Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0038141_Regional Office Historical File Pre 2018
Pat McCrory Governor North Carolina Department of Environmental Quality November 23, 2015 Mr. William B. Grant, CIP Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 Subject: Permit No. WQ0038141 Kensington Wastewater Collection System Extension Permit Union County Dear Mr. Grant: Donald R. van derVaart Secretary in accordance with your application received November 17, 2015, we are forwarding herewith Permit No. WQ0038141 dated November 23, 2015,.to Union County Public Works (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permi Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee, It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina. General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1698 \ Fax 704-663-6040 \ Customer Service 1-877-623-6748. Internet: www.ncwaterquality.org An Equal Opportumty \ Affirmative Action Employer — Made in part by recycled paper Urban County Public Works Permit o. WQ003 4 I you need additional information concerning this or via e-mail at barrylove@ncdenr.gov. SImerely, ichaeI Parker, Regional Supervisor dater Quality Regional Operations Section oresville Regional Office iyision of Water Resources, NCDEQ cc: Brian D. mith, . (electronic copy) Regional Office Files Water Resources Central Files PER (electronic copy) atf Page of p contact Barry Love at (ri 423S 4 STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works Union County for the construction and operation of approximately 1,455 linear feet of 8-inch gravity sewer to serve 20 single family homes as part of the Kensington project, and the discharge of 5,700 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received November 17, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996,as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and -limitations contained therein. { Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0038141 Permit Issued: November 23, 2015 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Union County Public Works is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Union County Public Works Twelve Mile Creek Wastewater Treatment Plant in accordance with Permit Number NC0085359. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the .Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special. Conditions identified below.. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 5,700 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)1 II. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.5 143-215.1(d3)) 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T,0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403, If an individual permit is not required, the following performance criteria shall be met; [15A NCAC 02T .0108(b)]; Page 4 of 8 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. • h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any 55O and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S.143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following. a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pumpsizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12,1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S.143-215.1(b)] Page7of8 PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: FAST TRACK SEWER ENGINEERING CERTIFICATION Union County Public Works WQ0038141 Kensington November 23, 2015 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain. the wastewater collection system permitted herein or portions thereof. Printed Narne, Title Signature Date ENINEERtS CERTIFICATION as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe (1 „� periodically, weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Final Partial (include description) Certification Comments/Qualifiers (attach if necessary);. NC DWR - Water Quality Regional operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 cc7 icnn r Avg 11nn1 c,�a cnnn 0 LL Z z -J CL z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD owner/Permittee: la. Union County Full Legal Name (company, municipality, HOA, ut lity, etc.) 1b, William Grant, CIP Program Manager Application Number: (to be completed by DWR) Signing official Name and Title (Please review 15A NCAC 2T .0 06 (b) for authorized lc. The legal entity who will own this system is; Individual ❑ Federal ❑ Municipality ® State/County ❑ Private ld. 500 North Main Street, Suite 400 'le Mailing Address 1f. NC State ... lh 1704) 296-4239 Telephone 2. Protect (Facility) Information: 2a. Kensington _ Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. William Grant, PE i. (704) 296-4232 Facsimile gning officials Partnership ❑ Corporation ❑ ClifW Monroe City 1g. 28112 Zip Code 1j. William. ant E-mail 2b, Union Counties M ;sOi1C unfoncountync.gov County Where Project is L Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 1704) 296-4239 Phone Number Project is New 2. Owner is ( Public (skip to Item 6(3)) ed William.grant c�7a unioncoun E-mail an existing permit) If Modification, Permit No,: © Private (go to Item 2(a)) 2a. If private, applicant will be. El Retaining Ownership (i.e. store, church, single office, etc, Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc. - go to item B(26)) Union Coun Wastewater Treatment Faccli 4a. Twelve„Mile Creek WW Name- off TF 5a Union County 5b 8" Gravity Owner of Downstream Sewer1R.eceiving Sewer Size.1© Force Main 6, The origin of this wastewater is (check all that apply) EJ Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park School 0 Restaurant Q Office nc gov NRI 3W1 REGIONAL OF-FIC E 2b. If sold, facilities owned by a (must choose one) O Public Utility (Instruction D) ❑ Homeowner Assoc./Developer (Instruction E) ater From This Project 4b, NC0085359 WWTF Permit No. WQ0029160 Permit # of Downstream Sewer (In • Retail (Stores, shopping centers) O Institution 0 Hospital © Church ❑ Nursing Home O Other (specify); 7. Volume of wastewater to be allocated or permitted for this particular project: 5,700 *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequ ❑ Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0103 to determine if a permit is required) 100 % Domestic/Commercial % Industrial (Attach Description °/© Other (Attach Descriirtion) gallons per day nt permits that connect to this line ETA 10-14 APPLICATION Fa ' 4 of"6 z Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7), Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T ,0114 (f). 95 gpd/bedroom * 3 bedrooms/home * 20 homes = 5,700 gpd 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) New Gravity or Additional Force Main 1,455 New gravity 11, Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) z 0 Pump Station Location ID: (self chosen - as shown on planslmap for reference) Longitude; Latitude: z NNW Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator w1MTS Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator w/MTS 12. 'v lilt the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment faci [ Yes El No If Yes, permit number of 2nd treatment facility (RO — if 'yes' to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the GravitkSewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ElYes [I)No If No, complete and submit the Variance/Alternative Design Request (VADC1©-141 application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. Y? FIA 10-14 APPL Page 5 of 6 4. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? L1 Yes E] No N/A Sedimentation and Erosion Control Plan? E Yes ID No El N/A Trout Buffer Waiver? El Yes D No El N/A Stormwater? Yes D No Li N/A 15. Does this project include any high priority lines (15A NCAC 02T .0402(2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: [1] and provide details: 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Narne) la. William Grant, attest that this application for Kensington has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all requited parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance. with North Carolina General Statutes 143-215,6A and 143-215.68, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 rnisdcmean tih rnjjyde a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, Signing OfficialOfficaI Signatu Vribiekget, Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) /, Brian Smith, attest that this application for Kensington has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for The Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which May include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Brian D. Smith, PE. Professional Engineer Name 2b, Urban Design Partners, LLC, Engineering Firm 2c, 1318 Central Avenue, Suite EG Mailing Address 2d. Charlotte City 2e. NC 2f. 28092 State Zip 2g. (704) 334-3303 2h, (704) 334-3305 2i, br)an@urbandesi9npartners.com Telephone Facsimile E-mail NO PE Seal, Signature 8. Date I:TA 10-14 APPLICATION Page 6 of 6 USGS U.S. DEPARTMENT OF THE INTERIOR U.S, GEOLOGICAL SURVEY too The National Mp US Top° §s71 .70 5559 53ITCr .57 science On e changing nvoild 30' 4'7`34r 520 CATAWBA NE QUADRANGLE SOUTH CAROL1NA-NORTH CAROLINA 7,5-M(NUTE SERIES S21 71 817(1 EITICI FEET iSc) 522 E.074.7.