Loading...
HomeMy WebLinkAboutWQ0035297_Regional Office Historical File Pre 2018Nortn Carolina Department of Environment and Natural Resources NCDENR Division of Water Quality Beverly Eaves Perdue Coleen H Sullins Governor Directcr April 14, 2011 Mr, Mike Garbark, Assitant Drector of Engineering Union County Public Works 500 N. Main Street Monroe, NC 28112 Dear Mr, Garbark, Dee Freeman Secretary Subject Perrn t No. VV00035297 Stallings Municipal Park Wastewater Collection System Extension Union County, North Carolina. In accordance with your complete application received on April 1, 201-1, we are forwarding herewith Permit No, WQ0035297 dated April 14, 2011, to Union County Public Works for the construction and operation of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; .2) the Division of Water Quality's (Division) Gravity. Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permitteels responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional cr replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office Location, 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 \Fax: (704) 663-6040 1 Customer Service- 1-677-623-6743 Internet: ivrww.ricwatergalilyorg iNlorThCarolina Yaturatly Mi. Garbar'2 Page ANrTI 14, 201 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 83 linear feet of, inch gravity sewer and the discharge of 2,,000 gallons per day of domestic wastewater into the exiStin�c sewerage system in conformity with 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, the Divisions Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and rapproved by the Department of Environment and Natural Resources and considered a pan of this permit. The sewage and wastewater collected by this system shall be treated in the Crooked Creek TP (NPDES No.NC0069841) prior to being discharged into the receiving stream, Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works, Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS09954. If any parts, requirements, or limitations contained in thus permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. .3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If -an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 28 .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled sQ as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. A copy of the construction record drawings shall be maintained on file by the Per nrittee for the life of the wastewater collection facilities Failure toabide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina. General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities.. 10. The issuance of this permit shall not exempt the Perm'ittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local,, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B 0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a, Any process unit failure, due to known or unknown reasons; that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 14th day of April, 2011. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0035297 3 Fast Track Enq0neerinq Permit No. WQ0025297 April 14, 2011 ©wnerrANQCSNWVTP Mike Garbark Union County 500 North Main St, Suite 500 Monroe, NC 28112 3c on PE Marcus J. King Site Solutions 2320 West Morehead Street Charlotte, NC 28208 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if pontablr generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project ges to project be arly ed on tecord dwings or in written summary form, Permit Chan modificationsthe are requiredshould for anw� clechangesidentifiresulting he in nonr�corx�plranrae vulth this pernrit regulations r minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. L ENGINEER'S CERTIFICATION Partial Q' Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (06 periodically, [I weekly, 0 full time) the construction of Stallings Municipal Park, a Union County project for the Permitted, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, '1996 as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mans adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineers seal,, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certificatons up until a final certific wastewater flow made tributary to the wastewater collection system extension prior tc`w Engineer's Certification shall be considered a violation of the permit and shall subject enforcement actions. n is received. Any mpetion of this Permittee to appropriate _,,,, E TAB KEY TO MOVE FROM FIELD TO FIELD! nerl , _____ ittee: _. Union Count _Public Works ___ _ Full Legal Name (company, municipality„ HQA, utility, etc) 1b. Mike Garbark, PE, Assistant Engineering Director Application Number: (to be completed by DWQ) Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) lc. The legal entityY who will own this system is ❑ Individual ❑ Federal Municipality ❑ State&County ❑ P ld. 500 N Main Street 6L Mailing Address z z 0 z North arolina 1 h, 704-296-4239 Telephone 2. Project (Facility) info rt ation:: 2a, Stallings Municipal Park in _ Brief Project Name (permit will refer to this name) Contact Person: ViGarbark, PE, Assistant Erineering Director Mike Name and Affiliation of Someone Who Can Answer Questions About this Application ate Partnership 0 Corporation ❑ Other (specify): le. Monroe City fig, 28112 3b, 704-296-4239 Phone Number N. ...._..,_u 1. Project is New Q Modification (of an existing permit 2. Owner is t! Public (skip to item B(3)) 2a, If private, applicant will be: ❑ Retaining Ownership (i.e. store, church, single