Loading...
HomeMy WebLinkAboutWQ0023129_Regional Office Historical File Pre 2018VATER Michael F. Easley, Governor OQG William G. Ross Jr., Secretary . r North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality September 30, 2003 Mr. Jon Dyer, Director of Public Works Union County 400 N. Church Street Monroe, North Carolina 28112 Subject: Permit No. W00023129 Union County Quintessa Subdivision Wastewater Collection System Extension Union County Dear Mr. Dyer: In accordance with your application received on September 30, 2003, we are forwarding herewith Permit No. WQ0023129, dated September 30, 2003, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. NCDENR Mooresville Regional Office Internet http:Ilh2o.enr.state.nc.us/ 919 N. Main Street. Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. Jon Dyer Page 2 September 30, 2003 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County for the construction and operation of approximately 13,338 linear feet of 8-inch gravity sewer; and approximately 524 linear feet of 12-inch gravity sewer to serve 89 three -bedroom residences as part of the Quintessa Subdivision project, and the discharge of 32,040 gallons per day of collected domestic wastewater into Union County's Twelve Mile Creek WWTP (NPDES No. NC0085359) existing sewerage system, pursuant to the application received September 30, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, /7 R.� f. for Alan W. Klimek, P.E. cc: Union County Health Department Mooresville Regional Office, Water Quality Section (WW TF Permit No. NC0085359) Denver Toler, Alliance Engineering & Surveying Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. Fr 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. Pr 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 30th day of September, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. KIi ek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023129 Fast Track Engineering Certification Permit No. WQ0023129 September 30, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Quintessa Subdivision, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. z 0 CATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD' Owner. 1a. Union Ccwun' Full Legal Name lb. Jon C. Dye Signing Offi any, municipality, HOA, u actor of Public Works Name and Title (Please review 't5A NCAC 2H .02t(b Application Number: (to be completed by DW0) 6Z(V2 I ed signil PAGE 1 lc. The legal entity who will own this system is: 0 individual 0 Federal 0 Municipality State&County 0 Private Partnership 0 Corporation 0 Other (specify): le, Monroe ld. 400 N. Church Street Street Address If. N.C. �r State 0 l h. (704) 296-4219 l i. (704) 296-4232 Telephone Facsimile 2. Project (Facility) information: a. 2a.. Quintessa I, Brief Project Name (permit wvill refer to this name 'Q 3. Contact Person: " 3a. Charles P. €'Cain, P.E. -- Deputy Director ©f Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application City lg. -28112 Zip Code 3b. , (704) 296-4210 Phone Number 1, Project is New 0 Modification (of an existing permit) if Modification, Permit No_: E-mail 2b. Union x . County Where Proj� is Lted 2. Owner is + Public (skip to item B(3)) 0 Private 2a. If private, applicant will be: 0 Retaining Ownership (i.e. store, church, single office, etc.) 0 Leasing units (lots, townhomes, etc. - skip to item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) Union County Owner of Wastewater'Tretm+ent F elve Mile Creek WWT'F me of WWTF 3c. o'cain@co.union cr Item 2(a)) If sold, facilities owned by a (must 0 Public Utility (Instruction iII) 0 Homeowner Assoc/Developer (Inson IV) 2b. Treatiewater From This Pi 4b. NC0485359 5a. Union County 5b. 24" Owner of Downstream Sewer Receiving Sewer aiz 6. The origin of this wastewater is (check all that apply): Residential Subdivision 0 Apartments/Condominiums Q Mobile Home Park 0 School 0 Restaurant. 0 Office 0 Car Wash 0 Institution 0 Hospital © Church 0 Nursing Home 0 Other (specify): WWTF Permit No. WQOO 19128 Permit Number of Downstr m Sewer 100 % Domestic/Commercial % Industrial % Other (specify): 7. Volume of wastewater to be permitted in this project: 32,040 gallons per day 8. If the permitted flow is zero, indicate why_ 0 interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NLAC: zH .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). 89 houses x 3 bedrooms/house x 120 gpd/bedroom = 32,040 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) ) Gravity or Force Main (pull down menu) 12 524 Gravity 8 13,338 Gravity 0 Force Main Li! Gravity Z Gravity ZGravity CO.? Gravity Z ENTER TOTAL LINE LENGTH IN MILESi 2.63 O — — Q11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) 2 C Q Location 1D (as shown on plans) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (dual line feed, permanent generator MATS, portable generator wlautodialer, wet well storage) LL Z 1— 2 • ce W EL m 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 16A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Weiland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? CI ® ® Yes Yes Yes ■ ❑ • No No No ■ ❑ • - N/A N/A N/A z 0 2 [CATION for GRAVITY SEW RS, PUMP STAI [ONS, AND FORCE MAINS PAGE 3 Use the Division's guidance document entitled, "DETERMINiNG STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, D A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location iD Name