WQ0032289_Monitoring - 01-2022_20220228
FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT(NDMR) Page 1 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System county: Wake Month: January Year: 2022 PPI: 001 Flow Measuring Point: Effluent Parameter Monitoring Point: Effluent Parameter Code 00310 50060 31616 7 00610 00530 00076 r 00400' - � 7 d 2 R Q E O - :t o ay ix o E.oE 1 ;? y:° la x F U 1=y O �o U E oacla a . O O re O Cl)F° it j I 1 I 24-hr Y/N/B hrs mg/L mg/L #/100 mL mg/L mg/L I NTU UNITS _I 1 N 0.47 I - 2 N 0.54 - r -1- 3 0800 Y 8 <2.00 _I 0.42 L <1, <0.10 <2.50..-- 0.71 7.58 _ 4 0800 Y 8 ^<2.00 0.20 <1 <0.10 <2.50 0.52 7.74 5 0800 Y 8 <2.00 1.08 <1 <0.10 <2.50 0.52 7.56 6 0800 Y 8 _ <2.00 0.99 <1 <0.10 <2.50 0.47 7.52 - 7 0800 Y 8 <2.00 0.96 <1 <0.10 <2.50 0.42 7.59 ' 8 N r - 0.44 -, 9 N _ 0.50 � 10 0800 Y 8 -<2.00 0.74 <1 <0.10 <2.50 0.52 7.57 11 0800 Y 8 <2.00 0.72 <1 <0.10 <2.50 0.44 7.70 I 12 0800 Y 8 <2.00 1.95 <1 I -. - <0.10 <2.50 0.40 7.67 _ 13 N �, <2.00 1.90 .. ....._� <0 10 <2.50 I - I-- � - - - �-- 14 N <2.00... 1.43 <1 <0.10 <2.50 0.43 7.62 15 N 0.48 , 16 N 0.92 17 N L 0.48 L- 18 0800 Y 8 <2.00 J 1.00 <1 0.20 <2.50 0.42 7.47 19 0800 Y 8 <2.00 1.17 <1 <0.10 <2.50 0.44 7.50 20 0800 Y 8 <2.00 0.85 <1 <0.10 <2.50 0.44 7.74 { 21 0800 Y 8 . <2.00 { 0.99 <1 <0.10 <2.50 0.49 7.70 - - - 22 N 0.49 - -; . - 23 N 0.52 a 2�I 24 0800 Y 8 <2.00 1.20 <1 0.71 <2.50 0.56 7.48 1 . 25 0800 Y 8 <2.00 1.39 <1 0.12 <2.50 0.59 7.60 7.54 26 0800 Y 8 <2.00 1.56 <1' <0.10 <2.50" 0.61 i 27 0800 Y 8 <2.00 1.79 <1 0.77 <2.50 0.61 1 7.47 28 0800 Y 8 <2.00 1.45 <1 1.98 <2.50 0.58 7.49 29 0555 B 12 0.54 30 0555 B 12 ) 0.48 <2.50 0.50 7.62 g 0 1.16 1.0 0.20 -Average: 0.52 -Daily Maximum: 0 1.95 <1.0 1.98 I 0 31 0800 Y 131 8 I <2.00 `1 �- - -- - _ I- � 0 0.92 7.74 Daily Minimum: 0 0.20 - - Sampling Type:, <1.0 0 0 0.40 7.47 Composite Grab Grab =Composite I Composite Recorder Grab Monthly Limit: 10.00 14 4.00 5.00 6-9 Daily Limit:,-15.00 25 6.00 10.00 10.00 - 1 5 X Week 1 5 X Week , 5 X Week Continuous 5 X Week j Sample Frequency:' 5 xweek 5 X Week , ` ' FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 2 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System county: Wake Month: January Year: 2022 PPI: 002 Flow Measuring Point:Bulk Fill Station Parameter Monitoring Point:Recorder-As Distributed Parameter Code WQ01 r a To v L >, Q E r " .� O r4~ V c w O rt rx O0 1 1 24-hr hrs Gallons I I - - i 1 � - - I I 2 - 3 0800 8 -I _. - 4 0800 8 . - t -- -i 5 0800 8 --i - 6 0800 8 i H - 7 0800 8 -.. 1-.. - 8 9 -; 10 0800 8 I 11 0800 12 0800 8 T -I I— — � ---_[ — I ' l— __I 13 14 f - 15 - 1s _ 17 18 0800 8 19 0800 8 r - 20 0800 8 ' 21 0800 8 I -- 22 24 0800 8 1 25 0800 8 26 0800 8 27 0800 8 I -- — 28 0800 8 _ I-.....