HomeMy WebLinkAboutSW7080517_HISTORICAL FILE_20210708STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYM M DD ROY COOPER Governor ELIZABETH S. BISER Secretary BRIAN WRENN Director NORTH CAROLINA Environmental Quality July 8, 2021 Town of Kill Devil Hills Attention: Steve Albright, Public Services Director P.O. Box 1719 Kill Devil Hills, NC 27948 Subject: Stormwater Permit Rescission Stormwater Management Permit SV 7080517 Proposed Kill Devil Hills Satellite Fire Station Dare County Dear Mr. Albright: The Division of Energy, Mineral, and Land Resources received your e-mail of July 6, 2021, stating that you did not wish to renew stormwater permit SV 7080517. It is our understanding that this facility was never built. Based on this information we are hereby rescinding permit SV 7080517. If you have questions, please feel free to contact me or Roger Thorpe at (252) 946- 6481. Sincerely, Samir Dumpor, P.E. Regional Engineering Supervisor II North Carolina Department of Environmental Quality ' Division of Energy, Mineral and Land Resources �S) Washington Regional Offire 1 943 Washington Square Nail I Washington. North Carolina 27889 29294h6481 Thorpe, Roger From: Albright, Steve <Steve@ kdhnc.com > Sent: Tuesday, July 6, 2021 11:07 AM To: Thorpe, Roger Cc: Diaz, Debora P; meredith@kdhnc.com Subject: [External] Town of Kill Devil Hills Satellite Fire Station - Permit #SW7080517 CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good Morning Roger, The Town of Kill Devil Hills has received the permit renewal request for the above referenced storm water permit. The Town decided not to pursue the satellite fire station at this location based on cost and staffing issues. The site remains vacant and undeveloped. No land disturbing activity was ever undertaken at this site. With no improvements, we see no need to renew the permit at this time. Please let us know if we need to take any additional action. Sincerely, Steve Albriaht Public Services Director Town of Kill Devil Hills 107 Town Hall Drive PO Box 1719 Kill Devil Hills, NC 27948 Office - 252-480-4086 Fax - 252-441-6136 www.kdhnc.com ROY COOPER Governor JOHN NICHOLSON Interim Secretary BRIAN WRENN Director NORTH CAROLINA Environmental Quality June 29. 2021 Town of Kill Devil Hills Attention: Deborah Diaz, Town Manager 102 Town Hall Drive Kill Devil Hills, NC 27948 Subject: Stormwater Permit Renewal Stormwater Management Permit SW7080517 Kill Devil Hills Satellite Fire Station Dare County Dear Ms. Diaz: 1Va A 6 A Division of Energy, Mineral, and Land Resources file review has determined that Stormwater Permit SV 7080517 for a stormwater treatment system consisting of four infiltration basins to serve a proposed Satellite Fire Station to be located at 2011 South Croatan Hwy in Kill Devil Hills, NC expires on December 30, 2021. This is a reminder that permit renewal applications are due 180 days prior to expiration. We do not have a record of receiving a renewal application. If you wish to maintain this permit, please submit a completed permit renewal application along with a $505.00 fee for permit renewal. Permit application forms for renewal can be found on our website at: https://deq.nc.gov/about/divisions/energy- mineral-and-land-resources/stormwater/stormwater-program/post-construction-2. North Carolina General Statutes and the Coastal Stormwater rules require that this property be covered under a stormwater permit if the project is built. If you do not plan on building this project and you wish to rescind the permit, please let us know. If you have questions, please feel free to contact me at (252) 948-3923. 