§8 .71 .10 lt59 51.3n" .57 80345' SCALE 1124 000 5 r.s s kii Wan:RS § 7 10510 sou n wrote, 1000 MOD § 0.55 55 . , 3.§i§83 Tirma 7717— "7 219 -70550- 00505 79 "I" 7E8 a coo sour 057700551, 10 !FEE, aiDiRTM 4.31E0IC055VS DATUM 550' taAft 73§§3 map 11313433434E10555555'to rymiairin with 5555, (Fassimilai !smarms§ §§a Timm P70181, Stsmird, 70§F, A r§m§Dasas 0550 yammisir with Das imatiorl 0 +An 4:443311141 7 Dia Produced by the United Strokes Geologira1 Survey 1105550 Amaii,a ()Mom or §783 Warid &maim, %Dim, §8§§8.8 e051705545, pywr 5 taitameias VA§ 550i003381. Tmairmas Marriaim, 7n, Dry iX773 foot tiasai 10,05, CarMins 7,o,001005500s55001551505555. CariMria 1700,0555005e Swam, 17183 T§§431311343 13 1103 55 RV: aricumant. 87100,833300may ba yleneraliami 5501 OD mom Scaim Privaie Visa, 141114131444 aiwaramm, re0100a00,73 may 551§78,§ savvm. 03444,113331133443131341 beam mamma prissie 10,455 It'ITTF, iii7(1§7 taainaa„. , , , , 37§1§§177 133.3.1 NYTIINTITLII,Y— • — —.— . a . a HaFisnal Siyiliagrayam rosA.343°:,, 703§ CaDiCars... „...— .„.. . . .—Naiirmai 7,3m5la0 13331443334111341 Bassidariss .„ . Akiatitaa Diyittlasi Mia aviiminia DM §917 . 2011 RCAF/ CLASSIFICATION iispirmaav a§ DaianDi 44,34-4,4 5o34131134,1y §-May kayak! Pasrti Sara§ kammate Ravi, F8 077. Piwas (1 MeV Amy, 33,4 7'12' §). 388.3 ay§ 3 7 win DID! mairiasID 8818 8430,4311.8NORT55 SE3.71,31364 AT Damara DV 54.881" am3345575530 m , 3 j0Wo5500o0,,n SW4110111361 Ca443331313 '7 ! a 7 Van Fiark 55 441444ty CATAWBA NE, SC -NC 2014 September 29, 2015 Address Points Parcel Hooks Parcel Easements Parcels Highways Roads 1:8,841 0 0.075 0,15 0.3 mi 0 0„1 0 2 0.4 km ScxiEsn, HERE, UeLornne, USGS, Onternnp ,ncremeni P Corp. NRCAN, Esn Japan, METL Esn China (Hors} Kong', Esn ThalanJ), Mdpinyindra, J QpcnStr tMap contributors, and the GbS un y KENSINGTON FAST TRACK APPLICATION COVER LETTER PROJECT No. 15-011 PREPARE) BY: URBAN DESIGN PARTNERS 1318-;6 CENTRAL AVENUE CHARLOTTE, NORTH CAROL INA 28205 (704) 334-33©3 KENSINGTON FAST TRACK APPLICATION COVER LETTER PROJECT No. 15-011 APPLICANT The Ryland Group, Inc. Hamilton Stolpen 3600 Arco Corporate Drive Suite 200 Charlotte, NC 28273 704-972-4501 ENGINEER Urban Design Partners Brian D. Smith, P.E. 1318-E6 Central Avenue Charlotte, NC 28205 704-334-3303 704-334-3305 (fax) PROJECT LOCATION The site is located along Kensington Drive in Union County, NC, roughly 1,900 linear feet southwest of the intersection of Kensington Drive (SR 1305) and Waxhaw-Marvin. Road (SR 1301). PROJECT DESCRIPTION Ryland Hornes is constructing a 20 lot single-family neighborhood on the 20.3-acre site. All lots will be served by public sewer lines that connect to an existing public sewer main in the southwestern corner of the lot. The sanitary sewer design for this project includes the installation of 1,455-1inear feet of 8-inch PVC and ten (1.0) proposed manholes. The estimated wastewater flow was calculated. using an average daily flow of 95 gallons per day per bedroom. Each home will have 3 bedrooms and there are 20 homes. The estimated wastewater flow is 5,700 gallons per day. Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Union County Project Name for which flow is being requested: Kensington More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Twelve Mile WWTP b. WWTP Facility Permit #: NC0085359 All flows are in MGD c. WWTP facility's permitted flow 6.0 d. Estimated obligated flow not yet tributary to the WWTP 1.7637 e. WWTP facility's actual avg. flow 3.76 f. Total flow for this specific request 0.0057 g. Total actual and obligated flows to the facility 5.5294 h. Percent of permitted flow used 92.16 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Millbridge 3.646 1.458 0.0981 0.2171 0.3152 1.1428 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. *Y Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of FTSE 08-I3 n Statement. Grants certify t.o the best ofmy knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and If plus all attached planning assessment addendums for which I am the responsible party. Signature of this form -eptance of this wastewater flow, Date Page FTSE PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station Listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 of, 3 FTSE 08-13 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/2966-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Kensington Subdivision We are sending