- H 29 0555 12 -1 - - ' �-- - 30 0555 12 L 1 1 31 0800 8 1 1 Average: -1 Daily Maximum: I 1-- —I Daily Minimum:, - I , I _ Sampling Type_ Recorder I -.. - -.1 - -.... Monthly Limit: I 1 Daily Limit:I I -L_. -_.l 1 Sample Frequency:I Per Event ` ' FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 3 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System County: Wake Month: January Year: 2022 PPI: 003 Flow Measuring Point:Green Oaks Parkway Median Parameter Monitoring Point:Meters Parameter Code WQ01 ,; ._ ._ E ., #" 7 C m E m Q H .c R ._ I F a. E j 1 p o rt - 24-hr hrs Gallons — -- F 1 2 3 0800 8 r — j 4 0800 g 6 0800 8 j � �5 0800 8 � Ij 7 0800 8 8 10 0800 8 j —.T I — 11 0800 8 i _ I 12 0800 8 - 13 — — — I 14 15 ; f 16 17 -4 '- - - 1_____ -- -- _..—- - i 18 0800 8 19 0800 8 — — - �_... 20 0800 8 — 21 0800 8 22 24 0800 8 F - I , 1 25 0800 8 - H 26 0800 8 1- 27 0800 8 � , - - - � - - -- � - 28 0800 8 29 0555 12 - _ 30 0555 14 - 31 0800 8 I —..—.. Average: Daily Maximum: r- -1-Daily Minimum: Sampling Type: Estimate Monthly Limit: Daily Limit: Sample Frequency: Monthly FORM. NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 4 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System county: Wake Month: January Year: 2022 PPI: 004 Flow Measuring Point:Seqirus,Inc. Parameter Monitoring Point: Meter _ Parameter Code WQ01 ` E y E(Ts y .9;), ix o rx x a 0 ' -- 24-hr hrs Gallons 1 0 { 1 2 0 3 0800 8 0 -----1-- i - - � - - ---1 I - - - - 4 0800 8 0 - - - - - - - - - ; - - -' 5 0800 8 0 6 0800 8 0 _ -- -- ----- 1 I 7 0800 a 0 8 p 9 r.. 0 - 10 0800 8 0 1 11 0800 8 0 1 � 12 0800 8 0 13 0 - 14 0 15 0 16 0 i 17 0 I j � 1 - j 18 0800 8 0 19 0800 8 1 0 1 I I 21 0800 8 1 0 j I p I � i 22 0 _ -- 23 ---T 24 0800 8 0 25 0800 8 0 26 0800 8 0 ! 27 0800 8 0 28 0800 8 0 29 0555 12 0 31 0800 8 0 j Average: 0 j I Daily Maximum: 0 Daily YP 0 1 i =- Sampling Type: Estimate _ Monthly Limit: I Daily Limit:- 1 I I Sample Frequency: Monthly -- I FORM. NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 5 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System county: Wake Month: January Year: 2022 PPI: 005 Flow Measuring Point:The Club at 12 Oaks Parameter Monitoring Point:Meter � Parameter Code I WQ01 c O TS 173y m E 0 E 8N 0 o re o = 24-hr hrs Gallons 1 1 2 3 0800 8 _. 4 0800 8 5 0800 8 6 0800 8 r— I 7 0800 8 I— 8 = { I I 9 10 0800 g 12 0800 8 —.. 13 15 ! 18 0800 8 j —! --- — i — 17 - - 19 0800 g 20 0800 8 21 0800 8 — i I j j i 22 — - ---I 23 24 0800 8 I — 1----- _ I I 25 0800 8 26 0800 8 I 27 0800 8 28 0800 8 29 0555 12 �---� - -------- 30 0555 12 31 0800 8 Average: Daily Maximum: Daily Minimum: -- i-- I- - Sampling Type: Estimate _{ j I Monthly Limit: Daily Limit: 1 Sample Frequency: •nthly FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 6 of 7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System County: Wake Month: January Year: 2022 PPI: 006 Flow Measuring Point:IRD Wake Power Plant Parameter Monitoring Point:Meter Parameter