HomeMy WebLinkAboutGW1-2022-01371_Well Construction - GW1_20220124 4
WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only:
1.Well Contractor Information:
NICHOLAS HAYES 14.WATER ZONES ;
Well Contractor Name FROM TO DESCRIPTION
ft. ft. f
A - 4121
NC Well Contractor Certification Number 15.OUTER CASING for multi-cased wills OR LINER if a licable
GEOLOGIC EXPLORATION FROM TO DIAMETER THICKNESS MATERIAL
ft. ft. in.
Company Name
16.INNER CASING OR TUBING @othermal closed-loop)
2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.UC,County,State,Variance,etc.) 0.0 ft- 64.0 ft• 1.0 i"' SCH 40 PVC
3.Well Use(check well use): R. ft. in.
17.SCREEN
Water Supply Well:
FROM TO DIAMETER. SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public 64.0 ft• 74.0 ft' 1.0 '"' .010 SCH 40 PVC
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ft. ft. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) T&GROUT
❑Irrl ation ❑Wells>100,000 GPD FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT
Non-Water Supply Well: 0.0 ft. 56.0 ft' PORTLANDaENTONITE SLURRY
MMonitoring ❑Recovery
Injection Well:
ft. ft.
❑Aquifer Recharge ❑Groundwater Remediation
19.SAND/GRAVEL PACK ifa licable
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage 62.0 ft. 74.0 ft 20-40 FINE SILICA SAND
❑Experimental Technology ❑Subsidence Control ft. ft.
❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG attach additional sheets if necessary)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM TO DESCRIPTION color,hardness,soil/mck type,grain sin,etc.
0.0 ft. 17.0 ft- BROWN SILTY SANDY CLAY
4.Date Well(s)Completed: 11/29/21 well ID# FGDLFPZ-13 17.0 ft- 32.0 ft. BROWN SILTY SAND
5a.Well Location: 32.0 ft' 38.0 ft' DARK BROWN SILTY SAND
BELEWS CREEK STEAM STATION 38.0 ft. 74.0 ft. PWR
Facility/Owner Name Facility ID#(ifapplicable) ft. ft'
3195 PINE HALL ROAD BELEWS CREEK 27009 D. ft.
Physical Address,City,and Zip ft. ft.
STOKES 21.REMARKS
County Parcel Identification No.(PIN) BENTONITE SEAL^- 56.0-62.0 FEET
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.Certification: 'd� /
360 27' 41.82" 80° 05' 47.02"N W 12/10/21
6.Is(are)the well(s): TPermanent or ❑Temporary Signature ofCeilified Well Contractor Date
By.signing this form,I hereby certify that the well(s)was(were)constructed in accordance with
7.Is this a repair to an existing well: ❑Yes or ONo 15A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction,Standards and that a copy
/(this is a repair,fill out known well construction information and explain the nature of 1he of This record has been provided to the well owner.
repair under P21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page;to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary.
drilled: 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 74.0 (ft.)
For muhip/e we//s list all depths ifdi ferenl(example-3 rt 200'and 2 a/00') Submit this GW-1 within 30 days of well completion per the following:
70.0 24a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: (ft.) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
lflraler level is above casing,use"4
11.Borehole diameter: 6.0 (in.) 24b. For Injection Wells: Copy to DR,Underground Injection Control (IUC)
Program, 1636 MSC,Raleigh,NC 2W7699-1636
12.Well construction method: AIR 24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY:
24d.For Water Wells producing river 100,000 GPD: Copy to DWR,CCPCUA
Permit Program,1611 MSC,Raleigh,NC 2 7699-161 1
13a.Yield(gpm) Method of test:
f
136.Disinfection type: Amount: �
I
Fonn GW-I North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6.2018