Loading...
HomeMy WebLinkAboutWQ0030048_Regional Office Historical File Pre 2018oFwA7 QG 7 t` Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H, Sullins, Director Division of Water Quality November 6, 2007 Ms. Christie Putnam, P.E., Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0030048 Sheridan Subdivision -Phase 2 Wastewater Collection System Permit Union County Public Works Union County, North Carolina Dear Ms. Putnam, ' In accordance with your complete application received on November 5, 2007, we are forwarding herewith Permit No. WQ0030048, dated November 6, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition -3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC, 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncmwalerquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycledll0% Post Consumer Paper No `Carolina �turally PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 43 single - family units: 285 GPD/unit x 43 Lots = 12,255 GPD (Note: 86 total lots in Phase 2, 43 lots previously approved March 30, 2006) Original Permit: = 15,480 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu)- - (No Additional Line) 1 - -_ _1 LLI H 0 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Z 0 H et 0 LL. Z 2 le W 0. m ENTER TOTAL LINE LENGTH IN MILES Location ID — (self chosen - as shown on • Design Flow ] Operational Point plans for cross-reference) , (MGD) GPM @ TDH N/A € 4- 12. Does the sewer system comply with the Mil nimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes El No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Power Reliability Option (1- dual line feed; 2- permanent generatorw/ATS; 3- , portable generator wltelemetry; 4-wet well storage) 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ® Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No ❑ N/A Does this project involve aerial lines or siphons? Check if yes: ❑ TheseJines wilLbe considered-hiah prionity and.must be,checked once every six.months_ 15. Does this project have gravity sewer lines designed at minimum slopes? ® - Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines Installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 f/} z 0 APPA' ON for GRAVITY SE 4 ERS, f'1i Lf' STATIONS, AND FORCE MAINS PAGE 5 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) QR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Waterbody; AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification SITE Price Mill Creek Trib, Union Catawba 11-138-2-2 C Submit the 8.5" x 11°' COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: Christie L. Putnam, P.E, Director of Public Works, attest that this application for Sheridan Subdivision Phase 2 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina Gen :; Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, art tion in any application shall be y of a Class 2 misdemeanor which may include a fine not to exceed $10,000 ivil penalties up'$25,000 p violation. Signing Official Si it1ature Professional Engineer's Certification; t ` /c ' • C3 Date I attest that this application for Sheridan Subdivision Phrase 2 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. i further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215 6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25,000 per violation. Wayne M. Harris, P.E Professional Engineer Name 2b Harris Engineering Engineering Firm 2c 1325 Harding Place Mailing Address 2d, Charlotte 2e, NC 2f. 28204 _., City Stateis _m-..._ 2g. (704) 334-1325 2h(704) 334-1330 2i, wharris@harrws-engr.com Telephone Facsimile E-mail FTA 02/0 - Rev, 3 04105 v .3 2007 NC DENR MR0 DWQ-Svface Water Protectjoi Permit Number WQ0030048 Central Files: APS SWP 11/05/07 Permit Tracking Slip Program Category Status Project Type Non -discharge In review Major modification Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer B Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 27735 Facility Facility Name Sheridan Subdivsion - Phase 2 Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Owner Affiliation Christine Putnam, Director Interim 500 N Main St Ste 500 Monroe NC 281124730 Dates/Events Orig Issue App Received 03/30/06 11/05/07 Scheduled Draft Initiated Issuance Public Notice Issue 11/06/07 Effective Expiration 11 /06107 Regulated Activities Rea uestedlReceived Events Subdivision Additional