Loading...
HomeMy WebLinkAboutNCG500611_Permit (Issuance)_20070723ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Coleen H. Sullins, Director Nicole Johnston Interface FABRIC, Inc. 304 East Main Street Elkin, NC Dear Permittee: 28621 July 23, 2007 Subject: Renewal of coverage / General Permit NCG500000 Interface FABRIC, Inc. Certificate of Coverage NCG500611 Surry County In accordance with your renewal application [received on January 31, 2007], the Division is renewing Certificate of Coverage (CoC) NCG500611 to discharge under NCG500000. This CoC is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated May 9, 1994 [or as subsequently amended]. If any parts, measurement frequencies or sampling requirements contained in this General Permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the certificate of coverage. Contact the Winston-Salem Regional Office prior to any sale or transfer of the permitted facility. Regional Office staff will assist you in documenting the transfer of this CoC. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning the requirements of the General Permit, please contact Jim McKay [919 733-5083, extension 595 or iames.mckav@ncmail.netl. Sincerely, for Coleen H. Sullins cc: Central Files Winston-Salem Regional Office / Surface Water Protection NPDES file 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 512 North Salisbury Street, Raleigh, North Carolina 27604 Phone: 919 733-5083 / FAX 919 733-0719 / Internet: www.ncwaterquality.org An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper Onc NorthCarolina !2atiira/Iji STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NCG500000 CERTIFICATE OF COVERAGE NCG500611 TO DISCHARGE NON -CONTACT COOLING WATER, COOLING TOWER AND BOILER BLOWDOWN, CONDENSATE AND SIMILAR WASTEWATERS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Interface FABRIC, Inc. is hereby authorized to discharge from a facility located at Interface FABRIC, Inc. 304 E Main Street Elkin Surry County to receiving waters designated as the Yadkin River in subbasin 30702 of the Yadkin River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage shall become effective August 1, 2007. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 23, 2007. ‘76 for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Interface FaeRic" NICOLE JOHNSTON ENVIRONMENTAL MANAGER JANUARY 29, 2007 CHARLES H. WEAVER, JR. N.C. DENR / DWQ / NPDES UNIT 1617 MAIL SERVICE CENTER RALEIGH, N.C. 27699-1617 Dear Mr. Weaver: Enclosed, please find the permit renewal application for NPDES Permit # NCG500611 which also includes Biocide 101 Forms and Material Safety Data Sheets for the following chemicals added for treatment for Outfall #1: Accu-Tab white calcium hypochlorite tablets, liquid alum, and dense soda ash. Should you have any questions regarding the attached renewal, please feel free to contact me at 336-526-0383. Sincerely, Nicole Johnston Environmental Manager Cc: Mike Rose, InterfaceFABRIC, Inc. Wendy Porter, Interface, Inc. 304 East Main Street, P.O. Box 530, Elkin, NC 28621 t. 336-526-0383; f. 336-526-2037 email: nicolejohnston@interfacefabric.com interfacefabric.com ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Alan W. Klimek, P.E., Director NOTICE OF RENEWAL INTENT Application for renewal of existing coverage under General Permit NCG500000 Existing Certificate of Coverage (CoC): NCG500 to I (Please print or type) 1) Mailing address* of facility owner/operator: c Company Name - Yl-�e�r u� I h) k , , We Owner Name ZbA. 1 ccSA- A�,,,-C. Street Address 361 Ec $ r Aljl City El k l'l State IV C-- ZIP Code a2i110 o� l Telephone Number 3 3 .5a (4 -- (538 3 Fax: 33 (o- 5 2 (D " 0 7 Email address n i CfW-. • JoM -1-on @ .1n-leJi ac Yckio ri c. (`biV * Address to which all permit correspondence should be mailed 2) Location of facility producing discharge: Facility Name Saw, CV) o,io U Vey Facility Contact Street Address City State ZIP Code County Telephone Number Fax: Email address 3) Description of Discharge: a) Is the discharge directly to the receiving stream? ❑ Yes rig.No (If no, submit a site map with the pathway to the potential receiving waters clearly marked. This includes tracing the pathway of the storm sewer to the discharge point, if the storm sewer is the only viable means of discharge.) b) Number of discharge outfalls (ditches, pipes, channels, etc. that convey wastewater from the property): c) What type of wastewater is discharged? Indicate which discharge points, if more than one. bt Non -contact cooling water Outfall(s) #: ❑ Boiler Blowdown Outfall (s) #: Page 1 of 3 NCG500000 renewal applicat; ❑ Cooling Tower Blowdown Outfall (s) #: Condensate Outfall (s) #: �.. Other Outfall (s) #: '- (Please describe "Other") to ec 'fcCQ.A-) ( 4X O V e E l u - 113 - - d) Volume of discharge per each discharge point (in GPD): Wf111i #001: 0 #002: N R #003: NA #004 ? 