Loading...
HomeMy WebLinkAboutNC0005266_Compliance Evaluation Inspection_20220405DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN 21IIIIII Code I 2 IL I IIIIIIIIIII NPDES yr/mo/day Inspection 3 I NC0005266 111 121 22/04/05 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIII I IIIIII P6 Inspection Work Days 671 Facility Self -Monitoring Evaluation Rating B1 QA Reserved I 70I I 711 172 I N I 73I 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) LP Roaring River WWTP NC Hwy 268 Roaring River NC 28669 Entry Time/Date 10:OOAM 22/04/05 Permit Effective Date 19/12/01 Exit Time/Date 12:30PM 22/04/05 Permit Expiration Date 24/09/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// James Alfred Boles/ORC/336-984-0294/ Michael Wayne Jolly/ORC/336-696-2751/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Melonie Byrd,PO Box 98 Roaring River NC 286690098/Env Engineer/336-696-3337/3366963443 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Patricia Lowery of Inspector(s) Agency/Office/Phone and Fax Numbers Date Docusignedby: DWR/WSRO WQ/336-776-9691/ 4/13/2022 Patna& (,owt,n/1 42D62165508C476... Signatu e of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date LDocuSigned by: ,�e,,, �. ,-ti DWR/WSRO 336-776-9695 4/13/2022 OD2D3CE3F1 B7456... EPA Fo m 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC 31 NPDES yr/mo/day NC0005266 I11 121 22/04/05 17 Inspection Type 18LI (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 4/5/2022, Tricia Lowery met with Mike Jolly, ORC to perform Compliance Evaluation Inspection at LP Roaring River WWTP, NC0005266. This inspection consisted of two parts: 1) in -office file review, and 2) on -site inspection of the treatment facility. Mike Jolly assisted with the in -office review, and escorted inspector through the facility during the on -site inspection. The attached EPA inspection form detail the areas that were evaluated with their respective comments. This facility is currently ungoing changes that will ultimatley transistion to a non -discharge facililty. Currently, the facility does not discharge to surface waters. Overall, the facility is well maintained and no significant issues were found during inspection. Page# 2 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑ application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ • ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Submitted a permit modification application to existing permit on April 16, 2021. Operations now focuses on paint finishes for siding as production of siding has moved to another location. Coating wastewater is currently at a flow of <2000 gpd (projected max of 6000 gpd future). Currently has 5 year pump and haul contract with DEQ. Coatings have low VOC's (water based coating). Future plans (currently being implemented) are: close out diversion ponds, block outlet to mix box, solids to landfill, treated wastewater storage and evaporation between #1 and #2 lagoons (with operation of 1-2 surface aerators), and treated coating wastewater going into aeration basin, then transfered to lagoons for evaporation. *NPDES for sanitary flow/non-discharge for production flow. Sanitary flow on permit 0.03 MGD going to Outfall #2 Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • Page# 3 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: The average annual flow is <200,000 gallons per day, therefore no annual report is needed. The facility is visited daily due to lab certification requirements. All record keeping is in order. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ El El Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Facility conducts BOD, COD, TSS, and SS for process controls. Facility overall is maintained well. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ El El Is sample collected below all treatment units? • El El El Is proper volume collected? • El El El Is the tubing clean? • El El El # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ El El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: Sampling is flow proportionate with 400m1 aliquots. Samples are kept in laboratory refrigerator. Temperature was checked and is at 4 C. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 4 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Comment: BOD/TSS are done within the facility's certified lab. All incubators and refrigerators are kept at appropriate temperatures (105 C for TSS incubators and 4 C for refrigerator/sample storage). Lab is well maintained. Inspector found no issues. Inspector reviewed DMR against bench sheets and found no issues with data reporting. Meritech is used for other parameters. Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical • Are the bars adequately screening debris? • ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: None Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Is the wet well free of excessive grease? • ❑ ❑ ❑ Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? • ❑ El El Are float controls operable? • El El El Is SCADA telemetry available and operational? ❑ El • ❑ Is audible and visual alarm available and operational? El El El • Comment: None Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • El El El Is the site free of excessive buildup of solids in center well of circular clarifier? • El ❑ ❑ Are weirs level? • El El El Is the site free of weir blockage? • ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ■ ❑ ❑ ❑ Is scum removal adequate? ■ El ❑ ❑ Is the site free of excessive floating sludge? • El El El Page# 5 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Primary Clarifier Is the drive unit operational? Is the sludge blanket level acceptable? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: Primary clarifier is used for EQ basin and vice versa. Dual purpose. Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Comment: See primary clarifier comments. Yes No NA NE • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Lagoons Yes No NA NE Type of lagoons? Aerated # Number of lagoons in operation at time of visit? 1 Are lagoons operated in? Parallel # Is a re -circulation line present? • ❑ ❑ ❑ Is lagoon free of excessive floating materials? • El ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ■ ❑ ❑ ❑ Are dike slopes clear of woody vegetation? • ❑ El El Are weeds controlled around the edge of the lagoon? • El El El Are dikes free of seepage? • El ❑ ❑ Are dikes free of erosion? • El El El Are dikes free of burrowing animals? • El ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple El El El • locations? # If excessive algae is present, has barley straw been used to help control the growth? POMP Is the lagoon surface free of weeds? • El El El Is the lagoon free of short circuiting? • El ❑ ❑ Page# 6 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Lagoons Yes No NA NE Comment: Upcoming plans with upgrade: Treated wastewater storage and evaporation between #1 and #2 lagoons with operations of 1-2 aerators. Industrial treated coating waste is going to aeration basin, then going to lagoon for evaporation. (Note: Non -discharge, not NPDES, is for production flow) Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? ❑ El • El Is the filter surface free of clogging? ❑ El • El Is the filter free of growth? ❑ ❑ • ❑ Is the air scour operational? ❑ ❑ • ❑ Is the scouring acceptable? ❑ El • El Is the clear well free of excessive solids and filter media? ❑ ❑ • El Comment: Facility does not have a secondary clarifier/tertiary filter for NPDES. Effluent from the aeration lagoon goes to an effluent mixing box. Treated with tablet chlorination at end of treatment. Facility does not dechlorinate treated water. With the upcoming upgrades to facility, the outlet to mixing box will be blocked. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Comment: Flow meter is calibrated annually by Carotek (mag meter). Last calibration was 6/7/2021. No flow chart is used with flow meter. Facility uses totalizer. Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Proper chlorination tablets are being used and properly stored. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ 1 • ❑ • ❑ Page# 7 DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC Permit: NC0005266 Inspection Date: 04/05/2022 Owner - Facility: LP Roaring River WWTP Inspection Type: Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, • ❑ ❑ ❑ and sampling location)? Comment: Instream monitor is waived as permittee maintains participation in the Yadkin -Pee Dee River Basin Association. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Yes No NA NE ❑ ❑ ❑ • Comment: Facility does not discharge to surface waters. With upcoming upgrades, facility is moving towards becoming a non -discharge facility. There has been no flow reported on DMR from the past 3 months reviewed. Page# 8