Loading...
HomeMy WebLinkAboutBrunswick_Well Abandonment_20220527 (2) WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Core D. Futral y 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only I GW-30 is needed. Indicate TOTAL NUMBER of 4330-B wells abandoned: NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): (gal.) FEN.M CATLIN Engineers and Scientists FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: MAY 2:Well Construction Permit#: °� List all applicable well construction permits(i.e.UIC,Canty,State, Variance,etc.)i known 7d.Amount of disinfectant used:_ Worrorm"an Procowing i inm 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑Municipal/Public ❑Neat Cement Grout 19 Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑ Specialty Grout ❑Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑Other(explain under 7g) XMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation Bentonite Pellets 4 lbs ❑Aquifer Storage and Recovery ❑Salinity Barrier -- ❑Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer Pulled well shield. Well broke beneath surface. ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) Abandoned with hydrated bentonite pellets and a.Date well(s)abandoned: 5/18/2022 topped with topsoil to existing grade. 5a.Well location: NCDEQ-Jennifer's Subdivision Unknown Facility/Owner Name Facility ID#(if applicable) 8.Certification: G� 3198 Mt. Misery Rd., Leland 28451 5/19/2022 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Brunswick NA By signing this form, I hereby certify that the tvell(s) was(here) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or•2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field,one laVlong is sufficient) 9.Site diagram or additional well details: 34.304448 N -78.076492 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELLS)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction records)ifavailable.Fortnultiple injection ornon-walersupplr>+ells ONLY with the same conriructiodabandoninent,you can submit one form 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#: DW-1 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 34 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Injection Wells: In addition to sending the form to the address in 10a 6c.Borehole diameter: 8.25 (in) above, also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: Block @ 2.82(ft.) Division of Water Resources,Llnderground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): NA (ft.) 10c.For Water Supply&Injection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6f.Inner casing/tubing length(if known): 29 (ft.) abandoned. 6g.Screen length(if known): 5 Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016