HomeMy WebLinkAboutNC0024333_Compliance Evaluation Inspection_20220310ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Brian J. Borne, Interim City Manager City of Monroe PO Box 69 Monroe, NC 28111 NORTH CAROLINA Environmental Quality March 10, 2022 SUBJECT: Compliance Evaluation Inspection Permit No. NC0024333 Monroe WWTP Union County Mr. Borne: On March 1, 2022, Roberto Scheller of this Office conducted a compliance inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to ensure compliance with permit requirements and conditions. The subject facility appeared to be well operated and maintained. We wish to thank the operating staff for their assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself or Roberto Scheller at (704) 235-2204 or roberto.scheller@ncdenr.gov. Enclosure: CEI Report DNORTH CAROLINA ap®rlmant of EnrrpN ee IOuant_y\ Sincerely, —DocuSigned by: `—A14CC681 AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) 1 21IIIIII 671 Transaction Code IN I 2 L NPDES yr/mo/day Inspection 3 I NC0024333 111 121 22/03/01 117 Type 1810I IIIIIIIIIII Inspector Fac Type 191S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved I 70I3 I 711 1 72 I N I 731 1 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES Hermit Number) Monroe WWTP 775 Treeway Dr Monroe NC 28110 Entry Time/Date 10:29AM 22/03/01 Permit Effective Date 20/08/01 Exit Time/Date 12:32PM 22/03/01 Permit Expiration Date 25/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Kyle P Ketchum/ORC/704-282-4612/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Kyle Ketchum,PO Box 69 Monroe NC 281110069//704-282-4612/7042832820 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Roberto Scheller of Inspector(s) Agency/Office/Phone and Fax Numbers ,--DO ned y"�o ti DWR/MRO WQ/707-235-2204/ �i,LA,r Date 3/9/2022 "-91 C2A007838943E... Sir ure of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date uocublgnea by. ��^�Q2 ���,�.� 3/10/2022 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day N C0024333 I11 121 22/03/01 17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Monroe WWTP NPDES permit was issued on August 1, 2020 and expires on January 31, 2025. Permit is for the continued discharge of 10.4 MGD into Richardson Creek located within the Yadkin -Pee Dee River Basin and classified as C waters. Speculative effluent limits have been provided by the NPDES Municipal Permitting Unit to Hazen & Sawyer, letter dated December 17, 2021, for the proposed flow of 15.4 MGD. The treatment facility is a 10.4 MGD extended air WWTP consisting of: - 2 Influent pump stations with 6 influent pumps - 2 Mechanical rotary screens - 10 MGD Flow EQ basin with proposed 15 MGD EQ basin to be constructed - 5 Activated sludge fine bubble aeration basins - 4 Secondary clarifiers - 6 Sand filters - Sludge drying beds (not in use) being used for sludge storage pads - Filter press - 2 Aerated sludge thickner tanks - 3 Aerated sludge holding tanks An application for Authorization to Construct (A to C) a 15 MGD equalization basin was sent to the NPDES Permit Unit by Hazen and Sawyer (Project #32138-013) and received on June 14, 2021. A to C was issued 9/23/2021 under A to C #02433A04. A 12-month compliance history review from January 2021 through December 2021 found violations of Weekly and Monthly BOD; Weekly violation for TSS; and Monthly violation for Flow during the month of February 2021. Records show that during month of Febuary 2021 facility reported 6.6 inches of rain. Page# 2 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ El El # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Annual report online @ City of Monroe Water Resources Department, FY 2021. Laboratory Are field parameters performed by certified personnel or laboratory? Yes No NA NE Page# 3 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ ❑ ❑ ❑ Comment: At time of inspection fecal incubator was at 44.6 degrees Celsius; BOD incubator at 20.1 degrees Celsius. Sample storage refrigerator recorded at 4.2 degrees Celsius. Samples analysis is performed by on -site laboratory (Cert. #206), Pace Analytical Services, LLC, and ETS. Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: At time of inspection influent sampler was recorded at 4 degrees Celsius. Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical • Are the bars adequately screening debris? • ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: Facility is equipped with 2 influent rotary screens. Debris is removed and disposed at landfill. Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Yes No NA NE Page# 4 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Equalization Basins Yes No NA NE Is the basin free of excessive grease? • ❑ ❑ ❑ Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? • ❑ ❑ ❑ Are float controls operable? • ❑ ❑ ❑ Are audible and visual alarms operable? • ❑ ❑ ❑ # Is basin size/volume adequate? • ❑ ❑ ❑ Comment: City to construct 15 MGD EQ basin. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? El El • El Are the diffusers operational? • El El El Is the foam the proper color for the treatment process? ■ El El El Does the foam cover less than 25% of the basin's surface? • El El El Is the DO level acceptable? El El El • Is the DO level acceptable?(1.0 to 3.0 mg/I) El El El • Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ • Page# 5 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Comment: At time of inspection effluent from #3 and #4 secondary clarifiers was clear with few visible suspended soilds. Pumps-RAS-WAS Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? Comment: Yes No NA NE • ❑ ❑ ❑ Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? • ❑ ❑ ❑ Is the filter surface free of clogging? ■ ❑ ❑ ❑ Is the filter free of growth? ■ ❑ El ❑ Is the air scour operational? • El El El Is the scouring acceptable? • El ❑ ❑ Is the clear well free of excessive solids and filter media? El El El • Comment: Disinfection -Gas Yes No NA NE Are cylinders secured adequately? ■ El El El Are cylinders protected from direct sunlight? • El El ❑ Is there adequate reserve supply of disinfectant? • El El El Is the level of chlorine residual acceptable? • ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? • El ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. • El El El 7782-50-5)? If yes, then is there a Risk Management Plan on site? • El El El If yes, then what is the EPA twelve digit ID Number? (1000- - ) 1000 001 10435 If yes, then when was the RMP last updated? 08/21/2021 Comment: De -chlorination Yes No NA NE Page# 6 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: At time of inspection flow was recorded at 7.65 MGD. Yes No NA NE Gas • ❑ ❑ ❑ • ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ ❑ ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • El El El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El El representative)? Comment: Facility is equipped with two composite samplers. At time of inspection effluent sampler #1 was recorded at 1 degree Celsius and sampler #2 recorded at 4 degrees Celsius. At time of inspection effluent was clear with no visible suspended solids. Solids Handling Equipment Yes No NA NE Is the equipment operational? • El El El Is the chemical feed equipment operational? • El El El Is storage adequate? • ❑ ❑ ❑ Page# 7 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Solids Handling Equipment Is the site free of high level of solids in filtrate from filter presses or vacuum filters? Is the site free of sludge buildup on belts and/or rollers of filter press? Is the site free of excessive moisture in belt filter press sludge cake? The facility has an approved sludge management plan? Comment: Filter belt press was in operation at time of inspection. Drying Beds Is there adequate drying bed space? Is the sludge distribution on drying beds appropriate? Are the drying beds free of vegetation? # Is the site free of dry sludge remaining in beds? Is the site free of stockpiled sludge? Is the filtrate from sludge drying beds returned to the front of the plant? # Is the sludge disposed of through county landfill? # Is the sludge land applied? (Vacuum filters) Is polymer mixing adequate? Comment: Drying beds are used for storage of dewatered sludge. Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • El ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Standby Power Yes No NA NE Page# 8 Permit: NC0024333 Inspection Date: 03/01/2022 Owner - Facility: Monroe WWTP Inspection Type: Compliance Evaluation Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 9