Loading...
HomeMy WebLinkAboutWQ0032990_Regional Office Historical File Pre 2018o�Ci W ATFgQG May 21, 2008 Ms. Christie Putnam, Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Dear Ms. Putnam, Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Subject: Permit No. WQ0032990 Lake Park Sewer Extension Union County Public Works Union County, North Carolina In accordance with your application received on April 30, 2008, we are forwarding herewith Permit No. WQ0032990, dated May 21, 2008, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycledll0% Post Consumer Paper No ` Carolina atllnnhfjt IF Ms. Putnam Page 2 May 21, 2008 In accordance with the provisions of Article 21 of Chapter 143, Genera! Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 333 linear feet of 8-inch gravity sewer and the discharge of 3,000 gallons per day of collected domestic wastewater into the Union County existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's 12 Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works. Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00054. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, 1-274 0 14------- for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files John Patrick, Eagle Engineering, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards.in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. r Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 21 st day of May, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032990 ' Fast Track Engineering Certification Permit No. WQ0032990 May 21, 2008 Owner/WWTP/WQCS Christie Putnam Union County Public Works 400 North Church Street Monroe, NC 28112 PE Jon Patrick Eagle Engineering, inc. 2013 Van Buren Ave. Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Lake Park Sewer, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1.5A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Plr USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: a, Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) Application Number: (to be competed by DWQ) © 1b. Christie L. Putnam, P.E., Director of Union CountyPublic Works Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) • 1 c. The legal entity who will own this system is: Individual ❑ Federal ❑ Municipality State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): ce O ld. 500 N. Main Street, Suite 500 ILL Z z Mailing Address if, North Carolina State 1 h. (704) 296-4210 Telephone ,(704) 296-4232 Facsimile 1e. Monroe City 1g. 28112 Zip Code 1j. cputnam co,union.nc,us E-mai 2. Project (Facility) lnfortion: t7b 2a. Lake Park Sewer Extension )o Serve Tax Parcel ©7a66©6C 2, Union Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: 3a. MikeGarbark, P.E.,.Assistant Director Union County Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (704) 2.96-4239 Phone Number 3c. mikegarbark af7co.union.nc.us E-mail Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Public (skip to item B(3)) 2a. If private, applicant will be: Private (go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.estore, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Union Cou Owner of Wastewater Treatment Facility 0 4a. Crooked Creek ce a Z Name of WWTF F) Treating ❑ Public Utility (Instruction C) 0 Homeowner Assoc./Developer (Instruction D) ater From This Project 4b. NC6069841 F Permit No. 5a, Union County 5b. 12.E ® Gravity Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ❑ School O Restaurant ❑ Office WWQ0004178 Permit # of Dawns ea Retail (Stores, shopping centers) El Institution El Hospital 0 Church ❑ Nursing Home 1 Other (specify): Daycare nstruction E) 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify). 7, Volume of wastewater to be allocated or permitted for this particular project: 3,©00 gallons per day "Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) 1'fAl21i)7 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 200 employees/children @ 15 gpd = 3,000 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" New Gravity or Additional Force Main 333.46' Gravity ❑ 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) LLJ M Pump Station Location ID (self chosen - as shown on plans/map for reference) Z ZDesign(MGD)ow Operational Point 0 GPM @TDH U Z Power Reliability Option 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 0 QPump Station Location ID (self chosen - as shown on planslmap for reference) E Design Flow Operational Point Power Reliability Option cc (MGD)GPM @TDH 1 - permanent generator w1ATS; Force Main Size Force Main Length 0 2 - portable generator wIMTS LL Z H E liY Pump Station Location ID (self chosen - as shown on plans/map for reference) a Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w1ATS; Force Main Size Force Main Length Di GPM @TDH 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12107 ve the following permits/ ertifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings General Permit or 401Certification? Sedimentation and Erosion Control Plan? Stormwater? El Yes LNo El Yes E] No Z Yes El No Z N/A N/A El N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: Z and provide details Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Christie L. Putnam., attest that this application for Lake Park Sewer Extension to Serve Tax Parcel 07066006C has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215 6B, any person who knowingly makes any false statement, representation, or Certi cation in any application s/ te guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 civil perialties;Up to $25, 0 per violation. Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY ci) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 0 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Jon R. Patrick, P.F. , attest That this application for Lake Park Sewer Extension to Serve Tax Parcel 0706606C has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria, for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a. Jon R. Patrick Professional Engineer Name 2b. IeEn ineering, Inc, Engineering Firm 2c, 2013 Van Buren Ave. Mailing Address 2d, Indian Trail 2e. NC City State 2g. 17041882-4222 2h. (704) 882-4232 2i. jpatrick Telephone Facsimile E-mail 2f. 28079 Zip eonline.net I L e•: F. I SEALi 027824 . itAIV*6% Qintitiottis NC PE Seal, Signature & Date FTA1 2/07 ht T, taptech, Inc State of North Carolina. Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Pro Applicatt Name: itfnn 7c►alrty Project Name for hich flow is bbeing requested: Lake Park. Sewer l .tension. to serve Tank Parcel07 More than one FTSE 10/0'7 may he required f rr a single project the ray rt ro he Tf is riot responsible fc r all pump stations along the route of the proposed wastewater f ow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Narne: b. WWTP Facility Permit : NC0069841. Crooked Cree All flaws are in MGD c. WWTP facility's permitted flow i 900,000. d. Estimated obligated flow :not yet tributary` to the "WWTP 69.167 e. WWTP facility's actual avg. flow 1,290,883 f Total flow for this specific request 390i0 g. Total actual and obligated flows to the facility 1,363,050 h. Percent of permitted Mow used 71. 74 Il. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Narne Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD None ification Statement; stie L. Putnam , , certify that tea the best of any know°lr*dge, the addition of the vcitain . of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated. to cause any capacity related sanitary^' sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established potici s jtnd procedures using the best available data. This certification applies to those items listed above in i ns i and 1I for which 1 am e responsible party. Signature of this form. indicates acceptance of ater flow. Fng fia Signature Date Central Files: APS SWP 05/21/08 Permit Number WQ0032990 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 3000 Facility ..Facility Name MajorlMinor Region Lake Park Sewer Extension to serve Tax Parcel Minor Mooresville 07066006C Location Address County Union Facility Contact Affiliation Owner Owner Name Owner Type Union County Public Works Government - County Owner Affiliation Christie Putnam, Director Public Works of 500 N Main St Ste 500 Monroe NC 281124730 Dates/Events Orig Issue App Received Draft Initiated 05/21/08 04/30/08 Scheduled Issuance Public Notice Issue Effective Expiration 05/21/08 05/21/08 Regulated Activities Re • uestedlReceiv d Events Child care facility Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name Chris Mathisen_ Lake Park Sewer Extension to Serve Tax Parcel 07066006C Professional Engineer Name Engineering Firm Name Jon R. Patrick, P.E. Eagle Engineering, Inc. Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification Mark 1 Crooked Creek Union Yadkin 13-17 20 C If unnamed, indicate "unnamed tributary to X. where X is the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that 1 have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page 1 of 1 Copyright (C) 1997, Maptech, Inc. UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N,C. 28115 Attention: TRANSMITTAL Date: 4/28/08 Regarding: Sanitary Sewer to serve Lake Park Sewer Extension for Tax Parcel 07066006C We are sending you: Copies Date 4/17/08 4/17/08 4/23/08 Copy of letter Other No, ; Description Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application 3199 Check for $480 00 (Application Fee Flow Tracking Form Stream Classification Form Plans Prints Shop Drawings These are transmitted as checked below: NC DENR M O )WQ Surface Wo For approval D For your use E As requested For review and comments Remarks: Signed: Received by: Date: $ClC Ct Michael F. Easley, Governor O1 WATfi9 0� 00 William G. Ross Jr., Secretary c� ._ r North Carolina Department of Environment and Natural Resources me p r ° `� -� Coieen Sullins, Director Division of Water Quality October 3, 2008 Union County Public Works 500 N. Main Street . Suite 500 Monroe, North Carolina 28112 SUBJECT: Lake Park Sewer Permit No. WQ0032990 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on Septembee,25,.; 2008.--A-full-review of the certification materials may or may not be conducted:-ft is -assumed that--- receipt:of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://h2o.enr.state.nc.us/ndpu/ndpUapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if . necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. •� . Robert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Jon Patrick, Eagle Engineering Surface Water Protection Section Central Files (certification page only) North Carolina !aturattq Pretreatment, Emergency Response and Collection Systems Unit Internet httpJlh2o.enr.nc.state.uslndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper Fast Track Engineering Certification Permit No. WQ0032990 May 21, 2008 ©wneriWWTPMWQCS PE Christie Putnam Jon Patrick Union County Public Works Eagle Engineering, Inc. 400 North Church Street 2013 Van Buren Ave. Monroe, NC 28112 Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial 'Final (^ TAZ. �, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, El weekly, 0 full time) the construction of Lake Park Sewer, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track. Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, Date No. Description 7/09/08Record Drawings 7/10/08 Engineer's Certification for Sewer (Permit WQ0032990) UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Attention: Dee Browder Regarding: Engineer's Certification Lake Park Sewer Ettention TRANSMITTAL Date: 9/2308 We are sending you: $ Copy of letter Plans L Prints - Shop Drawings Other Copies These are transmitted as checked below: For approval Remarks: Signed: For your use As requested For review and comments Received by: Date: on