HomeMy WebLinkAbout20220312 Ver 1_More Info Received_20220307ULTURAL COST SHARE PROGRAM (ACSP) CPO # 11-2017-007 STREAMBANK STABILIZATION Prepared for Shelly Brown 180 Cross Creek Farm Rd., Fletcher, NC Ii .-_ \ \ 1 r i.r�� `� «� �n i \Y (J .Mi,rc y L`iker VICINTY MAP Not to Scale CONTACT NC 811 PRIOR TO CONSTRUCTION TO HAVE UTILITIES LOCATED. THE SOIL AND WATER CONSERVATION DISTRICT AND THE DIVISION OF SOIL AND WATER CONSERVATION MAKE NO REPRESENTATION AS TO THE EXISTENCE OR NON-EXISTENCE OF ANY UTILITIES ON -SITE. SHOWN IN THESE DRAWINGS ARE THE APPROXIMATE LOCATIONS OF THOSE UTILITIES WHICH HAVE BEEN IDENTIFIED. IT IS THE RESPONSIBILITY OF THE LANDOWNERS OR OPERATORS AND CONTRACTORS TO ASSURE THEMSELVES THAT NO HAZARD EXISITS OR DAMAGE WILL OCCUR TO UTILITIES. SHEET #1: TITLE PAGE SHEET #2: SITE OVERVIEW SHEET #3: GRADING PLAN SHEET #4: TYPICAL CROSS-SECTION SHEET #5: GEOLIFT CONSTRUCTION DETAILS SHEET #6: VEGETATION SPECIFICATIONS SHEET #7: COIR MATTING INSTALLATION DETAILS CONSTRUCTION NOTES AND SEQUENCE 1. Obtain plan approval and other applicable permits. 2. Delineate property boundaries within project area, buffer limits, and limits of construction. 3. All equipment is to be stored and fueled in a protected area outside the designated buffer 4. Hold preconstruction conference no more than one week prior to starting construction. 5. Begin installation of rip rap toe at the upstream location of the tie into existing bank. 6. Place non -woven geotextile as indicated in the typical section leaving enough width to wrap the fabric on the back of the rip rap. 7. Place the rip rap as indicated on the plans and as directed by the engineer or their delegate. 8. If required when the equipment can no longer reach from the top of the bank, install access ramp on bank behind the installed rip rap so no active flow can reach the disturbed material. In lieu of building the ramp, a long reach excavator may be used. 9. Continue the rip rap toe to the tie at the downstream end of the project. 10. Wrap geotextile around back of rock toe. 11. Place fill material such that all new material is placed, compacted, and temporarily mulched within the same day it is placed (if geolifts are not completed the same day). Site is to be temporarily stabilized at the end of each day. 12.Begin to place fill material behind the rock toe which will act as a berm to protect newly placed fill from active flow. 13. When fill material is within 10" - 12" of the top of the rip rap toe, place woven coir matting backed by non -woven coir to create a lift on top of the rock toe, as indicated on the plans. Drape the first soil geolift over the front face of the rip rap toe as indicated on the plans. 14. Continue to place fill material to approximatly 1' above the top of the rip rap toe creating the first geolift. 