1 will be glad to discuss this by phone or meet with you. If you would like, I can e-mail you a copy of the application forms. You can request a copy by e-mailing me at roger. thorpe(a.ncdenr.gov. Sincerely, Roger K. Thorpe Environmental Engineer D_EQ'P North Carolina Department of Environmental Quality I Division of Energy. Mineral and Land Resources e .N Washington Regional Office 1 943 Washington Square Mall I Washington, North Carolina 27889 �+� /� 2829466481 _ I= ENGINEERS_0�ARCHITECTS, •__P_LANNERS. s #vc " 449 McLaws Circle, Williamsburg, VA 23185 • P. O Box 3505, Williamsburg, VA 23187 Phone 757.253 0673 • Norfolk -Virginia Beach 757 874 5015 • Fax (757) 253-2319 E-Mail: wilhamsburg@dlginc com • Web. www.djgmc.com September 10, 2008 Mr. Samir Dumper, PE Environmental Engineer NC Dept of Environmental and Natural Resources Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Re: Town of Kill Devil Hills - Satellite Fire Station t r i� ILk;ti$ Dare County StormwaterReview -SW7080517 D eUll-W/n1,r R00 DJG# 2070170 o 0�1 Dear Mr. Dumpor: In response to our telephone conversation on Aug 21, 2008, we have edited the application and plans as necessary and provide the following responses: �1. Stream Classification S13 and Stream Index Number 99-(7) added to page 2 of the Stormwater Application. 2. Infiltration "french Detail: Detail has been edited to more clearly reflect the sloped sides of the infiltration trenches proposed. See drawing sheet C2.1 for detail and sheet C7.1 for trench profiles. 3. Simple Method: Recalculation of volume using inch units instead of decimal on page 26-27. 4. Infiltration quantity removed from provided detention calculation, see page 33-34. 5. The required vegetated filter of at least 30 feet added to trench #4. Please contact me if you have any questions or concerns. Sincerely, Milissa England Land Development ME:sv DJG, INC. P.O. Box 3505 449 McLaws Circle WILLIAMSBURG, VIRGINIA 23187 (757) 253.0673 or 874.5015 FAX (757) 253-2319 TO G�asGu i�fon i�eg �ow�l o-�r� 3 sGt iy�, t�t/t Saure Mall Gt�gS�.11�G�n� NG �7��9 WE ARE SENDING YOU ❑ Shop drawings ❑ Copy of letter ❑ Attached ❑ Under separate cover via ❑ Prints ❑ Plans ❑ Change order ❑ dCE44ER @I F 4 L�l�f�n 17044L1(� DATE q_ Z31ng (/ JOB No Z7D/�� ATTENTIO �I�fr. i E RE' �r tA�7D�1 8 /- following items: ❑ Samples ❑ Specifications COPIES DATE NO DESCRIPTION 2LZ sAeet C-7,J SEP .Z = L THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE REMARKS ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US COPY TO SIGNED N enclosures are not as noted, k/ndly notify us at once. DJG, INC. P.O. Box 3505 449 McLaws Circle WILLIAMSBURG, VIRGINIA 23187 dL "u"N' 3 OG= 4 �&M@W044LQd (757) 253-0673 or 874.5015 FAX (757)�2+53-2319 D / TO ���t. 0r � U d l 14114r l Weg. Wash ri'afjh Pew"' C 0*6,,o 1945hlk� j M� �7889 WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ DATE // JOB NO Z0 D 7o ATTENTION PE RE: 1, aAfIh e Fir 708 0 the following items: ❑ Samples ❑ Specifications pig A" "PiWiz � ©��M /j�_ M��M - THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE REMARKS ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US COPY TO If enclosures are not as noted, kindly notify us at once. ;� r _ _ -. _ � - - � .. _ .. 1 .. ..- .. . ;� ` ,� � � � _ _ �.. � �� t J\ � _ � � .... �. 2 ' .'�, . I r �� .J � � � i � _ • r - � � _ r 4. • � _ , ♦ r� _ J DJG, INC. P.O. Box 3505 449 McLaws Circle WILLIAMSBURG, VIRGINIA 23187 (757) 253-0673 or 874-5015 FAX (757) 253.2319 TO N6 24 t• of Ehy d A/atuYal R�5of Env. Q�al yral l� W�hi�to�l��i o�/��ce q¢3 Wgsh�• tan S uare ,�lal/ Wash!'tan) WG 78,?q WE ARE SENDING YOU [)(Attached ❑ Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ DATE /t_ /l/L�' —08 JOB NO. 2070 70 ATTENTION /gyp U RE: S soleffite, Flrestatwn SIAI f70,9osi following items: ❑ Samples ❑ Specifications THESE ARE TRANSMITTED as checked below ❑ ❑ ❑ ❑ ❑ REMARKS For approval For your use As requested For review and comment FORBIDS DUE ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ ❑ ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints PRINTS RETURNED AFTER LOAN TO US AUG 0 n AAMOrl vvrlr% COPY TO SIGNED /f enclosures are not as noted, kindly notify us at once. DJG, INC. P.O. Box 3505 449 McLaws Circle WILLIAMSBURG, VIRGINIA 23187 LIETTEn @IF 4 �&K@WHctT` RAIL (757) 253-0673 or 874.5015 FAX (757) 253.2319 DATE ✓ /&- O JOB NO�O/ 7D ATTENTION r O RE. / I / j,...