HomeMy WebLinkAboutWM0501460_More Information (Received)_20211118S&ME, Inc. | 3201 Spring Forest Road | Raleigh, NC 27616 | p 919.872.2660 | www.smeinc.com
November 12, 2021
Raleigh Regional Office
NCDEQ-DWR
3800 Barrett Drive
Raleigh, NC 27609
Attention: Mr. Rick Bolich via email: rick.bolich@ncdenr.gov
Section Chief
Reference: Well Permit Application
Welcome Venture Park - 1225 Hamlin Rd, Durham, NC
Durham, Durham County, North Carolina
S&ME Project No. 218154
Dear Mr. Bolich:
On behalf of our client, Welcome Real Estate Services, LLC, I am submitting the enclosed Well Permit Application
(Form GW-22MR) to construct 14 monitor wells at the Welcome Venture Park in Durham, NC. Enclosed are the
following:
Application for Permit to Construct a Monitoring or Recovery Well System (Form GW-22MR)
Scaled map as required by 15A NCAC 02C .0105(f)(5)
o Figure 1 – Proposed Monitor Well Locations
Well construction details as required by 15A NCAC 02C .0105(f)(7)
o Figure 2 - Proposed Well Construction Diagram
o Table 1 - Proposed Drilling & Well Construction Details
If you have any questions, or need additional information, to process this request for a Well Construction Permit,
please contact me by email at swatts@smeinc.com, or by phone at 919-801-4920 (M).
Sincerely,
S&ME, Inc.
Samuel P. Watts, PG
Senior Geologist
NC Licensed Geologist No. 1806
NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES
APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM
PLEASE TYPE OR PRINT CLEARLY
In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto,
application is hereby made for a permit to construct monitoring or recovery wells.
1. Date: 11/03/2021
2. County: Durham
FOR OFFICE USE ONLY
PERMIT NO, ISSUED DATE
3. What type of well are you applying for? (monitoring or recovery):
Monitoring
4. Applicant: Welcome Wilson, Jr./Ted Kakambouras (Welcome Real Estate Services, LLC) Telephone: 832-343-5175
Applicant's Mailing Address: 5858 Westhelmer. Suite 800, Houston, Texas 77057
Applicant's Email Address (if available): tkakambouras(cr�welcomegroup.com
5. Contact Person (If different than Applicant): Sam Watts (S&ME Inc.) Telephone: 919-801-4920
Contact Person's Mailing Address: 3201 Spdnq Forest Rd, Raleigh, NC 27616
Contact Person's Email Address (if available): swatts(ilsmeinc.com
6. Property Owner (if different than Applicant): John Reece (Eno Development Partners, LLC) Telephone: 336-793-0890
Property Owner's Mailing Address: 751 West Fourth Street, STE 310, Winston-Salem, NC 27101
Property Owner's Email Address (if available): lohnacommercialrealtvnc.com
7. Property Physical Address (Including PIN Number) 1420 Old Oxford Road, 1225 Hamlin Road, 1507 Hamlin Road and
1539 Hamlin Road (PINs: 0833-02-89-5258, 0844-01-10-2331, 0843-01-09-6498, 0833-02-99-6163)
City Durham County Durham Zip Code 27704
8. Reason for Well(s): Assessment of suspected groundwater contamination
(ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.)
9. Type of facility or site for which the well(s) is(are) needed: New development. Possible NC Brownfields site.
(ex: non -discharge facility, waste disposal site, landfill, UST, etc.)
10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s).
Mitsubishi Electronics/ NONCD0002085 and Beckman -Durham -Sandefur/ NONCD0002410370
11. Type of contaminants being monitored or recovered: Petroleum, VOCs, Solvents
(ex: organics, nutrients, heavy metals, etc.)
12. Are there any existing wells associated with the proposed well(s)? If yes, how many? 53 existing monitor &.inlection wells are
installed to monitodremediate the Mitsubishi Electronic site. Unknown number of wells installed for the Beckman -Durham -Sandefur site.
