Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
wq0032207_Regional Office Historical File Pre 2018
y, Governor William 444444414 "V6'. V:11. I „ G, Ross Jr., Secretary North Carolina Department of Environment and Natural Resources !`40 \I' I ln; 20'7 Coleen H. Sullins, Director Division of Water Quality Honorable Harold Greene, Mayor City of Locust 211 Towne Centre Drive Locust, North Carolina 28097 November 13, 2007 NC DENR mrm Surface Wcier Prof:,, Subject: Application No. WQ0032207 Additional Information Request Abi's Place Subdivision Wastewater Collection System Extension Stanly County Dear Mayor Greene: The Pretreatment, Emergency Response and Collection System Unit has conducted a preliminary review of the subject permit application package. Additional information is required before we can continue our review. Please address the attached items no later than December 13, 2007. Please note that comments from the Regional Office are pending at this time, and additional requests may be necessary to address these comments, Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. In addition, any omissions made in responding to the above items may result in future requests for additional information. Please reference the subject application number when providing the requested information. Two copies of all revised and/or additional documentation should be signed, sealed, dated, including a point -by -point response to the items in the letter, and submitted to my attention at the address below. Please note that failure to provide this additional information on or before the above requested date may result in your application being returned as incomplete, If you have any questions regarding this request, please do not hesitate ontact me at (919) 733-5083, extension 375. Thank you for your cooperation. Environmental Engineer cc: Ms. Dee Browder, Mooresville Regional Office, Surface Water Protection Section Mr. Stephen Chambers, P. E., Chambers Engineering, PA, R. O. Box 1726, Albemarle, NC 28002 Permit Application File WQ0032207 Pretreatment, Emergency Respone & Collection Systems Unit Location: 512 N. Salisbury St Raleigh, NC 27604 Internet: www ncwatenquality.org 1617 .Mail Service Center Phone (919) 733-5083 Fax (919) 733-071.9 An Equal Opportunity/Affirmative Action Employer - 50% Recyded/10% Post Consumer Paper Raleigh, NC 27699-1617 Customer Service 1-877-623-6748 N°pTincarolina ,Naherally City of Locust Abi's Place Subdivision Pressure Sewers Application Number WQ0032207 Review Comments November 13, 2007 General 1. Based on the A/E's certification in the Permit Application that all 15A NCAC 2T.0300 requirements regarding gravity sewers and force mains, and the Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 have been met, a review of these items has not been performed. It shall be the permittee's responsibility to ensure the plans and specifications meet the appropriate design criteria and rules. Final approval of these documents will not imply approval of any variance from these criteria unless specifically requested and granted. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A— 143-215.6C, construction of additional facilities, and/or referral of the N.C. Professional Engineer to the licensing board. 2. Application, Part IV.5 - Please provide the permit number for the downstream sewer. It is required so that the project certification can be verified. (No. is WQ0023594). Note that only a partial certification has been received. Provide documentation to show that the portion where this projects connects (and downstream thereof) has been certified. 3. Application, Part 1V.3 - The emergency storage value given here is not acceptable. As shown in the calculations, 147 gallons above the alarm elevation is required. See attached reliability policy and Plan Comment 6.b. 4. Application, Part V.4 - This indicates that the entire project is not subject to flooding. Provide a letter signed and sealed by the engineer stating this fact and referencing the source of the information. 5. The Watershed. Classification form has not been completed by the regional office as required. 6. Provide a sketch for the buoyancy calculations for the pump stations showing all relevant dimensions used in the calculations. Specifications 1. Section 02660 a. This applies to Water Main Construction. There is no similar section for Sewer Force Main Construction. Confirm if this section is to apply to sewer construction, or provide the appropriate section. b. Part 1.1.B.3 - There is no Section 02224 in these specifications as noted here. c. Part 1.1.B.12 - There is no Section 15114 in these specifications as noted here. 2. Section 11060, Part 3.1 - There is no Section 11005 in these specifications as noted here. 1 3. Section 15060, Part 3.6 - The regulatory vertical separation between water pipes and sewer pipes is 18 inches. 4. Provide specifications for the ARVNacuum release valves. 5. Provide specifications for the required check valves. Plans 1. Show match lines for all line continuations. 2. Show all fitting (valves, tees, reducers, etc.) in both the plan and profile views. 3. Sheet 4 a. 2-Way cleanouts are not recommended as they can flush solids back up the line. All cleaning should be directed to moving solids from the system. b. The required storm sewer separation is now 24 inches (15A NCC 02T .0305 (f)). 