Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0030282_Regional Office Historical File Pre 2018
o4 WA1 —O 1 May 23, 2006 Ms. Christie Putnam, Interim Director Union County Public Works 400 North Church Street Monroe, North Carolina 28112 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Subject: Permit No. WQ0030282 Old Hickory Industrial Park, Phase -17 Union County Public Works Wastewater Collection System Extension Union County, North Carolina Dear Ms Putnam: In accordance with your application received on May 18, 2006, we are forwarding herewith Permit No. WQ0030282, dated May 23, 2006, to Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville; NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycledll0% Post Consumer Paper No `Carolina �117atura!lj r. Christy Putnam Page 2 May 23, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicab4e Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 540 linear feet of 8-inch gravity sewer as part of the Old Hickory Industrial Park, Phase'aoject; and the discharge of 1,440 gallons per day of collected domestic wastewater into Union County's existing sewerage system, pursuant to the application received May 18, 2006, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County - Crooked Creek WWTP (NPDES No. NC0069841) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0069841) Kevin Vogel, LandDesign, Inc. Surface Water Protection Central Files Marie Doklovic, PERCS pr NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to. prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at feast three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in 'accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are. provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 23rd day of May, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030282 3 Fast Track Engineering Certification • Permit No. WQ0030282 May 23, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Old Hickory Industrial Park, Phase 7, Union County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1 Application Number: •/v�y��.7 (to be completed by DM) Y 1 l-' 1. Owner: la. Union County Public Works Department Full Legal Name (company, municipality, HOA, utility, etc.) Z 0 1b. Christie L. Putnam, P.E. Interim Director Union County Department of Public Works F„ Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) mplc. C The legal entity who will own this system is: ❑ individual ❑ Federal ❑ Municipality El State/County ❑ Private Partnership 0 Corporation • Other (specify): 0 1 d. 400 North Church street 11 e. Monroe LL Mailing Address I City Z 1 f. NC ilg. 28112-4804 Z . State Zip Code 0 1h. 704 296-4210 11 i. 704 296-4232 Ili. • Q Telephone Facsimile.' E-mail V 2. Project (Facility) Information: . J 2a. Old Hickory Industrial Park, Phase 7 • 2b. Union County O. CI. Brief Project Name (permit will refer to this name) 1 County Where Project is Located Q 3. Contact Person: Q3a. Charles P. O'Cain, P:E. Deputy Director Union County Department of Public Works Name and•Aft liation of Someone Who Can Answer Questions About this Application • • • • 3b. 704 296-4214 . - 3c. O'cain©co.union.nc.us ' • Phone Number E-mail • 1. - Project'is 0 New • Modification (of an existing permit) If Modification, Permit NO.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. F. Owner is El Public (skip to Item B(3)) •❑ Private (go to Item 2(a)) Z 0 2a. i If 0 • • private, applicant will be: 2b. Retaining Ownership (i.e. store, church, single office, etc.) or' Leasing units (lots, townhomes, etc. - skip to Item B(3)) Selling units (lots, .townhomes, etc. - go to Item B(2b)) If ■ ❑ sold, facilities owned by a (must choose one) Public Utility (Instruction III) Homeowner Assoc./Developer (Instruction IV) . ]— 3. Union County Public Works Dept. Q Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project w14a. Crooked Creek WWTP 4b. NC0069841 0 I Name of WWTF WWTF Permit No. LL 5a. Union County 5b. 8" r Gravity 5c. WQ0020132 Z Owner of Downstream Sewer Receiving Sewer Size • Force Main Permit Number of Downstream Sewer (if known) I— 6. The origin of this wastewater is (check all that apply): 2 lY ■ Residential Subdivision ❑ Apartments/Condominiums • Car Wash • Institution % Domestic/Commercial illI Lt. 0 ■ ❑ Mobile Home Park School oV estaurant r s` b Office • Hospital III■ Church °o Industrial Nursing Home % Other (specify): ' 9 Other (specify): i e 7. Volume of wastewater to be allocated for this particular project: 1,440 gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. i ❑ Rehabilitation or replacement of existing sewer with no new flow expected ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 W Z_ l— .Z 0 Z 0 2 ce 0 u. z B. PERMIT 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 1SA NCAC 2H .0219(I)(3). (360 GPD) x (4 LOTS) = 1,440 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 • ENTER TOTAL LINE LENGTH IN MILES Length (feet) 54'0 • 0.102 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on plans for cross-reference) Gravity or Force Main (use the pull down menu) Gravity Power Reliability Option Design Flow , Operational Point ; (1- dual line feed; 2- permanent generator w/ATS; 3- (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No ® N/A Sedimentation and Erosion Control Plan? ❑ Yes 0 No ® NIA Stormwater? 