HomeMy WebLinkAboutWQ0037941_Regional Office Historical File Pre 2018North Carolina Department of Environment and Natural Resources Pat McCrory Governor August 17, 2015 Mr. Charles P. O'Cain, P.E. Union County 500 N. Main Street, Suite 500 Monroe, NC 28112 Subject: Permit No. WQ0037941 Keffer Kia Offsite Sanitary Sewer & Watermain Extension Wastewater Collection System Extension Permit Union County Dear Mr. O'Cain: Donald R. van der Vaart Secretary In accordance with your application received July 31, 2015, we are forwarding herewith Permit No. WQ0037941 dated August 17, 2015, to Union County (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §1.43-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or Iimitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 \ Fax 704-663-6040 \ Customer Service 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer — Made in part by recycled paper Union County Permit No. WQ003794 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2 .43 or via a -mail at barry.love@ncdenr.gov.. Sincerely, for S. Jay Zimmerman, P.G. Director, Division of Water Resources by Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDENR cc: John H. Ross, P.E. (electronic copy) Regional Office Files Water Resources Central Files PERCS (electronic copy) Page 2 of 8 ATA NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Union County Union County for the construction and operation of approximately 1,429 linear feet of 8-inch gravity sewer to serve an auto dealership with hand wash and car wash as part of the Keffer Kia Offsite Sanitary Sewer & Watermain Extension project, and the discharge of 4,750 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received July 31, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the cified conditions and Imitations contai.aed therein. for S. Jay Zimmerman, P.G. Director, Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0037941 Permit Issued: August 17, 2015 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Union County is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Union County Crooked Creek Wastewater Treatment Plant in accordance with Permit Number NC0069841. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1SA NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 4,750 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] II. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.5 143-215.1(d3)1 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .01101 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: Page 4 of 8 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control.grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.;or b. Any 6SOand/or spill over 1,00Ogallons; or c. Any S6Oand/or spill, regardless nfvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the, initial verbal report. Overflows and spills occurring outside normal business hours may also be reported tothe Division ofEmergency Management attelephone number (80D)858'0368nr(9l9) 733'3308. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part | of Form [S'6SO (or the most current Division approved form) within five days following first knowledge ofthe occurrence. This report must outline the actions taken orproposed to betaken to ensure that the problem does not recur. Part || of Form CS -SS[} (or the most current Division approved form) can also he completed to show that the S5Q was beyond control. [G.S. 143' 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters ofthe State. (15ANCA[02T.0180(b)l 7' Upon completion ofconstruction and priorto operation of these permitted facilities, the completed Engineering Certification fn,nn attached to this permit shall he submitted with the required supporting documents tothe address provided mnthe form. Acomplete certification isone where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Perrni\teetoappropriate enforcement actions. if the permit is issued to o private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided asapplicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) ofthe wastewater collection system extension. Final record drawings should be clear mmthe plans or on digital media (CD or DVD disk) and are defined aothe design drawings that are marked up or annotated with after construction infn/nnotWm and show/ required buffers, separation distances, material changes, etc, b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet vve||, and force maim, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis, if portable power source nrpump is dedicated to multiple stations, nn evaluation ofall the pump stations' storage capacities and the, rotation schedule of the portable power source or pump, include travel timefromes,shall beprovided. Page 6 of 9 Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .01161 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] . 