//� v / / f / I cSt f7On - ilrt3 �%+'s cif tkMAY 9009 WE ARE SENDING YOU 5d' Attached ❑ Under separate cover via Dllurt 1- ARO the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order ❑ DESCRIPTION THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ FORBIDS DUE REMARKS ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections ❑ ❑ ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints PRINTS RETURNED AFTER LOAN TO US COPY TO SIGNED: If enclosures are not as noted, kindly notify us at once. 0 r 1 s . ENGINEERS-o-AR_CHISEC_T_S-*—P_LANNERS .__. INC. 449 McLaws Circle, Williamsburg, VA 23185 P. O. Box 3505, Williamsburg, VA 23187 Phone 757.253.0673 • Norfolk -Virginia Beach: 757 874,5015 • Fax (757) 253-2319 E-Mail: williamsburg@dlgmccom • Web. www.djginc.com August 6, 2008 Mr. Samir Dumper, PE Environmental Engineer NC Dept of Environmental and Natural Resources �F Washington Regional Office `" ' 7FM6V 943 Washington Square Mall Washington, NC 27889 AUG - 7 2008 Re: Town of Kill Devil Hills — Satellite Fire Station.r`1i'� Dare County Stormwater Review — SW7080517 DJG# 2070170 Dear Mr. Dumpor: In response to the comments forwarded to DJG. Inc. on July 9, 2008, we have edited the application and plans as necessary and provide the following responses: /1. Stream Classification SB and Stream Index Number 99-(7) added to page 2 of the Stormwater Application. `` 2. No wetlands existing on site. See drawing sheet C2.1, Note #6 for notation. 3. Infiltration basin detail added to drawing sheet C2.1. The plan view drawing and the detail contain all major dimensions. The total runoff volume captured by each basin are as follows Basin 41 = 0.07 ac-in Basin 42 = 0.07 ac-in Basin #3 = 0.30 ac-in Basin #4 = 0.96 ac-in Total = 1.4 ac-in This project does not exceed the maximum 2 acre -inch per inlet requirement. This information can be found on each infiltration basin supplement, page 2. Calculation information is on page 35 of the Drainage Calculations. 4. Simple method calculations for the first inch of stormwater runoff can be found on page 32-34 of the Drainage Calculations. Simple method calculations reveal the first inch runoff equals 479.74 cu. feet. The site provides 7,698 cu. feet of detention and infiltration. (Ezz Se- 2 Mr. Dumper August 6, 2008 Page 2 of 2 V'. See attached soils report. Seasonal High Water Table information appears on page six of report. Report states SH WT occurs approximately 4.5 feet below the existing site grade. Drainage 44 and 95 have been combined into 1 infiltration basin supplement. I/ 7. SHWT elevation revised on each supplement. 8. Basin supplements revised to include storage volume. See page 31 of drainage calculations for total storage required and provided. 9. Basin supplements revised to include basin bottoms covered with 4 inches of clean sand. See drawing sheet C2.1 for detail. 10. Grading has been revised to incorporate a depression (sump) at the outflow of each rip rap Swale. This will act as a pre-treatment device. See sheet C2.1. ✓1. Seeding specification document add the sheet C4.1. t/ 12. Stamped plans and calculations included in this submission. �t/ 13. All documents revised. 14. Comment noted. Please contact me if you have any questions or concerns. Sincerely, Milissa England Land Development ME:sv T47 r` j - Y July 9, 2008 Town of Kill Devil Hills Attn.: Shawn -Murphy, Assistant Town Manager P.O. Box,1719 Kill Devil Hills, NC 27948 Michael P Eanlc�, Co,cnwr William G Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H Sullins, Director Division ofWater Quality Subject:: Stormwater Review SW7080517 Town of Kill Devil Hills - Satellite Fire Station Dare County Dear Mr. Murphy: This office received a Coastal Stormwater permit application and plans for the subject project on May 21, 2008. A preliminary review of your project indicates that before a State Stormwater permit can be issued the following additional information is needed: Vic' Revise page 2 of 4 of the Stormwater Application to include the Stream Classification & / Stream Index number. 