Loading...
HomeMy WebLinkAboutNCG130045_FCR Greensboro LLC_2021 Inspection.pdfr City of Greensboro North Carolina September 3rd, 2021 David White FCR Greensboro, LLC 706 Patton Ave Greensboro, NC 27406 RE: Industrial Compliance Inspection Inspection location: FCR Greensboro, LLC 706 Patton Ave SW Permit #: NCG130045 Dear Mr. White: On September 2nd, 2021, the City of Greensboro Stormwater Management Division completed an industrial compliance inspection of FCR Greensboro, LLC. Local regulations permit an inspection of industrial facilities under authority granted by the City of Greensboro Code of Ordinance Chapter 30, Article 12, Section 7.1 (C-5). This inspection consisted of two parts: a review of the facility files/records and an on -site facility inspection. The inspection was performed by Elea Reyna Ocampo and Blake Strumbel. The following deficiencies/observations were noted during the inspection. Stormwater Pollution Prevention Plan/Spill Plan Review Site Maps and SWPPP • No deficiencies observed. Spill Prevention and Response Plan • No deficiencies observed. Monitoring • No deficiencies observed. Employee Training • Maintain an up-to-date and easily accessible printed copy of the annual employee training records in the Stormwater Pollution Prevention Plan. David White FCR Greensboro, LLC Industrial Inspection Letter Dated 9-3-2021 Page 2 of 2 Site Inspection Preventative Maintenance/Good Housekeeping • Properly dispose of mud, sediment, debris and waste that is located throughout the entire facility's impervious surface areas and that are exposed to precipitation. • Establish a procedure to periodically remove any waste from impervious areas and that are exposed to precipitation in order to prevent any wastewater runoff from entering the stormwater conveyance system. • Properly dispose of the containment booms that are located at the two main stormwater outlets at the west and east side of the property. Replace saturated containment booms with new ones. • Establish a procedure where new containment booms are placed at the outlets, and are monitored and replaced whenever these seem saturated. It is recommended that you document the disposal of these booms. Non-Stormwater Discharges Wastewater (stormwater runoff mixed with mud, sediment, debris and waste) is exiting the property. Establish a procedure to remove the mud, sediment, debris and garbage periodically (as mentioned above) so that the there is no wastewater exiting the property. It is recommended that FCR Greensboro LLC take appropriate actions to correct the noted deficiencies. We appreciate your cooperation and proactive approach to this matter. If you have any questions concerning this inspection, please contact me at 336-412-6202 or eleazer.reyna- ocampo@greensboro-nc.gov. Sincerely, Z&aly, 9 oc" 0 Elea Reyna Ocampo, Water Quality Specialist City of Greensboro, Water Resources Department cc: Peter Schneider, Water Quality Supervisor N.C. Dept. of Environment and Natural Resources Industrial Inspection File P.O. Box 3136 m Greensboro, NC 27402-3136 ® www.greensboro-nc.gov m (336) 373-CITY (2489) ® TTY # 333-6930