15.Continue constructing geolifts as outlined on Sheet 5 until bankfull elevation is reached. 16.Lime, fertilize, seed (temporary and permanent) and straw mulch all disturbed areas along channel as specified in construction documents. 17.Secure matting with stakes as indicated on the plans. 18.Install remaining fill to existing grade at no more than 2:1 slope. 19.Lime, fertilize, seed (temporary and permanent) and straw mulch all disturbed areas along channel as specified in construction documents. 20.Install woven coir matting per Sheet 7 to a minimum of 2' beyond the top of the bank or as directed by the engineer or their delegate. 21.Plant woody vegetation if soil and plant conditions permit. 22.AII erosion and sediment control practices will be inspected weekly and after each rainfall event. Needed repairs and maintenance will be conducted immediately. 23.After site is stabilized, remove all temporary measures and install permanent vegetation on the road and staging area. 24.Estimated time before final stabilization shall be approximately 2 weeks. 0 0 } t BROWN 11.2017.00 C i 828-713-7915 SHELLY BROWN z 0 F- 0 z WATER CONSERVATION is z AGRICULURE c CONSUMER SERVICES Digitally signed by McKinley L Owen Date: 2022.01.24 11:03:59 -05'00' THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet. No. 1 of 7 LEGEND ABENCHMARK NAIL IN GROUND Scale In Feet 30' 0 \ 1"=30' ///, I I ,i /I I 1 1; 1 // „=ice/ //a.'.7./ %/ ,-• il ,:. 0 11 ii //// // j/- — / ." i /' // \ I '/��'/__— / / / 77 JD I GP' -- APP OX. 100 LF OF STREAMBANK S ABILIZATION .''t,,-t,, TREE FLOOD STUDY PUBLISHED CROSS-SECTION @ STA. 308+24 30' 60' �G� / T, - / ?I CA 361NX4 • + 403 N: 638226.76 E: 967105.94 EL: 2101.90 • -\ \ \ \v. / 21 /i 1'\ \ \ \ 4Q4 N: '538330.99 E: 96,7148.96 EL: 21 02.58 A 301 N: 638290.63 E: 967189.12 EL: 2102.65 / / / / 3 TREE MULTI-SYCA 201NX4 PROJECT CROSS-SECTION @ STA. 308+94.71 402 N: 638419.35 E: 967364.26 EL: 2114.06 NOTES: 1. ALL ELEVATIONS ARE RELATIVE TO NAVD '88. 2. REFERENCE MARKS SET BY GPS FIELD OBSERVATIONS AND TOTAL STATION ROBOTIC INSTRUMENT. 3. COORDINATES ARE RELATIVE TO NAD '83 AND DISPLAYED AS NORTH CAROLINA STATE PLANE 3200 US SURVEY FEET. 4. ELEVATION DATA DISPLAYED OUTSIDE SURVEY BOUNDARY IS DERIVED FROM NCFMP LIDAR: STATEWIDE NORTH CAROLINA PHASE 2. 5. FEATURES DISPLAYED OUTSIDE SURVEY BOUNDARY ARE DERIVED FROM NC ORTHO IMAGERY. 0 LAYNE OWEN, PE BROWN_ 11.2017.007.dwc E 828-713-7915 z O (24 (22 SITE OVERVIEW z 121 0 BUNCOMBE COUNTY, NORTH AND CONSUMER SERVICES • t4.1 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 2 of i - / - / ,'/,/ / / ' - - - - - - - 11 / / I'\ „ - - -, = - - -,,,, / 1 1 • • • • / / 1 /"//// // 1 \ '/'-'2 / \` \\ \off ` /., / \) \ / / \ 1 \`\ / // // J \ / / \ / ` / / -_' / / / / /' / i / // / / / // / ) �i :E MULTI-SYCA 36INX4---"" e In Feet 10' 0 1 = 10' 10' \ / / / / / / / logy/ APPROX. 