Loading...
HomeMy WebLinkAboutWQ0023284_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality Mr. Jon Dyer, Director of Public Works Union County ' 400 North Church Street Monroe, North Carolina 28112 November 14, 2003 Subject: Permit No. WQ0023284 Union County Retail Lease Shell Buildings Wastewater Collection System Extension Union County Dear Mr. Dyer. in accordance with your application received on November 14, 2003, we are forwarding herewith Permit No. WQ0023284, dated November 14, 2003, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover_ letter shall be considered a part of this permit and is therefore incorporated therein by reference: - r - Please pay particular attention to Permit Condition 3. which ; .requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A .NCAC 2H .0200; 2) the Division .of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. AAA Mooresville Regional Office Internet http:llh2o.enr.state.nc.us! 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 .i: v-.vr��v�rw unrr=aayfJ6o:�e ynP11�R+G�eFiVrtGv-16--ife6---cipp pricit `revision—riorittr `turnue' in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified; you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings,' and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7: A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9: .In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Pemiittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 14th day of November, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023284 Fast Track Engineering Certification Permit No. WQ0023284 November 14, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified an the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Retail Lease Shell Buildings, Union County project for the Permittee hereby state that, to the best of -my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this - Engineer's Certification shall be considered a violation of the permit and shall subject the Pemiittee to appropriate enforcement actions. 0 ,K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1, Owner, la union Sovntv Department of Public Works Full Legal Name (company, municipality, HOA, utility, etc,) PAGE 3 Application Number: (to be compietecl by DWO) VV224 ib. Jon C. Pyer, P.E.,Director, Union County_ Department of Public Works Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: LI Individual 0 Federal 0 Municipality EXI State/County Private Partnership D Corporation 0 Other (specify): ld. 400 North Church Street le Monroe Street Address City U. —Jr dr— If, North Carolina tg, 28112-4804 z 0 lh, 704-296-4210 Telephone Facsimile Q 2, Project (Facility) Information: 2a- Retail eaw SheU.BujJjJp 2b. • Brief Project Name (permit will refer to this name) County Where Project is Located < 3 Contact Person: State Zip Code 0 z -IL 704-296-4232 ij jondyer@co.union.nc.us E-mail 3a. Charlie O'Cain, P.E., Deputy 'Director Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 704-296-42411 4'1 / 3c. 0' cain@cownion.nc.us Phone Number Email 1 Project is 9 New 0 Modification (of an existing permit) If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le, adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2 Owner is Public (skip to Item B(3)) El Private (qo to item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Public Utility (Instruction 110 0 Leasing units (lots, townhomes, etc, - skip to Item B(3)) Homeowner Assoc./Developer (Instruction IV) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3, Union County Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a„ Twelve Mile Creek WWTF 4t1 NC0085359 Name of WWTF WWTF Permit No. : 5a. Union County 513, 8 inch 5c ; : - Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): 0 Residential Subdivision El Apartments/Condominiums 0 Mobile Home Park 0 school DI Restaurant Office 0 Car Wash El Institution [21 Hospital 0 Church 0 Nursing Home [74 Other (specify): Retail 7, Volume of wastewater to be permitted in this project: 8,761 gallons per day 100 ',/c, Domestic/Commercial % Industrial % Other (specify): 8. If the perrnitted flow is zero, indicate why. 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line n Flow has already heen allocated in Permit No O Rehabilitation or replacement of existing sewer with no new flow expected :ACK APPLICATION for RA 4rl[TY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGES 1. Use the Division's guidance dr cur ant entitled, "DETERMINING STREAM CI-ASSIFICATI©NS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets ast necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, Z 0 A Stream Classification is not needed because the design does not depend on wet well sto option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on power reliability iy Stream Waterbody „neap fb.r _ _County.....__. _ __.R r er Basin Index Cla�if c © '2b plcant's Certification: Name of x 11" COLOR topographic ardles of whether a ciasai p as required in Ins cation is provided! Jon C. Dyer, P.E. attest that this application for Retail Lease Shell Buildings has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application am not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be gui i of a Class 2 misdemeanor which may include a fine not to exceed $10,000 well as cMi penalties up to $25, * e io1ation. Professional Engin ' erti6c tion: I attest that this application for Retail Lease Shell. Bldgs. has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Atthough certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 1443-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Larry B. Smith, P.E. Professional Engineer Name Engineering Fim P.O. Box 784 Address 2d. Monroe City NC f. 28111 State Zip 2g.704-289-S168 2h.704-283-•4084 2i. lbsrnith@vnet.net Telephone Facsimile E-mail Seal, Signature Date Attachment FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 6 Retail Lease Shell Buildings Union County Public Works 3903 Providence Road South Waxhaw, North Carolina Part B.9 Wastewater Flow Calculations Assume upfit will be all retail 1 office and allow for restaurant seating as follows: 19,162 SF (total) - 5,326 SF (restaurant) = 13,836 SF 13,836 / 1,000 = 13.836 x 120 = 1,660 gallons per day For restaurant assume 50% non -seating area and 50% seating area: 5,326 / 2 = 2,663 SF 2,663 / 15 = 177.53 177.53 x 40 = 7,101 gallons per day Total = 1,660 + 7,101 = 8,761 gallons per day 5 7'30' 11/14/03 Permit Number WQ0023284 Permit Tracking Slip Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 8761 Facility Fast Track Status Protect Type In review ' New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Retail Lease Shell Buildings Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events . Owner Type Government - County Owner Affiliation Jon Dyer 400 North Church Street Monroe' NC 28112 Orig Issue App Received 11/14103 Regulated Activities Scheduled Draft Initiated Issuance Public Notice Issue Effective ' yi4./p3 Requested/Received Events Commercial or industrial, other Restaurant Wastewater collection Outfall NULL Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 919 North Main Street Mooresville, N.C. 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve Retail Lease Shell Buildings Waxhaw We are sending you: 21 Copy of letter [I Other No. Description Original Non Discharge Permit Application Copy of Non Discharge Permit Application heck for $400 00 (Application Fee) Plans El Prints [ These are trans as checked below: For approval 0 For your use [l As requested 0 Fo Remarks: Signed. Received by: Date: Date: 11/12/03 Shop Drawings 4 �L�;��TION