2. As per the Stromwater Application check list, the wetlands on site should be delineated, or a note written on plans that none exist. 3. Provide the Infiltration Basin detail (profile and plan view with all major dimensions). Pay particular attention to BMP Manual requirements for Infiltration Basins (Chapter 16, Major Design Elements), like bypass and vegetative filter etc. The 2 acre -inches maximum runoff requirement (in BMP Manual) is per inlet requirement. 4. Your basins appear to be sized per local requirement of 4.3 inches. The State Stormwater Program however has requires first inch of Stormwater (for non- SA waters) runoff to be stored and infiltrated within 5 days. To calculate the necessary volume, please use the Simple Method as outlined in the new Stormwater BMP Manual. If you can provide the / double storage, that the bypass requirements may be waived. 1/ 5. The Soils Report has to include the soil borings log (auger borings) at the location of proposed Infiltration Basins and should have information about Seasonal High Water Table elevation (SHWT). Please be reminded that the bottom of infiltration basin should be plsccc at least two feet above the SHWT. 6, It appears that Drainage areas 4 and 5 are draining in same infiltration basin, hence one Infiltration Basin Supplement will be sufficient for these drainage areas. 7. Revise the Infiltration Basin Supplements to include the SHWT elevation (not the depth). 8. Revise the Infiltration Basin Supplements to include the Storage Volume for Non -SR waters 2 (required and provided). 9. Revise the Infiltration Basin Supplements to show that the bottom of infiltration basin should 2 be covered with 4 inches of clean sand. 10. The Pretreatment device for infiltration basins is required. Simple sump within the catch basin would be considered as a pretreatment. 11. Provide the Permanent and Temporary Seeding specs on plans. (�2. The Plans and the Calculations are not signed and sealed. Revise. 1,3. Please revise all the other documents to reflect these changes. 4. Provide 2 sets of siqned and sealed plan sheets and calculations. North Carolina Division of Water Quality Internet w ncwaterqualitv.ore One 943 Washington Square Mall Phone (252) 946-6481 NorthCarolina Washington, NC 27889 Fax (252) 946-9215 Naturally An Equal Opportunity/Affirmative Action Employer — 50% Recycled110 % Post Consumer Paper `/ The above requested information must be received in this office prior to August 10, 2008 or your application will be returned as incomplete. The return of this project will necessitate resubmittal of all required items including the application fee. If you need additional time to submit the required infnrmation please mail or fax your request for time extension to me at the Letterhead address and _:'e t,ie application number on the request. The request must include justification for the amount of aaditional time needed. The request will only be granted for justifiable delays that are unforeseen and beyond the owner or consultant's control. You should also be aware that the Stormwater Rules require that the permit be issued prior to any development activity. Construction without a permit is a violation of 15A NCAC 21-1.1000 and North Carolina General Statute 143-215.1 and may result in civil penalties of up to $25,000 per day. Please reference the Stormwater Project Number above on all correspondence. If you have questions, please feel free to contact me at (252) 948-3959. �Sincerely, r 1 Samir Dumpor, PE Environmental Engineer Washington Regional Office cc: V Washington Regional Office Milissa England, DJG, Inc., 449 McLaws Circle, Williamsburg, VA 23185 4 .F K