Loading...
HomeMy WebLinkAboutWM0501460_More Information (Received)_20211118S&ME, Inc. | 3201 Spring Forest Road | Raleigh, NC 27616 | p 919.872.2660 | www.smeinc.com November 12, 2021 Raleigh Regional Office NCDEQ-DWR 3800 Barrett Drive Raleigh, NC 27609 Attention: Mr. Rick Bolich via email: rick.bolich@ncdenr.gov Section Chief Reference: Well Permit Application Welcome Venture Park - 1225 Hamlin Rd, Durham, NC Durham, Durham County, North Carolina S&ME Project No. 218154 Dear Mr. Bolich: On behalf of our client, Welcome Real Estate Services, LLC, I am submitting the enclosed Well Permit Application (Form GW-22MR) to construct 14 monitor wells at the Welcome Venture Park in Durham, NC. Enclosed are the following: Application for Permit to Construct a Monitoring or Recovery Well System (Form GW-22MR) Scaled map as required by 15A NCAC 02C .0105(f)(5) o Figure 1 – Proposed Monitor Well Locations Well construction details as required by 15A NCAC 02C .0105(f)(7) o Figure 2 - Proposed Well Construction Diagram o Table 1 - Proposed Drilling & Well Construction Details If you have any questions, or need additional information, to process this request for a Well Construction Permit, please contact me by email at swatts@smeinc.com, or by phone at 919-801-4920 (M). Sincerely, S&ME, Inc. Samuel P. Watts, PG Senior Geologist NC Licensed Geologist No. 1806 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 11/03/2021 2. County: Durham FOR OFFICE USE ONLY PERMIT NO, ISSUED DATE 3. What type of well are you applying for? (monitoring or recovery): Monitoring 4. Applicant: Welcome Wilson, Jr./Ted Kakambouras (Welcome Real Estate Services, LLC) Telephone: 832-343-5175 Applicant's Mailing Address: 5858 Westhelmer. Suite 800, Houston, Texas 77057 Applicant's Email Address (if available): tkakambouras(cr�welcomegroup.com 5. Contact Person (If different than Applicant): Sam Watts (S&ME Inc.) Telephone: 919-801-4920 Contact Person's Mailing Address: 3201 Spdnq Forest Rd, Raleigh, NC 27616 Contact Person's Email Address (if available): swatts(ilsmeinc.com 6. Property Owner (if different than Applicant): John Reece (Eno Development Partners, LLC) Telephone: 336-793-0890 Property Owner's Mailing Address: 751 West Fourth Street, STE 310, Winston-Salem, NC 27101 Property Owner's Email Address (if available): lohnacommercialrealtvnc.com 7. Property Physical Address (Including PIN Number) 1420 Old Oxford Road, 1225 Hamlin Road, 1507 Hamlin Road and 1539 Hamlin Road (PINs: 0833-02-89-5258, 0844-01-10-2331, 0843-01-09-6498, 0833-02-99-6163) City Durham County Durham Zip Code 27704 8. Reason for Well(s): Assessment of suspected groundwater contamination (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: New development. Possible NC Brownfields site. (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). Mitsubishi Electronics/ NONCD0002085 and Beckman -Durham -Sandefur/ NONCD0002410370 11. Type of contaminants being monitored or recovered: Petroleum, VOCs, Solvents (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? 53 existing monitor &.inlection wells are installed to monitodremediate the Mitsubishi Electronic site. Unknown number of wells installed for the Beckman -Durham -Sandefur site. Existing Monitoring or Recovery Well Construction Permit No(s).: Unknown 13. Distance from proposed well(s) to nearest known waste or pollution source (In feet): 1,300 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No If yes, give distance(s): 15. Well Contractor: Chris Schappell (M&W Drilling, LLC) Certification No.: 2332-A Well Contractor Address: 8321 Oak Ridge Hwy Knoxville TN 37931 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals d. Sand/gravel pack intervals g. Well head completion details Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 5 3. Number of wells to be constructed in bedrock: 10 5. How will the well(s) be secured? Lockable steel casing (stick-up) with concrete Dad. 6. Estimated beginning construction date: 11/29/2021 4. Total Number of wells to be constructed: 15 7. Estimated construction completion date: 12/03/2021 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as Identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well s) will be constructed in accordance with approved specifications and conditions of thls Well Construction Permit as reg Iated uncle t Well Construction Standards (Title 15A of the North Carolina Administrative Code, bcha2C) an• accepts full responsibility for compliance with these rules P ReS Att4 C150 Signature of Applicant or *Agent Title of Applicant or *Agent e\ 6A6 1 .