HomeMy WebLinkAboutNCC221097_Site Plan or Location Map_20220318SITE PLAN FOR:
GREENFIELD 27 FLEX AND INDUSTRIAL PARK
600 S. GREENFIELD PARKWAY
4101 WATERFIELD DRIVE AND
4501 WATERFIELD DRIVE
GARNER, NC
LOT ADDRESS AND SIZES
CURRENT
PROPOSED
PIN#
EXISTING ADDRESS
LOT S1 E
PROPOSED ADDRESS
LOT SIZE
1720935714
4001 WATERFIELD DRIVE
2.50 AC
600 S GREENFIELD PKWY
12,25 AC
1720937908
600 S GREENFIELD PKWY
5.52 AC
1720949398
500 S GREENFIELD PKWY
1 1.80 ACC
1720943105
4101 WATERFIELD DR
3.81 AC
4101 & 4501 WATERFIELD DR
14.99 AC
1720942401
4501 WATERFIELD DR
3.62 AC
CONDOMINIUM
27.25 AC
27.24 AC
SITE DATA BUILDING 600:
CURRENT OWNER. -
WHIT BROWN/AL GOODRICH WIGEON CAPITAL, LLC
2607 OBERLIN ROAD, SUITE 104
RALEIGH, NC 27608
WHIT@WIGEONCP.COM
(919)332-3887
SITE AREA: 12.25 ACRES
CURRENT ZONING: MXD-1
OVERLAY ZONING: NOT ADJACENT TO 1-40 OVERLAY
IMPERVIOUS SURFACE AREA:OSF
EXISTING: N/A .A
PROPOSED IMPERVIOU 311,340 SF ( 7.15 AC) ( 58.4 % OF SITE)
EXISTING USE: VACANT
PROPOSED USE: WAREHOUSE / FLEX
EXISTING BUILDING SF: N/A
PROPOSED BUILDING SF: TOTAL: 160,380 SF
(WAREHOUSE: 72,380 SF; FLEX 88,000 SF
TYPE OF BUILDING CONSTRUCTION: TYPE II-B
PARKING DATA:
WH 45% 72,380 /5000 =14
FLEX 55% 88,000 /500 =176
PARKING SPACES REQUIRED =190 PARKING SPACES PROVIDED = 190
Accessible Required: 6 Spaces (1 van)
Provided: 7 Spaces (2 van)
A PORTION OF PARCEL IS LOCATED WITHIN FLOOD ZONE'X', OUTSIDE OF ANY
SPECIAL FLOOD HAZARD AREA, AS SHOWN ON FEMA MAP #: 3720172000J,
FIRM PANEL: 1730J, DATED: 05/02/2006
SITE DATA BUILDING 600:
GARNER ENGINEERING:
LINEAR FOOTAGE OF PUBLIC STREETS
LINEAR FOOTAGE OF PUBLIC SIDEWALKS
NUMBER OF STORMWATER CONTROL MEASURES (SCM's)
CITY OF RALEIGH PUBLIC UTILITIES:
LINEAR FOOTAGE OF PUBLIC WATERMAIN (BY SIZE)
LINEAR FOOTAGE OF PUBLIC SEWERMAIN (BY SIZE)
LINEAR FOOTAGE OF PRIVATE WATERMAIN (BY SIZE)
LINEAR FOOTAGE OF PRIVATE SEWERMAIN (BY SIZE)
NUMBER OF WATER STUBS/TIES
NUMBER OF WATER METER(S) FOR DOMESTIC (BY SIZE)
NUMBER OF WATER METER(S) FOR IRRIGATION (BY SIZE)
NUMBER OF SEWER SERVICES (BY SIZE)
0 LF
1720 LF
(3) SHARED
0 LF
0 LF
0 LF 2
( 1 ) 2" WATER METER
TO BE CONFIRMED BY MEP
0
( 1 ) 6" SS SERVICES
TO BE CONFIRMED BY MEP
SITE DATA BUILDING 4101 and 4501 CONDOMINIUM:
CURR�TOWNER: 0
WHIT BROWN/AL GOODRICH WIGEON CAPITAL, LLC
2607 OBERLIN ROAD, SUITE 104
RALEIGH, NC 27608
WHIT@WIGEONCP.COM
(919)332-3887
SITE AREA: 14.99 ACRES
CURRENT ZONING: MXD-1
OVERLAY ZONING: NOT ADJACENT TO 1-40 OVERLAY
DISTURBED AREA: 10.7 AC
IMPERVIOUS SURFACE AREA:OSF
EXISTING: N/A
PROPOSED IMPERVIOUS: 282,210 SF 6.47 AC) (43.1 % OF SITE)
EXISTING USE: VACANT 1
PROPOSED USE: FLE : AND WAREHOUSE `.