100 LF OF /STREAMBANK STABILIZATION / 20' Y l%\ • Y \4' '1 4' 4, \ '1 \ 1 II 4' 4Y \\ 4' sic 4, 4, 4, 4, 4, 4' \y -*--`` y * 1 4' 1 4, y 4, I, 4,ly 4' 4,'/ / W W • W W / - / / / /\ // \\ 7 REMOVAL OF CLUSTER OF // 1v ,/, y STUMP TO BE DETERMJNED / / / \`/ j' ' / , - BY ENGINEER AT THE TYMEI OF,'� / \ CONSTRUCTION / / // og5� ,/' / - - __ / / /\. / / // /'/ / // // - _ -- / / / // / // ',/ //// / / _/''''/__'//////// // /,/, / / ` 1 G / / / / // / / / 4/1 /// // _- `--v v v W W W 4' W W W W W y W 4' y 4, 4, y 4, 4, W 4, W W W / \`\ TUMP /^\ I \\ I l \\ RIP RAP SILL WRAPPED 4, 4, IN NON -WOVEN (EOTEXTILE TO BE CONSTFRU(TED AT W W W ENGINEERS DIRE TION Nfr 1 i 4, \ 4, 4, 4, 1 J. 4, Jr-/ .Y \\* sY \1 // / �\ / I // % / / sY-' 4, 4Y 4 'A_ I // / ' ' ----) / / //sy ,y 4' .y / / / / / / /4, 4, 4, *l*'_\\ / / / I / / .y \\'\ '' \\ 1 / .4.0 / \ \ `\ II / RI 4' 4' `\ 1' \\ I ---------- --' I `\ \ 1 I .y .y * `\ \ 1 I / 1\\ 1 I JI 4Y 4Y �1 `\ \\ I I 1• \ 1 40'' 4, 4/ • \\\ \1 'I u' \ 1 ' xs* \\ \\ / 0 1 00 J \\\ \\ / // \ \ / \ `./ / 4, \ \ c" / mow / • \ \ / / / / / /// / / / / / / / / ) 1 • y' \ \ • \• \ • • • 2103, 11 4, 4, 4,\\ 4, \\ 4/ ' 4Y \ 4, 4, 4, 1 alc- 4Y 1 1 / / / / / LAYNE OWEN, PE BROWN_ 1 1 .201 7.007.dwg Li 828-713-7915 SHELLY BROWN z I-� z BUNCOMBE COUNTY, AND CONSUMER SERVICES �\ \ NCARO/,.i ••- • ¢ � SEAL 0436461 : 2 n • • GrJ ��\``� THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 3 of 7 2110 2105 2095 2090 — - EARTHFILL - — APPROX. 140 CY — SOIL GEOLIFTS — — SEE SHEET A► 5 FOR DETAILS — hICDOT CLASS 2 RIP RAP • - — — — APPROX. 200 TONS NON -WOVEN, �— NEEDLE -PUNCHED GEOTEXTILE APPROX. 25D SY I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LC) LC) 0 0 M 0 r` M 0 co M CROSS-SECTION - STA. 308+94.71 PROFILE LC) CO M 0 rn M 0 0 +(l(l 2110 2105 2100 2095 2090 LEGEND SURFACE COLOR FLOOD STUDY PUBLISHED CROSS-SECTION STA. 308+24 2006 BARE EARTH LiDAR 2019 DEM from 2017 LiDAR 11/2021 FIELD SURVEY PROPOSED REPAIR Stream: Basin: Drainage Area: Location: Latitude: Longitude: Date: Valley Type: Bankfull Width (Wbkf): Bankfull Depth (Dbkf): Bankfull X-Section Area (Abkf): Width/Depth Ratio (Wbkf/Dbkf): Maximum Depth (Dmax): Width of Flood -Prone Area (Wfpa): Entrenchment Ratio (ER): Channel Materials (D50): Water Surface Slope (S): Channel Sinuosity (k): STREAM CHANNEL CLASSIFICATION: Cane Creek French Broad 34,560 acres (54 square miles) Buncombe County, North Carolina 35.45434° N 82.46928° W February 25, 2015 VIII 78 feet 8 feet 460 square feet 9.75 8 feet 1080 feet 13.8 12 mm 0.008 feet/feet 1.12 C4 cn 0 LAYNE OWEN, PE BROWN_ 1 1 .201 7.007.dwg E 828-713-7915 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 4 of 7 20' UNDISTURBED, VEGETATED RIPARIAN BUFFER FROM BANKFULL ELEVATION 2'-4' LIVE BRANCHES TYP. 3'-5' WITH TOPSOIL WOVEN COIR FABRIC SEE SHEET 7 FOR DETAILS 6" WOODEN STAKES LIVE STAKES 2'-3' ON CENTER 2' MAX -I 1' MAX WOVEN COIR FABRIC ON OUTSIDE NON -WOVEN COIR MATTING ON INSIDE NOTES: 1) ENSURE BACKFILL SOIL AND TOPSOIL USED FOR BRANCH LAYERING IS FREE OF LARGE ROOTS, WOODY DEBRIS, AND LARGE GRAVEL AND COBBLE. COMPACT BACKFILL TO REDUCE SETTLING WITHOUT DISPLACING OR DAMAGING UNDERLYING RIP RAP AND BRUSH. 