Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0043105_Application_20220114
January 13, 2022 North Carolina Department of Environmental Quality (NCDEQ) Division of Water Resources 610 East Center Avenue Mooresville, North Carolina 28115 To whom it may concern: Subject: Fast Track Sewer System Application Trivium East Sewers CEC Project 315-976 Civil & Environmental Consultants, Inc. RECEIVED/NCDEQ/DUV'R JAN 1 4 tJ22 MOORESVILWOROS LE REGIONAL OFFICE Attached for your review and approval are the following items for Fast Track Sewer System Application permitting for Trivium East Sewers, located off Startown Road in Hickory, NC: • One (1) check written to the amount of $480.00 for application fee. Check made payable to North Carolina Department of Environmental Quality (NCDEQ); • One (1) original and one (1) copy of the completed and executed Fast Track Application; • One (1) original and one (1) copy of the completed and executed Flow Tracking/Acceptance Form; • One (1) copy of an 8.5" x 11" USGS topography map; and • One (1) aerial map of project area. The proposed project involves the construction of 8-inch and 12-inch diameter gravity sewers to serve the proposed development residential and industrial development in the area. Should you have any questions or require any additional information in support of this application, please do not hesitate to contact me at 980-237-0373. Sincerely, CIVIL & ENVIRONMENTAL CONSULTANTS, INC. Matthew Johnson Shad Walters, PE Asst. Project Manager Vice President CC: Shawn Pennell, City of Hickory Attachments 3701 Arco Corporate Drive, Suite 400 I Charlotte, NC 28273 I p: 980-237-0373 f: 980-237-0372 I www.cecinc.com Division of Water Resources Application Number:WO 0143 I b3 State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOC.UEMENETDANTCION O/DwR (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Hickory (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Warren Wood per 15A NCAC 02T .0106(b) Title: City Manager 4. Applicant's mailing address: 76 N Center Street City: Hickory State: NC Zip: 28601- 5. Applicant's contact information: Phone number: (828) 323-7412 Email Address: wwood@hickorync.gov II. PROJECT INFORMATION: 1. Project name: Trivium East Corporate Center Sewers 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Catawba 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.6882° Longitude: -81.2690° 5. Parcel ID (if applicable): 372115538314 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Shad Walters, P.E. License Number: NC P.E. 035796 Firm: Civil & Environmental Consultants, Inc. Mailing address: 3701 Arco Corporate Drive, Suite 400 City: Charlotte State: NC Zip: 28273- Phone number: (980) 237-0373 Email Address: swalters@cecinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Henry Fork WWTP Permit Number: NC 0040797 Owner Name: City of Hickory V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Unknown Downstream (Receiving) Sewer Size: 12 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): City of Hickory JAN 1 4 c'022 MO©RESVlLLE RETONAL OFF1( FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? El Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): Z Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities ® Businesses / offices / factories ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home 5. Nature of wastewater : 100 % Domestic/Commercial 0 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) �Is there a Pretreatment Program in effect? 6. Has a flow reduction been approved under 15A NCAC 02T .0.114(f)? ❑ Yes ➢ If ves, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) ❑ Yes ❑ No ® No Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Proposed Residential Development 120 gal/bedroom x 3 bedrooms/home = 360 gpd/home 82 homes 29,520 GPD Proposed Industrial Development 880 gal/acre 95 acres 83,600 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 113,120 GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 113,120 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 1425 PVC 12" 920 PVC 12" 285 Ductile Iron i�Zos ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: N/A 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(fl & (g) ➢ 15A NCAC 02T.0305(fl contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch ® Yes ❑ No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ® Yes ❑ No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I hlarr h Wood, Co-, IVIQnceger (Signature Authority's name & title from Application Item I.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: FORM: FTA 04-16 Page 5 of 5 'sion of ' ter Res s State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Hickory Project Name for which flow is being requested: Trivium East Corporate Center Sewers More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Henry Fork WWTP b. WWTP Facility Permit #: NC0040797 All flows are in MGD c. WWTP facility's permitted flow 9.0 d. Estimated obligated flow not yet tributary to the WWTP 1.8541 e. WWTP facility's actual avg. flow 2.712 f. Total flow for this specific request 0.1131 g. Total actual and obligated flows to the facility 4.8711 h. Percent of permitted flow used 54.12% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Clark Creek 3.5 1.4 .6789 0.6420 1.2078 .0790 Sandy Ford 4.32 1.728 .9470 0.6457 1.4797 .1352 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Hickory Collection System Downstream Petiuit Number: WQCS00020 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Warren Wood certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to tfnsport and treat the proposed new wastewater. Signing Ofcial Signt City Manager Title of Signing Official \--L'a21) Date Page 2 of 6 FTSE 10-18 REFERENCE 1. U.S.G.S. 7.5' TOPOGRAPHIC MAP, HICKORY QUADRANGLE, NORTH CAROLINA DATED: 2016. SCALE IN FEET 0 2,000 4,000 ay ,ii Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive • Suite 400 • Charlotte, NC 28273 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com TRIVIUM CORPORATE CENTER TRIVIUM EAST SEWERS STARTOWN ROAD HICKORY, NORTH CAROLINA 28658 SITE VICINITY MAP DRAWN BY: ERR CHECKED BY: MRJ DATE: JANUARY 2022 DWG SCALE: 1 "=2,000' APPROVED BY: PROJECT NO: SWW 315-976 FIGURE NO.: 1 P. \ 310-000 \ 315-976 \ -CADD \ Dwg `CV01 \ 315976-FIG-2-SITE AERIAL MAP. dwgfF/G-2-SITE AERIAL MAP./ LS:(1/13/2022 - ereichenbach) - LP: 1/13/2022 12:59 PM REFERENCE 1. AERIAL MAP VIA BING IMAGES, ACCESSED JANUARY 13, 2021. SCALE IN FEET 0 1,000 2,000 /ffiffrirjr/ i Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive • Suite 400 • Charlotte, NC 28273 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com TRIVIUM CORPORATE CENTER TRIVIUM EAST SEWERS STARTOWN ROAD HICKORY, NORTH CAROLINA 28658 SITE AERIAL MAP DRAWN BY: ERR CHECKED BY: MRJ APPROVED BY: SWW DATE: JANUARY 2022 DWG SCALE: 1 "=2,000' PROJECT NO: 315-976 FIGURE NO.: 2