Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0034650_Regional Office Historical File Pre 2018
Beverly Eaves Perdue Governor Mr. Andy Lucas County of Stanly 1000 North First Street Albemarle, North Carolina 2S001 ©ear M Lucas; NCDENR North Caro. na Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Dee Freeman Director Secretary April 2S, 2010 Subject: Permit No. WQ0034650 Clete Road Subdivision Low Pressure Sewer System Stanly County In accordance with your express permit application received March 18, 2010, and additional information received by the Division of Water Quality (Division), we are forwarding herewith Permit No. WQ0034650 dated April 28, 2010, to the County of Stanly for the construction and operation of the subject wastewater collection system, This Permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. If any parts, require' eats, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the approved plans and specifications. Mail the Certification to the Construction Grants & Loans Section, 1633 Mail Service Center,. Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) One set of approved plans and specifications is being forwarded to you. J 617 ~tail ,Servi e Center, Raleigh, Lrocati n:512 N, Salishury St_ RAI Phone: 919-807-6J4a' FAX:6t9-80 Internet nwvrxovateryraiityorg Ar Equal Opportunity'. Art,rrnatiye, Ainon E, Nor,h )IIf 27604 One NorthCaroiina aft/lall Mr. Andy Lucas April 28, 2010. Page 2 If you need additional information concerning this matter, please contact Adrian Eaton, State Review Engineer, at (919) 715-3283 or Seth Robertson, P.E. at (919) 715-6206. Sincerely, Coleen H. Sullins aelsr cc: Mr. Stephen G. Chambers, P.E., Chambers Engineering, PA., PO Box 1726, Albemarle, North Carolina 28002 DWQ Mooresville Regional Office, Surface Water Protection (Permit No. NC0024244) Stanly County Health Department Permit Application File WQ0034650 I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO THE COUNTY OF STANLY FOR THE construction and operation of a low pressure sewer system consisting of approximately 468 Iinear feet of 2-inch pressure sewer, approximately 3,046 linear feet of 2.5-inch pressure sewer, 26 simplex pump stations with on -site audible and visual high water alarms to serve 26 3- bedroom single family residential units as a part of Clete Road Subdivision, and the additional discharge of 9,360 GPD of collected wastewater into the Long Creek WWTF (Permit No. NC0024244) sewerage system pursuant to the permit application received on March 18, 2010, and subsequent additional information received by the Division, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and Iimitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0400: (a) The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. (b) A map of the sewer system shall be developed and actively maintained. County of Stanly April 28, 2010 Permit No. WQ0034650 Page 2 (c) An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response shall be developed and implemented. (d) Pump stations that are not connected to a telemetry system (i.e., remote alarm system) shall be inspected by the permittee or its representative every day (i.e., 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. (e) High -priority sewers shall be inspected by the permittee or its representative at least once every six -months and inspections are documented. ( A general observation by the permittee or its representative of the entire sewer system shall be conducted at least once per year. (g) Overflows and bypasses shall be reported to th.e appropriate Division regional office in accordance with 15A NC.AC 02B .0506(a), and public notice shall be provided as required by G.S. 143-215.1 C. (h) A Grease Control Program shall be established as follows;. (i) For publicly owned collection systems, the Grease Control Program shall include at least bi-annual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors for new construction and retrofit, if necessary, of grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors,. enforcement for violators and the legal. means to control grease entering the system from other public and private satellite sewer systems. (ii) For privately owned collection systems, the Grease Control Progra.nt. shall include at least bi-annual. distribution of grease education. materials to users of the collection system by the permittee or its representative. Grease education materials shall be distributed more often than required in Parts (i) and (ii) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. (i) Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility.. (l) Documentation shall be kept for Subparagraphs (a) through (i) for a minimum of three years with exception of the map, which shall be maintained for the lire of e system. 4. The sewage and wastewater collected by this system shall be treated in the long Creek WWTF (Permit No. NC0024244) sewerage system prior to being discharged. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit requestmust be submitted to the Division accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. rCounty of Stanly April28, 2010 ermit No. WQ0034650 Page 3 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Construction Grants & Loans Section, 1633 Mail Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) 9. FaiIure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The Permittee shall provide for the pump station and force main the following items: (a) Pump Station Reliability: (i) Pump stations, except when exempted by Subparagraph (j)(2) of 15A NCAC 02T.0305, shall be designed with multiple pumps such that peak flow can be pumped with the largest pump out of service. (ii) A standby power source or pump is required at all pump stations except for those pump stations subject to Subparagraph (j)(2) of 15A NCAC 02T.