of Waterbody Stream Waterbody on Map Waterbody County River Basin index Classification Source to E. Fork Price Mill Creek Union Catawba 11-138-2-2 C 17-Miip r',raimk Submit the 8.5'° x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1 attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge, i understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In acco ance with North Carolina General Statutes 143-215.6A and 143-215.68,. any person who knowingly makes any false s tement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include ne not to exceed $10,000 as well as civil penalties up to $25,000 per iolation. ning Professional Eintir)eef Certification: I attest that this application for sanitary sewer extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a tine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Denver D. Toler Professional Engineer Name 2b, Alliance Engineering & Surveying__ Engineering Firm 2c. P.©. Box 1609 Address 2d. Monroe City 2e, NC 2f, 28111 State Zip 2g. , ) ( ,) 2'i, alliance@bog9spaving.com 7!©4 289-4712 Zh. 7t/4 2$3-G1977.�___. Telephone Facsimile E-mail Seal, Signature Date UTM GRIT) AND 1988- MAGNETIC NORTH DECLINATION AT CENTER OF SHEET 'AXHAW) 4853 ! NCN SCALE 1`24000 G 1000 2300 3000 4ik7C1 5 CONTOUR INTERVAL 10 FEET NATIONAL GEODETIC VERTICAL DATUM OF 1929 V! A rr Z'.4 5 I hl . 35G$o _A is` -mom - 2t4 1 4 P+40-ro t.Evt i q,96 TL 1S MAP COMPLIES WITH NAT4CNAL MAP ACCURACY STANDARDS FOR SALE BY U. S. GEOLOGICAL SURVEY DENVER, COLORADO 80225 OR RESTON, VIRGINIA 22092 A FOLDER DESCRIBING TOPOGRAPHIC MAPS AND SYMBOLS 15 AVAILABLE ON REQUEST 7000 SECT 1 I0L0d'1ETER 09130/03 Permit Number WQ0023129 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 32040 Facility Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Quintessa Subdivision Location Address Owner Major/Minor Minor Region Mooresville County Union Facility Contact Affiliation Owner Name Union County Dates/Events Owner Type Government - County Owner Affiliation Jon Dyer 400 North Church Street Monroe NC 28112 Scheduled Oriq Issue App Received Draft Initiated Issuance 09/30/03 Regulated Activities Public Notice Subdivision Wastewater collection Wastewater treatment and disposal Outfall NULL Issue `i/aqo3 Effective Requested/Received Events Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 7041296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 91' 9 North Main Street Mooresville, N.C. 28115 Attention:. Regarding: Sanitary Sewer to serve Quintessa Subdivision We are sending you: Copy of letter [ Plans L Prints LJ Shop Drawings VI Other TRANSMITTAL No. Description Original Non Discharge Permit Application Copy of Non Discharge Permit Application Check for $400.00 (Application Fee) These are transmitter as checked below: For approval Li For your use 1 As requested Remarks: Signed: Date: 9/26/03 For review anl'cot'nrrrents Received by: Date: UNION COUNTY PUBLIC WORKS 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: Mooresville Regional Office Water Quality 610 East Center Ave. Suite 301 Mooresville NC 28115 Attention: TRA SMITTAL Date: 11/19/04 Regarding: Record Drawings and Engineer's Certification for Quintessa Subdivision (Final Certification) We are sending you: [� Copy of letter Other No. Description Record Drawings Plans Prints E Shop Drawings Engineer's Certification for Sewer (W'Q0023129) These are transmitted as checked belo El For approval I For your use Remarks: Signed: Received by: L As requested For review and comments Date: Track E n iineeriq Certifucatiicttt Pe it No.'I September 30, Complete and s rbmit IL§ form to the permit issuing r +� One copy m the pro iect record drawings (plan & profile views of sewer iection system exte lsiert supporting c esign a Iculatiohs (selected pumps, system curve, operating point, available storage if portable generator(s' or storage greater than longest past three year outage reliability option selected) for any pump stations per pitted as part of this project +� Changes to the project should be dearly identified on the record drawings or in written spar form. Pe€rnit modtficatlor s ant, ruired joy any oranges resulting n non-cornehance with this permit, regu(at►.gins tar minimum gg sign criteria, This project she I not be considered required supper ing documentation that this certifH :elan be sent In a plate nor allowed to operate until this Engineers Certification and all received by the Division. Therefore, It le highly recommended at provttles proof of receipt by the Dhrlsion. ENGINEER'S C_ERTIFICATt9N 0 Partial Final I, ftitJE12L am, as a duly registered Professional Eng neer in the State of North Carolina. having been authorizec to iodic ally, 0 weekly, ] full tune) the construction of the Qu ntessa Subdivrisioon, � ly °` °flay the Perm iltee hereby state that, to the best of my abilities, due care and diligence was u: ed in the observati n of the construction such that the construction was observed to be built within substantiz 4 c+omp5ance of this permit; 15A NCAC 2H .0200. the Division of Water Quality's (Division) Gravity; Sewer It inirnum. Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the F est-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting. materials. North Carolina i jrofessional Engineer's seal, signatu SEND THIS FORNI S. St IR ED ATTACHMENTS TO A Mt3ORESVRIE REf�� OFI=ICE 919 H. MAIN STREET MO©RESVILE NC 28115