2) SLOPE THE BACKFILL FOR THE FIRST LIFT AWAY FROM THE STREAM AT 5%. 3) PLACE TOPSOIL AND LIVE BRANCHES ON BACKFILL TO ALLOW 6"-12" OF BRANCH TO PROTRUDE AND THE REMAINNG 2-4' WILL BE COVERED BY THE NEXT LIFT. 4) LIVE BRANCHES AND LIVESTAKES OF PLANT MATERIAL SHALL INCLUDE ONE SPECIES OF WILLOW (BLACK WILLOW (SALIX NIGRA), CAROLINA WILLOW (SALIX CAROLINIANA), OR SILKY WILLOW (SALIX SERICEA)); SILKY DOGWOOD (CORNUS AMOMUM); AND ELDERBERRY (SAMBUCUS NIGRA SSP. CANADENSIS). SUBSTITUTIONS MUST BE APPROVED BY THE ENGINEER. 5) WOVEN COIR GEOTEXTILE FABRIC FOR THE SOIL LIFTS SHALL BE WOVEN GEOTEXTILE FABRIC PRODUCED FROM YARNS SPUN FROM NATURAL COIR FIBER AND SHALL MEET THE FOLLOWING SPECIFICATIONS: PROPERTY TEST METHOD ENGLISHUNITS TYPICAL VALUE MD CD MASS PER UNIT AREA ASTM D-6475 18.96 pZIY D2 THICKNESS ASTM D-6525 396 MILS WATER ABSORPTION ASTM D-1117 184 % LIGHT PENETRATION ASTM D-6567 36 % GROUND COVER ASTM D-6241 64 % TENSILE STRENGTH ASTM D-6818 102.8 75.8 LBSIIN ELONGATION ASTM D-6818 45.1 40.3 % 6) SOIL LIFT SHALL BE CONSTRUCTED BY PLACING 6.5 TO 9.5 FEET OF WOVEN COIR GEOTEXTILE FABRIC ON TOP OF THE LIVE BRANCHES AND TOPSOIL, WITH 2.5' TO BE COVERED BY THE NEXT SOIL LIFT. 4.5 TO 7.5 FEET OF THE FABRIC WILL HANG OVER THE RIP RAP OR PRECEDING SOIL LIFT. 7) TOP THE WOVEN COIR GEOTEXTILE FABRIC WTH A 6.5 FOOT PIECE OF NON -WOVEN COIR MATTING TO PROVIDE MULCHING. 8) PLACE A PIECE OF LUMBER USING WOODEN STAKES TO THE LIFT HEIGHT AT THE FACE OF THE LIFT TO PROVIDE A FORM FOR SOIL COMPACTION. 9) BACK FILL SOIL LIFT WITHOUT MOVING OR TEARING THE FABRIC AND WITHOUT DISTURBING THE LIVE BRANCHES. 10) THE TOP OF THE BACKFILL SHALL HAVE 0% SLOPE FROM THE STREAM SIDE EDGE FOR THE FIRST 1 FOOT. BEYOND THE SETBACK (1 FOOT) THE BACKFILL SHOULD BE SLOPED AT A 5% SLOPE AWAY FROM THE STREAM. 11) USING TOPSOIL, DRESS THE LIFT FROM THE FACE TO THE BACK IN TO THE FLOODPLAIN AT A DISTANCE GREATER THAN OR EQUAL TO THE LENGTH OF THE LONGEST LIVE BRANCH. 12) REMOVE COMPACTION FORM, APPLY SEED TO THE TOP AND FACE OF THE SOIL LIFT, AND WRAP WITH THE WOVEN AND NON -WOVEN COIR FABRICS USING THE MATTING THAT WAS ALLOWED TO HANG OVER THE PREVIOUS LIFT OR RIP RAP. TO ENSURE GOOD SOIL CONTACT AND A STABLE LIFT, PULL THE FABRIC TIGHT WITHOUT TEARING OR STRETCHING. 13) USING WOODEN STAKES THAT ARE 2°X2"X1.5', SECURE THE TWO LAYERS OF MATTING BY STAKING THE END BACK IN THE BANK AT 1.5 FOOT CENTERS. 14) REPEAT SOIL LIFT CONSTRUCTION (NOTES 6 TO 17) TO REACH THE TOP OF THE BANK ELEVATION. 