EXISTING BUILDING SF: N/A
PROPOSED BUILDING SF:
4101 44,800SF
4501 57,600SF
PARKING DATA: 1 SPACE / 500 SF FLEX AND 1 SPACE / 5000 WAREHOUSE
4101 44,800
17.9 % WAREHOUSE= 8,OOO SF / 5000 = 2 SPACES
82% FLEX = 36,800 SF/ 500 = 74 SPACES
= 76 @ 4101
4501 100% FLEX = 57,600 /500 = 116 @ 4501
PARKING SPACES REQUIRED = 192 PARKING SPACES PROVIDED = 192
Accessible Required:
4101 3 SPACES INCLUDING (1) Van
4501 5 SPACES INCLUDING (1) Van
Required: 8 Required
Provided: 9 Spaces Provided (2 van)
A PORTION OF PARCEL IS LOCATED WITHIN FLOOD ZONE 'X', OUTSIDE OF ANY
SPECIAL FLOOD HAZARD AREA, AS SHOWN ON FEMA MAP #: 3720172000J,
FIRM PANEL: 1730J, DATED: 05/02/2006
SITE DATA BUILDING 4101 and 4501 CONDOMINIUM:
GARNER ENGINEERING:
LINEAR FOOTAGE OF PUBLIC STREETS
LINEAR FOOTAGE OF PUBLIC SIDEWALKS
NUMBER OF STORMWATER CONTROL MEASURES (SCM's)
CITY OF RALEIGH PUBLIC UTILITIES:
LINEAR FOOTAGE OF PUBLIC WATERMAIN (BY SIZE)
LINEAR FOOTAGE OF PUBLIC SEWERMAIN (BY SIZE)
LINEAR FOOTAGE OF PRIVATE WATERMAIN (BY SIZE)
LINEAR FOOTAGE OF PRIVATE SEWERMAIN (BY SIZE)
NUMBER OF WATER STUBS/TIES
NUMBER OF WATER METER(S) FOR DOMESTIC (BY SIZE)
NUMBER OF WATER METER(S) FOR IRRIGATION (BY SIZE)
NUMBER OF SEWER SERVICES (BY SIZE)
V
0 LF
615 LF
(3) SHARED
0 LF
0 LF
0 LF a
0 LF
2
( 2) 2" WATER METER
TO BE CONFIRMED BY MEP
0
( 2 ) 4" SS SERVICES
TO BE CONFIRMED BY MEP
us �aH
�E
0
er
z
y
o Q
WATERFIELD DR
VICINITY MAP
SCALE: 1 " = 800' SIGMA DR
DRAWING INDEX
1.
COVER
COVER
02.
L-70
EXISTING CONDITIONS PLAN
03.
L-80
DEMOLITION PLAN
04.
C-90
EROSION CONTROL PLAN - PHASE 1
05.
C-91
EROSION CONTROL PLAN - PHASE 2
06.
L-100
OVERALL SITE LAYOUT
07.
L-101
LAYOUT NORTH
08.
L-102
LAYOUT SOUTH
09.
L-200
OVERALL GRADING PLAN
10.
L-201
GRADING NORTH
11.
L-202
GRADING SOUTH
12.
L-300
OVERALL LANDSCAPE PLAN
13.
L-301
LANDSCAPE NORTH
14.
L-302
LANDSCAPE SOUTH
15.
L-400
SITE LIGHTING PLAN
16.
C-500
STORM DRAINAGE PLAN NORTH
17..
C-501
STORM, DRAINAGE PLAN SOUTH
18.
C-502
OVERALL UTILITY PLAN
19.
C-503
UTILITY PLAN NORTH
20.
C-504
UTILITY PLAN SOUTH
21.
C-600
SCM 'Ai PLAN AND DETAILS
22.
C-601
SCM 'A' ❑ETAILS - PLANTING
23.
C-602
SCM 'B' PLAN AND DETAILS
24.
C-603
SCM 'B' DETAILS - PLANTING
25.
C-604
SCM 'C' PLAN AND DETAILS
26.
C-605
STORM DRAINAGE DETAILS
27.
C-606
UTILITY DETAILS
28.
C-607
UTILITY ❑ETIALS
29.
C-608
EROSION CONTROL DETAILS
30.
C-609
EROSION CONTROL DETAILS
31.
C-610
EROSION CONTROL DETAILS
32.
C-611
EROSION CONTROL DETAILS
33.
L-700
SITE DETAILS
34.
L-701
SITE DETAILS
35.
A-101
600 BUILDING FLOOR PLAN
36.
A-102
4101 BUILDING FLOOR PLAN
37.
A-103
4510 BUILDING FLOOR PLAN
38.
A-201
600 BUILDING ELEVATIONS
39.
A-202
4101 BUILDING ELEVATIONS
40.
A-203
4510 BUILDING ELEVATIONS
GENERAL NOTES:
I . CONTACT THE NORTH CAROLINA ONE CALL CENTER PRIOR TO CONSTRUCTION.
1-800-632-4949
2. ALL ROOF DRAINS SHALL BE DIRECTED TO THE STORM DRAIN SYSTEM
3. PLEASE CONTACT THE ENGINEERING DEPARTMENT AT ENG- INS PECTIONS@GARNERNC.GOV
TO SCHEDULE A PRECONSTRUCTION MEETING PRIOR TO OBTAINING BUILDING PERMITS FOR
THIS PLAN.