office, etc) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) Zip Code mike arbark co.unron.nc.0 E-mail 2b. Union County Where Project is Located 3c. mikegarbark a�7co,union.nc,us E-mail odification, Permit No.., Private (go to Item 2(a)) 2b. If sold, facilities owned by a (must choose cane 0 Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (Instruction D) Union County Public Works Owner of Wastewater Treatment Facility (VWVTF) Treating Wastewater From This Project 4a. Crooked Creek Wastewater Treatment Plant 4b, NC0069841 Name of WWVTF VWVTF Permit No, Union County i5b. 8" Gravity cw 'W00001158 Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main E Permit # of Downstream The origin of this wastewater is (check all that apply): 0 Residential Subdivision El Apartments/Condominiums O Mobile Home Park ❑ School O Restaurant 0 Office i. 704-296-4232 Facsimile nstruction E) % DomesticlCommercia % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) 100 %/o Other (specify): Restrooms ?. Volume of wastewater to be allocated or permitted for this particular project 2,000 gallons per day *Do not include future flows or previously permitted allocations 8, If the permitted flow is zero, indicate why: ❑ Retail (Stores, shopping centers) ❑ Institution ❑ Hospital ❑ Church Nursing Home Other (specify): Park El Pump Station, Outfall or Interceptor Line where fiow will be permitted in subsequent permits that connect to this line Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer permit is required) ith no new flow expected (see 15A NCAC 02T .0303 to determine if FI''A 1.2 07 ide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for e value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 8 plumbing fixtures x 250 gpd/fixture = 2,000 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 6 82.76 gravity Ci 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) W D Pump Station Location ID (self chosen - as shown on plans/map for reference) ATION (CONTIN Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator w/MTS Force Main Size • Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) RMIT 1NFORM Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator wIMTS Force Main Size Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) _ W 11. m Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator w/MTS Force Main Size Force Main Length i 12. ■ Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ►� Yes D No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12107 liping permits/ certificatk3ns been submitted for approval for the system or project to be served? !Stream Crossings - General Permit or 401 Certification? El Yes E No N/A edimentation and Erosion Control Plan? Yes 0 No © N/A Stormwater?Yes d No © N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: © and provide details 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Mike Garbark, PE, attest that this application for Stallings Municipal Park has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. la. Signing Official Signature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY; Z TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 l 0. \ Date 2. Professional Engineer's Certification: (Signatu of Design Engineer and Project Name) 1, Marcus J. Kin_g. PE, attest that this application for Stallings Municipal Park has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation; to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these matenais under my signature and seal signifies that 1 have reviewed' this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Marcus J. King, PE Professional Engineer Name 2b. Site Solutions Engineering Firm 2c. 2320 West Morehead Mailing Address 2d. Charlotte City 2g, 704-521-9880 2h, 7044-52'1-8955 Telephone et Facsimile 2e NC 2f. 28208 Zip 2i. mking@sitesolutionspa.com E-mail NC PE Seal, Signature & Date FTA12/07 80°43'00" W NATIONAL GEOGRAPHIC TOP©! map printed on 07/13/10 from "Stallings Municipal Park.tpo" 0°42'00" W 80°41'00" W 00" W WGS84 80*40'00°" z WGS84 80°40'00" W MN TN 7'h° 07/13/10 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Stallings Municipal Park We are sending you: 1 Copy of letter 1 Plans 0 Prints Shop Drawings El Other TRANSMITTAL Description Non -Discharge Permit Application Copy of Non -Discharge Permit Application Flow Tracking Form $480.00 Check (Application Fee These are transmitted as checked below: Date: 3/24/11 For approval 0 For your use E As requested For review and comments Remarks: Signed: Received by: Date: State of North Carolina Department of Environment and Natural Resources Dfwision of Water Quality Flow Tracking/Acceptance for Sewer Extension. Permit Applications (FTS E —10/07) Project Applicant Name: Minion County Project Name for which, flow is being requested: Stallings Municipal Park More than one E7SE1O!