Existing Monitoring or Recovery Well Construction Permit No(s).: Unknown
13. Distance from proposed well(s) to nearest known waste or pollution source (In feet): 1,300
14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No
If yes, give distance(s):
15. Well Contractor: Chris Schappell (M&W Drilling, LLC) Certification No.: 2332-A
Well Contractor Address: 8321 Oak Ridge Hwy Knoxville TN 37931
PROPOSED WELL CONSTRUCTION INFORMATION
1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following:
a. Borehole and well diameter e. Type of casing material and thickness
b. Estimated well depth f. Grout horizons
c. Screen intervals
d. Sand/gravel pack intervals
g. Well head completion details
Continued on Reverse
PROPOSED WELL CONSTRUCTION INFORMATION (Continued)
2. Number of wells to be constructed in unconsolidated
material: 5
3. Number of wells to be constructed in bedrock: 10
5. How will the well(s) be secured? Lockable steel
casing (stick-up) with concrete Dad.
6. Estimated beginning construction date: 11/29/2021
4. Total Number of wells to be constructed: 15 7. Estimated construction completion date: 12/03/2021
(add answers from 2 and 3)
ADDITIONAL INFORMATION
1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following:
a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as Identified roads,
intersections, streams, or lakes within 500 feet of the proposed well or well system.
b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system.
c. The proposed well or well system.
d. Any test borings within 500 feet of proposed well or well system.
e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel
storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet
of the proposed well or well system.
SIGNATURES
The Applicant hereby agrees that the proposed well s) will be constructed in accordance with approved specifications and conditions of
thls Well Construction Permit as reg Iated uncle t Well Construction Standards (Title 15A of the North Carolina Administrative Code,
bcha2C) an• accepts full responsibility for compliance with these rules
P ReS Att4 C150
Signature of Applicant or *Agent Title of Applicant or *Agent
e\ 6A6 1 .°\IN66
Printed name of Applicant or *Agent
*If signing as Agent, attach authorization agreement stating
that you have the authority to act as the Agent.
If the property is oyv by someone other than the applicant, the property owner hereby consents to allow the applicant to construct
wells as outli ei-1 his Well Co t ion Permit application and that it shall be the responsibility of the applicant to ensure that the
well(s)conf rm t a W Constr ction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C).
//A,-
Si9nature of " roperty Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant)
rolobb
DIRECTIONS
Please send the completed application to the appropriate Division of Water Resources' Regional Office:
Asheville Regional Office
2090 U.S. Highway 70
Swannanoa, NC 28778
Phone: (828) 296-4500
Fax: (828) 299-7043
Fayetteville Regional Office
225 Green Street, Suite 714
Fayetteville, NC 28301-5094
Phone: (910) 433-3300
Fax: (910) 486-0707
Mooresville Regional Office
610 East Center Avenue
Mooresville, NC 28115
Phone: (704) 663-1699
Fax: (704) 663-6040
Raleigh Regional Office
3800 Barrett Drive
Raleigh, NC 27609
Phone: (919) 791-4200
Fax: (919) 571-4718
Washington Regional Office
943 Washington Square Mall
Washington, NC 27889
Phone: (252) 946-6481
Fax: (252) 975-3716
Wilmington Regional Office
127 Cardinal Drive Extension
Wilmington, NC 28405
Phone: (910) 796.7215
Fax: (910) 350-2004
Winston-Salem Regional Office
450 W. Hanes Mill Road
Suite 300
Winston-Salem, NC 27105
Phone: (336) 776-9800
Fax: (336) 776-9797
3
GW-22MR Rev, 3-1-2016
mvrl nIntterl h„ Ihecte 1n_9a_91171
n Path• T\GFCAPrniertc\7n71\71R15d The WeIrnme frnun Fnn uentnre Park nlirham NI V;IC\Prnnnceri Fnvirnnmental A
Former Mitsubishi
Electric Site
KBI Biopharma
& Biomeriux
Railroad
Groundwater VOC
Contamination
REFERENCE:
GIS BASE LAYERS WERE OBTAINED FROM THE 2017 NC ONEMAP ORTHOIMAGERY
BASEMAP. THIS MAP IS FOR INFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS
DISPLAYED ARE APPROXIMATED. THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION,
UNLESS STATED OTHERWISE.