you: n Copy of letter 0 Plans 0 Prints 0 Shop Drawings EK Other TRANSMITTAL ESV L L =. REOIa .L OF10E Description Cover Letter Fast Track Application Copy of Fast Track Application Flow Tracking Form 480.00 Check (Application Fee These are transmitted as checked below: Date: 11 /12/1 5 ® For approval Q, For your use 0 As requested I J For review and comments Remarks: Signed: Received by: Date: • Central Files: APS _ SWP 11/23/2015 Permit Number WQ00313141 Permit Tracking Slip Program Category Status Protect Type Non -discharge Active New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1.00 Individual • Primary Reviewer Permit Contact Affiliation bany.Iove Coastal SWRule Permitted Flow 5,700 Facility Facility Name MajorlMlnor Region Kensington Minor Mooresville Location Address County Union Facility Contact Affiliation Owner Owner Name Owner Type Union County Government - County Owner Affiliation Cindy Coto Dates/Events 500 N Main St Monroe NC 28112 Orig Issue 11/23/2015 App Received Draft Initiated 11/17/2015 Scheduled Issuance Public Notice Issue Effective 11/23/2015 11/23/2015 Regulated Activities Requested /Received Events Subdivision Wastewater collection Outfa ll Expiration Additional Information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasln PAT MCCRORY Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN urces D rector TAL QUALITY August 24, 2016 Ms. Crystal Panico, New Development Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification Acknowledgement Project: Kensington Permit No. WQ0038141 Permittee: Union County Public Works County: Union Dear Ms. Panico: The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on August 22, 2016. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings, for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://portal.ncdenr.org/web/wq/swp/ps/es/pnoc from the Collection Systems Applications page.. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr. Brian D. Smith, P.E., (Urban Design Partners, 1318-E6 Central Avenue, Charlotte, NC 28205) Central Files MRO State of North Carolina I Environmental Quality I Water Resources 610 E. Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 Internet www•nedenr.gov [TTEE: FERMIT#: PROJECT: ISSUE DATE: FAST TRACK SEWER ENGINEERING ON Union County Public Works VVQQO3814l Kensington November 23,2OI5 xv{i4(,)S This projectshaN not heconsidered complete nor allowed kzoperate inaccordance vv�th Condition 7of this permit until the Division has received this Certification and all required supporting documentation, It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall sutvact the Pernnit1ee to appropriate enforcement actions. The Pe,mittee is responsible for tracking all partial certifications up until afinal certification |sreceived, 4Final Certification shall beacomplete set ofrecord drawings and design calculations regardless ofwhether partials have been submitted. PERMITTEE'S CERTIFICATION |' the undersigned agent for the Henmittee,hereby state that this project hasbeenconstrucedpursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information tothe Permittee, and the Permittee is prepared tooperate & maintain the wastewater collection system permittepherein o[portions thereof, Crysta|Panico Development Program Manager Printed Name, Title Signature EmGINEER'sOcRTIFI , |, _ _Brian 'Srn�h ' as a dulyregistered Professional Engineer in the State of North Carolina, having been authorized to observe /D/ periodically, J | weekly, | l full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A N[A[ OZT; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February IZ' 1998 a: applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 2'ZQ0Uasapplicable; and other Supporting materials. North Carolina Professional Engineer's Seal w/signature & clate: Final | } Partial (include description) Certification Comments/Quallifiers (attach if necessary): NCDVVR—Water Quality Regional Operations Section G18East Center Avenue, Suite 3O1'Mooresville, NC281I5 Mooresville Ken|ona|Office Phonp: (704>66,-A-1W9 p4x-/rnd)'(;:zq'rouo UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Regarding: Engineer's Certification for Kensington We are sending you: Copy of letter Plans Other Copies Date No. Description 1 8/12/16 Record Drawings TRANSMITTAL Date: 8.18/16 Prints I Shop Drawings 1 8/17/16 Engineer's Certification for Sewer (Permit ''Q0038141 These are transmitted as checked below: For approval For your use As requested Remarks: Signed] Received by: Date: For review and comments