Information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Sheridan, Phase 2 Subdivision We are sending you: Copy of letter Plans OP ns E Shop Drawings Other TRANSMITTAL Copies D ate 10/7/07 10/7/07 10/15/07 No. Description Original Non -Discharge Permit Application I Copy of Non -Discharge Permit Application 006597 Check for $480,00 (Application Fee) These are transmitted as checked below: For approval Remarks: Signed: Received by: Date: L For your use As requested Date: 10/19/07 N DENR RO Re: Sheridan Subdivision Phase 2 Subject: Re: Sheridan Subdivision Phase 2 From: MikeGarbark@co.union.nc.us Date: Mon, 29 Oct 2007 17:33:45 -0400 To: dee.browder@ncmail.net Only the flow changes on this. Original: 12,255 gpd Modified: 15,480 gpd (to add) Total: 27735 gpd Mike Garbark, PE Assistant Engineering Director ; Union County Public Works 500 N Main Street Monroe, NC 28112 Dee Browder <dee.browder@ncmail.net> wrote: To: MikeGarbark@co.union.nc.us From: Dee Browder <dee.browder@ncmail.net> Date: 10/29/2007 03:56PM Subject: Sheridan Subdivision Phase 2 WQ0030048 Need totals Thanks DEE ADdvD 1 of 2 11/5/2007 11:42 AM Re: Sheridan St division Phase u Subject: Re: Sheridan Subdivision Phase From: Dee Browder <dee,browder@ncnl Date: Mon, 05 Nov 2007 1:4 :47 -0500 Also confirm line lengths, pump stations ete. DEE Mike Carbarkc.uion.ne,us wrote: Only the flow changes on this. Original: 12,255 gpd Modified: 15,480 gpd (to add) Total: 27735 gpd Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 —Dee Browder .<dee.l rowder itlncin To: i keGarbark 'rk From: Dee Browder <dee, ..us Date: 1,0/29/2007 43:56PM Subject: Sheridan Subdivision, Phae.2 WQ003ii048 111,' 007111:43A. t Sheridan Subdivision Phase 2 Subject: Sheridan Subdivision Phase 2 From: Dee Browder <dee.browder@ncmail.net> Date: Mon, 29 Oct 2007 15:56:37 -0400 To: MikeGarbark@co.union.nc.us WQ0030048 Need totals Thanks DEE ADdv 1 of 1 10/29/2007 4:03 PM Re: Sheridan Subdivision Phase 2 Subject: Re: Sheridan Subdivision Phase 2 From: MikeGarbark@co.union.nc.us Date: Mon, 5 Nov 2007 13:05:02 -0500 To: dee.browder@ncmail.net Dee, 1 reversed the numbers on the last one...here are the updates. Sheridan Phase II Original WQ003004 (Issued 3/30/06) Flow: 15480 gpd Length: 4,678 LF of 8" SS Modification WQ003004 (submitted on 10/19/07) Flow: 12,250 gpd Length addes: 0 LF Totals for Sheridan Flow: 27,735 gpd Length: 4678 LF of 8" SS Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street ' Monroe, NC 28112 Dee Browder <dee.browder@ncmail.net> wrote: To: MikeGarbark@co.union.nc.us 1 of 3 11/5/2007 1:45 PM Re: Sheridan Subdivision Phas From: I)ee Browder <dee.hrowdert ne .ail.net> Date: 1.1 /11 72007 11:42AM Subject: Re: Sheridan Subdivision ,Phase 2 Also conlirnn line lengths, pump stations etc.. I)EE ''like Only the flow changes on this. Original: 12,255 gpd Modified: 15,480 gpd {to add) Total: 27735 gpd Mike C arbark, PE Assistant Engineering Director Union County Public t rrks 500 N Main Street Monroe, NC 28112 ..-1)ee Bro der To: MikeCarhark From: Dee Browder <dee,browder Date: 10/29/2007 03:56PM. Subject: Sheridan Subdivision Phase 2 WQ0030048 Need totals Thanks 2 of 3 11/5/2007 1:45 PM Re: Sheridan Subdivision Phase 2 DEE ADdv ❑ • ADdv ❑ 3 of 3 11/5/2007 1:45 PM Track e Owrfer/WNTP/WQCS Christie Putnam prmit No W00030048 Novmber 6, 2007 TEngineering Certification 7' Unioi County Public Works 400 North Church Street Mor roe, NC 28112 PE Wayne Harris Harris Engineering 1325 Harding Place Charlotte, NC 28204 te71 I wPi '3,t- 4A Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Pe mit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial jE Lil Final tvf., 4141I4A7 , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (RI' periodically, Li weekly, LI full time) the construction of Sheridan Subdivision -Phase 2, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: 01.1 t71 SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: Ms, Dee Browder Regarding: Engineer's Certification for Sheridan Phase 2 (Partial) We are sending you: L Copy of letter Other Copies Date 12/4/13 1/22/13 No, Description X Plans TRANSMITTAL Prints El Shop Drawings Record Drawings Engineers Certification for Sewer (Permit WQ0030048) These are transmitted as checked below: For approval Remarks: Signed: Received by: For your use P As requested LI For review and comments Date: