Permit: WQ0034454 Effective: 03/30/20 Expiration: 08/31/21 Owner : Polytec Inc
SOC: Effective: Expiration: Facility: Former B & M Investments/Cash & Carry/Cline
County: Rowan 11330 NC Hwy 801
Region: Mooresville
Contact Person: Jack Harmon
Directions to Facility:
Mount Ulla NC 28125
Title: President Phone: 704-660-5195
System Classifications: PC1,
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 03/21/2022
Entry Time 08:30AM Exit Time: 09:30AM
Primary Inspector: Edward Watson Phone:
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Groundwater Remediation
Facility Status: Compliant ❑ Not Compliant
Question Areas:
Record Keeping
(See attachment summary)
Inspection Type: Compliance Evaluation
Well inventory Treatment Units
Page 1 of 4
Permit: WQ0034454 Owner - Facility: Polytec Inc
Inspection Date: 03/21/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
On March 21, 2022, MRO staff performed a Compliance Evaluation of the Former Cash and Carry GW remediation system
under Permit# WI0300466. This system was formerly operating under permit WQ0034454. The recent change of the 02T
Statues places groundwater remediation systems formerly under Non -Discharge to be classified as UIC type permits due to
the presence of an Infiltration Gallery.
O&M records indicate the effluent flow meter is past due for calibration. Calibration of effluent flow meters is to be performed
annually as a condition of the permit.
During the site visit, the O&M records were not present in the treatment trailor. O&M records were emailed to MRO for
review. A copy of the O&M records and the permit should be present and available for review. It is suggested that at least
one year of analytical data also be kept on -site for review.
The groundwater treatment system is permitted by the Division of Water Resources (DWR), any system shut -downs or
system compliance issues need to be reported to the DWR Regional Office within 24 hours of first knowledge that a system
failure or non-compliance issue has occurred. The MRO is requesting that we are copied on all laboratory analytical data for
GW samples collected from this treatment system.
Page 2 of 4
Permit: WQ0034454 Owner - Facility: Polytec Inc
Inspection Date: 03/21/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Operating Records
Was operational log book reviewed?
Does data in log book correlate to operational status referenced in monitoring reports?
Are all recording units (flow, time, pressure) functional? If not, explain.
Is operator performing as required?
Do reports meet permit needs?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The system was recently cleaned on January 24, 2022. An O&M record review from January
2022 through March 21, 2022 documents system maintenance activities.
There are no records of effluent flow meter calibration. A new flow meter was installed on
2-27-2021. A calibration sticker should be present on the effluent flow meter to display
calibration is being maintained.
Treatment
What type of treatment units are present?
Equalization
If Equalization, what are the
Number of units:
Total volume:
Metric used:
Air Strippper
If Air Strippper, what are the
Number of units:
Type:
Capacity:
Manufacturer: QED Model 8.4 EZ
Airstripper
Metric used: Gallons Per Month
Chemical Addition
If Chemical Addition, what are the
Yes No NA NE
•
4
Air
15
Chemical(s) name is added: Polyphosphate
sequestering
agent
At what quantity:
Metric unit rate:
Settling/Clarification
If Settling/Clarification, what are the
Number of units:
Total volume:
Unknown
Page 3 of 4
Permit: WQ0034454 Owner - Facility: Polytec Inc
Inspection Date: 03/21/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Metric used:
Filtration
If Filtration, what are the
Number of units: 1
Type: bag
Capacity:
Manufacturer:
Metric used: Million Gallons per
Day
Oil -Water Separator
If Oil -Water Separator is present, is free product properly stored and contained?
Carbon Absorption
If Carbon Absorption,
What is the number of parallel trains
Number of cannisters per train
Size of cannister:
Metric used:
Other
If Other type of Treatment, what type of 'other"is it?
Four Air Sparge wells completed through the Infiltration gallery are also present as part of site remediation
activities.
1
2
1000
Gallons Per Month
Comment: This system was operating during the site visit. A review of laboratory analytical data indicates
the system is beginning to stabilize.