Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0015491_NOD-PC-2022-0029_20220307
ROY COOPER. Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Darren A. Hackett, Heir Russel Harrison Hackett Heirs 2518 Race Track Road Sophia, NC 27350 NORTH CAROLINA Environmental Quality March 7, 2022 SUBJECT: Notice of Deficiency (NOD-2022-PC-0029) Compliance Evaluation Inspection Permit No. WQ0015491 Caraway Speedway WWTF Randolph County Dear Mr. Hackett: On February 22, 2022, Division of Water Resources staff person Caitlin Caudle conducted a schedule compliance inspection of the subject facility. Darren Hackett, ORC, was present during the entire inspection. A review of records, treatment system, and irrigation fields was completed. The irrigation system had been winterized and was not viewed in operation. This review reflected noncompliance with the subject permit. DWR correspondence Notice of Violation and Notice of Intent to Enforce dated August 30, 2021 (tracking number NOV-2021-PC-0437 and NOV-2021-PC-0435) was hand delivered after being returned to the Office. The Civil Penalty Assessments issued to date were discussed, and the most recent Notice of Violation and Notice of Intent to Enforce. The following deficiency was noted: 1. Per Permit Condition IV.9 "an annual representative soil analysis ... shall be completed on each irrigation site listed in Attachment B." A soil analysis was not completed for the 2020 calendar year. This is a violation of the subject permit. NORTH D E Dopartmem of ln.imnmomni au.i` North Carolina Department of Environmental Quality Division of Water Resources Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 Please review the attached inspection report for additional comments and observations. If you have any questions regarding this notice please contact me or Caitlin Caudle at the letterhead address or phone number, or by email at lon.sniderncdenr.gov or caitlin.caudle©ncdenr.gov. Sincerely, DocuSiiggned by: 145B49E225C94 EA Lon T. Snider, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ-WSRO Enc: Inspection Report Cc: Randolph County Environmental Health (electronic copy) WSRO Electronic Files Laserfiche File WQ0015491 LD_E NORTH CAROLINA Department of Environmental quaky North Carolina Department of Environmental Quality j Division of Water Resources Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 336.776.9800 Compliance Inspection Report Permit: WQ0015491 Effective: 06/19/18 Expiration: 04/30/22 Owner : Russell Harrison Hackett Heirs SOC: Effective: Expiration: Facility: Caraway Speedway WWTF County: Randolph Region: Winston-Salem Contact Person: Darren A Hackett Title: Heir Phone: Directions to Facility: Rt. 52. to Rt. 64E through Lexington, to old Lexington Rd. Left at Carraway sign left at green farm Rd. straight across stop sign onto old country farm Rd. to Race track Rd. left System Classifications: SI, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 02/22/2022 Primary Inspector: Caitlin Caudle Secondary Inspector(s): Entry Time 10:05AM Exit Time: 12:15PM Phone: 336-776-9699 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Wastewater Irrigation Facility Status: E Compliant Not Compliant Question Areas: ▪ Miscellaneous Questions ▪ Record Keeping ▪ Storage (See attachment summary) ▪ Treatment Treatment Filters ▪ End Use -Irrigation Treatment Disinfection Page 1 of 6 Permit: WQ0015491 Owner - Facility: Russell Harrison Hackett Heirs Inspection Date: 02/22/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On February 22, 2022, Division of Water Resources staff person Caitlin Caudle conducted a schedule compliance inspection of the subject facility. Darren Hackett, ORC, was present during the entire inspection. A review of records, treatment system, and irrigation fields was completed. The irrigation system had been winterized and was not viewed in operation. This review reflected noncompliance with the subject permit. DWR correspondence Notice of Violation and Notice of Intent to Enforce dated August 30, 2021 (tracking number NOV-2021-PC-0437 and NOV-2021-PC-0435) was hand delivered after being returned to the Office. The Civil Penalty Assessments issued to date were discussed, and the most recent Notice of Violation and Notice of Intent to Enforce. The following deficiency was noted: 1. Per Permit Condition IV.9 "an annual representative soil analysis ... shall be completed on each irrigation site listed in Attachment B." A soil analysis was not completed for the 2020 calendar year. This is a violation of the subject permit. The following items of concern were noted: A. Mr. Hackett stated that the irrigation had not been calibrated this permit cycle. Per Permit Condition 111.6 "all irrigation equipment shall be tested and calibrated at least once per permit cycle. Calibration records shall be maintained at the facility for a period of no less than five years, and shall be made available to the Division upon request." Ms. Caudle recommended that the irrigation system be calibrated as soon as possible. B. The current designated back-up ORC has not completed the required continuing education hours or paid the license renewal fee. Per Permit Condition 111.2 "... the Permittee shall designate and employ a certified operator in responsible charge (ORC) and one or more certified