Code WQ01 I T -_ ii 0 a) y 0 E y E c3 = ! m V. COF 3 n 0 0 m 0 0O CC a 24-hr hrs Gallons --- 1 22,879 + 2 22,310 1 3 0800 8 18,436 4 0800 8 16,861 5 0800 8 17,933 6 0800 8 20,227 - 7 0800 8 19,457 , 8 18,142 9 21,046 '', 10 0800 8 20,018 11 0800 8 18,669 rt 12 0800 8 19,524 13 18,956 j-- 14 2 15 19,1316! -- - r 16 13,594 17 16,784 18 0800 8 18,734 -- 1 19 0800 8 18,931 'I I 20 0800 8 19,968 r - --- i --- - - 1 - -- --- � --- % - - - -+ - 21 0800 8 17,175 1 22 13,134 1 1 1 -- -- - - - - 23 16,119 - 24 0800 8 18,943 25 0800 8 19,356 1_ 26 0800 8 17,553 27 0800 8 17,117 r 28 0800 8 18,687 - 29 0555 12 18,470 71 -- I-- 30 0555 12 18,553 31 0800 8 17,710 1 Average: 18,542 -- Daily Maximum: 22,879 Daily Minimum:l 13,134 Sampling Type: Estimate Monthly Limit: r 1 Daily Limit: - L Sample Frequency: Monthly FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page6of7 Permit No.:WQ0032289 Facility Name: Utley Creek WWTP Reclaimed Water System County: Wake Month: January Year: 2022 PPI: 007 Flow Measuring Point:Twelve Oaks Conjunctive Utilization System Parameter Monitoring Point: Meter I Parameter Code WQ01 — c - To O -a 73 r. m E m E m >. Q EIr. •- " la � � �. O Es - - --. - _--- ._-__.-.-I 24-hr hrs Gallons -. -� -, . ...- - -.. -- 2 { 3 0800 8 - ._ - - 4 0800 8 i - --' 5 0800 8 6 0800 8 _ 7 0800 8 — 8 —....— - ----I- — - . _.._.,___ - - - _ 1 ...__ - _ _-._ - ...._. - r --._-- I— — — - 9 11 0800 8 I 1 10 8 i 12 0800 8 G - i- _ - 13 ___I_ 14 r 15 - L - - i 17 r.._ -- ---T _. . `.. _.._.._i - 18 0800 8 � � -- 1- ----- I JI'- --=- ' - - L ---� - I 19 0800 8 I I 20 0800 8 r- -_ _ I - +__.___.._ 22 ! - j 21 0800 8 i - 23 1-- 1 24 0800 8 25 0800 8 I ---i 26 0800 8 - 'I-_ l -- - �-- 27 0800 8 28 0800 8 29 0555 12 30 0555 12 ....... 31 0800 8 Average: Daily Maximum:i Daily Minimum. _ SamplingType: Estimate r- ! G—— - - - 7 —t - I--- I -7 �- _� MonthlyLimit: I j i Daily Limit: - - Sample Frequency: Monthly • FORM:NDMR 05-16 NON DISCHARGE MONITORING REPORT (NDMR) Page 7 of 7 Sampling Person(s) Certified Laboratories Name: WRF Staff Name: Environmental Compliance Laboratory Name: Name: Pace Analytical Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permi As.Compliant ❑ Non-Compliant If the facility is non-compliant, please explain in the space below the reason(s)the facility was not in compliance. Provide in your explanation the date(s)of the non-compliance and describe the corrective action(s)taken.Attach additional sheets if necessary. Ii See attached letter when non-compliant Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Terry Foster Bakup ORC: Casey Denton Permittee: Town of Holly Springs Certification No.: 23920 1007998 Signing Official: Seann Byrd Grade: SI Phone Number: 919-577-1090 Signing Official's Title: Water Resources Director Has the ORC changed since the previous NDMR?No Phone Number: 919-577-1090 Permit Expiration: December 31,2021 o2/Z/Z III "� Y422— Signature Date Signature Date By this signature,I certify that this report is accurrate and complete to the best of my knowledge. I certify,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted.Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true, accurate,and complete.I am aware that there are significant penalties for submitting false information,including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 WQ0032289 <1 User Friendly Name Official Parameter Name DWQ Accepted Units 00010 Temperature Temperature, Water Deg. Centigrade °C 00076 Turbidity Turbidity, HCH Turbidimeter NTU 00092 Flow-Maximum Flow,Maximum Flow Range GPD 00094 Conductivity Conductivity p0 00125 Dichlorobenzene Dichlorobenzene(Isomers)M/P In Water ug/l pg/L 00300 Dissolved Oxygen DO, Oxygen, Dissolved mg/L 1 00310 BOD5 BOD, 5-Day(20 Deg. C) mg/L 00340 COD COD, Oxygen Demand, Chem. (High Level) mg/L 00400 pH pH su 00480 Salinity Salinity mg/L 00515 Total Filterable Residue Residue,Tot Fltrble(dried at 105C) mg/L 00530 Total Suspended Solids Solids,Total Suspended mg/L 00545 Settleable Solids Solids, Settleable mL/L 00556 Oil a Grease Oil It Grease mg/L 00600 Total Nitrogen Nitrogen,Total(as N) mg/L 00610 Ammonia Nitrogen,Ammonia Total(as N) mg/L 00615 Nitrite Nitrogen, Nitrite Total(as N) mg/L 00620 Nitrate Nitrogen, Nitrate Total(as N) mg/L 00625 Total Kjeldahl Nitrogen Nitrogen, Kjeldahl,Total(as N) mg/L 00630 Nitrite+Nitrate Nitrite plus Nitrate Total 1 DET. (as N) mg/L 00660 Ortho Phosphate Phosphate, Ortho(as PO4) mg/L 00665 Total Phosphorus Phosphorus,Total(as P) mg/L 00670 Organic Phosphorus Phosphorous,Total Organic(as P) mg/L 00680 Total Organic Carbon Carbon,Tot Organic(TOC) mg/L 00681 Dissolved Organic Carbon Carbon, Dissolved Organic(As C) mg/L 00916 Calcium Calcium,Total(as Ca) mg/L 00927 Magnesium Magnesium,Total(as Mg) mg/L 00929 Sodium Sodium,Total(as Na) mg/L 00931 Sodium Adsorption Ratio Sodium Adsorption Ratio Ratio 00937 Potassium Potassium,Total(as K) mg/L 00940 Chloride Chloride(as Cl) mg/L 00945 Sulfate Sulfate,Total(as SO4) mg/L 01002 Arsenic Arsenic,Total(as As) mg/L 01007 Barium Barium,Total(as Ba) mg/L 01022 Boron Boron,Total(as B) mg/L 01027 Cadmium Cadmium,Total(as Cd) mg/L 01034 Chromium Chromium,Total(as Cr) mg/L 01042 Copper Copper,Total(as Cu) mg/L 01045 Iron Iron,Total(as Fe) mg/L 01051 Lead Lead,Total(as Pb) mg/L 01055 i Manganese Manganese,Total(as Mn) mg/L i Municipal: Holly Springs NC Report: Meter Details - \N Se fif Customer Name: INGENCO RENEWABLE DE Location Address: 3911 OLD HOLLY SPRINGS APEX RD Account Number: 01887 Serial Number: 19815485 Water Meter Details Meter ID 00002352972 Customer Name INGENCO RENEWABLE DEVELOPMENT Serial Number 19815485 Location Address 3911 OLD HOLLY SPRINGS APEX RD Last Read [Unit] 2220326 Home Phone No. Last Read Time 02/07/2022 1:00 PM Mobile Phone Status Leak Alarm Meter Size 1 1/2"REUSE Service Type Water Location Notes Service Type Water Comments DailyConsumption Data Date Last Read (Gallons) Consumption Meter Status Read Method 02/02/2022 2122886.0 17494.0 Leak Alarm Fixed Network 02/01/2022 2105392.0 10289.0 Leak Alarm Fixed Network 01/31/2022 2095103.0 17710.0 Leak Alarm Fixed Network 01/30/2022 2077393.0 18553.0 Leak Alarm Fixed Network 01/29/2022 2058840.0 18470.0 Leak Alarm Fixed Network 01/28/2022 2040370.0 18687.0 Leak Alarm Fixed Network 01/27/2022 2021683.0 17117.0 Leak Alarm Fixed Network 01/26/2022 2004566.0 17553.0 Leak Alarm Fixed Network 01/25/2022 1987013.0 19356.0 Leak Alarm Fixed Network 01/24/2022 1967657.0 18943.0 Leak Alarm Fixed Network 01/23/2022 1948714.0 16119.0 Leak Alarm Fixed Network 01/22/2022 1932595.0 13134.0 Leak Alarm Fixed Network 01/21/2022 1919461.0 17175.0 Leak Alarm Fixed Network 01/20/2022 1902286.0 19968.0 Leak Alarm Fixed Network 01/19/2022 1882318.0 18931.0 Leak Alarm Fixed Network 01/18/2022 1863387.0 18734.0 Leak Alarm Fixed Network 01/17/2022 1844653.0 16784.0 Leak Alarm Fixed Network 01/16/2022 1827869.0 13594.0 Leak Alarm Fixed Network 01/15/2022 1814275.0 19131.0 Leak Alarm Fixed Network 01/14/2022 1795144.0 20386.0 Leak Alarm Fixed Network 01/13/2022 1774758.0 18956.0 Leak Alarm Fixed Network 01/12/2022 1755802.0 19524.0 Leak Alarm Fixed Network 01/11/2022 1736278.0 18669.0 Leak Alarm Fixed Network harryMir Municipal: Holly Springs NC Report: Meter Details -‘N aS 4' w . 01/10/2022 1717609.0 20018.0 Leak Alarm Fixedti Network 01/09/2022 1697591.0 21046.0 Leak Alarm Fixed Network 01/08/2022 1676545.0 18142.0 Leak Alarm Fixed Network 01/07/2022 1658403.0 19457.0 Leak Alarm Fixed Network 01/06/2022 1638946.0 20227.0 Leak Alarm Fixed Network 01/05/2022 1618719.0 17933.0 Leak Alarm Fixed Network 01/04/2022 1600786.0 16861.0 Leak Alarm Fixed Network 01/03/2022 1583925.0 18436.0 Leak Alarm Fixed Network 01/02/2022 1565489.0 22310.0 Leak Alarm Fixed Network 01/01/2022 1543179.0 22879.0 Leak Alarm Fixed Network 12/31/2021 1520300.0 21400.0 Leak Alarm Fixed Network Total 623986.0 .0 �J' harrryAA Customer Name:1NGENCO RENEWABLE DEVELOPMENT Location Address:3911 OLD MOLLY SPRINGS APEX RD Consumption Period:From:12 31 2021,To:42 01 2022 • Total Consumption For Period:606492.0 Gallons 22.5k • 19,968 20ki935. —_.— --- --- — — 18,943 18,687 18,470 17,553 18,553 kf= 17,710 17.5k —',r.z. 17,1.7-. --- — — 17,117- — — -- ;; 16,119 15k ---F.` — — — — — --- — �,. 13,134 12.5k o —_. — — — — — — — c „ LI 10289 10k — — �w e .7.5k -- 5k — -- — — 2.5k -- — -- — -- — — ——_ — 0k i - — ; --r-- r12 rL2 r1R' n r ry2 't2 r`2 ,�2 ry2 rti2 ry2 rL2 22 ,yO 20 ,�O Cr' n.. nO r�O ,40 ,,O 20 ,t0 20 ,20 20\ 21\ r12\• 2%. `2p�, •2c)\ 2�, 2A\ 2yt 2n' 's,0\ "N\ 01\ 01\ 01\ 01\ o~, 01, 01\ 0,' 0,\ 01\ 0N\ 01\ 01\ o'V h rr`w