0 Yes 0 No ® NIA 14. Does this project involve aerial lines or siphons? Check if yes: 0 These. lines will be. considered high priority and must be checked once every six months_ __ W _ - 115. Does this project have gravity sewer lines designed at minimum slopes? 0 Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines instated outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 HACK APPLICATION for GRAVITY SEWERS, PI P STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled,"DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: E' A. Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location iD on Map (self chosen - as shown on Name of map for cross-reference) Waterbody Waterbody Stream Waterbody County River Basin Index Classification Submit the 8.5" x 11"' COLOR topographic map as required in Instruction VI regardless of whether a classification Is provided! Applicant Certification: 1, Christie L. Putnam, attest that this application for OLD HICKORY INDUSTRIAL PARK, PHASE 7 has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application' are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note,' In accordance with North Carolina General Statutes 143- 215.6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any p. ' at a n shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 00t0 as well as civil up to $25, 000 per vielafkrn.) ning Official Signi� e Professional Engineers Certification: I attest that this application for OLD HICKORY INDUSTRIAL PARK, PHASE 7 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly make any false statement,. representation, or certification in any application shall be guilty of a Class 2 mttsdemeanwhich ma i elude a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. Kevin W. Vogel Professional Engineer Name 2b. LandDesign, Inc, Engineering Firm 2c. 223 North Graha Mailing Address 2d, Charlotte City 2g. 704 376-7777 Telephone 2h, 704 376-8235 Facsimile E-mail 2f. 28202 Zip landdesign,com Sigr FTA 02/03 - Rev. 3 04/05 Central Files: APS SWP 05/22/06 Permit Number WQ0030282 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 1440 Facility Facility Name Major/Minor Region Old Hickory Industrial Park, Phase 7 Minor Mooresville Location Address Owner County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation Christine Putnam, Director Interim 400 N Church St Monroe NC 281124804 Orig issue App Received 05/18/06 Draft Initiated Scheduled Issuance Public Notice Issue Effective Expiration Regulated Activities Requested/Received Events Condominium Wastewater collection Outfall NULL Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve Old Hickory Industrial Park, Phase 7 Date: 4/21/06 We are sending you: Ej Copy of letter Q Plans © Prints El Shop Drawings �I Other Copies Date No. Description 4/"7/66 417/06 10/18/0 Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application*,; Check for $400.00 (Application Fee) These are transmitted as checked below: For approval P For your use Q As requested 0 For review and comments Remarks: Signed: Received by: Date: 11:Q QG William G. Ross Jr., Secretary r North Carolina Department of Environment and Natural Resources --I CI ,c Michael F. Easley, Governor Alan W. Klimek, P.E., Director Division of Water Quality October 5, 2006 Union County Public Works 400 North Church Street Monroe, North Carolina 28112-4804 SUBJECT: Old Hickory Industrial Park Phase 7 Permit No. WQ0030282 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on October 2, 2006. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has.you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from httQ://h2o.enr.state.nc.us/ndpu/ndpuabos.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, �-� 1-TU b. Rex Gleason, P.E. Surface Water Protection Regional Supervisor Enclosure Cc: Kevin W. Vogel Surface Water Protection Section Central Files (certification page only) Please forward copy to Engineer One NorthCarolina Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet httpifi2o.enr.nc.state.uslndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper st Track En • ineerin • Certification Permit No. WQ0030282 May 23, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial $1 Final I, 1t..1 4. COLt el.. , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([bperiodically, ❑ weekly, ❑ full time) the construction of the Old Hickory Industrial Park, Phase 7, Union County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, sign tore, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe„ NC 28112-4804 704/296-4210 Fax 704/296-4232 To: Mooresville Regional Office �. Water Quality 610 East Center Ave. Suite 301 Mooresville NC 28115 Attention: Dee Browder TTAL Date: 9/28/06 Regarding: Record Drawings and Engineer"s Certification for Sewer to serve Old Hickory Industrial Park Phase 7 (Final Certification) We are sending you: D Copy of letter Plans LJ Prints ❑ Shop Drawings Other Description Record Drawings Engineers Certification for Sewer (WQ0030282) These are transmitted as checked below: D For approval For your use 0 As requested El For review and comments Remarks: Received by: Date: Dater 01/07/06 Scale I " 1000' Project iCX)5276 