Loading...
HomeMy WebLinkAboutNC0088226_BIMS Report_20220121United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN Code I 2 IL NPDES yr/mo/day Inspection Type Inspector Fac I 3 I NC0088226 111 121 22/01/14 117 18110 191 S I 201 Type 21IIIIII IIIIIIIIIIIIIIIIII I IIIIII IIIIIIIII1I P6 Inspection 67I1.0 Work Days Facility Self -Monitoring I 70I3 Evaluation Rating I 711D B1 I 72 QA I N I 731 I I I Reserved 74 751 1 1 1 1 1 1 1 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) Wells Fargo Tryon St groundwater remediation 550 S Tryon St Charlotte NC 28202 Entry Time/Date 10:OOAM 22/01/14 Permit Effective Date 20/09/01 Exit Time/Date 11:30AM 22/01/14 Permit Expiration Date 25/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Christopher David Orrell/ORC/704-200-3436/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Rhonda F Ballard,550 S Tryon St 30th Floor Charlotte NC 28202//704-374-4761 / No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Compliance Schedules Effluent/Receiving Wate Laboratory Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Edward Watson DWR/MRO WQ/ - - / 1-D�ocuSigned by: C.<4.4R,,i .yam 1�21�2022 6A46EBFSF86F436... Signature of Managsement Q A Reviewer Agency/Office/Phone and Fax Numbers Date Docu ignedby: ritSitti4VH P rat 1. 21. 2 2 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 sI NPDES yr/mo/day NC0088226 111 121 22/01/14 I17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On January 14, 2022, MRO staff performed a Compliance Inspection for the treatment system located in the Wells Fargo building under permit NC0088226. During the site visit, it was mentioned that the name of the permittee is likely to be changing. MRO staff has attached a link for the permittee to be able to access the name change form. https://deq.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/collec tion-systems/name-ownership-change The name change information should also be submitted to the MRO to update ours records. Waste manifests for spent filter media are to be provided to the MRO via email. A review of the laboratory analytical data from May 2021 through December 2021, indicates that effluent is within the permissible limits. The facility is operating in compliance with the permit. Page# 2 Permit: NC0088226 Inspection Date: 01/14/2022 Owner - Facility: wells Fargo Tryon St groundwater remedl Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new MODE application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: A copy of the permit was provided by DWR staff during the site visit. There are no special conditions listed in this permit. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MODE Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The O&M records were reviewed for 1-2021 through 12-2021. The records appear to be in order and up to date. Compliance Schedules Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The facility is meeting the compliance sampling schedules as stipulated in the permit. Other Yes No NA NE Comment: The treatment systems employ redunant treatment, as the majority of the effluent water is utilized in the building HVAC system. Effluent discharge was viewed at the sampling point. Flow through the effluent meter is less than half of the permitted daily flow for this system. Meter calibration records are current Page# 3