Loading...
HomeMy WebLinkAboutWQ0033241_Regional Office Historical File Pre 2018UNION COUNTY DEPARTMENT OF PUBLIC WORKS 500 North Main Street. Suite 500, Monroe, NC 28112 Phone: (7014)296421.0 • Fax: (704)296-4232 April 3, 2013 Ms. Dee Browder NC Dept. of Environment and Natural Resources Mooresville Regional Office 610 E. Center Avenue Mooresville, N.C. 28115 Ref: Ezzell Valley — Permit # WQ0033241, dated July 28, 2008 Dear Ms. Browder: Please void permit # WQ0033241, dated July 28, 2008. The proposed gravity sewermain will not be constructed as approved with this permit. There will be a new permit with a new name, different engineer and layout. If you have any questions don't hesitate to call me at (704) 296-4244. Thank you for working with us on this matter. Sincerely, Charles P. O'Cain, P.E. CPO/pwb Mr. Mike Garbark, Asst. Dir. of Public Works Union County 500 North Main Street, Suite 500 Monroe, NC 28112 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality July 29, 2008 Subject: Permit No. WQ0033241 Corrected Ezzell Valley Union County Public Works Wastewater Collection System Extension C-MU# 600-08-594 Union County, North Carolina Dear Mr. Garbark, In accordance with your application received on July 17, 2008, we are forwarding herewith Permit No. WQ0033241, dated July 28, 2008, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal OpportunitylAfiirmalive Action Employer — 50% Recycled/10% Post Consumer Paper N"oy�`1tCarolinz Naturally Mr. Garbark Page 2 July 29, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 9,027 linear feet of 8-inch gravity sewer and the discharge of 19,570 gallons per day of collected domestic wastewater into the Union County and Charlotte Mecklenburg Utility Department existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utility Department WWTP (McAlpine Creek NPDES No. NC0024970) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works. Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00054. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the WQCS00001 permit requirements If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Steven Miller, Charlotte -Mecklenburg Utilities Philip Edwards, Mecklenburg County Rusty Rozzell, LUESA Bradley Smith, RD Davis Consulting Engineers, PLLC Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of -wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21- .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. r4 . This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T..0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part i of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 29th day of July, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, ire Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033241. Corrected Fast Track Engineering Certification Permit No. WQ0033241 Corrected July 29, 2008 Owner/WQCS WWTP Mr. Mike Garbark Steve Miller Union County Public Works CMU 500 North Main Street, Suite 500 5100 Brookshire Blvd. Monroe, NC 28112 Charlotte, NC 28216 PE Bradley Smith RD Davis Consulting Engineers, PLLC 323 Indian Trail Road, North Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION ❑ Partial ❑ Final { , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Ezzell Valley, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Re: WQ0033241 - Ezzell Valley Subject: Re: WQ0033241 -,Ezzell Valley From: Dee Browder <dee.browder@ncmail.net> Date: Wed, 06 Aug 2008 10:45:08 -0400 • To: MikeGarbark@counion rc:us - Am sending out a corrected copy today , Thanks, Dee MikeGarbark@co.union.nc.us wrote: Dee,. Just following up on the discharge: amount for Permit No. WQ003.3241 - Ezzell Valley. Thedischarge in the permit reads 19,5705 gallons per day. It should read 19570 gpd. This may not seem like a big deal but the.developer of this subdivision is always looking for loopholes and threatening lawsuits. Should it be revised or can you amend it by email? The engineer for Newtown Garden is still curious if he can submit calculations on his wastewater permit based on a 'not yet approved' variance. I am hesitant to allow this unless you are willing to allow calculations not strictly adhering to T-2. They want to submit the variance and the flow application Simultaneously. Thanks Mike Garbark Mike Garbark, PE Assistant Engineering Director. Union County Public Works 500 N Main Street: Monroe, NC 28112, ADdv❑ 1 D 1 8/6/2008 10:45 A] Michael F. Easley, Governor ' William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality July 29, 2008 Mr. Mike Garbark, Asst. Dir. of Public Works Union County 500 North Main Street, Suite 500 Monroe, NC 28112 Subject: Permit No. WQ0033241 Ezzell Valley Union County Public Works Wastewater Collection System Extension C-MU# 600-08-594 Union County, North Carolina Dear Mr. Garbark, In accordance with your application received on July 17, 2008, we are forwarding herewith Permit No. W00033241, dated July 28, 2008, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper No `hCaroltna Aaturallri Mr. Garbark Page 2 July 29, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 9,027 linear feet of 8-inch gravity sewer and the discharge of 19,5705 gallons per day of collected domestic wastewater into the Union County and Charlotte Mecklenburg Utility Department existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utility Department WWTP (McAlpine Creek NPDES No. NC0024970) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works. Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00054. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the WQCS00001 permit requirements If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, / 4 /4.-- for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Steven Miller, Charlotte -Mecklenburg Utilities Philip Edwards, Mecklenburg County Rusty Rozzell, LUESA Bradley Smith, RD Davis Consulting Engineers, PLLC Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. I 4. This permit shall not be transferable. in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 29th day of July, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033241 3 Fast Track Engineering Certification Permit No. WQ0033241 July 29, 2008 OwnerJWQCS WWTP Mr. Mike Garbark Steve Miller Union County Public Works CMU 500 North Main Street, Suite 500 5100 Brookshire Blvd. Monroe, NC 28112 Charlotte, NC 28216 PE Bradley Smith RD Davis Consulting Engineers, PLLC 323 Indian Trail Road, North Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, ❑ weekly, ❑ full time) the construction of the Ezzell Valley, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum.Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: a. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Mike Garbarki P,E., Assistant Director of Pubi.e Works Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) Application Number: (to be completed by DVVQ) Q C o -.3.) .._J lc. The legal entity who will own this system is: ❑ Individual © Federal ❑ Municipality 0 1d. 500 North Main Street, Suite 500 Mailing Address North Carolina Z State 704296-4210 1 i. 704-296-4232 Telephone Facsimile 2 Project (Fac!!!'V) Inrformaticrrf: 2a. Ezzell Valle! Brief Project Name (permit will refs Contact Person: Mike Garbark, P.E. Name and Affiliation of Someone 3b. (7Q4.1 296-4239 Phone Number Project is New ❑ Modification (of an existing permit oun ❑ Private Partnership ❑ Corporation 0 Other (specify): 1e. Monroe City 1g, 28112 Zip Code mikegarbark@co.uniar.nc.us E-mmail 2b. Union County Where Project is Located o Can Answer Questions About this Application 3c. hike arbark cra.0 ion .nc.,us E- odiflcation, Permit No.: 2. Owner is Public (skip to Item B(3)) ❑ Private 2a, tf private, applicant will be: 0 Retaining Ownership (i,e. store, church, single office, etc.) 0 Leasing units (lots, townhomes, etc, - skip to Item B(3)) Selling units (lots, townhomes, etc. - go to Item B(2b)) Charlotte Mecklenburg Utilities Department 2(a)) 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction C) ❑ Homeowner Assoc/Developer (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, McAlpine Name of WWTF Union Co Public Works 5b. 12"' Gravity Owner of Downstream Sewer ;Receiving Sewer Size ❑ Force Main The origin of this wastewater is (check all that apply): Residential Subdivision 0 Apartments/Condominiums ❑ Mobile Home Park 0 School • Restaurant ❑ Office 4b. NC 0024970 Q 0022064 Permit # of Downstre Retail (Stores, shopping centers) © Institution ❑ Hospital ❑ Church ❑ Nursing Home • Other (specify): Volume of wastewater to be allocated or permitted for this particular project. *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: n 100 % Damestic/Commercial % industrial (attach description) I(RO, contact your Regional Office Pretreatment staff) % Other (specify): 570 gallons per day • Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this I 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA12/07 a r\, CI° -- • W "s ,D Y.Pump F Y. Z,. Z . ,I--, a re' , O. LL__...._.__.,......_._....._ Ili . -a; •' .-12. 1 9. Provide the wastewater flow calculations used the value in item B(7) AND/OR the design flow in determining the permitted flow in accordance with 15A NCAC 2T .0114 for for line or pump station sizing if a reduced or zero flow is being requested in 2T .0114 (b) and (c) must be supported with actual water or wastewater use (f). Item B(7). Values other than that in 15A NCAC data in accordance with 15A NCAC 2T .0114 103 homes x 190 gpd = 19,570 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 9027 New Gravity or Additional Force Main 8" Gravity — i • 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) (self chosen - as shown on plans/map for reference) Station Location ID Design Flow I Operational Point (MGD) GPM @TDH Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generator w/MTS Force Main Size Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) Design Flow I (MGD) I Operational Point i GPM @TDH Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generator w/MTS Force Main Size Force Main Length ............._... Pump Station Location ID.............._._.__.._.._.....---............_.......__.._..._....__.....�._-...-._..__.._........self chosen - as shown on plans/map _...� for reference) Design Flow !Operational Point (MGD) 1 GPM @TDH 1 Power Reliability Option 1 - permanent generator wlATS; 2 - portable generator w1MTS ' Force Main Size i Force Main Length i Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another facility treatment facility? • Yes // No If Yes, permit number of 2nd treatment (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes • No If No, please reference the pertinent minimum design criteria or regulation and Indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? M Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? Yes ❑ No ❑ N/A Stormwater? Yes ❑ No ❑ N/A Does this project include any high priority lines, [see 15A NCAC 02T ,0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details Owner/Permtttee's Certification: {Signature of Signing Official and Project Name) 1, Mike Garbark attest that this application for Ezzell Valley has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215. GA and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, Signing Official Signature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROX TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Date Professional Engineer's Certification: (Signature of Design Engineer and Project Name) dley W.Smith, attest that this application for Ezzell Valley has been viewed by me and is accurate, complete and consistent with the inforrnation iin the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria' for Gravity Sewers adopted Febniary 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor f which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation, iTY '2a. Bradley W. Smith Professional Engineer Name 2b. R.D. Davis Consulting Era ineer Engineering Firm 2c, 323 Indian Trail Road, North Mailing Address .. ............. . 2d. Indian Trail 2g. 704-821-7760 2h., 704-821-8014 Telephone Facsimile NC 2f, 28079 State Zip rddavis@carolina.rr.com E-mail ��- FTA 12/07 AVIS CONSULTING ENGINEERS, PLLC,, Ezzell Valley Project Narrative: The system consists of 9,027 if of 8" sanitary sewer and proposes to serve 103 lots. No additional lots will be directly served by the sanitary sewer petted under this application. No modifications to this permit are anticipated. Post Office Box 814 • 323 Indian Trail Road, North • Indian Trail, NC 28079-0814 • (704 821-7760 Fax (704) 82'i-8014 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Regarding; Sanitary Sewer to serve Ezzell Valley subdivision We are sending you: Copy of letter E Plans [ 1 Prints I Shop Drawings Z Other NC DENR MRO DW , Surface Water Protect on Date No. Description 6/12/08 6/121©8 5/28/08 6/2/08 6/17/08 5/28/08 Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application 5 Check for $480.00 (Application Fee) Flow Tracking Form CMUD Flow Tracking Form Stream Classification Form These are transmitted as checked below: For approval E For your use Remarks: Signed: Received by: Date: 7/15. 