Sheet. n; OLD HICKORY INDUSTRIAL PARK 8" SANITARY SEWER EXTENSION USGS TOPO MAP MERRIFIELD PARTNERS; CHARLEY' I E, NC MATTHEWS QUADRANGLE 3580-A6-TF-024 LandDesivct 333 tq Strew kas. NC ffi2b1 7043330 33.43 Michael F. Easley, Governor 1rwiSiam G, Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. K➢k, P.E„ Director ision of Water Quaff` October 3, 2006 Christie Putnam, Di ector tt° tterirn,, Union Countyfubfic Works Department 400 Nlh Church Street y Aroe, NC 28112 SUBJECT: Old HlckoIndustrial Park Permit No. WQ0030282 Wastewater Collection System Extension Final Engineering Certification Acknowledgement Dear Permittee: Per 15A NCAC 2H .0220, the Division received a final engineering certification for the subject project on 9/29/2006. Enclosed is a copy of the certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Note that the Division does not acknowledge partial certifications by letter. It is the Permittee's responsibility to track all submissions and receipt of partial certifications to the Division. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawir life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. s for the Lastly, you are receiving this letter because the Division has you listed as the responsible party. if this permitted system is no longer owned by you or your company, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://n2o,enestate.nc.us/percs from the Collection Systems Applications page. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact me at the letterhead address or via E-mail at tcm_ascenzo@ncmail.net, Thomas Ascenzo Environmental Technician Enclosure Cc: Kevin Vogel, PE, Land Design Inc (no enc 223 North GrahamStreet , Charlotte, HOC 2322 Surface Water Protection Section Central Des (certification page only) TOne Pretreatment, Emergency Response and Collection Systems Unit Internet httptTh2n.enr.nc,state.us/ndpu NorthCcar©llna 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal opportunity AcOpportunity Action Em«gayer Natural/Et Telephone (919) 733-5063 Fax (919) 733-0059 50%, recycled/1 O% post -consumer paper Fast Track Engineering Certification Permit No. WQ0030282 May 23, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension - - • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION . ❑ Partial Final I, kra• \I,Ot..L.. , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (I .periodically, ❑ weekly, ❑ full time) the construction of the Old Hickory Industrial Park, Phase 7, Union County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, sign •ture, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. LandDesign. urban design planning civil engineering landscape architecture - September 25, 2006 Mr. Kim Colson Supervisor, Fast Track Permitting Review System NC Division of Water Quality Water Quality Operations 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Wastewater Collection System Extension Union County Permit No. WQ0030282 Old Hickory Industrial Park Union County LandDesign PN #1005276 Dear Mr. Colson: DENR - WATER RUALfTY POINT SOURCE BRANCH Please find attached our final certification for the following 2 projects; WQ0030282 and WQ0020132. Please do not hesitate to call me should you have any questions or comments. est re in . Vogel, P.E. artner LandDesign 1 Charlotte 704.333.0325 KWVIrc Enclosures Cc: Charles 0' Cain, Union Co. Public Works Director Ken Chapman, Merrifield Partners 223 North Graham Street Charlotte, NC 28202 L-T1005276130csicwriFicRT1ONs 0.25.08.DOCARTC V:704.333,0325 F:704.332.3246 www.LandDesign.com Washington DC Charlotte NC Pinehurst NC Asheville NC Tampa FL Nashville TN Beijing PRC LandDesign, urban design planning civil engineering landscape architecture WATER AND SEWER TESTING CHECKLIST Project Name: Old Hickory Industrial Park Ph. 7 Project Number: 1005276 Date: 9 08 06 Tested By: J and T Utilities Weather: Warm and Sunny Observed By: Scott Tarlton Union County SEWER TESTING LOCATION/ROAD NAME:STINSON-HARDIS ROAD CC: Ken Chapman Merrifield Partners Kevin Vogel LandDesign Location of Line Size of Line:8 -inch MH TO MH MH TO MH MH TO MH MH TO MH MH TO MH EX34 1 2 Low Pressure Air Test Length of Time Pressure held per line: 4M1N.4PD. 4M1N.4PD. N/A N/A N/A Mandrel Pull Test Passed: Yes/No Yes Yes IN ).]e N 1 '\ 1iN Location of Line Size of Line: -inch MH TO MH MH TO MH MH TO MH MH TO MH MH TO MH Low Pressure Air Test Length of Time Pressure held per line: N/A N/A NIA N/A N/A Mandrel Pull Test Passed: YeslNo �.l N 141+X N1 NI -IN N N\ Location of Line Size of Line: MH TO MH MH TO MH MH TO MH MH TO MH MH TO MH Low Pressure Air Test Length of Time Pressure held per fine: NIA N/A N/A N/A N/A Mandrel Pull Test Passed: Yes/No 07'*C• il 1-t\ '1\0-Pt's tl h\ NW WATER PRESSURE TESTLOCATIONIROAD NAME: No note sewer only Size of Line Did pressure hold for at 200psi for 2 hours: Yes/No? 1-inch 1-inch 1-inch 1-inch 1-inch No No No No No FINAL WALK THROUGH: ® YES ❑ NO Comments: All items have been completed. Signed: PO Box 36959 Charlotte, NC 28236-6959 223 North Graham Street Charlotte, NC 28202 V: 704.333.0325 F:704.376.8235 FILE PATH: C°,Documents and Setlmostpcubison'ARy DorumentsMater and Seiner Testing Cneckiisi Old H[cknry Industrial park ph.1 lasing rp. k0052769 08 05.dcc