°'07 m pumps stations along the router he required r• a single prt )f the If'`JG'°TP Is not responsible fier all 1. Complete this section only ifyou are the owner of the wastewater treatment plant a. WWTP Facility Name: Crooked Creek b. WWTP Facility Permit #: C0069'841 c.. WWTP facility's permitted flow d.. Estimated obligated flow not yet tributary tc e. WWTP facility's actual avg. flow f. Total flow for this specific request g, Total actual and obligated flows to the fac h. Percent of permitted flow used 'WTP All flows are in MGD 1.90 0..28'76 0.98 0.0020 12696 66,82 .l. Complete this section for each pump station you are responsible for along the route o, proposed wastewater flow,. List pump stations located between the project connection point and the WWTP Pump Station Name None Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD "ertification Statement: Mike Garbark .. _ , certify that, to the best of my dge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity. related sanitary sewer overflows or overburden any downstrerun pump station en route to the receiving, treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1: and 11 for which 1 am the responsible party. Signature of this form indicates acceptance of wastewa Central Files: APS^ SWP^ 04/12/11 e mit Number WQ0035297 Permit Tracking Slip Program Category Non -discharge Status Project Type Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer dee.browder Coastal SW Rule Permitted Flow Facility Facility Name Stallings Municipal Park Location Address Owner Permit Contact Affiliation Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Owner Affiliation Mark Eugene Tye 500 N Church St Ste 500 Dates/Events Orig Issue 04/12/11 Monroe App Received Draft Initiated 03/28/11 Scheduled Issuance Public Notice Issue NC . 281124730 Effective Expiration 04/12/11 04/12/11 Regulated Activities Re uested!Received Events Wastewater collection Additional information requested Additional information received Outfall NULL 04/01/11 04/01/11 Waterbody Name Stream Index Number Current Class Subbasin ee c: Subject: Dee, MikeGarbark@co.union.nc.us Wednesday, April 20, 2011 9:59 AM Browder, Dee PBrown@co.union.nc.us Stallings Park - Permit No WQ0035297 We inadvertently permitted this under our name (Union County) and the sewer is 6" in diameter. We do not accept ownership of sewer infrastructure smaller that 8" in diameter but didn't pick up on it until the permit was processed by you guys. Rather than re -permit the infrastructure under another name, Stallings has agreed to upsize the sewer from 6" to 8". We are fine with that. Do you need to reissue a permit replacing 6" with 8" on Page 2 of the permit? Or can you acknowledge via email since nothing else is changing but the sewer diameter? Thanks, Mike G Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 "Browder, Dee" <dee.browder@ncdenr.gov> wrote: To: "Mickey, Mike" <mike.mickey(ancdenr.gov>, "MikeGarbark@co.union.nc.us" <MikeGarbark(aco.union.nc.us>, "PBrown©co.union.nc.us" <PBrown@co.union.nc.us> From: "Browder, Dee" <dee.browder(&ncdenr.gov> Date: 03/17/2011 02:29PM cc: "LarryDavis@co.union.nc.u_s" <LarryDavis@co.union.nc.us>, Marcus King <mking(asitesolutionspa.com> Subject: RE: Stallings Park MRD concurs with Mike. If someone wants us to process an application and issue a permit number we will. Thanks Dee From: Mickey, Mike Sent: Thursday, March 17, 2011 2:21 PM To: MikeGarbark@co.union.nc.us; PBrown@co.union.nc.us Cc: LarryDavis@co.union.nc.us; Browder, Dee; Marcus King Subject: RE: Stallings Park t rob rinare, Tial„hilY I:ack Er Per pit Pio )1110 0036 0 led Jt 2, 2011 OwnistArSOCSAITIVIT) MOOT) St ki biker., a tastiaL 0 a is iiDE Mike Citureark Jung it eases Union County Lianie Labineuriniiii 500 North Mein Sr, 'Meier 500 Vitro tiered Avenue Muerte inD 26 )2 Mame Crap NOT 23029 Dombiete and submit, idyls farm to the permit issUtrig regional office with tna iii One copy ot the protect mooed drawings reran probIe views of sewer !inter') of itie te kr) rt system dideneron libupearting design ralciJiations (selected pumps, system SUINICe operating point, available storage ri portable generations) or storage greater than iongest east three dear outage ri option selected) ler any burns) islations permitted as no, t or this prayed 'Changes' to the project shock! be dearly bleidified on Me record drawings or in written summary foam peratdiii modifications are, regibred for aa,..; char gigs re:inertly:Lin norecomaitance with thisiipermit, rairialattorm or minimum (design galena , his protract eattili not ggigISICiaregl grir allowed to operate until gas tiginerreatic Cateriticalatig sing al required subsciding documentation neve been received by the Division. Therefore, it is highly recommended Mat this certification be sent in a meatier that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION Parbai 04 Final 1206,S i3S a dilly registered Professional Engineer in the state of North aarofina giaspaq been authorized to eb,serve perigideriatly, weekty, fu.11 time) the dionstruction of 'Sardis Corners, a Union County brayed ler 331 Perri hereby Tate that, to the best of ray abilities, due pare and diligence wiliS USEiiiC in the arisen/skim-I of the donstructitm bitch that the cianstruction was observed lig be Mr Of within isubstardraI compiiance, of inis parent' 151e, NOAC 2T the Division of Weber Qualifys iiDigesion) Gravity Sewer Minimum Design Criteria adopted February '12, 19S6 apipkettbIe„ Ilse Division's My -drawn Design Criteria for the Fasit-TracK Permitting of Pump Stations itInd Force Mains adopted June 1, 2000 as rimaiiratibler, and other supporting nanteriale Noah Caftans Protessionsi Engineer's seat signature, and date SEND THIS FOPM & SUPPORTING DOCUMENTATION VVI13 REQUIRED ATTACHMENTS, TO 111E FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE, WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVIt.,LE NC 2i3115 The Permittee is resporialide for tracking ail Fortin' itaiirtifickiiiitiOnS op until a final Gentile:shoe is received Any wastewater flow blade titulary to me WCistewater collection syster11 prior reciatiplelion be ibis Engineers Certification isbaIi corisislered a violation tat the permit arid313 suliject bike Perrnititee to appribririate enforcement actions