operator(s) as back-up ORC(s)." Per 15A NCAC 08G .0200 a new back-up operator must be designated within 120 days of a position vacancy. C. A few trees were down in the irrigation zones and several large holes and breaks in drip lines were present during the inspection. This was also noted in the 2019 compliance inspection. Permit Condition 11.1 states "the subject non -discharge facilities shall be effectively maintained and operated at all times..." Please repair the drip lines before first use this year and conduct regular inspections to ensure the drip lines are maintained properly. D. The lab results for effluent monitoring listed nitrate (NO3) as nitrate + nitrite (NO2+NO3). The work order for analysis lists NO3 only and Attachment A requires NO3 be analyzed. Ms. Caudle recommended that Mr. Hackett contact the testing company to ensure that the proper analysis is being completed. Other observations: • Solids have never been removed from the septic tank, but it is checked once a year when the system is prepared for seasonal use. Mr. Hackett stated that since the system has been installed residuals have not been removed from the septic tank. • An Operations and Maintenance Plan and Spill Plan were in the office and at the pump house. • A chainlink fence surrounds the irrigation field and treatment system. • The lab report were reviewed for 12/2020, 4/2021, 7/2021, and 11/2021. The ND values reported were reviewed. Ms. Caudle recommended that Mr. Hackett report ND values as <reporting limit. For example, the reporting limit for ammonia is 0.10 mg/L. If the lab results report ammonia as ND, ammonia would be reported on the NDMR as <0.10. • The system is always run in manual mode. A computer is used to operate the system and it is not stored in the pump house. • The system is completely off unless someone is at the pump house. High water alarms are present on the storage tanks and mixing tank that will send a call out, but only if the computer is connected to the system. • The system will send a warning when there is 20% high flow in a system, and cut off when there are 50% high flows. • Wastewater will be treated when the septic tanks is approximately half full, and irrigation will occur when there is Page 2 of 6 Permit: WQ0015491 Owner - Facility: Russell Harrison Hackett Heirs Inspection Date: 02/22/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine enough effluent in the storage tanks. At the time of inspection the low water float was visible. • This system only serves the office building and bathrooms that serve part of the grandstand. • The infield restrooms are served by a subsurface septic system. • The system was winterized and shut off on 12/2/2021. • Mr. Hackett will check the system before and after an event. • All provided monitoring reports were sent to non-discharge.reports@ncdenr.gov by Ms. Caudle on 2/23/2022. • The two 12,000 gallon tanks are the connected storage tanks. The tanks are underground. • All wastewater gravity feeds to the septic tank, which gravity feeds into the dose/mixing tank. • The 2018 and 2019 soils reports were reviewed. • A water meter is not present to measure the influent that enters the system. Mr. Hackett measures the volume in the recirculation/sand filter dose tank before and after events at the facility. Page 3 of 6 Permit: WQ0015491 Owner - Facility: Russell Harrison Hackett Heirs Inspection Date: 02/22/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Infiltration System Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Single Family Drip Recycle/Reuse Activated Sludge Drip, LR Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Comment: System was winterized and did not see it in operation. Treatment Filters Is the filter media present? Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and filter media? Does backwashing frequency appear adequate? Comment: Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? Yes No NA NE • Yes No NA NE ▪ ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑•❑ ❑ ❑ • ❑ ❑ ❑ ❑• Yes No NA NE ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 6 Permit: WQ0015491 Owner - Facility: Russell Harrison Hackett Heirs Inspection Date: 02/22/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? Comment: Soil samples were not collected in 2020. End Use -Irrigation ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Yes No NA NE Page 5 of 6 Permit: WQ0015491 Owner - Facility: Russell Harrison Hackett Heirs Inspection Date: 02/22/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are buffers adequate? Is the cover crop type specified in permit? Is the crop cover acceptable? Is the site condition adequate? Is the site free of runoff / ponding? Is the acreage specified in the permit being utilized? Is the application equipment present? Is the application equipment operational? Is the disposal field free of limiting slopes? Is access restricted and/or signs posted during active site use? Are any supply wells within the CB? Are any supply wells within 250' of the CB? How close is the closest water supply well? Is municipal water available in the area? # Info only: Does the permit call for monitoring wells? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Are monitoring wells damaged? Comment: • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ Page 6 of 6