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. (iii) As an alternative to Part (ii) for pump stations with an average daily design flow less than 15,000 gallons per day as calculated using 15A NCAC 02T.0114, a portable power source or pumping capability may be utilized. It shall be demonstrated to the Division that the portable source is owned or contracted by the perrnittee and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. County of Stanly April 28, 2010 Permit No. WQ003465t0 Page 4 (iv) As an alternative to Part (ii) for pump or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24-hours worth of wastewater storage or, exceed the greatest power outage over the last three years or the documented response time to replace a failed pump, whichever is greater. Documentation shall be required pursuant to the permit application. (v) All pump stations designed for two pumps or more shall have a telemetry system to provide remote notification of a problem condition to include power failure and high water alarm. (vi) High water audio and visual alarm. (h) Pump stations shall have a permanent weatherproof sign stating the pump station identifier, 24-hour emergency number and instructions to call in case of emergency.. Simplex pump or vacuum stations serving a single-family residence shall have a placard or sticker placed inside the control panel with a 24-hour emergency contact number. (c) Screened vents for all wet wells. (d) The public shall be restricted access to the site and equipment. (e) Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. . In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required by this Division, such as the construction of additional or replacement wastewater collection facilities, 13. The facilities shall he constructed in accordance with the requirements of the North Carolina Sedimentation Pollution Control Act. 14. If applicable,. the operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is made a condition of this Permit. Noncompliance with the terms of the Operational Agreement may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 1.43-215.6A to 143-215.6C. A copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed shall be submitted with the engineer's certification prior to operation. 15. Any abandoning of the existing ill es must be done in accordance with the requirements. of the Division's Mooresville Regional 16. Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Mooresville Regional Office, telephone number (704) 663-1.699„ as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: rCounty of Stanly April 28, 2010 Permit No. WQ0034650 Page 5 (a) Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. (b) Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858- 0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition I(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 17. The Permittee shall maintain on hand for immediate installation a supply of spare, fully operational pump units of each type used in the pressure sewer system. The number of pumps on hand shall not be less than 10 percent of the number of installed units or one unit, whichever is greater. 18. Pursuant to the documentation provided by the County of Stanly, dated April 1, 2010 (see Attachment A), all wells within 100 feet of a sewer appertenance, must be properly abandoned in accordance to NC rules and regulations. The abandonment process shall be performed by a NC certified well contractor. A copy of the well abandonment form for each well must be received by the Division prior to putting any affected line in service. Permit issued this the 28th Day of April 2010 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION `lvi . ,� Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. WQ0034650 County of Stanly Permit No. WQ0034650 Clete Road Subdivision Low Pressure Sewer System Issued April 28, 2010 ENGIN} ERAS CERTIFICATION as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the Low Pressure Sewer System serving the Clete Road Subdivision, located in Stanly County, hereby state that to the best of my abilities, due care and diligence was used in the observation of the following construction: a low pressure sewer system consisting of approximately 468 linear feet of 2-inch pressure sewer, approximately 3,046 linear feet of 2.5-inch pressure sewer, 26 simplex pump stations with on -site audible and visual high water alarms to serve 26 3-bedroom single family residential units as a part of Clete Road Subdivision., and. in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. 1 certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No. Date Mail this Certification to: DENR/DWQ Construction Grants & Loans Section 1633 Mail. Service Center Raleigh, North Carolina 27699-1633. Note: if the wastewater collection permit eras issued to a private entity under an Operational Agreement with the Environmental Management Commission, then a copy of the Articles of Incorporation, Declarations, and. Bylaws that have been properly filed with the applicable County's Register of Deeds shall be submitted with this certification. Or'FICE, Or 'nit COUNTY A r(0P lEY Pr10l1E (704) 986-J000 FAX (7o.11 083•3133 STANLY COUNTY 1 000 Ngnrrr FIRST 5TR[C.T, Sala ICI Al I) MARI_I . mon ft) CARD) 1; 1A 2 600 i April 1, 2010 NC Division of Water Quality — CG&L Section Mr, Adrian Eaton 2728 Capital Blvd. Raleigh, NC 27604 Re: County of Stanly Clete Road CDBG Improvements - NC DENR WQ0034850 Dear Mr. Eaton: Please consider this correspondence in regards to the above referenced project. On behalf of the County of Stanly t would like to extend my appreciation for your time and efforts in this matter, In regards to the provision of Public Sanitary Sewer services contemplated under the requested permitting action. NC DENR W00034550. please be advised and take notice that the County of Stanly will not provide. allow, or otherwise initiate said service Inconsistent with NC General Statutes and NCAC Title 15A Subchapter 2T, "Waste Not Discharged to Surface Waters.' To that extent the County of Stanly will require that individual, private wells within 100-FT of any proposed simplex grinder pump be abandoned with said abandonment being certified by the Stanly County Board of Health. In no instance shall sewer service be provided or a pump Installed until such time that the requesting property owner provide evidence of abandonment of any well in conflict. For your use please find attached a listing of all affected properties. The proposed project, as I am sure you are aware, also includes provisions for new Public Water distribution facilities. It is planned that all potential customers in the project area will connect to the Public Water facilities thereby rendering private wells unnecessary. Again, thank you for your time in this matter. Sincerely, PAT Je niter R. Furr, Attorney County of Stanly Attach: Address Listing cc: Donna Davis, Stanly County Public Utilities Stephen Chambers, Chambers Engineering, PA • i.lOA Fzr,;1w;ri,J Attc hsnt A a .'0 II i2 3 18 9 21 22 23, 24 25 26 6..24 2 s° KO `.fb 87i" g,p3 A80C'. Burns Rc., 5 63 {1t" SR ..Ahem A, • arl NC 29 Cet • AIhsN•na.r1r4, NC 230).1 •At,Q narks it. 253(01 ..N13 2505.. . Address My am 5 ' 3620 "ye551, zSi2.1 Mye6 20