Loading...
HomeMy WebLinkAboutNCG030630_2021 DMR_20220128I�IG APR R Pu1Ru.0 a.�vl� Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0630 Person Collecting Samples: MARK WILLINGHAM Facility Name: HARPER CORPORATION OF AMERICA Laboratory Name: WAYPOINT Facility County: MECKLENBURG Laboratory Cert. No.: 402 Discharge during this period: ]Yes [] No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?VYes r7 No If so, which Tier (I, II, or III)? III A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ®✓ Yes No Date Uploaded: 12/10/21 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 01 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class CLASS C N/A Date Sample Collected MM/DD/YYYY 10/28/21 46529 24-Hour Rainfall in inches 0.35 C0530 TSS in mg/L (100 or 50*) 20.5 _ pH in standard units (6,0-9.0 FW, 6.30 00400 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0.159 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) 0.0008 Zinc, total recoverable in mg/ L (0,126 01094 FW, 0.095 SW) 0.198 Chemical Oxygen Demand (COD) in 00340 mg/L (120) 295 00552 Non -Polar Oil & Grease in mg/L (15) <15 * Outfails to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary nursery Areas trrvAl have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): COD ANALYSIS TAKEN SEPARATELY ON 12130/2021, REGIONAL OFFICE NOTIFIED OF EXCEEDANCE "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature f PerrrWttee�Ielegated Authorized Individual 12/10/21 V 1 �B Z� Date