Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0040210_Regional Office Historical File Pre 2018
August 17, 2018 Jason Wilson City of Salisbury 1 Water Street Salisbury, North Carolina 28144 Subject: Permit No. WQ0040210 City of Salisbury Crane Creek Lift Station & Force Main Upgrade Wastewater Collection System Extension Permit Rowan County Dear Mr. Wilson: In accordance with your application received August 7, 2018, we are forwarding herewith. Permit No. WQ0040210 dated August 17, 2018 to the City of Salisbury (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This pertxtit shall not be automatically transferable; a request must be made and approved. Condition H.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 1.5 A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee, It shall be the responsibility of the Pernlittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office y 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 7C,1663 1699 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Lon Snider at (704) 235-2196 or via e-mail at lon.snider@ncdenr.gov. EA14CC681AF27425... by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Sincerely, DocuSigned by: cc: Charles Bramlett PE (E-copy) Mooresville Regional Office Files Water Resources Central Files PERCS (E-copy) Page 2 of 8 STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Salisbury Rowan County for the construction and operation of approximately 253 linear feet of 16-inch of gravity sewer & 3050 linear feet of 10-inch force main, for The Crane Creek Lift Station & force main upgrade, with an additional pump to the current triplex Cane Creek Lift Station to pump 810 & 1380 GPM at 118 & 162 feet of TDH and the discharge of 0 gallons per day of collected wastewater into the City of Salisbury existing sewerage system, pursuant to the application received August 7, 2018, and inconformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. ,—DocuSigned by: L—A14CC681AF27425.._ by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ By authority of the Environmental Management Commission Permit Number: WQ0040210 Permit Issued: August 14, 2018 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET City of Salisbury is hereby authorized to: Construct, and then operate pon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this systemshall be treated in the City of Salisbury Waste Water Treatment Facility in accordance with Permit Number NC0023884. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1.5A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional. Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS 1) No flow in excess of the quantity permitted herein, 0 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304 (b)]. 2) Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single- family residence may have a placard or sticker on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2)] H. STANDARD CONDITIONS This permit is not transferable, in the event there is a desire for the wastewater collection, facilities to change ownership, or there is a name change of the Peiwittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, [15A NCAC 02T.0110] This permit shall he effective only with respect to the nature and volume of wastes described in the application and other supporting data, [15A NCAC 02T .0110] Page 4 of 8 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of -these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be nnet: (15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry'System shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week e. High -priority sewer lines shall be inspected at least once per every six months and inspections documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g• Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.IC. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc., or b. Any SSO and/or spill, over 1,000 gallons.; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of EmergencyManagement at telephone number (800) 858-0368 or (91.9) 733-3300. Persons reporting any of the above occurrences shall file a spill report by .completing and submitting Part I of 'Form CS-SSO (or the ,most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the ,problem does not recur, Part 1I, of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SS° was beyond control, [G,S. 143- 21.5.1C(a1)1 Construction of the gravity sewers, pump stations, and force mains shall he scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass, discharge ofwastewater to the surface waters of the State. [15A. NC AC 02T.0108(b)] 7, Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater -flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the ,permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County'.s Register of Deeds office shall be submitted with the certification. A complete certification is one where the Rim is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc, b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times„ and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in, force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel tirneframes, shallbe provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary fomi. Page 6 of 8 Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and •approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: CITY OF SALISBURY PERMIT #: WQ0040210 PROJECT: CRANE CREEK LIFT STATION & FORCE MAIN UPGRADE ISSUE DATE: AUGUST 14, 2018 This project shall not be considered complete nor allowed to operate in accordance with standard Condition '7 of this permit until the Division has received this Certification and all required supporting documentation, It should be submitted. in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address. noted in the page tooter. Any wastewater flow made tributary to the wastewater collection system extension prior to .completion of this Certification, shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The 'Permittee is responsible for tracking all partial certifications up until a final certification is received by the Division, A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION the undersigned agent for the Pemintee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. ted Name, Tit Signature ENGMER'S CERTIFICATION Date as a duly registered Professional. Engineer in the State of North Carolina, having been authorized to Observe periodically, weekly, .] full time) the construction of the project nameand location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted .February 12„. 1996, as applicable; the Division's Minimum Design Criteria for the Fast-Tra.ck Permitting of Purnp Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials.. North Carolina Professional Engineer's Seal w/signature & date: L Final Partial (include description) Certification Comments/Qualifiers (attach if necessary): NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Mooresville Regional Office Phone: (704) 663-1699 FAX (704)-633-6040 Dlvislon of Water Resources Depa nn State of North Carolina nt of Environmental Quality Division of Water Resources 15A NCAC 01T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-1.6 & SUPPORTING DOCUMENTATION Application \umber All items t be completed ur the application r ill be returned APPLICANT INFORM .TI.ON.. r 1. Applicant's name: City of Salisbury (company, muruc.ip al.ity, I{OA, Applicant type: 0 Individual 0 Corporation [] Federal ❑ State/County 3. Signature atdi:hority's name: Jason t3'ifson per 15ANCAC 02 Title: Utilities Engineer,Maner 4, Applicant's mailing address: 1 'Water Street City: Salisbury Applicant's comae Phone number: (704) 216-7553 Email Address: PROJECT INFORMATION: Lip 2t1144- 1. Pro jec:t name: Crane teek_Lifr Station & Fcaa 'pgrade Application/Project status: ® Proposed (NeW Permit) If"a modification, provide the General Partners Municipal (bl pt t r by D\\ R.) g permit number: W'QOO and issued da If new construction but part of a master plan, provide the exist' 3. County where project is located: Rost ari 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.662 1" 5. Parcel ID (if applicable): (or Parcel II) to closest downstreun sewer) CONSULTANT INFORMATION: 1. Professional En Number: 037639 u ip Pritat. Other WQOO gitudc: w80,4262' }"irtti: 1lightill Intia tructurc 1 nginecring, PC: Mailing address: 301 North Main Street Suitc'2433 City°. Wniston-Salem State: NC Lip.. 7101- Plt«tte ttttnal er. (33Ci1 701-4tt1O ''mail Address: wbraanlett(a hiepc.com. IV. WASTEWATER TREATMENT FA I'TY (WWTF) INFORMATION: i, Facility Name: Town Creek Wastewatter Treatment Facility Permit Number: NCOO23Sf'4 ()wner Name.: City of Salisbury RECEIVING DOWNSTREAM SEWER INFORMATION (il`different than WW"TF): 1. Permit Numher(s): WQ Downstream (Race System Wide Collcctioot Su tent F'trtnit l ;umber(s)(ifapplica Other Narrte(s)' jt`y' of Salisbury SecterSi�:e' 42 inch 10019 -led Public Utility FORM: FTA 04-16 Page 1 of 5 L. GENERAL REQL.IIR1E lENTS 1, lithe Applicant is a Privately-Owr p icant is a Deveio e Applicant is a Hot gin of w a ed Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes No N/A lots to he sold, has a Dev sper's C2peratir n il. ❑ Yes ❑No ZN/A all that Z Residential Owned ® Residential Leased Z School./preschool/ day care Z Food and drink facilities Businesses / offices / factorit Nature of wastewater pty)� Retail (stores, centers, malls El Retail with food preparation' ❑ Medical ,' dental , veterinary fa Church ❑ Nursing Houle is stic/Commercial %Commercial 'al (See 15A NCAC 02'T .0103(201) s theie a Pretreatment Program in effect? Has a flows reduction been approved under ➢ 5A NCAC 02"➢, .01(4(fr ❑ Y w if veswpros°ide a cops of flow reduction approval letter 7. Summarize wastes ater generated by project: Establishrnent Type (see 02T.O114(0) Daily Design Flow Lb {FORMS: DE \ been attached? O.'y) been attached? ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse 'Swimming Pool/Filter Backwash ❑ Other ('Explain in Attachment) El Yes ❑No �No of units Flow GP[..) G,PD GPI) UPI) gal/ GPD 0 GPL) a Sew 15wa aC'/IC 02T .01 14(b),.(d), (e)(1) and (e)(2) for tweet to ww i tewwater design flo dwelling, proposed unknown non-residential develrwprnent uses; public access tit,cilities to and residential property located south or east of the Atlantic Intracoastal Waterway to be us in (3,' . 42 ' ), b Per 15A NCAC 02T ,01 l4(c), design flow rates for establishments not identified tin table 15A N-CAC 02T,0114J shall he deternisined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: (2 GPI) (per 1.5A, NCAC 02T,0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be pc ® Flow has already been allocated in Permit Number CS00t: b rates , minimum flow per tted near high public use areas; d as vacation rentals as detained equent permits that connect to this line ❑ Rehabilitation or replacement of existing sewer with no new flows expected ❑ Other (Liwplaain . FORM: LTA 04-16 Page 2of5 VII. SR. .VITY SEER DESIGN CRITERIA (If Applicable) 02°F n0305 : IDC (Gravity Servers) Summarize gravi eta be permitted. Size Ca hcs) 253 Material DI Section 11 III ol'tine MDC tcrr Pcrtatitting ttl'(irav it . Sewers contains information related to design criteria Section HI contains information related to rrtinimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VII1. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MSC (Pump Statie Mrainsp COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump stthon number or name: Crane Creek Lift Station ?. Approxirnate C'eac: t`elitaates (Decimal Degrees): Latitude: 35,2261" IMozr =itttele: itt,42E 2'.. 3. Design flow ot`tlnc ptttxtln station: 3,168 :millions gallon,, per day (t:)rsn capacity) 4. Operational point( s) of tlpump(s): J10 &,1.380 gallons per minute at 11.8 & I(i2 feet natal clvna 5. Sut:n.marize the force to be pert Size (inches) nce vv°ith °i'vt.]'r wC' 02T .030.}0h0( IU: tandby power source- or pump head (I"D1.1) is activation and telemetry- I.5A NCAC 02T.0305(h)( Required for all pump stations with an aver ag e daily thaw greater than or equal to 15,000 gallons per day Must he permanent to 'facility Cye if the pump station has an aver ss than 15 s per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NC"A ' t)2T .0305(h)(1)(C) or ❑ Portable putnpirtg unit rv'ittt phtgged r It shall be demonstrated to the O'ivi. u and is compatible with. the station, If the portable power source or punip is dedicated to multiple pump stations, an eval.uati capacities and the rotation schedule of the portable powersource or pump, inc n in the case oft multiple station power cottage. cy pump connection and telemetry. I5A NCAC 02T ,0305(h)(1)(C'): he portable source is o fed or contracted by the applicant (draft agreem Mall the put np static)rts° sec 1 tinnetramcs, shall be pro FORM: FTA 04-l6 Page 3 of 5 ' IX. SE'TB. CKS & SEPARATLO S (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all scpa ations found in 15A N 15A NCAC 02T.0 ,1)5(t) contains m Storm sewers and other act Water mains Water mains (horizontal) m. seruaraationt Setback Parameter* fisted below (vertical) ver sews including on benched trenches) Reclaimed water lines iwertiea1 rcclaainaed over sews Reclaimed water hues (horizeantal - reelaaitated over seaaet.) **Any private or public water supply source, ded reservoirs used as a 4 y wet Ovate .0305 ided fi ater s of Class' or **Waters classified WS (except WS-1 of WS-V), B, SA, DRW,'HQW, or SB from normal high water (or tide elevation) and wetlands (see itertt IX,2) *'"'Any oth ditches lake„ irnpoundmertt, or ground water lowering and surface drain Any building foundation Any baseme Topesiope_ot;emnhankrnent or cuts,of2 feet or rstore ofc.stical height Drainat.}e systems and interceptor drains Any swaitnm.ing pools Final earth grade (vent e.alj ® Yes. LI No s Separation Required 24 inches 18 inches 10 feet 18 inches 2 feet 100 feet 10 feet 10 feet 5 feet 36 inch.es 15A NCAC 02T,tt i451g} contains alternatives where separations in 021.0_305.L_p cannot be atcltie eel, **Stream classifications can be identified using the Division's NC Surface Wat:e jassif eati.ptts webpage if noncompliance with 02T 0305(1) or (a;), see Section. X of this application Does the project cotaaply vvith separation. requirements farttls" (5t} feet of separation) See the Division's draft separation requirements for situations where separation cannot be meet • No variance is required if the alternative design criteria specified is utilized in design and constrttetion r As built documents should reference the location of areas effected Does the project comply with. setbacks finned in the les per • This would include Trout Buffered Streams per N Af"2B.0202 4. Does the project require coy=erage°authorizatio individual permits or 401 Water C)ttality C`eatit • Information can be obtained front the:401 5. Does prruject comply vitla Per 15.A NCAC 02T.0105(c)(ta}, direct) been. applied for, or have been obtained. Issuance or this permit is contingent on issu sedimentation control plans, srorrauwater management plans, etc.). under a 4 tia.ans'l) 11 Pe Nationwide or in 05i cAr t additi 0200`. cations U No applications are bt:ing. prepared, have ce of dependent permits (;erosion. and Does this project include aany°server catallea tton litres that are deemed "high -priority'?"" Per 15A NCAC 02'T,0402, ")ugh -priority uc ter" taacatts t`any= aerial sewer, sewer contacting su.rtace positioned parallel to st.rea.mbanks that is subject to erosion that undermines or deteriorates the sewer. ® Yes If yes, include an attachment with details for each lin N/A siphon, or sewer ,and. loca High priority. shall be inspected by the permittee or its representative at least once every six -months and ins.ectrons documented per 15A NCAC 02T.0403(a)(5) or thepernritec's individual System -Wide Collection permit, FORM: FTA 04-16 Page 4 of 5 X, CRTIF'ICATIONS: 1. Does the submitted system comply with ISA NCAC 02T, the Mininturtt Design Criteria for the Permitting cj mop Stab its and Poke Mains (latest version), and the Gravity Sewer Min itatttttt Design Criieria.(Iatest version) as applicable? Yes D No lfNo, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Flist Track Application and supporting documents. 2. Professional Engineer's Certification: his applicati Professional engineer's rtatne from Application has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Caratinsr Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(b): 1, .✓1,41S0"n/ % . 