2011 Hamlin Road
3333 Industrial Drive
Ct rrent Durham Public School
Child Nutrition Center
1817 Hamlin Road
1714 Hamlin Road
Beckman -Durham -
Sandefur Site
(NONCD0002410370)
LEGEND
Drinking Water Wells
Proposed Monitor Well Location
Existing Monitor Well Location
Stream
Subject Property
SCALE:
1 "=400'
DATE:
11-11-21
PROJECT NUMBER
218154
FIGURE NO.
1
J
Well ID
Typical
S&ME Staff
Drill Rig
Water Level at TOB (0.01 ft- BTOC)Land Surface Elev. (0.01 ft)
Depth to Water (0.01 ft- BTOC)
Stickup Height - 2.0 ft - Steel Protective Casing
- Expandable Locking Cap
Concrete Pad - 0.0 ft
0.0 to 15.0
Neat Cement Grout
15.0 to 25.0
Top of Seal - 11.0 0.1 ft-bgs
Bentonite Slurry
Top of Filter Pack - 13.0 0.1 ft-bgs 2-ft Minimum
Sand Pack 0.0 to 11.0
Top of Screen - 15.0 0.1 ft-bgs 2-ft Minimum Above Screen
0.010-inch Slotted Well Screen 11.0 to 13.0
Screened Interval -10.0 0.1 ft-bgs
No. 2 Filter Sand Pack
13.0 to 25.0
Bottom of Screen - 25.0 0.1 ft-bgs
Bottom of Filter Pack - 25.0 0.1 ft-bgs
Cave In - 0.0 0.1 ft-bgs
Total Boring Depth - 25.0 0.1 ft-bgs
Notes:
Minimum 4-1/4-Inch Diameter Borehole
Minimum 2-Inch Diameter PVC Well Screen & Riser
Form Revision Date:
County
Drilling Contractor
Drilling Method
Well Type / Use
City
Durham Durham
License Number
Well Permit Number
25.0
Northing (0.1 ft)Date/Time
Total Well Depth (0.1 ft-bgs)Easting (0.1 ft)Date/Time
Installation Date
Project Name
Welcome Venture Park
Project Number
218154
FIGURE 2 - PROPOSED WELL CONSTRUCTION DIAGRAM
Filter Pack Interval (0.1 ft-bgs)
Screen Interval (0.1 ft-bgs)
Grout Type
#2 Silica Sand
Benseal® granular
Pad Type
Protective Casing
Casing Material
Depth Below Ground Surface (ft-bgs)
2' x 2' Concrete
2" x 2" Steel
Seal Type
2-in Sch 40 PVC (0.010)
Quik-Grout®
2-in Sch 40 PVC
Casing Interval (0.1 ft-bgs)
Screen Type
Borehole Diameter (1 in)
For lithologic information
see attached boring log
BTOC - Below Top of Casing
9/1/17 2:10 PM
TBD - To Be Determined
Seal Interval (0.1 ft-bgs)
Filter Pack
Grout Interval (0.1 ft-bgs)
Development Volume (gal)
Development
Table 1 - Proposed Drilling & Well Construction Details
Welcome Venture Park
Hamlin & Oxford Road, Durham, NC
S&ME Project No. 218154
Prepared by S.Watts -- 11/11/21
Well ID Est PWR Est Rock Est DTW Screened Interval Est Total Depth
MW-1 5 6 25 20 to 30 30
MW-2 6 10 25 20 to 30 30
MW-3 19 20 30 25 to 35 35
MW-4 ----20 15 to 25 25
MW-5 10 18 25 20 to 30 30
MW-6 12 18 25 20 to 30 30
MW-7 10 18 25 20 to 30 30
MW-8 10 18 25 20 to 30 30
MW-9 6 18 25 20 to 30 30
MW-10 10 15 30 25 to 35 35
MW-11 10 20 25 20 to 30 30
MW-12 5 20 15 10 to 20 20
MW-13 14 20 12 7 to 17 17
MW-14 8 20 10 5 to 15 15
Total:387
Notes:
Depths are estimated feet below ground surface. (ft-bgs)
Assumes 10-foot long screened interval @ each well.
PWR = parttially weathered rock
DTW = depth to water