Loading...
HomeMy WebLinkAboutSW6220201_Design Calculations (Drawdown)_202205101775 Woodshire Ph 8 Drawdown Time Temporary storage volume = Orifice #Idiameter= Area of orifice = Orifice #2 diameter = Area of orifice = Orifice Coefficient (Cd) _ Orifice elevation -- Water elevation --- Driving head (H) _ Discharge (Q) _ Drawdown time = 68,173 cf 2.75 in 1 0.0413 sf 0 in 0 0.0000 sf 0.60 265.50 ft 268.94 ft 1.15 ft 0.2127 cfs 320517 s 89.0 hr 3_7 days 1775 Pond drawdown.xlsx Printed 5/10/2022