°\IN66 Printed name of Applicant or *Agent *If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is oyv by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outli ei-1 his Well Co t ion Permit application and that it shall be the responsibility of the applicant to ensure that the well(s)conf rm t a W Constr ction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). //A,- Si9nature of " roperty Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) rolobb DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796.7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 3 GW-22MR Rev, 3-1-2016 mvrl nIntterl h„ Ihecte 1n_9a_91171 n Path• T\GFCAPrniertc\7n71\71R15d The WeIrnme frnun Fnn uentnre Park nlirham NI V;IC\Prnnnceri Fnvirnnmental A Former Mitsubishi Electric Site KBI Biopharma & Biomeriux Railroad Groundwater VOC Contamination REFERENCE: GIS BASE LAYERS WERE OBTAINED FROM THE 2017 NC ONEMAP ORTHOIMAGERY BASEMAP. THIS MAP IS FOR INFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED. THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. 2011 Hamlin Road 3333 Industrial Drive Ct rrent Durham Public School Child Nutrition Center 1817 Hamlin Road 1714 Hamlin Road Beckman -Durham - Sandefur Site (NONCD0002410370) LEGEND Drinking Water Wells Proposed Monitor Well Location Existing Monitor Well Location Stream Subject Property SCALE: 1 "=400' DATE: 11-11-21 PROJECT NUMBER 218154 FIGURE NO. 1 J Well ID Typical S&ME Staff Drill Rig Water Level at TOB (0.01 ft- BTOC)Land Surface Elev. (0.01 ft) Depth to Water (0.01 ft- BTOC) Stickup Height - 2.0 ft - Steel Protective Casing - Expandable Locking Cap Concrete Pad - 0.0 ft 0.0 to 15.0 Neat Cement Grout 15.0 to 25.0 Top of Seal - 11.0 0.1 ft-bgs Bentonite Slurry Top of Filter Pack - 13.0 0.1 ft-bgs 2-ft Minimum Sand Pack 0.0 to 11.0 Top of Screen - 15.0 0.1 ft-bgs 2-ft Minimum Above Screen 0.010-inch Slotted Well Screen 11.0 to 13.0 Screened Interval -10.0 0.1 ft-bgs No. 2 Filter Sand Pack 13.0 to 25.0 Bottom of Screen - 25.0 0.1 ft-bgs Bottom of Filter Pack - 25.0 0.1 ft-bgs Cave In - 0.0 0.1 ft-bgs Total Boring Depth - 25.0 0.1 ft-bgs Notes: Minimum 4-1/4-Inch Diameter Borehole Minimum 2-Inch Diameter PVC Well Screen & Riser Form Revision Date: County Drilling Contractor Drilling Method Well Type / Use City Durham Durham License Number Well Permit Number 25.0 Northing (0.1 ft)Date/Time Total Well Depth (0.1 ft-bgs)Easting (0.1 ft)Date/Time Installation Date Project Name Welcome Venture Park Project Number 218154 FIGURE 2 - PROPOSED WELL CONSTRUCTION DIAGRAM Filter Pack Interval (0.1 ft-bgs) Screen Interval (0.1 ft-bgs) Grout Type #2 Silica Sand Benseal® granular Pad Type Protective Casing Casing Material Depth Below Ground Surface (ft-bgs) 2' x 2' Concrete 2" x 2" Steel Seal Type 2-in Sch 40 PVC (0.010) Quik-Grout® 2-in Sch 40 PVC Casing Interval (0.1 ft-bgs) Screen Type Borehole Diameter (1 in) For lithologic information see attached boring log BTOC - Below Top of Casing 9/1/17 2:10 PM TBD - To Be Determined Seal Interval (0.1 ft-bgs) Filter Pack Grout Interval (0.1 ft-bgs) Development Volume (gal) Development Table 1 - Proposed Drilling & Well Construction Details Welcome Venture Park Hamlin & Oxford Road, Durham, NC S&ME Project No. 218154 Prepared by S.Watts -- 11/11/21 Well ID Est PWR Est Rock Est DTW Screened Interval Est Total Depth MW-1 5 6 25 20 to 30 30 MW-2 6 10 25 20 to 30 30 MW-3 19 20 30 25 to 35 35 MW-4 ----20 15 to 25 25 MW-5 10 18 25 20 to 30 30 MW-6 12 18 25 20 to 30 30 MW-7 10 18 25 20 to 30 30 MW-8 10 18 25 20 to 30 30 MW-9 6 18 25 20 to 30 30 MW-10 10 15 30 25 to 35 35 MW-11 10 20 25 20 to 30 30 MW-12 5 20 15 10 to 20 20 MW-13 14 20 12 7 to 17 17 MW-14 8 20 10 5 to 15 15 Total:387 Notes: Depths are estimated feet below ground surface. (ft-bgs) Assumes 10-foot long screened interval @ each well. PWR = parttially weathered rock DTW = depth to water