4. PERMANENT AND TEMPORARY SIGNAGE REQUIRES AN APPROVED SIGN PERMIT PRIOR TO
INSTALLATION. SIGNAGE IS A SEPARATE SUBMITTAL, REVIEW AND APPROVAL PROCESS BY
THE PLANNING DEPARTMENT. SIGNAGE FOR THIS SITE MUST COMPLY WITH BOTH THE
MASTER SIGN PLAN FOR GREENFIELD AND THE TOWN OF GARNER SIGN ORDINANCE.
5. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF GARNER, CITY OF
RALEIGH, AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 1
6. TREE PROTECTION FENCE AND SILT FENCE CANNOT SHARE THE SAME POLE
TOWN OF GARNER CONDITIONS OF APPROVAL:
1. PRIOR TO ISSUANCE OF A BUILDING PERMIT, A PETITION FOR
ANNEXATION SHALL BE SUBMITTED TO THE PLANNING DEPARTMENT.
2. CROSS ACCESS AGREEMENT IS TO BE RECORDED WITH THE WAKE
COUNTY REGISTER OF DEEDS.
3. NCDOT APPROVAL REQUIRED FOR DRIVE PROPOSED AT
GREEN FIELDPARKWAY.
4. RECOMBINATION PLAT MUST BE RECORDED PRIOR TO ISSUANCE OF
BUILDING PERMIT.
5. ENGINEERING INSPECTION FEES TO BE PAID PRIOR TO SITE PLAN
APPROVAL
6. PRIOR TO THE ISSUANCE OF CERTIFICATE OCCUPANCY, ACCEPTANCE
PUNCH LIST FOR S. GREENFIELD PARKWAY TO BE COMPLETED AND
CONFIRMATION OF COMPLETION FROM DOT DISTRICT OFFICE
DELIVERED TO TOWN OF GARNER PLANNING ❑EPARTMENIT.
City of Raleigh Public
Utilities Department
Preliminary approval only. Does not constitute construction approval for
any proposed water or sewer main extensions. Valid only with signature of
a City of Raleigh Review Officer. This electronic approval may not be
edited once issued. Any modification to this approval once issued will
invalidate this approval.
SITE PLAN APPLICATION NUMBER:
SUP-SP-21-04
ATTENTION CONTRACTORS:
The Construction Contractor responsible for the extension of water,
sewer, and/or reuse, as approved in these plans, is responsible for
contacting the PUBLIC UTILITIES DEPARTMENT at (999)996-4540 at
least twenty four hours prior to beginning any of their construction -
FAILURE to notify bath City Departments in advance of beginning
construction, will result in the issuance of monetary fines, and require
reinstallation of any water or sewer facilities not inspected as a result of
this notification failure.
Consultants
HAGERSMIT�Fi
ARCHITECTURE
LANDSCAPE ARCHITECTURE
PLANNING
INTERIOR DESIGN
PO BOX 1308
300 SOUTH DAWSON ST
RALEIGH, NC 27602
919.821.5547
VAVW.HAGERSMITH.COM
COPYRIGHT 2021
if
NV5 ENGINEERS AND CONSULTANTS, INC.
3300 REGENCY PARKWAY SUIT 100
CARY, NC 27518
P; 919.858.1831 www.NV5.com
NC License # F-1333
formerly CALYX Engineers + Consultants
Seals
=� CERT. NO. o, - ~ '9
175 546
16/2.0214''
N!! i! 11 f 11 !!! 1! ! 11f1
NOT FOR CONSTRUCTION
Client
i Proiect
WIGEON�1
CAPITAL
WHIT BROWN/AL GOODRICH
WIGEON CAPITAL, LLC
2607 OBERLIN ROAD, SUITE 104
RALEIGH, NC 27608
WHIT@WIGEONCP.COM
(919)332-3887
GREENFIELD 27
GARNER, NC
SUP-SP-21-04
SITE PLAN REVIEW
SPECIAL USE PERMIT
EROSION AND SEDIMENT CONTROL
APPROVED PLAN
DATE
PERMIT NO. S-
Wake County Environmental Services
Sedimentation & Erosion Control
919-856-7400
E KVI RON MENTAL CONSULTANT SIGNATURE
Drawing Title
COVER
Revisions
Number
Description
Date
AResponse
to 1st Round of Garner Comments
08/31/21
aResponse
to 2nd Round of 9-27-21 Comments
10/14/21
a
41h Response to 3rd Round of 11-16-21 Comments
11/22/21
a
Revised Condition #7
12/16/21
TOTAL CURB AND GUTTER TO BE ADDED WITH IN PUBLIC RIGHT OF WAY FOR (2) LOTS: 170 LF
FAILURE to call for Inspection, Install a Downstream Plug, have
Permitted Plans on the jobsite, or any other Violation of CITY OF
RALEIGH STANDARDS will result in a Fine and Passible Exclusion from
future work in the CITY OF RALEIGH.
Drawn By SCS, SMK
Checked By SCS, JSL COVER
Date Issued 06/04/2020 1 Of