4. Sheet 6 - In -line cleanouts should be installed on both incoming lines at junctions. 5. Sheet 9, Thrust Block Detail - This is different from the detail on Sheet 10 (Sheet 10 omits the reference to 1.5-inch pipe). 6. Sheet 11 a. The vent on the service line from the house is not required, only the pump station vent. This vent must open 24 inches above the 100-year flood elevation. If retained the vent must be equipped with an insect screen. b. Pump Station Detail - Show the pump on and alarm elevations so that the emergency storage can be verified. c. Pump Station Detail - Label the ground surface elevation and note to slope away from top. d. Pump Station Detail - Note that the amount of concrete used for ballast can be reduced by taking into account the weight of soil above the extended base. e. Pump Station Detail - Indicate the material for the lift out chain. f. Pump Station Detail - Show an insect screen on the pump station vent. 2 illirrr- Policy for Meeting the Reliability Requirements of 15A NCAC 2T .O3O5(h)(1)(D) for Pressure Sewers Utilizing Simplex Pump Stations These rules require that multiple pumps be provided with the capacity to pump peak flow with the largest pump out of service and to provide power reliability respectively. Simplex pump stations will only be approved for single family residences, all other pump stations shall be required to meet these rules. To help ensure protection from overflows for simplex pump stations, the following policy will be implemented in lieu of requiring dual pumps and power reliability. The first option for meeting reliability requirements is to provide 24 hours storage in the wet well above the pump -on elevation as requested in the permit application. However, since this may add to the cost and make installation difficult in certain areas, another option may be pursued. Alternatively, the applicant may provide documentation regarding both power reliability and response times for pump replacement. In the case of power reliability, 3 years of power history data in the area from the power company must be provided. The amount of storage required shall be equal to the duration of the longest power outage (minus catastrophic events such hurricanes). Storage shall be provided above the pump -on elevation. For response times, the applicant shall provide an estimate of the response time to replace a failed pump. The estimate shall include time for answering after hours calls, travel time to maintenance shop, preparing equipment to respond, travel time to site, and time to replace the pump. For existing systems, the Permittee should indicate if they currently maintains a supply of pumps on hand at this time (a permit condition). Also, personnel must be on -call 24 hours a day, 7 days a week as well as a phone number with 24-hour answering service clearly posted on the pump station. Storage shall be provided above the high water alarm. A minimum of 120 gallons of storage above alarm shall be included in the evaluation. These storage requirement are not cumulative, rather, the storage which provides the Largest wet well shall be specified. 3 Michael F. Easley, Governor William G. Ross Jr„ Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality September 3.2007 HAROLD GREENE CITY OF LOCUST 21 1 TOWNE CENTRE ©RIVE LOCUST NC 28097 Subject: Acknowledgement of Application No, WQ00322t17 Abs Place Subdivision Wastewater Collection System Extension Stanly County Dear Mr. Greene, Mayor: The Division of Water Quality (Division) acknowledges receipt of your permit application and supporting materials on August 30, 2007. This application package has been assigned the number listed above and will be reviewed by Adrian Eaton. The reviewer will perform a detailed review and contact you with a request for additional information if necessary. To ensure the maximum efficiency in processing permit applications, the Division requests your assistance in providing a timely and complete response to any additional information requests, Please note at this time, processing permit applications can take as long as 60 - 90 days after receipt of a complete application, To check on the status of an application, please visit http://h2o,enr.state.nc.us(birns/Reports/reportsPermits.html. The Division has recently reorganized. All sewer related matters are now handled through the Pretreatment, Emergency Response and Collection Systems Unit under the Point Source Branch EXCEPT FOR FAST -TRACK SEWER EXTENSION PERMITTING WHICH CONTINUES TO BE ADMINISTERED THROUGH OUR REGIONAL OFFICES. The Unit is located on the 131h floor of the Archdale building in downtown Raleigh. If you have any questions, please contact Adrian Eaton at 919-733-5083, extension 580, or via e-m Adrian,eaton@ncmail.net. If the reviewer is unavailable, you may leave a message, and they will respond promptly, PLEASE REFER TO THE ABOVE APPLICATION NUMBER Sincerely, ey Ob Poupart Supervisor AKING INQUIRIES ON THIS PROJECT. cc: Mooresville Regional Office, Surface Water Protection Section Stephen Chambers, PE Chambers Engineering, PA, PO Box 1726 Albemarle, NC 28002 Permit Application File W00032207, One thCarolina Noaturally Pretreatment, Emergency Response and Collection Systems Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 733-0059 Internet httpJ/h2o.enr.nc.state.uslndpu An Equal Opportunity Action Employer O f recycled/10% post -consumer paper