47/LScNi gi% _ZA/ t-t I/V lrrft-A/ (Signature Authority's name & tie from Application Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of (his application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,. injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of This permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes I43-215.6r and 143-2.15,68., any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04-16 Page 5 of 5 Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: City of Salisbury Project Name for which flow is being requested: Crane Creek LS & FM Upgrade More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for al! pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Salisbury - Rowan WWTP ( Town Creek Train ) b. WWTP Facility Permit #: NC0023884 All flows are in MGD c. WWTP facility's permitted flow 5.000 d. Estimated obligated flow not yet tributary to the WWTP 0.337 e. WWTP facility's actual avg. flow 2.089 f. Total flow for this specific request 0.000 g. Total actual and obligated flows to the facility 2.427 h. Percent of permitted flow used 48% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and Pump Station (Name or Number) Finn Capacity, * MGD (A) Design Average Daily Flow** (Firm / pf), MGD Approx. Current Avg. Daily Flow, MGD (B) (C) Obligated, Not Yet Tributary Daily Flow, MGD the WWTP: (D)=(B+C) (E)=(A-D) Total Current Flow Plus Obligated Available Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. *% Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. xxx A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 4. Downstream Facility Name (Sewer): Salisbury - Rowan Downstream Permit Number: WQCS00019 Page 1 of 6 FTSR 114-1 f II. Certification Statement.: I Jeffrey Jones, PE PLS certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Sig 'vial tgnae Der e Page 2of6 Vel-4`P CM 14 U.S. DEPARTMENT OF THE INTERIOR U.A GE W DGICAL RATE,' 713/2©18 ConnectGlS Feature Report C NNECTG S WEE 11OO5TtNG 1 0" D Fore Main N'f;ov FM rC,"a°gss'efs Over E" rc Elfr Culvert Rowan2 ;tinted 1,4 d S, 2OTB See del for t7isclaare on was prep red from the Rowan County, NC Geographic hif rsttation yste 3 Rowan County has anode substantial efforts to ensure the acraaracy of nd iabelinq information contained r,n this see The inlorrprovided is a representatsoo of various City and County data sources and does not serve as a+t p Rowan County promotes and recommends the miaow -orient venfication of any information contained on this site by the user. Rowan County makes nor er asSe trnro- a„ to the fitness of the -saps for any partictita- os pose and neither Rowan County nor s;`s agents Of errp,oy ww steal! be Irahale for any claim have resulted Horn any use thereof httpsl'rowan2,connectgis.conor/DownloadFile ashxOi= ags_rnape15fbe8f440d4f72b2fad83569027bcax.htn&t=print 111 GROUT SEAL CASING, TYP. BOTH ENDS #4 BARS 0 6" O.C. EA. WAY, EACH FACE, TYP. 5' MIN. FROM T.O.B, TYP. - 3' MIN FROM MAXIMUM PIPE SPAN. SEE CASING PIPE TABLE — CLASS 1 RIP -RAP SLOPE PROTECTION, TYP. DO NOT PLACE IN CHANNEL BOTTOM BOTTOM OF CREEK CONTRACTOR SHALL NOT DISTURB CREEK CHANNEL BOTTOM ALLOWABLE SPANS FOR STEEL CASING PIPE CARRIER PIPE, DIP DIAMETER (IN.) CASING PIPE, STEEL DIAMETER (IN.) MINIMUM CASING PIPE WALL THICKNESS (IN.) • ALLOWABLE SPAN (FT.) 6 14 0.375 4 8 16 0.375 45 10 18 0.375 50 12 20 0.375 50 14 24 0.375 55 16 26 0.375 55 18 30 0.375 60 20 32 0.375 60 24 36 0.4375 65 30 42 0.4375 65 36 48 0.500 65 42 56 0.500 65 STEEL CASING PIPE (WELD ALL JOINTS) Q CREEK CHANNEL 1.4 4' MIN., TYP. 4"x3/8" S.S. STRAPS W/ (2) 3/4" 0 S.S. ANCHOR BOLTS EACH SIDE, TYP. DIP CARRIER PIPE WITH RESTRAINED JOINT FITTINGS BETWEEN MANHOLES CONCRETE CASING SUPPORT (4'x4'x6'), TYP. CONTRACTOR SHALL INSTALL ALL REQUIRED SEDIMENT AND EROSION CONTROL MEASURES AS REQUIRED TO PREVENT MATERIALS FROM ENTERING STREAM CHANNEL NOTES: 1. STEEL PIPE SHALL BE EITHER SPIRAL WELDED OR SMOOTH WALL SEAMLESS WITH A MINIMUM YIELD STRENGTH OF 35,000 PSI. COAT EXTERIOR OF CASING PIPE W/ COAL TAR EPDXY (MIN. 16 MILS) 2. DUCTILE IRON PIPE SHALL BE SUPPORTED WITH TWO SPIDERS AT EVERY JOINT WITHIN THE CASING PIPE USING APPROVED PIPE ALIGNMENT GUIDE. ALL JOINTS SHALL BE