Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0030139_Regional Office Historical File Pre 2018 (3)
o��wA r�9Q� 05 r April 18, 2006 Ms. Christie Putnam, Interim Director Union County Public Works 400 North Church Street Monroe, North Carolina 28112 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Subject: Permit No. WQ0030139 Cureton Phase 2B Union County Public Works Wastewater Collection System Extension Union County, North Carolina Dear Ms Putnam: In accordance with your application received on March 24, 2006, we are forwarding herewith Permit No. WQ0030139, dated April 18, 2006, to Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains • adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper -ta?( oy` NCarolina 77atura!!rf rhstie Putnam 2 8, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 5,705 linear feet of 8- inch gravity sewer as part of the Cureton Phase 2B project, and the discharge of 0 gallons per day of collected domestic wastewater into Union County's existing sewerage system, pursuant to the application received March 24, 2006, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this, matter, please contact Dee Browder at (704) 663-1699. Sincerely, /� ,* for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0085359) Frank Craig, Titan Engineering Group Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. •The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be' provided as required by North Carolina General Statute §143-215.1C. I This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as. applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this p'ermit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 I Voice mail messages or faxed information -is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 1I of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 18th day of April, 2006.. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030139 3 rFast Track Engineering Certification Permit No. WQ0030139 April 18, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete rior allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Cureton Phase 2B, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. e Creek Name o a. Union County Public Works b. 1" Owner of Downstream Sewer '" eceiving Sewer Size The origin of this wastewater is (check all that apply): CATION for GRAVITY SEWERS, PUMP STATIOSD FORCE AIMS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) PE, Interim Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) Application Number: (to be completedby DWQ) e legal entity who will own this system is: Individual© Federal 0 Municipality i tetelCounty 0 P 400 North Church Stre Mailing Address City North C rolin 1g. 28112. h. 7 28 -4210 Telephone oject (Facility) Inanition: Cureton, Phase 28 Brief Project Name (permi Contact Person:_:.u_.._u....,,,., ed signing officials!) e Partnership_0 Corporation D Other (s Monroe Zip Code chrispco.union.nc.us E-mail b. Union County Charles P. O'Caiin, PE, Deputy Director of Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application -296r4214 3c. ©'Cain@co.union.nc Phone Number E-mail Project is New Q Modification (of an existing permit) If Modification, Permit No.: For modifications, difications, attach a separate sheet clearly explaining the reason Ior the modification (i.e. adding another phase, changing line size/length, etc,). Only include the modified information in this permit application - do not s _ and B(10-11) that has already been included in the original permit duplicate project 2 ject information in B(7) .�_ ��. �.� .��.. . Owner is Public (skip to Item 8(3)) 0 Private (go to Item 2(a)) private, applicant will be: 2b.If sold, facilities owned by a (must choose one) ppe) Retaining Ownership (i.e. store,church, single office, etc.) o Q Leasing units (lots, townhomes, etc. - skip to Item 8(3)) © Selling units (lots, townhomes, etc. - go to Item B(2b)) Uni©nCounty Public Works 0 Public Utility (Instruction IIi) Q Homeowner Assoc./Developer (Instruction IV) ewater Treatment Facility (WW i F) Treating Wastewater From This Project __— NC0085359 Residential Subdivision 0 Car Wash Q Apartments/Condominiums 0 Institution CI Mobile Home Park 0 Hospital 0 School 0 Church El Restaurant 0 Nursing Home Office El Other (specify): Volume of wastewater to be allocated for this particular proj *Do not include previously permitted allocations If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected WWTF Permit No W0(l2 9 19 Permit Num gallons per day nstream Sewe % Domestic/Commercial % Industrial % Other (specify): PAGE 4 ICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS . Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). For Construction Only. 