4) Please check the type of chemical [s] added to the wastewater for treatment, per each separate discharge point (if applicable, use separate sheet): KChlorine 0 Biocides 0 Corrosion inhibitors ❑ Algaecide Other 0 None 5) If any box in item (4) above [other than None] was checked, a completed Biocide 101 Form and manufacturers' information on the additive must be submitted to the following address for approval: NC DENR / DWQ / Environmental Sciences Section Aquatic Toxicology Unit 1621 Mail Service Center Raleigh, NC 27699-1621 6) Is there any type of treatment being provided to the wastewater before discharge (i.e., retention ponds, settling ponds, etc.)? 0 Yes $(No (If yes, please include design specifics (i.e., design volume, retention time, surface area, etc.) with submittal package. Existing treatment facilities should be described in detail. ) 7) Discharge Frequency: a) The discharge is: 0 Continuous 'Intermittent 0 Seasonal* i) If the discharge is intermittent, describe when the discharge will occur: ii) *Check the month(s) the discharge occurs: 0 Jan 0 Feb 0 Mar. 0 Apr 0 May 0 Jun 0 Jul 0 Aug. 0 Sept. 0 Oct. 0 Nov. 0 Dec. b) How many days per week is there a discharge? i\)OyL-Q— c) Please check the days discharge occurs: 0 Sat. 0 Sun. 0 Mon. 0 Tue. 0 Wed. 0 Thu. 0 Fri. 8) Receiving stream[s]: a) To what body or bodies of water (creek, stream, river, lake, etc.) does the facility discharge wastewater? If the site discharges wastewater to a separate storm sewer system (4S), name the operator of the 4S (e.g. City of��RlI Raleigh). -1 d t/a / l E k )f b) Stream Classification: elM( Page 2 of 3 NCG500000 renewal application Additional Application Requirements: The following information must be included in triplicate [original + 2 copies] with this application or it will be returned as incomplete. > Site map. If the discharge is not directly to a stream, the pathway to the receiving stream must be clearly indicated. This includes tracing the pathway of a storm sewer to its discharge point. > Authorization for representatives. If this application will be submitted by a consulting engineer (or engineering firm), include documentation from the Permittee showing that the consultant submitting the application has been designated an Authorized Representative of the applicant. Certification I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Mi Rrse... Title: S.Qj"IIIX' V IC.0-- P✓2SIdefli'�OpidQ ilfilj' i 14Ne (Signature of Applicant) (Dcite Sighed) North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) This Notice of Renewal Intent does NOT require a separate fee. The permitted facility already pays an annual fee for coverage under NCG500000. Mail the original and two copies of the entire package to: Mr. Charles H. Weaver NC DENR / DWQ / NPDES 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Page 3 of 3 STATE OF NORTH CAROLINA NPDES WASTEWATER APPLICATION FOR CHATHAM, INC. LOCATION PLAN SCALE: 1 "= 1 000' 203067 INTERFACE FABRICS GROUP \ 06 CHATHAM WASTEWATER NPDES MODIFICATION LOCUSDWG 203067 INTERFACE FABRICS GROUP \ 06 CHATHAM WASTEWATER NPDES MODIFICATION \ ELKIN.JPG WOOD6PD & CURRAN • Engineeong • Sc.vi.ric: • Oper:,it•cils DRYERS WET FINISH AND PLANT PROCESS 4 4 BIG ELKIN CREEK 1,350,000 GPO STEAM SETTLING 914,000 GPD FILTRATION BOILER FEED WATER CMI WOVEN FIBER PLANT 164.000 GPO OVERFLOW (10') DISCHARGE 002 (TO STORMWATER CULVERT) (INTERMITIENT) CFFlCE AC TO RETURN OFFICES (6 A F WASTEWATER TREATMENT PLANT CLEARWELL LARGE RESERVOIR 03 03 SMALL RESERVOIR 315.000 GPD A F 720,000 GPD COMPRESSOR COOUNG WATER CONDENSER COOUNG POND IMPINGER 72,000 GPD FLY ASH BASIN (101 [ ELKIN CITY WATER SUPPLY (BY REQUEST ONLY) STATE OF NORTH CAROLINA NPDES WASTEWATER APPLICATION FOR CHATHAM, INC. WATER USE SCHEMATIC A ` OODARD & CURRAI`