Loading...
HomeMy WebLinkAboutWQ0035784_Additional Information Request_20220106ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director SEAN DWYER — EXECUTIVE DIRECTOR WALLACE LOFT LLC 5 BRYANT PARK, 28Tu FLOOR NEw YORK, NEw YORK 10018 Dear Mr. Dwyer: NORTH CAROLINA Environmental Quality January 6, 2022 Subject: Application No. WQ0035784 Additional Information Request The Cottages of Boone Wastewater Irrigation System Watauga County Division of Water Resources' Central and Regional staff has reviewed the application package received November 2, 2021. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on February 7, 2022. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through O, or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with an electronic copy submitted to my attention at the address below or the our upload site (URL: https://edocs.deg.nc.gov/Fonns/NonDischarge-Branch-Submittal-Form-Ver2). If you have any questions regarding this request, please do not hesitate to contact me at (919) 707- 3660 or Lauren.Plummer(ancdenr.gov. Thank you for your cooperation. Sincerely L4DuSi,gned by:.Pln. P.GUA,P—�� 45I�&&Plummer, Engineer III Division of Water Resources cc: Jeff Poupart, Section Chief, Water Quality Permitting Section (Electronic Copy) Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) Donald Feller, ORC — Envirolink, Inc. (Electronic Copy) Permit Application File WQ0035784 E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROHNA - DePemmencatE.W —rdalQuari /� 919.707.9000 Mr. Sean Dwyer January 6, 2022 Page 2 of 4 A. Application Fee: 1. Not applicable. B. Application: 1. Within Section IV — Billing Information, an address of 615 Fallview Lane, Boone, NC 28607 was provided. This appears to be the facility address. The mailing address listed for Wallace Loft LLC per the Secretary of State business registration records, and our records for the billing address of the facility, is 2626 Glenwood Avenue, Suite 550, Raleigh, NC 27608. Please confirm that the Permittee wishes to change the billing address to 615 Fallview Lane, Boone, NC 28607. Within Section V — Operation in Responsible Charge (ORC) Information, a back-up ORC has not been designated. Pursuant to 15A NCAC 02T .0117(a), the designation of both an ORC and a Back -Up ORC are required by the Water Pollution Control System Operators Certification Commission (WPCSOCC). Please designate a back-up ORC and update the records as needed with WPCSOCC. 3. There appears to have been some confusion with regards to Section VI — Open -Atmosphere Structures. The Freeboard (ft) does not refer to the diameter of the tank structure. Freeboard is the distance between the designed full waterline and the top of the structure. Pursuant to 15A NCAC 02T .0505(d), the freeboard in the open -atmosphere storage units must be at least two feet. Please revise as needed. 4. The "Relationship Type" for the related collection system permit (WQCSD0738) is incorrect. Please select the correct relationship type (i.e. Upstream Sewer) from the drop -down menu. 5. The deeded owners listed in Section IV — Irrigation Fields appear to be incorrect. Attachment B of the existing permit dated October 25, 2017 indicates that the fields are located on parcels owned by Wallace Loft LLC and not CCC-Boone, LLC. Please confirm that the deeded owner of the parcels receiving wastewater irrigation activity is Wallace Loft LLC and revise the table accordingly. C. Attachment A —Site Map: 1. No comment. D. Attachment B — Signature Authority Delectation: 1. The applicant indicated that the signature authority provided in Section I, Item 3 of the application requires a designation letter pursuant to 15A NCAC 02T .0106(c). The delegation letter was not provided within the uploaded submittal. Please provide the delegation letter for our review. E. Attachment C —Flow Reduction: 1. Not applicable. Mr. Sean Dwyer January 6, 2022 Page 3 of 4 F. Attachment D — Certificate of Public Convenience and Necessity: 1. Not applicable. G. Attachment E — Operational Agreement: 1. The response under Attachment E indicated that the applicant is a Developer of Lots to be Sold. Pursuant to 15A NCAC 02T .0115(a)(2), an executed Operational Agreement form is to be provided. This form was not included within the uploaded submittal. Please provide an executed copy of the appropriate Operational Agreement form for our review. H. Attachment F — Demonstration of Future Wastewater Treatment Capacities: 1. Not applicable. I. Attachment G— Property Ownership Documentation: 1. Within Attachment G, the Permittee indicated that they do not own all of the land associated with the wastewater collection, treatment, conveyance, and irrigation system. Please provide additional information pertaining to this response including a copy of all easements, lease agreements, and encroachment agreements necessary for the Permittee to operate and maintain The Cottages of Boone wastewater treatment and irrigation system. J. Attachment H —Affiliations: Within Attachment H, the applicant has indicated that the affiliations of record are correct. Our database indicates the following individuals as being affiliated with this permit. Sean Devine, Sylvester Brandon, and Ashley Vargo. The applicant information provided is for Sean Dwyer, and it is unclear whether the other individuals are still associated with this facility and permit. Please check the affiliations on our website (Affiliations Check URL) and confirm that all listed affiliations are accurate and up-to-date. If the current affiliations listed are no longer correct, please provide us with the correct individuals and their contact information so that our records may be updated. K. Attachment I — Compliance Schedules: 1. Not applicable. L. Attachment J — Civil Penalties and Outstanding Violations: Per the Notice of Deficiency dated October 25, 2021, please indicate whether the following deficiencies have been addressed: 1) Has the Spill Response Plan required under Condition IIL 1 of the existing permit been updated and posted at the requested locations? 2) Have the repairs to the wet weather storage tank, anoxic tank, freeboard marker, and rain sensor been made? Please provide an update on the status of these deficiencies and items of concern. If the Spill Response Plan has been updated, then please provide a copy for our records. Mr. Sean Dwyer January 6, 2022 Page 4 of 4 M. Attachment K—Industrial Wastewater: 1. Not applicable. N. Attachment L — Setback Waivers: 1. Not applicable. O. Additional Documentation: ➢ Existing Permit: 1. Please review the facility description in the existing permit and confirm that the remaining treatment components are still installed. ➢ Site Inspection by Regional Staff: During the recent site inspection, it was noted that a valve transferring wastewater from the equalization (EQ) basin to the rotary brush screen had been installed. The installed valve appears to serve as a bypass. Pursuant to 15A NCAC 02T .05050), bypasses and overflows are prohibited. This change was made without a permit modification, and the valve should either be removed or a permit modification - including the necessary engineering documents (i.e. plans and specifications), appropriate application form, and information regarding the purpose of the valve - should be submitted for our review. Please provide additional information and explanation of the valve installed between the EQ basin and the rotary brush screen, and the Permittee's plans for the valve.