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .01161 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)1 11. In the event that the wastewater collection facilities fail' to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page7of8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Union County PERMIT#: WQ0037941 PROJECT: Keffer Kia Offsite Sanitary Sewer & Watermain Extension ISSUE DATE: August 17, 2015 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom.. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and. design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION i, , as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe ([1 periodically, 0 weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal /signature & date: QI Final 0 Partial (include description Certification Comments 'Qualers (attach if necessary): NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville„ NC 28115 ., ... rn, rnnn z z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Appifcation Number: (to be completed by DWR) 1. Owner/Permlttee: 1 a. Union Coun Full Legal. Name (company, municipality, HOA, utility, etc. 1 b. Charles P. O'Cain, PE„ Development Program Manager Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b1 for auth 1 c. The legal entity who will own this system is. 0 Individual ICI Federal Q Municipality Sta 1 d. 500 N. Main Street, Suite 500 Marling Address. 1 f. North Carolina State 1 h. '704-296-4244 1 i. 704-296-4232 zed signing officials) ounty El Private Partnership © Corporation 0 Other (specify): RECEIVED/NCDENRJDWR Telephone Facsimile 2. Protect (Faciilltvj Iptorr align: 2a. Kefler Kia Otfsite Sanitary Sewer & Watermain Extension Brief Project Name (permit will refer to this name) Contact Person: Charles P. ©Vann, P.E., Development Program Manager le. Monroe City 1g. 28112 Zip Code ocain.co.un'ion.nikliVRESVILLFF REGIONAL, OFFICE E-mail 3 2b. Union County Name and Affiliation of Someone Who Can Answer Questions About this .Application 3b, 704-295.4244 Phone Number 2. Owner is Public (skip to Item B(3)) 0 Privet 3c. ocain@co.union.nc.us WOIROs E-mail rtion, Permit No:: go to Item 2(a)) 2a, If private, applicant will be. Retaining Ownership (i.e. store, church, single office, etc.) or [� Leasing units (lots, townhomes, etc. - skip to item B(3)) El Selling units (lots, townhomes, etc. - go to Item B(2b ) Union County Owner of Wastewater Treatment Facility (WWTF) Treating Was 4a. Crooked Creek WWTF Name of WWTF 5a, Union County 15b, 5 inch_ Owner of Downstream Sewer 'Receiving Sewer Size 6„ The origin of this wastewater is (check all that apply): © Residential Subdivision © Apartments/Condominiums 0 Mobile Horne Park © School © Restaurant 0 Office 2b. If sold, facilities owned by a (must choose one) © Public Utility (Instruction D) [� Homeowner Assoc./Developer (Instruction E) ater From This Project 4b. NC0069841 WWTF Permit No. Gravity 35c. NC15970 rce Main Permit # of Downstream Se Retail (Stores, shopping centers) Institution [] Hospital Church © Nursing Home 0 Other (specify): 7. Volume of wastewater to be allocated or permitted. for this particular project: 4,750 'Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: ( 100% Domestic/Commercial { %© Industrial (Attach Description) % Other (Attach Descrintion) gallons per day © Pump Station. Outfall or Interceptor Line where flow will be per teed in subsequent permits that connect to this line © Flow has already been allocated in Permit No. w. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 023 .0303 to determine if a permit is required) FTA 10-14 APPLICATION Pa 4 of 6 Z z 0 0 Z Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T 0114 for, the value in Item B(7) Aft /OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use; data in accordance with 15A NCAC 2T ..0114 (f). Dealership: 3,000 + 500 + 1,250 = 4,750 gpd (24 fixture'125 gpd/fixture=3,0O0 gpd) + (Hand Wash - 2'250 gpd=5009pd) + (carwash —1 bay "1250 g without recycling) 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) 1,429 ravity or Addttfonal Force Main New Gravity 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: Longitude: _ Design Flow (MGD) self chosen - as shown on plans/map for reference) Latitude: Operational Point Power Reliability Option GPM @TDH 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length; Pump Station Location ID: (self chosen - as showrl on plans/map for reference) Longitude: Design Flow (MGD) Latitude: Operational Point Power Reliability Option GPM @TDH 1 permanent generator w/ATS; Force Main Size Force Main Length 2 portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to f directed to another treatment facility? © Yes No if Yes, permit number of 2nd treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains 2T as applicable? (latest version), the GresignyCriteria (latest version) and 15A NCA Yes ❑ No h If No, complete and submit the Variance/Alternative Design Request (VADC 10-14) application and supporting documents for review. Approval of the request Is required prior to submittal of the Fast Track Application and supporting documents. FTA (Ci-14 APP'TCATION Pa;e. 5 of 6 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetiand/Strearn Crossings - General Permit or 401Certification? 