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 ENTER TOTAL LINE LENGTH IN MILES Length (feet) Gravity or Force Main (use the pull down menu) 5,705 Gravity 1.08 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on plans for cross-reference) . I Power Reliability Option Design Flow Operational Point ! (1- dual line feed; 2- permanent generatorwlATS; 3- (MGD) GPM @ TDH ! portable generator wltelemetry; 4-wet well storage) 1 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations/and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 asppplicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ® No ❑ N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No ❑ N/A 14. Does this project involve aerial lines or siphons? Check if yes: ❑ .0Seilae.S.!+.'1.11iZelanaldeLerthi011.0000t21_OntiMUStite_CLEV d.QOSAe_veD SixiQt !& 5. Does this project have gravity sewer lines designed at minimum slopes? 0 Be aware that the Division will not accept Installed lines more than 1O% flatter than the minimum slope. Lines Installed outside this tolerance should be corrected prior to submitting the final engineering certification.. TCATION for GRAVITY SEERS, PUMP STATIONS, AND FORCE E'M .AINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 021t i (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality Z- regional office (see instructions for addresses) OR indicate the following: © A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on for cross-reference) Cureton, Phase 2B Name of Waterbody ittle Twelve Mile County Union Waterbody Stream Waterbody River Basin Index Classification Catawba 11-138-2 3 C Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification 1, Christie L. Putnum, attest that this application for Cureten, Phase 28 has been reviewed by me and is acccuiate and complete to the best of my knowledge. i understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments am not included, this application package is subject to being returned as incomplete. Note. In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shalt be guilty of 1 2 misdemeanor which may include a fine not to exceed $10 000 as well as civil penalties up to 325,000 per g Offi Professional Engineer's Certification: I :attest that this application for Cureton, Phase 28 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable ►egulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, 2a, Franklin S. Craig Professional Engineer Name 2b. Titan En ineerin Grou Engineering Firm 2c, 201 W.: Second Avenue Mailing Address 2d. Gastonia City 2g. 704-865-8012 2 h. 704-865-6861 Telephone Facsimile 2e. NC 2f. 28052 State Zip 2i. cdgfrank@carolina.rr.com E-mail Seal. Si ure & Date TOPOI rnap printed on 03/14/06 tom "Furth Carollna.tpo" and '"Untitted. tpg" 80°47.000' W 8f3°46.000 W GICarolina March 14, 2006 Charles O'Cain Deputy Director Union County Public Works 400 N. Church Street Monroe, NC 28112 RE: Cureton Phase 2B — Cunnane Section Charlie, Please allow this letter to serve as our official acknowledgement of the requested zero flow sanitary sewer permit for Cureton Phase 2B. We fully understand that the aforementioned permit does not guarantee any flow through this system. The issuance of a zero flow permit, by NCIDENR, allows only the construction of the permitted sewer infrastructure onsite by GS Carolina. We appreciate your consideration of this request. Please do not hesitate to call should you have any questions or need additional information. Sincerely, Sean T. Calloway Charlotte Development Manager cc: Christie Putnam, UCPW Tom Scott, GSC Frank Craig, TEG Pinakin Desai, TEG 17228 Lancaster Highway / Suite 201 / Charlotte, NC 28277 Phone (704) 752-5755 Fax: (704) 752.5767 UNION COUNTY PUBIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N,C, 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve Cureton, Phase 2B Subdivision We are sending you: Date 3/14/06 0] Copy of Iette i Other cription Original Non -Discharge Permit Application Plans Date: 32. Prints 0 Shop Drawings Copy of Non -Discharge Permit Application 2659 I Check for $400 00 (Application Fee Flow Letter from Developer These are transmitted as checked be For approval D For your use Li As requested 1 1 For review and Remarks: Signed: Received by: Date: Permit Number WQ0030139 Central Files: APS SVVP 04/18/06 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 0 Eac_ility Facility Name Cureton Phase 2B Location Address Owner MajorlMinor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates(Ev_ents _ _ _ Owner Type Government - County Owner Affiliation Christine Putnam, Director Interim 400 N Church St Monroe NC 28111 Orlg Issue App Received Draft Initiated 03/24/06 Scheduled Issuance Public Notice Issue Effective Expiration Regulated Activities Requested/Received Events Subdivision Wastewater collection Outfall NULL Additional information requested . Additional information received Waterbody Name Stream Index Number Current Class Subbasln