United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction
1 IN
21IIIIII
Code
I 2 IL I
IIIIIIIIIII
NPDES yr/mo/day Inspection
3 I NC0005266 111 121 22/04/05 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIII I IIIIII
P6
Inspection Work Days
671
Facility Self -Monitoring Evaluation Rating B1 QA Reserved
I 70I I 711 172 I N I 73I 1 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
LP Roaring River WWTP
NC Hwy 268
Roaring River NC 28669
Entry Time/Date
10:OOAM 22/04/05
Permit Effective Date
19/12/01
Exit Time/Date
12:30PM 22/04/05
Permit Expiration Date
24/09/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
James Alfred Boles/ORC/336-984-0294/
Michael Wayne Jolly/ORC/336-696-2751/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Melonie Byrd,PO Box 98 Roaring River NC 286690098/Env
Engineer/336-696-3337/3366963443 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Patricia Lowery
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Docusignedby: DWR/WSRO WQ/336-776-9691/ 4/13/2022
Patna& (,owt,n/1
42D62165508C476...
Signatu
e of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
LDocuSigned by:
,�e,,, �. ,-ti DWR/WSRO 336-776-9695 4/13/2022
OD2D3CE3F1 B7456...
EPA Fo m 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
31
NPDES yr/mo/day
NC0005266 I11 121 22/04/05
17
Inspection Type
18LI
(Cont.)
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On 4/5/2022, Tricia Lowery met with Mike Jolly, ORC to perform Compliance Evaluation Inspection at
LP Roaring River WWTP, NC0005266. This inspection consisted of two parts: 1) in -office file review,
and 2) on -site inspection of the treatment facility. Mike Jolly assisted with the in -office review, and
escorted inspector through the facility during the on -site inspection. The attached EPA inspection
form detail the areas that were evaluated with their respective comments.
This facility is currently ungoing changes that will ultimatley transistion to a non -discharge facililty.
Currently, the facility does not discharge to surface waters. Overall, the facility is well maintained and
no significant issues were found during inspection.
Page# 2
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑
application?
Is the facility as described in the permit? • ❑ ❑ ❑
# Are there any special conditions for the permit? ❑ • ❑ ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: Submitted a permit modification application to existing permit on April 16, 2021.
Operations now focuses on paint finishes for siding as production of siding has moved
to another location. Coating wastewater is currently at a flow of <2000 gpd (projected
max of 6000 gpd future). Currently has 5 year pump and haul contract with DEQ.
Coatings have low VOC's (water based coating). Future plans (currently being
implemented) are: close out diversion ponds, block outlet to mix box, solids to landfill,
treated wastewater storage and evaporation between #1 and #2 lagoons (with
operation of 1-2 surface aerators), and treated coating wastewater going into aeration
basin, then transfered to lagoons for evaporation. *NPDES for sanitary
flow/non-discharge for production flow. Sanitary flow on permit 0.03 MGD going to
Outfall #2
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
•
Page# 3
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment: The average annual flow is <200,000 gallons per day, therefore no annual report is
needed. The facility is visited daily due to lab certification requirements. All record
keeping is in order.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ El El
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: Facility conducts BOD, COD, TSS, and SS for process controls. Facility overall is
maintained well.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? • ❑ El El
Is sample collected below all treatment units? • El El El
Is proper volume collected? • El El El
Is the tubing clean? • El El El
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ El El
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑
representative)?
Comment: Sampling is flow proportionate with 400m1 aliquots. Samples are kept in laboratory
refrigerator. Temperature was checked and is at 4 C.
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 4
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Laboratory Yes No NA NE
Comment: BOD/TSS are done within the facility's certified lab. All incubators and refrigerators are
kept at appropriate temperatures (105 C for TSS incubators and 4 C for
refrigerator/sample storage). Lab is well maintained. Inspector found no issues.
Inspector reviewed DMR against bench sheets and found no issues with data
reporting.
Meritech is used for other parameters.
