Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032285_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality October 8, 2007 Mr. David Treme, City Manager City of Salisbury 217 South Main Street PO Box 479 Salisbury, NC 28145 Subject: Permit No. WQ0032285 City of Salisbury Stoneglen Subdivision 15Q Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme, er(cfc,/,i In accordance with your application received on October 1, 2007, we are forwarding herewith Permit No. WQ0032285, dated October 8, 2007, to the City if Salisbury for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper No ehCarolina 7atllralli 2 Mr. Treme Page 2 October 8, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Salisbury for the construction and operation of approximately 1,458 linear feet of 8-inch gravity sewer and the discharge of 13,200 gallons per day of collected domestic wastewater into the City of Salisbury existing sewerage system, pursuant to the application received October 1, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Salisbury WWTP (NPDES No. NC0023884) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit File Darryl Wagoner, Salisbury Engineering and Planning Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials. as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. .In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 8th day of October, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION lh L__, for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032285 3 Past Track Engineering Certification Permit No. WQ0032285 October 8, 2007 Owner)WQCSIIMWTP David Treme City of Salisbury 217 S. Main Street PO Box 479 Salisbury, NC 28144 PE Darryl Wagoner Salisbury Engineering and Planning 516 —A North Main Street Salisbury, NC 28144 Complete and submit this form to the permit issuing regional office with the following: o One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required.supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Stoneglen Subdivision, a Rowan County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 1 ' ' L rlr SALISBURY ENGINEERING & PLANNING 516-A NORTH MAIN STREET • SALISBURY, NC 28144 September 28, 2007 DENR Division of Water Quality 610 East Center Ave., Suite 301 Mooresville, N. C. 28115 RE: Sanitary Sewer Extensions to serve Stoneglen Subdivision Rowan County Dear Sir or Madam: DARRYL L. WAGONER, P.E. 704-633-8550 I OCT - 1 2007 NC DENR MR0 DIVQ-S face 'elf ;tGi Protection PIease find enclosed two applications and a check for $480.00 for approval for the above referenced project. Please advise immediately if additional information is required. Enclosures Sincerely, Darryl FAST -TRACK APPLICATION fur GRAVITY SEWER i, PI I1' STATIONS, AND FORCE MAINS PAGE 3 C 0 LL G z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1, Owner: la City of S'alisbuy Full Legal Name parry, municipality, HOA, utility etc 1 b David, W, Treme, Signing Official Nar and Tite (F°°lease review The legal entity who will own this system is: D individual D Fedeara Cate ..i aalit, ( Stater 1 cS. P. O, Box 479 h�1ailing A,.dres N.C. State Tel ep h Project (Face Stcnµeilen.Subdi f Project Name (,p 3. Contact Person: Facsimile his non'( nt), Application Number: (to be completed by DWQ C-ta(b) for a thorie signrrktl Private Salisbury City 28145 Zip Cope Crnikl,,5s nirrl1 v.a cranty `,Vher e Project 3a, Darryl Wagoner„ 0wne r SE&P _ _ ._._ Name and Affiliation of Someone Who Can Answer Questions About tins Applrrcatio 3b. 704-633-8550 3c. seandp@aol Phone Number E-mawV e 1 Project is i1 New [] Modification (of an existing permit) If Modification, Permit No . For separate sheet clearly modifications, attach a sep to y explaining the reason for the modification (i,e. adding another phase, changing line sizeflength, etc.}. Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit, 2 Owner is Z Public (skip to Item 8(3)) D Private (go to Item 2(a)) 2a, If private, applicant will be 2b. If sole, fa ciCitres owned by a ese one) [] Retail rig Ownership (i.e store, church, single office, etc.) or [.] Public Utility (Instruction HI) [] Leasing l.in'its (lots, tovrnhomes, etc. - skip to item 3(3,)) '0 Homeowner Assoc./Developer (Instruction IV) ❑ Seliing units (lots, townhornes, etc. ,. go to Item B(2b)) Salisbury _...._ w tie!'` of'Wastewater Z re a,.re t Facility ('a' W1 r `t Treating V astev bury_ Rc wan WA rTP (Tevin Creek Train) e of VVWTF. City rvof Salisb,urfLi ,. Owner of Downstream Sewer The Origin of this wastewater L' Residential Subdivision Apartrnents'Coridem;Ersirin CI Mobile Horne Park [] School 0 Restaurant 0 Office Volume of wastewater tea bo allocatec *Do not include previously permitted al 0a g Sewer Size [] Force Mein t ape El Car Wash [] Instituuxrrn r] Hospital [] Church EW] Nursing [_1 Other (sp particular prc ati©ns If the permitted flow is zero Indicate why Interceptor Line - Flow will be permitted in a hsE.citi nt permits 'that connect [ Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewero new flow expected Waterhody Name F Permit No v ervre„ ruitarnan on requested Stream Index Number Current Class )f Downstream S 10 ` o Domestic/Commen i:r:i `ib Industrial Subbasin SALISBURY ENGINEERINGPLANNING 516-A NORTH MAIN STREET • SALISBURY, NC 28144 September 28, 2007 DENR Division of Water Quality 610 East Center Ave., Suite 301 Mooresville, N. C. 28115 RE: Sanitary Sewer Extensions to serve Stoneglen Subdivision Rowan County Dear Sir or Madam: DAFiRYLL., WAGONER, RE.. 704,-633-6550 NC DENR MRQ Mir.u. Surface tr44..... Please find enclosed two applications and a check for $480.00 for approval for the above referenced project. Please advise immediately if additional information is required. Sincerely, Darryl Enclosures