15) THE FABRIC OF THE FINAL SOIL LIFT SHALL BE SECURED IN A TRENCH AT LEAST 6-INCHES DEEP AS SHOWN ON THE DETAIL. 16) ADDITIONAL LIVESTAKES SHALL BE INSTALLED ON EACH SOIL LIFT ON 3' CENTERS. LIVESTAKES SHALL BE INSTALLED ON ALL BANK AREAS DISTURBED DURING CONSTRUCTION AND AT THE BANK TIE IN POINTS. 17) THE TOP SURFACE SHALL BE SMOOTH AND TIE TO THE EXISTING BANK IN THE LOCATIONS INDICATED ON THE PLANS AND AS APPROVED BY THE ENGINEER. FINAL GRADE IS TO BE APPROVED BY THE ENGINEER. THE TOP OF THE SLOPE SHALL BE RAKED, SEEDED AND MULCHED. NCDOT CLASS 2 RIP RAP NON -WOVEN, NEEDLE -PUNCHED GEOTEXTILE FABRIC a v 0 rn 0 LAYNE OWEN, PE BROWN_ 1 1 .201 7.007.dwg E o_ 828-713-7915 z yr 0 (24 CONSTRUCTION BUNCOMBE COUNTY, NORTH CAROLINA AND CONSUMER SERVICES ‘‘"ICI 111pp� NNE �N.0 • • ��i •QO/41 F�Ss SEAL •043646 . : Z • : 1 �111110 ,\``` THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 5 of 7 STREAMBANK STABILIZATION PROCEDURE: 1. SOIL PREP 2. APPLY SEED, LIME, & FERTILIZER AS SPECIFIED 3. APPLY STRAW MULCH AS SPECIFIED 4. INSTALL COIR MATTING EROSION CONTROL BLANKET AS OUTLINED ON TOP OF MULCHED SURFACE 5. INSTALL LIVESTAKES AS SPECIFIED ALL OTHER DISTURBED AREAS: 1. SOIL PREP 2. APPLY SEED, LIME, & FERTILIZER AS SPECIFIED 3. APPLY STRAW MULCH AND/OR ECB AS SPECIFIED STREAMBANK PLANTING MIXTURE CONTENT: *APPLY SEED MIXTURE AT A RATE OF 20 POUNDS PER ACRE. SEED CONTENT RATIO MAY VARY WITH APPROVAL. 20.0% Elymus virginicus (Virginia Wildrye) 20.0% Poa palustris (Fowl Bluegrass) 20.0% Sorghastrum nutans (Indiangrass) 17.0% Panicum anceps, (Beaked Panicgrass) 15.0% Carex vulpinoidea (Fox Sedge) 4.0% Chamaecrista fasciculata (Partridge Pea) 2.0% Helenium flexuosum (Purplehead Sneezeweed) 2.0% Vernonia noveboracensis (New York Ironweed) LIME AND FERTILIZER: LIME: 2,000 POUNDS / ACRE OF FINELY GROUND, DOLOMITIC LIMESTONE FERTILIZER: 400 POUNDS/ ACRE OF 10-10-10 OR EQUIVALENT *THESE RATES ALSO APPLY WHEN HYDROSEEDING MULCHING: SIX (6) FEET WIDTH OF 700 G/M2 COIR MATTING SHALL BE INSTALLED FROM THE STREAM'S EDGE TO BEYOND BANKFULL STAGE AT LEAST 5' UPSTREAM AND DOWNSTREAM OF TIE IN PONTS. BLANKETS SHALL BE ANCHORED WITH WOOD STAKES IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. REMAINING SURFACES MAY BE MULCHED WITH DRY, UNCHOPPED, UNWEATHERED SMALL GRAIN STRAW OR HAY FREE OF SEEDS OF COMPETING PLANTS. SPREAD AT THE RATE OF 1-2 TONS PER ACRE DEPENDING UPON THE SEASON. EVENLY SPREAD MULCH OVER THE AREA BY HAND OR MECHANICAL EQUIPMENT. APPLY MULCH UNIFORMLY SO THAT 25% OF THE GROUND SURFACE IS VISIBLE. TEMPORARY SEED SHALL BE APPLIED TO ESTABLISH GROUND COVER BASED UPON THE FOLLOWING PLANTING TIME FRAME: RYE GRAIN (SECALE CEREALE) 25 LBS/AC AUG 15 - MAY 15 BROWNTOP MILLET (UROCHLOA RAMOSA) 10 LBS/AC MAY 15 - AUG 15 LIVE STAKES AND CUTTINGS: 1. CUTTINGS SHOULD BE INSTALLED THE SAME DAY THEY ARE CUT. THE STAKE SHOULD BE ORIENTED WITH THE BUDS POINTED UP, AND THE BOTTOM SHOULD BE CUT AT AN ANGLE FOR EASY INSERTION INTO THE GROUND. 