RESTRAINED JOINT. Detail - Aerial Pipe Crossing SRU1701 - Crane Creek PS and FM Upgrade Salisbury -Rowan Utilities H1GHFILL INFRASTRUCTURE ENGINEERING, P.C. HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. August 2, 2018 NC L7ivision of Water Resources Water Quality Section 610 East Center Avenue, Suite 301 Mooresville, NC 28115 RE: Application Submittal Crane Creek Lift Station and Force Main Upgrade I11GLIFILL Project No,: SRU1701 Dear Reviewer: 301 North Man Street, Suite 2433 Winston-Salem, North Carolina 27101 Te@ 336-701-2910 NC Fenn License No, C-2586 The Crane Creek Lift Station is located on the eastern side ofl3ringle Ferry Road, just south of the intersection with McCanless Road in Rowan County. 'Elie existing system configuration consists of a. triplex lift station and adjacent valve vault. which is capable of accommodating a fourth pump. Salisbury - Rowan Utilities (SRU) is proposing to expand the Crane Creek Lift Station and Force Main to increase system capacity and operational redundancy. There are three pumps currently installed in the existing +vet well, and a fourth pump will be added as part of this project. The lift station wet well will be reconfigured to operate as two duplex pumping systems a itla parallel force mains. Each pair of pumps will consist of 800 GPM and 1..400 (3PM pumps. Cu inch g ing I0-inch ductile iron force main conveys flow front the Iift station to <trt ex ocated along McCanless Road. A new parallel l 0-inch ductile iron force main (approximately 3,f} tl linear feet) will be installed to increase the capacity of the pump station, as well as provide increased system redundancy. Approximately 253 linear feet of existing 1.2-inch gravity sewer will he upsized to 16-inch ductile iron pipe to increase hydraulic capacity of the receiving sewer for peak pumping rates. There will he two stream crossings in the pro ec't area. The new 10-inch force main near the int of L3ringle Ferry Road and McCanless Road will cross an intermittent stream; however, the new main will be constructed of -ductile iron pipe and will be installed in the existing road shoulder a culvert (the stream runs through an existing 60-inch culvert under McCanless Road). The other cr will require replacement of an existing I2-inch gravity sewer (aerial pipe) that crosses Town Cree replacement pipe will be an aerial 16-inch ductile iron gravity sewer installed within a new steel casing pipe (aerial). To meet the Alternative Design Criteria for Minimum Separations, the use of duc pipe at the stream crossings (constructed to water main standards) is proposed as part of this pro No additional flow will be generated from this project. The Crane Creek Lift Station is not covered under existing individual permit, but it is included of Salisbury's System -wide Collections Sys ern permit, W CS00019. In summary, this project consists of: Approximately= 3,050 linear feet new 10-inch ductile iron force nlain, Approximate 53 linear feet of existing 1: psized to i6-inch ductile 'iron. Engineering rs our pro ession. Sert rre is our p©ssIon. NC Division of Water Resources August 2, 2018 Page 2 Pump station site improaements, which include adding a fourth pump, relocating the existing 24- inch gravity sewer (within the limits of the lift station site), installation of a new 8ix8" junction box and wastewater screen: installation of bao bypass pumping coimections (one for each force main), a new ‘N ater sera Reline and yard hydrant (both by SRU), and installation of a new motorized entrance gate. Along with an application fee check in the amount of $48000. please find enclosed two copies each of the following documents for re a lew and approa al: • Coa ex 1,etter Fast -Track Application Form Flow Tracking/Acceptance Form USGS 'FOPO Nlap Street Level Map Attachment of Aerial Pipe Crossing Please contact rile at 336-701-2910 or aabratriletria hiepe.com if you have any questions or require additional project information. Respectfittly:Submitte,d, lfIGHHLLINERASIRUCTURE :ENGINEERING, :RC. Ves Brainlett, PL Project Manager cc, Jason liVilson, PE — Engineering Mantiger. Salisbury -Rowan utilities