Loading...
HomeMy WebLinkAboutSW6211101_Plansheet C15 - Notes_20220105PROJECT INFORMATION: PROJECT LOCATED IN PHASE II AREA RIVER BASIN: CAPE FEAR WATERSHED DISTRICT: NA FLOOD ZONE: MINIMAL FLOOD RISKAS PER DFIRM 37085 C PANEL 9588 WETLANDS: DELINEATED BY HAL OWEN & ASSOCIATES (2-9-2021) AS SHOW IN PLANS. WETLANDS WON'T BE DISTURBED. SOILS: SHOWN IN SHEET C13 THE SITE IS MOSTLY WOODLANDS. 11-10-2021 PROJECT IS LOW DENSITY. STORMWATER WILL BE MANAGED BY CONVEYANCE SWALES ALONG THE ROADS AND DISPERSED FLOW IN THE LOTS. TWO DRY PONDS WILL BE INSTALLED TO REDUCE THE POST -DEVELOPMENT FLOW IN ACCORDANCE WITH TITLE 15 NCAC 2H.1000 AND S.L. 2006-246, THE STORMWATER MANAGEMENT REGULATIONS, DEED RESTRICTIONS AND PROTECTIVE COVENANTS ARE REQUIRED FOR LOW DENSITY RESIDENTIAL SUBDIVISIONS WHERE LOTS WILL BE SUBDIVIDED AND SOLD. DEED RESTRICTIONS AND PROTECTIVE COVENANTS ARE NECESSARY TO ENSURE THAT THE DEVELOPMENT MAINTAINS A "BUILT -UPON" AREA CONSISTENT WITH THE APPLICABLE REGULATION GOVERNING THE DENSITY LEVEL. Conveyance Swale Design Information based on th 10 yr-storm -Mason Ridge Swale No. Drainage Area ac Impervious Area ac Pervious Area (ac) C Q (cfs) Slope (%) V allow (f s Vactual (fps) Flow Depth ft Type Side Slope Bottom Width (ft) Freeboard Top Width (ft Liner 1 0.27 0.08 0.19 0.39 0.84 4.7 4.5 1.26 0.5 TRI 4:1 0 0.5 8.00 Straw with Net 2 1.42 0.15 1.27 0.23 3.34 5.50 4.50 2.31 0.65 TRI 4:1 0 0.5 9.20 NC Green C125 3 0.20 0.05 0.15 0.35 0.55 5.50 4.50 0.97 0.50 TRI 4:1 0 0.5 8.00 Straw with Net 4 0.74 0.29 0.45 0.46 2.69 5.00 4.50 1.80 0.70 TRI 4:1 0 0.5 9.50 NC Green C125 5 0.32 0.08 j 0.24 0.35 0.88 4.70 4.50 1.26 0.50 TRI 4:1 0 0.5 8.00 NC Green C125 6 0.88 0.31 0.57 0.43 2.98 5.60 4.50 2.21 0.60 TRI 4:1 0 0.5 8.80 NC Green C125 7 0.75 0.28 0.47 0.45 2.64 5.60 4.50 2.21 0.60 TRI 4:1 0 0.5 8.80 NC Green C125 8 0.21 0.07 0.14 0.42 0.69 1.00 4.50 0.47 0.75 TRI 4:1 0 0.5 10.00 Straw with Net 91 1.68 OASI 1.23 0.36 4.80 4.90 4.50 2.68 0.70 TRI 4:1 0 0.5 9.60 NC Green C125 10 0.46 0.10 0.36 0.32 1.17 4.90 4.50 1.28 0.50 TRI 4:1 0 0.5 8.00 Straw with Net 11 5.65 1.50 4.15 0.36 16.07 2.431 4.50 2.94 1.20 TRI 4:1 0 0.5 13.60 NC Green C125 12 2.07 0.52 1.55 0.35 5.70 3.60 4.50 2.51 0.80 TRI 4:1 0 0.5 10.40 NC Green C125 13 0.31 0.10 0.21 0.41 0.99 3.60 4.50 1.03 0.60 TRI 4:1 0 0.5 8.80 NC Green C125 14 1.77 0.17 1.60 0.30 4.17 3.20 4.50 0.96 0.60 TRI 4:1 0 0.5 6.60 NC Green C125 15 1.94 0.79 1.15 0.48 7.25 1.00 4.50 1.461 1.201 TRI 4:1 0 1 0.5 13.60 NC Green C125 16 0.51 0.05 0.461 0.30 1.20 1.90 4.50 0.90 0.60 TRI 1 4:1 0 1 0.5 1 8.80 NC Green C125 PROVIDE O.S' FREEBOARD MINIMUM. TOP WIDTH IS AT FREEBOARD USE BERMUDA GRASS OR EQUAL TYPICAL TRIANGULAR SWALE 1 "=20' SEE TABLE AT TOP OF THIS PAGE FOR DIMENSIONS AND LINER THE GRASS SPECIES IN THE SWALE SHALL BE: (A) NON -CLUMPING AND DEEP-ROOTED BERMUDA OR TALL FESCUE; (B) ABLE TO WITHSTAND A VELOCITY OF FOUR FEET PER SECOND; (C) MANAGED AT AN AVERAGE OF SIX INCHES; AND (D) NOT BE CUT LOWER THAN FOUR INCHES. (E) GRASS NEEDS TO BE WATERED FREQUENTLY FOR THE FIRST THREE WEEKS AFTER PLANTING. (F) IF GRASS IS NOT IN GOOD CONDITION, SOD WILL BE REQUIRED. 