 0 is disposal of screening in compliance? • ❑ 0 Page # 4 Permit NC0026042 Inspection Date: 12/05/2006 Owner « Facility: Robersonville W%NTP inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Is the unit in good condition? 0 • 0 0 Comment: The bar screen side panel is rusted out and needs replacing. Grit Removal Yes No NA NE Type of grit removal a.Manual 0 b. Mechanical ■ Is the grit free of excessive organic matter? • 0 0 0 Is the grit free of excessive odor? ■ ❑ 0 ❑ # Is disposal of grit in compliance? • 0 0 0 Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • 0 0 0 Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ■ 0 0 Are weirs level? ❑ ■ 0 0 Is the site free of weir blockage? ■ 0 ❑ 0 Is the site free of evidence of short-circuiting? 0 • 0 0 Is scum removal adequate? ■ 0 0 0 Is the site free of excessive floating sludge? ■ ❑ ❑ ❑ Is the drive unit operational? ■ 0 ❑ ❑ Is the retum rate acceptable (low turbulence)? • 0 0 0 Is the overflow clear of excessive solids/pin floc? ■ 0 0 ❑ Is the sludge blanket level acceptable? (Approximately'/. of the sidewall depth) ■ 0 0 0 Comment: Five of the six weirs need replacing. Weirs are not level and cracked with flow going under the weir in places. One of the clarifiers has the skimmer arm out. This clarifier was not discharging at the time of the inspection. Skimmer arm needs to be fixed. Oxidation Ditches Are the aerators operational? Are the aerators free of excessive solids build up? # Is the foam the proper color for the treatment process? Does the.foam cover less than 25% of the basin's surface'? Lv lJ I is 1 Yes No NA NE ■ ❑ ❑ ❑ ■ ❑❑❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page # Permit NC0026042 Inspection Date: 12/05/2006 Owner - Facility: Robersonville VWVTP inspection Type: Compliance Evaluation Oxidation Ditches Yes No NA NE Is the DO level acceptable? 0 a 0 0 Are settleometer results acceptable (> 30 minutes)? • 0 00 Is the DO level acceptable?(1.0 to 3.0 mg/I) • 0 0 0 Are settelometer results acceptable?(400 to 800 ml/l in 30 minutes) • 0 0 Q Comment: DO is high, 4-5 ppm. The aerators can not be regulated. The normal DO in an oxidation ditch is between 1 and 3. Overaeration can cause floc shearing and be an additional energy cost burden on the Town. Nutrient Removal Yes No NA NE # Is total nitrogen removal required? • 0 0 0 # Is total phosphorous removal required? • 0 Type Biological # Is chemical feed required to sustain process? 0 0 • CI Is nutrient removal process operating properly? • ❑ 0 0 Comment: Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the fitter media present? • 0 0 0 Is the filter surface free of clogging? • 0 ❑ 0 Is the filter free of growth? ■ 0 0 Is the air scour operational? • 0 0 0 Is the scouring acceptable? • ❑ 0 ❑ Is the clear well free of excessive solids and filter media? • 0 0 Comment: Tertiary filter #4 has a ruptured plate and is not being used. Three filters are running. The rails and walkways are rusted and should be checked for safety issues. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? I 0 CI Are cylinders protected from direct sunlight? • 0 Is there adequate reserve supply of disinfectant? • 0 0 0 Is the level of chlorine residual acceptable? • ❑ 0 Is the contact chamber free of growth, or sludge buildup? • 0 Is there chlorine residual prior to de -chlorination? • 0 0 01 Page # 6 • Permit NC0026042 Owner - Facility: Robersonville WWTP Inspection Date: 12/05/2006 Inspection Type: Compliance Evaluation Disinfection -Gas Yes No NA NE Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? 0 0 • 0 If yes, then is there a Risk Management Plan on site? 0 0 • ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? • 0 0 0 Is storage appropriate for cylinders? 0 0 • 0 # Is de -chlorination substance stored away from chlorine containers? • 0 0 0 Comment: Are the tablets the proper size and type? 0 0 • 0 Are tablet de -chlorinators operational? 0 0 • 0 Number of tubes in use? Comment: Rails of walkways are rusted. Outside wall of the dechiorination tank has a hole in it and needs to be fixed . Inside wall is ok. Standby Power Yes No NA NE Is automatically activated standby power available? • ❑ ❑ 0 Is the generator tested by interrupting primary power source? • ❑ ❑ ❑ Is the generator tested under load? • 0 0 0 Was generator tested & operational during the inspection? 0 • 0 0 Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ■ 0 0 Is there an emergency agreement with a fuel vendor for extended run on back-up power? • 0 ❑ ❑ Is the generator fuel level monitored? • 0 0 0 Comment: Facility has 2 generators. They can not run the entire plant. The grit chamber, oxidation basin aerators, and 5 of the 6 clarifiers will not operate properly during a power failure. The Permittee is.responsible for maintaining adequate safeguards to prevent the discharge of untreated or inadequately treated wastes during electrical power failures. Pumps-RAS-WAS Are pumps in place? Are pumps operational? ' c.0 v l Yes No NA NE ■ ❑❑❑ ■ ❑ ❑ CI Page # 7 Permit NC0026042 Inspection Date: 12/05/2006 Owner - Facility: Robersonville WWTP Inspection Type: Compliance Evaluation Pumps-RAS-WAS Yes No NA NE Are there adequate spare parts and supplies on site? • 0 ❑ 0 Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? • 0 0 ❑ Are all other parameters(excluding field parameters) performed by a certified lab? • 0 0 0 # Is the facility using a contract lab? • 0 0 Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ 0 0 0 Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? • 000 Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? • 0 0 0 Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? 0 • 0 0 Is sample collected above side streams? 0 • 0 0 Is proper volume collected? • • 0 0 0 Is the tubing dean? 0 0 0 • Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? • 000 Is sampling performed according to the permit? • ,0 0 0 Comment: Sampling is time proportional. Sample is collected prior to decant from digestor and domestic from office. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 • 0 0 Is sample collected below all treatment units? • 0 0 0 Is proper volume collected? • 0 0 0 Is the tubing dean? 0 0 0 • Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ 0 0 0 Is the,facility sampling performed as required by the permit (frequency, sampling type representative)? ■ 0 0 0 Comment: Sampling is time proportional Page # 8 4