Loading...
HomeMy WebLinkAboutSW1210902_Supplement-EZ Form_20220215SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Broadpointe Industrial Facility 2 Project Area (ac) 7.09 3 Coastal Wetland Area (ac) 0 4 Surface Water Area (ac) 0.006 5 1 Is this project High or Low Density? Both High and Low Density 6 1 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting (RWH) 0 18 Green Roof 0 19 Level Spreader -Filter Strip (LS-FS) 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale Dry Pond StormFilter Silva Cell Bayfilter Filterra 0 22 0 23 0 24 0 25 0 26 0 FORMS LOADED DESIGNER CERTIFICATION 27 IName and Title: Organization: Street address: Daniel Hyatt 28 Wade Trim Inc. 29 53 North Market Street 30 City, State, Zip: Asheville, NC 28801 31 Phone number(s): 8282551197 32 Email: rhyatt@wadetrim.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. CARe i �OO � D 5 c�'OF`,�'Y + Lu 7d i * +- No. 1405 y. ♦�`. QL �`' 'T a. y1 ignafu a of Designer 02/10/2022 Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 LID 1 4 Type of SCM N/A Sand Filter Dispersion Flow 5 Total drainage area (sq ft) 1092049 273174 818875 6 Onsite drainage area (sq ft) 1092049 273174 818875 7 Offsite drainage area (sq ft) Total BUA in project (sq ft) New BUA on subdivided lots (subject to permitting) (sq ft) 0 0 0 8 223399 sf 216801 sf 6599 sf 9 N/A N/A N/A 10 New BUA not on subdivided lots (subject to permitting) (so 223399 sf 216801 sf 6599 sf 11 Offsite BUA (sq ft) sf sf sf 12 Breakdown of new BUA not on subdivided lots: Parking (sq ft) 97872 sf 91274 sf 6599 sf Sidewalk (sq ft) 4965 sf 4965 sf sf Roof (sq ft) 120562 sf 120562 sf sf Roadway (sq ft) N/A N/A N/A Future (sq ft) N/A N/A N/A Other, please specify in the comment box below (sq ft) N/A N/A N/A 13 New infiltrating permeable pavement on subdivided lots (sq ft) N/A N/A N/A 14 New infiltrating permeable pavement not on subdivided lots (sq ft) N/A N/A N/A 15 Existing BUA that will remain (not subject to permitting) (sq ft) N/A N/A N/A 16 Existing BUA that is already permitted (sq ft) N/A N/A N/A 17 Existing BUA that will be removed (sq ft) N/A N/A N/A 18 Percent BUA 21 % 79% 1 % 19 Design storm (inches) 1.0 in 1.0 in N/A 20 Design volume of SCM (cu ft) N/A 13417 cf N/A 21 Calculation method for design volume N/A Simple Method N/A ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): LD1 designed to have sufficient dispersion at pipe outlet; sized for 10 yr storm event. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per. 1 003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) N/A 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 JAre curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (% ) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: SAND FILTER 18 SHWT elevation (fmsl) 2046.5 ft 19 Type of sand filter (open or closed) Open 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) N/A 22 Is this sand filter designed to attenuate peak flows? No Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 16238 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber fmsl 2057.50 26 Area of the sediment chamber (square feet 1823 sf 27 Physical depth of the sediment chamber inches 12 in 28 Ponding depth in the sediment chamber, above any permanent pool inches 36 in 291 Elevation of top of weir between chambers (fmsl) 2059.5 I Sand Chamber 30 Volume that can be retained in the sand chamber cubic feet 12845 cf 31 Bottom of the sand chamber fmsl 2059.50 32 Area of the sand chamber(square feet 1823 sf 33 Physical depth of the sand chamber inches 18 in 34 Ponding depth in the sand chamber, above the sand surface inches 36 in 35 Elevation of the bypass device (fmsl) 2062.5 36 Type of bypass device Inlet 37 Mechanism for distributing flow over the sand surface Level Weir 38 Sand specification for sand chamber ASTM C-33 39 Depth above underdrain pipe (inches) 18 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes 42 Will clean -out pipes be capped? Yes