0.5' FREEBOARD 00. Or 4 a- Lu t] O J LL MASON RIDGE SUBDIVISION - BUILT UPON AREA - rev 1-3-2022 Total Property Area = 35 AC 1,524,600 SF Area below NHWL= 1.49 Ac 64,904 SF Total Project Area (TPA) = 33.51 Ac 1,459,696 SF Exist. Asphalt (EBUA)= 0 AC - SF DESCRIPTION NO. LOTS BUA (sf) TOTALBUA sf Proposed Roads Asphalt 92300 92,300 Proposed Lots BUA 49 5000 245,000 Mail sidewalk -kiosk 1,000 TOTAL BUA 338,300 15A NCAC 2H .1003(1): CALCULATION OF PROJECT DENSITY. (b) A project with existing development may use the calculation method in Sub- Item (1)(a) or shall have BUA INCLUDES (IMPERVIOUS SURFACE AND PARTIALLY IMPERVIOUS SURFACE TO THE EXTENT THAT THE PARTIALLY IMPERVIOUS SURFACE DOES NOT ALLOW WATER TO INFILTRATE THROUGH THE SURFACE AND INTO THE SUBSOIL: BUILDINGS, SIDEWALKS, DRIVEWAYS. "Built -upon area" does not include: - a slatted deck; - the water area of a swimming pool; - a surface of number 57 stone, as designated by the American Society for Testing and Materials, laid at least four inches thick over a geotextile fabric; - a trail as defined in G.S. 113A-85 that is either unpaved or paved as long as the pavement is porous with a hydraulic conductivity greater than 0.001 centimeters per second (1.41 inches per hour); or - landscaping material, including, but not limited to, gravel, mulch, sand, and vegetation, placed on areas that receive pedestrian or bicycle traffic or on portions of driveways and parking areas that will not be compacted by the weight of a vehicle, such aS THE AREA BETWEEN SECTIONS OF PAVEMENT THAT SUPPORT THE WEIGHT OF A VEHICLE. BOTTOM WIDTH TYPICAL TRAPEZOIDAL SWALE 1 "=20' (1) TBUA - EBUA 338,300 - 338,300 sf (2) TPA-EBUA = 1,459,696 - 1,459,696 sf PROJECT DENSITY = (1) / (2) 23.18% Since the density is less than 24% it is a Low Density Project REV # OF LOTS 1 /5/2022 w J m 0 I- tln Ln J a Ln M 0 0 a N O N 6 c-I c-I a m w tln w N N 0 N lI1 U o U CT Ln Louo ,¢,��1,321 Cn= M M tl � 10 Otl--tl N L C wv7z..>✓ J O w nzz� c ,r, zXao °'mac' OU0�a� 3 E w LL 0 U U) W J N �Z� Q = U Q W W U W W J Q = } O a z W _ ? Q Z� m W 02 U QHzzO� E� z 0n- WnWU�Lu <U<az<-�oz WLu WQ��zpW O m �W U Oa Um a~W H0<zOfU)0 Qz W J U U) N O N LO N 0O w a 0 n = N � U OOzo Cr m Q m a�'�C� LL X p rn N 0 a t O = � w d CO C) z J LL LU 2 W a z LU C> G 0 U) rW V 0 ry z O 0 C15 FILE: FOR AGENCY REVIEW 1-5-2022 ICP-202101-MASON RIDGE