2. ABOUT 3/4 OF THE LENGTH OF THE STAKE SHOULD BE BELOW GROUND AND ANGLED DOWNSTREAM. AN IRON BAR CAN BE USED TO MAKE A PILOT HOLE TO PREVENT BARK FROM BEING DAMAGED DURING INSTALLATION. TRANSPLANTS AND CONTAINER STOCK: 1. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. 2. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. 3. THE DIAMETER OF THE PLANTING HOLES (PITS) FOR EACH PLANT SHOULD BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. SCARIFY THE PLANTING PIT PRIOR TO EACH PLANT INSTALLATION. 4. SET PLANTS UPRIGHT IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. 5. PLACE BACKFILL AROUND BASE AND SIDES OF ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. GENERAL VEGETATION PLAN NOTES: 1. GROUND COVER, SOIL PREP, TEMPORARY AND PERMANENT VEGETATION SHALL BE INSTALLED ON ALL AREAS DISTURBED DURING GRADING, STRUCTURAL, AND STABILIZATION WORK. 2. LIVE STAKES, TRANSPLANTS, AND/OR CONTAINERIZED PLANTS SHALL BE LOCATED WHERE SHOWN ON PLAN. 3. ADJUSTMENTS TO THE VEGETATION PLAN SHALL BE MADE ONLY IF APPROVED BY THE PROJECT ENGINEER. RECOMMENDED NATIVE PLANT SPECIES FOR RIPARIAN AREAS TREES PAINTED BUCKEYE CHERRY BIRCH RIVER BIRCH BITTERNUT HICKORY SHAGBARK HICKORY PERSIMMON GREEN ASH SILVERBELL BLACKGUM SYCAMORE BLACK CHERRY BLACK WILLOW WHITE BASSWOOD SMALL TREES/SHRUBS TAG ALDER SERVICEBERRY RED CHOKEBERRY COMMON PAWPAW SWEET -SHRUB IRONWOOD ALTERNATE LEAF DOGWOOD SILKY DOGWOOD HAZEL -NUT WITCH -HAZEL WINTER BERRY DOGHOBBLE SPICEBUSH MALE -BERRY UMBRELLA TREE NINEBARK WILD AZALEA SWAMP AZALEA SWAMP ROSE SILKY WILLOW MEADOWSWEET SWEET LEAF W ITH E-ROD YELLOW -ROOT ELDERBERRY ALL SMALL TREES / SHRUBS SHALL BE PLANTED AT SPACING OF 3' X 3'. THE ENTIRE REPAIRED STREAMBANK SHALL BE ESTABLISHED WITH WOODY VEGETATION. cn 0 LAYNE OWEN, PE BROWN_ 1 1 .201 7.007.dwg o_ 828-713-7915 SHELLY BROWN BUNCOMBE AND CONSUMER SERVICES THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 6 of 7 MATTING, TYPICAL (SEE NOTE 1) TOP OF BANK ANCHOR (SEE DETAIL) DEAD STOUT STAKE, TYPICAL (SEE DETAIL) TOP OF BANK MATTING OVERLAP (SEE DETAIL) 6" BACKFILL (SEE NOTE 2) TOE OF BANK ANCHOR SEE DETA MATTING, TYPICAL (SEE NOTE 1) TOP OF BANK MATTING ANCHOR DETAIL MATTING WRAP (SEE NOTE 2) TOE OF BANK DEAD STOUT STAKE, TYPICAL (SEE DETAIL) TOE OF BANK MATTING STAKE, TYPICAL (SEE NOTE 6) • CROSS-SECTION UNTREATED 2" X 4" (NOMINAL) BOARD APPROXIMATE BASE FLOW WATER LEVEL TOE OF BANK 4" 12" 0" — 1/2" DIRECTION 1®OR®2 \7/ 24" 10 DIRECTION OF STREAM FLOW ®2 DIRECTION DOWN THE BANK SLOPE OVERLA 6" 24' MATTING OVERLAP (SEE NOTE 5) MATTING OVERLAP DETAIL 24" OVERLAP 6" MATTING, TYPICAL. (SEE NOTE 1) NOTES: 1. EROSION CONTROL MATTING SHALL CONSIST OF 700 GRAM WOVEN COIR FIBER EROSION CONTROL MATTING (SPECIFICATIONS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO INSTALLATION). MATTING SHALL BE INSTALLED FLAT AND STAKED AGAINST A SLOPE AND/OR A STREAM BANK. 2. MATTING SHALL BE ANCHORED IN A TRENCH AT BOTH THE TOE AND TOP OF THE STREAM BANK. DEAD STOUT STAKES AND CLEAN SOIL BACKFILL SHALL BE USED TO SECURE THE MATTING INTO THE TOE AND TOP OF BANK TRENCHES. TO PREVENT EROSION OR "WASHING OUT" OF BACKFILL IN THE TOE OF BANK ANCHOR TRENCH, MATTING SHALL BE INSTALLED SO THAT IT WRAPS OVER THE DEAD STOUT STAKE AND BACKFILL, THUS POSITIONING THE REMAINING MATTING FOR INSTALLATION UP THE STREAM BANK. 3. THE SLOPE AND/OR STREAM BANK SHALL BE PREPARED (GRADED, TILLED, SMOOTHED, ETC.) AND SEEDED AND MULCHED AS SPECIFIED BY THE DESIGNER PRIOR TO THE PLACEMENT OF THE MATTING. 4. THE MATTING SHALL BE INSTALLED SO AS TO NOT BE IN TENSION, BUT BE PLACED NEATLY, FLUSH AGAINST THE SOIL, AND WITH NO GAPS OR WRINKLES. ADDITIONAL STAKING SHALL BE INSTALLED BY THE CONTRACTOR AS NEEDED TO ENSURE CONTACT WITH THE SOIL. 5. ANY MATTING OVERLAPS NECESSARY SHALL BE OF A LENGTH SPECIFIED BY THE MANUFACTURER OR AS OTHERWISE SPECIFIED BY THE DESIGNER. ALSO, OVERLAPS SHALL BE ORIENTED IN A DOWN -SLOPE DIRECTION, DOWNSTREAM DIRECTION, OR OTHERWISE "SHINGLE -STYLE" IN ACCORDANCE WITH THE DIRECTION OF THE DOMINANT EROSIVE ACTION SO THAT THE MATTING END IS PROTECTED AGAINST MOVEMENT. 6. THE FIELD OF THE MATTING OVER THE SURFACE OF THE SLOPE AND/OR STREAM BANK SHALL BE SECURED WITH MATTING STAKES OF A SIZE AND TYPE, IN A PATTERN, AND WITH SPACING DIMENSIONS AS SPECIFIED BY THE MANUFACTURER OR AS OTHERWISE SPECIFIED BY THE DESIGNER. 7. MATTING SHALL BE NEATLY SECURED AROUND ANY PROJECT STRUCTURES, STRUCTURE ARMS, AND/OR SILLS TO PREVENT ANY LOOSE OR FRAYED EDGES. 8. THERE SHALL BE NO LOOSE ENDS OR UNSECURED MATTING ON THE COMPLETED WORK. 9. THE PLAN VIEW ILLUSTRATES A PERPENDICULAR PERSPECTIVE OF EACH SURFACE DEPICTED IN THE CROSS SECTION. THERE IS NO FORESHORTENING OF THE STREAM BANK (OR ANY OTHER SLOPED SURFACE) IN THE PLAN VIEW. 12" MATTING OVERLAP (SEE DETAIL) / / I • 1 • I 1 I I I I I I I 0 1 0 1 1 10 0 0 0 0 0 ! goo 0 0 0 0 1 0 I L_ 10 0 0 0 0 0 0 0 0 ! 0 0 I 0 0 I- 0 0 0 0 0 V1 " 0 " 0 0 0 ! 0 0 0 0 0 ! 0 0 0 0 0 0 0 0 0 0 0 l O l I I I I I I 12" TOE OF BANK ANCHOR (SEE DETAIL) FLOW PLAN VIEW (SEE NOTE 9) OVERLAP 6" TOP OF BANK MATTING, TYPICAL (SEE NOTE 1) MATTING STAKE TYPICAL (SEE NOTE 6) DEAD STOUT STAKE TYPICAL (SEE DETAIL) APPROXIMATE BASE FLOW WATER LEVEL TOE OF BANK NOT TO SCALE a v o � cn 0 73 LAYNE OWEN, PE BROWN_ 1 1 .201 7.007.dwg 828-713-7915 SHELLY BROWN COIR MATTING INSTALLATION DETAILS AND CONSUMER SERVICES .0111111ffI, \ / CZ.< — SEAL•043646 : Z THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY M. LAYNE OWEN, PE ON JANUARY 24, 2022 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SHA AUTHENTICATION CODE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Sheet No. 7 of 7