Bar Screens Yes No NA NE
Type of bar screen
a.Manual ❑
b.Mechanical •
Are the bars adequately screening debris? • ❑ ❑ ❑
Is the screen free of excessive debris? ■ ❑ ❑ ❑
Is disposal of screening in compliance? • ❑ ❑ ❑
Is the unit in good condition? • ❑ ❑ ❑
Comment: None
Pump Station - Influent Yes No NA NE
Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑
Is the wet well free of excessive grease? • ❑ ❑ ❑
Are all pumps present? • ❑ ❑ ❑
Are all pumps operable? • ❑ El El
Are float controls operable? • El El El
Is SCADA telemetry available and operational? ❑ El • ❑
Is audible and visual alarm available and operational? El El El •
Comment: None
Primary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater? • El El El
Is the site free of excessive buildup of solids in center well of circular clarifier? • El ❑ ❑
Are weirs level? • El El El
Is the site free of weir blockage? • ❑ ❑ ❑
Is the site free of evidence of short-circuiting? ■ ❑ ❑ ❑
Is scum removal adequate? ■ El ❑ ❑
Is the site free of excessive floating sludge? • El El El
Page# 5
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Primary Clarifier
Is the drive unit operational?
Is the sludge blanket level acceptable?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment: Primary clarifier is used for EQ basin and vice versa. Dual purpose.
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Comment: See primary clarifier comments.
Yes No NA NE
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Lagoons Yes No NA NE
Type of lagoons? Aerated
# Number of lagoons in operation at time of visit? 1
Are lagoons operated in? Parallel
# Is a re -circulation line present? • ❑ ❑ ❑
Is lagoon free of excessive floating materials? • El ❑ ❑
# Are baffles between ponds or effluent baffles adjustable? ■ ❑ ❑ ❑
Are dike slopes clear of woody vegetation? • ❑ El El
Are weeds controlled around the edge of the lagoon? • El El El
Are dikes free of seepage? • El ❑ ❑
Are dikes free of erosion? • El El El
Are dikes free of burrowing animals? • El ❑ ❑
# Has the sludge blanket in the lagoon (s) been measured periodically in multiple El El El •
locations?
# If excessive algae is present, has barley straw been used to help control the growth? POMP
Is the lagoon surface free of weeds? • El El El
Is the lagoon free of short circuiting? • El ❑ ❑
Page# 6
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Lagoons Yes No NA NE
Comment: Upcoming plans with upgrade: Treated wastewater storage and evaporation between
#1 and #2 lagoons with operations of 1-2 aerators.
Industrial treated coating waste is going to aeration basin, then going to lagoon for
evaporation. (Note: Non -discharge, not NPDES, is for production flow)
Filtration (High Rate Tertiary) Yes No NA NE
Type of operation: Down flow
Is the filter media present? ❑ El • El
Is the filter surface free of clogging? ❑ El • El
Is the filter free of growth? ❑ ❑ • ❑
Is the air scour operational? ❑ ❑ • ❑
Is the scouring acceptable? ❑ El • El
Is the clear well free of excessive solids and filter media? ❑ ❑ • El
Comment: Facility does not have a secondary clarifier/tertiary filter for NPDES. Effluent from the
aeration lagoon goes to an effluent mixing box. Treated with tablet chlorination at end
of treatment. Facility does not dechlorinate treated water. With the upcoming
upgrades to facility, the outlet to mixing box will be blocked.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: Flow meter is calibrated annually by Carotek (mag meter). Last calibration was
6/7/2021.
No flow chart is used with flow meter. Facility uses totalizer.
Disinfection -Tablet
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Comment: Proper chlorination tablets are being used and properly stored.
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
1
• ❑ • ❑
Page# 7
DocuSign Envelope ID: 3CC13208-CC34-42DA-977F-A54998B1CFCC
Permit: NC0005266
Inspection Date: 04/05/2022
Owner - Facility: LP Roaring River WWTP
Inspection Type: Compliance Evaluation
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, • ❑ ❑ ❑
and sampling location)?
Comment: Instream monitor is waived as permittee maintains participation in the Yadkin -Pee Dee
River Basin Association.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
❑ ❑ ❑ •
Comment: Facility does not discharge to surface waters. With upcoming upgrades, facility is
moving towards becoming a non -discharge facility. There has been no flow reported
on DMR from the past 3 months reviewed.
Page# 8