0 Yes D No El N/A Sedimentation and Erosion Control Plan? D Yes LI No 1Z1 N/A Trout Buffer Waiver? El Yes l3 No N/A Stormwater? D Yes El No N/A 15, Does this project include any high priority lines (15A NCAC 02T .0402 2 ) involve aerial lines, siphons, or interference manholes)? These lines will be considered high prIorrtand must be checked once every six months Check if Yes: LI and provide details: 1 a. Signing 0 c at Signature Date Owner/Permittee's Certification: (Signature of Signing Official and Project Name) Charles P. O'Cain, P.E„ attest that this application for Keffer Kia Offsite Sanitary Sewer & Watermain Extension has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Notes In accordance with North Carolina General Statutes 143-215,6A and 143-215.6S any person who knowingly makes any ;false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil p alties up to $25,000 per violation. ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY (1) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T 0305 z 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, John H, Ross, P,E, ,atfest that this application for Keffer, Kia Oftsite Sanitary Sewer ,,& Waterrnain Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 1,13-215,64and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10000 as well as civil penalties up to $25,000 per violation, 2a. John H, Ross, P,E. Professional Engineer Name 2b, Eagle Engineering Inc, Engineering Firm 2c. 2013A Van Buren Ave Mailing Address 2d. Indian Trait 2e. NC 2f. 20879 City State Zip 2g. 704882-4222 2h. 866-775-0329 2i. iross@eagleoniine,net '74,N,iiiil,iiiio Telephone Facsimile E mail '--- NC PE Seaarl Slature SEAL CO 7: •4959 N. OUS FTA 10- 4 APPLICATION Page 6 of 6 us. k srme.TMttN°ceAt' TUEOrniitm4 h�an_ Cy 1AMikAeW SW6'tt. Y3le�Rr+Y +N vv7+aeinw t!" xnwsa SCOJ,E i'NY*0 eixprvµ Mk�x +O.�F'i »wrm�cemurv�at�.a w.*d:rx srµ w:umE &ay^vm *T tp r,Ani#ANST MAIM CA*411,M013rtt01.CO, VU,16 Cvrir#^XM PAICFRPµ NC EXISTING SANITARY SEWER SYSTEM PROPOSED SANITARY SEWER EXTENSION 2013 Van. Buren Ave., Suite A Indian Trail, NC 28079 (704) 882-4222 www.eagleonline.net PROPOSED SITE USGS MAP OF THE KEFFER KIA OFF -SITE SEWER ALE: ©B NAME: KEFFER KIA CLIENT: LAND GROWTH LLC LOCATION: HIGHWAY 74 OB NUMBER: 5259 NROE, N f.1 Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources FIow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Union County Project Name for which flow is being requested: Keffer Kia More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Crooked Creek b. WWTP Facility Permit #: NC0069841 All flows are in MGD c. WWTP facility's permitted flow 1.90 d. Estimated obligated flow not yet tributary to the WWTP 0.4370 e. WWTP facility's actual avg. flow 1.19 f. Total flow for this specific request 0.0048 g. Total actual and obligated flows to the facility 1.6318 h. Percent of permitted flow used 85.88 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the Pump Station (Name or Number) Helmsviile Firm Capacity,* MGD (A) Design Average Daily FIow** (Firm / pf), MGD Approx. Current Avg. Daily Flow, MGD (B) (C) Obligated, Not Yet Tributary Daily FIow, MGD 0.508 0.2032 0.142 0.0610 WWTP: (D)=(B+C) (E)=(A-D) Total Current Flow Plus Obligated Flow Available Capacity*** 0.2030 0.0002 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of FTSE 08-13 III. Certification. Statement: I Charles P. O'Ca.itr certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established, policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which l am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Date FTSE PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < O. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and _ MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 ofA3 FTSE 08-13 FORM WSCAS 0f3-13 WATERSHED CLASSIFICATION AT' AC Hi" TENT FOR SEWER SYSTEMS ficant Name Union County Public Works Professional Engle eer Name John H. Ross, P.E. °cation j Keffer Kia Offsite Sanitary Sewer & erain Ex in ca Firm Name Eagle Engineering, Inc. �Riv=er Name of W Paerbadyl' County Basin A South Fork Crooked Creek Union Yadkin if unnamed, indica Waterbody eam Index N©. 