08 As requested fl For review and comments Date: 1 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications. (FTSE ---10/07) Project Applicant Name: linion County Project Name for which flow is being requested: Ezzell Valley More than one. FI5E-10/0 7 may be required for a single project, if the owner ofthe 4111TP is not responsible for all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWII' Facility Name: McAlpine Creek b. WWTP Facility Permit #: NCOO2497O Alt flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 0.01957 IL Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name None Approx. Capacity, MGD Approx, Current Avg. (Firm/Design) Daily Flow, MGD 111. Certification Statement: L. Christie L. Putnam , certifY that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policttd procedures using the best available data, This certification applies to those items listed above and II for whftich.,1-4 the responsible party. Signature of this form indicates acceptance of rater / 1 ckiLiSlgnWure Date State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE--1O/O7) Project Applicant Name: union County Public "e rks Project Name for which flow is being requested: Eze11 e- MoreMore than one FTSE-1O O7 may be required./ pump stations along the route of the proposed owner of the {YJV7P is not re,pp©n ibie fim all 1. Complete this section only if you are the owner o wastewater treatment plant. a. WWTP Facility Name: McAlpineµ Creek N rva.ra Greek, Sugar Creek WWTP b. WWTP Facility Permit: NC00 4t97a, NC0024945. NC'0024-937„ All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary e. WWTP facility's actual avg, flow f. 'Total. flow for this specific request g. Total actual and obligated flows to the fat: h„ Percent of permitted flow used the WWTP 99.0 .73 66.8 0,01957 0.59 81. 4'% Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. t pump stations located between the project con.rtection point and the WWTP Pump Station Name ix Mile Creek Approx. Capacity, MGD Approx. Current Avg. (Firrm/Design) Daily Flow, 'MGD 6.96 2,57 cation Statement: iN a at''r rl that, to the 'best: trot my knowledge, the addition of the volute e of v astevvater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that t:he flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station ern route to the receiving treatment plant under nonaial circurmstances. This analysis has been performed in accordance with local established policies and procedures using the best available data, This certification applies to those items listed above in Sections 1 and 1.1 for Which 1 am the responsible party. Signature of this form indicates acceptance of this .stewater flow,. uture Date 0 (CM CHARLOTTE. CHARLOTTE-MECKLENBURG UTILITIES June 24, 2008 Mr. Mike Garbark Union County Public Works 400 North Church Street Monroe, NC 28112-4804 SUBJECT: SEWER FLOW ACCEPTANCE EZELL VALLEY UNION COUNTY TAX PARCEL# 06-225-012B, 007B, 007C C-MU TRACKING #600-08-594 In response to your request, a flow acceptance study of the subject site has been completed and the following has been determined: Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 19,570 gallons per day (103 single-family lots x 190 gpd/lot) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. Please see attached basin map. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, you may contact me at (704) 391-5129. Sincerely, Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www.cmutilities.com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 r )-43 N0°oaae°o Charlotte -Mecklenburg Utilites WWTP Service Areas with Basins Un County Site 0-M U# 600-08-594 allard Creek WWTP FORM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name: Project Name Union County Public Works Ezzell Valley Professional Engineer Name Engineering 'Firm Name Bradley W. Smith R.D. Davis Consulting Engineers, PLLC Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification 1 Marvin Branch Union Catawba 11-138-3-4 C If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. ! certify that as a Registered Professional Engineer in the State of North Carolina that ! have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page 1 of 1 i. , Central Files: APS SWP 07/28/08 Permit Number WQ0033241 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 19570 Facilitv _Facility Name Major/Minor Region Ezzell Valley Minor Mooresville Location Address Owner County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Owner Affiliation Matthew Delk, Director Interim Public Works of Dates/Events °rig Issue App Received Draft Initiated 07/28/08 07/17/08 Scheduled Issuance Public Notice Issue Effective Expiration 07/28/08 07/28/08 Regulated Activities Requested/Received Events Subdivision Wastewater collection Outfali NULL Additional Information requested Additional Information received Waterbody Name Stream Index Number Current Class Subbasin