1 �17-20 2 o X", were X is the named waterbody to which the unnamed tributary joins_ 1certify that as a Registered Professional Engineer In the State of North Carolina that / have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the hest of my knowledge and belief PE Seal, Signature and Date *** ENE) )F FORM WSCAS 0ft-13 FORM: ° ''SCAS Oki-ta3 Waterbody Classification C Page i of 1 Project Narrative RECENEDINCDENRIDWR vv0 R OS MOORESviLLE REGIONAL OFFICE 5269 Keffer Kia Off -site Sanitary Sewer and Watermain Extension The proposed project consists of a sanitary sewer extension and watermain extension to the future Keifer Kia project site in Union County, NC on Highway 74 (Independence Blvd), The proposed sanitary sewer extension is designed to convey the sanitary sewer effluent from the future Keifer Kia development to an existing Union County Public Works 8" sanitary sewer main running along Chamber Drive adjacent to Highway 74 . • How is calculated as follows: o Water Demand a Auto Dealership — 3,000 gpd I' Hand wash stall — 500 gpd • Irrigation — 2,909 gpd • Car wash — 1,250 gpd • Total Water Demand — 7,659 gpd o Sanitary Sewer Demand • Auto Dealership — 3,000 gpd • Hand wash stall — 500 gpd • Car Wash — 1,250 gpd • Total Sewer Demand — 4,750 gpd UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N,C. 28115 Attention: Regarding: Sanitary Sewe We are sending you: Copies 7/6/15 7/9/15 These are trans o serve Keffer Kia �VQRCS MOORESVILLE REGIONAL . )M° iC TRANSMITTAL Date: 7/28/15 0 Copy of letter 0 Plans C Prints U Shop Drawings Other No, Description Cover Letter Fast Track Application Copy of Fast Track Application Flow Tracking Form $480.00 Check (Application Fee Stream Classification Form d as checked below: For approval D For your use 0 As requested 0 For review and comments Remarks: Signed: Received by: Date:. Central Files: APS _ SWP 8/17/2015 Permit Number WQ003794i Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer ba rry.love Coastal SWRuIe Permitted Flow 4,750 Facility Version Permit Classification 1.00 Individual Permit Contact Affillatlon Facility Name Keifer Kia Offsite Sanitary Sewer & Watermain Ext. Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affillatlon Cindy Coto 500 N Main St Monroe NC 28112 Orig Issue 8/13/2015 Scheduled App Received Draft initiated Issuance Public Notice Issue Effective Expiration 7131 /2015 8/17/2015 8/17/2015 Regulated Activities Retail Wastewater collection Outfall Requested /Received Events Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin Water Resources Envirommen¢all Quality February 13, 2017 Ms. Crystal Panico, New Development Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification .Acknowledgement Project: Keffer Kia C)ffsite Sanitary Sewer & Waterrnain Extension. Permit No. WQ0037941 Permittee: Union County Public Works County: Union Dear Ms. Panico: ROY COOPER. MICHAEL S. REGAN S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering. certification with record drawings for the subject sewer extension project on. February 13, 2017. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted,. you will be notified of any items of .non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party, If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable, Form PNOCF can be downloaded from httpa/Tortal.nedenr.org/weblw /sw / s/'cs/ rnoc frown the Collection Systems Applications page. Should you have any question Pi ase do not hesitate to contact inn at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr, Johnny Houston Ross, P_E., (Eagle Engineering, 2013A Van Buren. Avenue, Indian Trail, NC 28079) Central Files -2 Nothing Compares;. :uscaldn<tttrikarortmental Qtuaid)!! Water Resources l "ar rC ckald ' Regoesta! Operations rr FAST TRACK SEu!ER ENGINEERING CERTIFICATION P ERMITTEE: Union County PERMIT #: WQ0037941 PROJECT: Keffer Kia Offsite Sanitar Sewer &Waterrnain Extension ISSUE DATE: January 28, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permittedrein or portions thereof, ClItyS '4 L- -0 • PA N r ig-e E Lye ep,,ENr "44 6LA-si Printed Name, Title rums 4ea- Signature D ENGINEER'S CERTIFICATION Johnny Houston Ross I, , as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe (1 periodically, E weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996.as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: 0 Final LJ Partial (include description Certification Corrrrnents/Qualifiers (attach if necessary): NC DWR - Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Mooresville Regional Office Phone: (704) 663-1699 FAX: (704)-633-6040