Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0030611_Regional Office Historical File Pre 2018
Michael FEasley', Governor William G. Ross Jr.„ Secretary , 'North Carohna Department. of Environment and Natural Re:sources. Alan W. Klimek,„PE. Director Division of Water Quality " August 4, 2006 Mr. Beauford Taylor, Mayor Town of Rockwell PO Box 506 Rockwell, NC 28138 Subject: Permit No, WQ0030611 Sunshine Manufacturing Structures Town of Rockwell Wastewater Collection System Extension Rowan County, North Carolina Dear Mr, Taylor: In accordance with your application received on August 4, 2006, we are forwarding herewith Permit No. WQ0030611, dated August 4, 2006, to the Town of Rockwell for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave,. Suite 11l 1oorcavi1le, NC 2811.5 Internet: WWW, n cwale rq u a 14 ,org Customer Service I-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Recycle.d110% Posl Consumer Paper Phone.: (704) 663-1649 Fax.: (704) 663-6040 One ,arolina zturailj Mr. Taylor Page 2 August 4, 2006 in accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Rockwell for the construction and operation of approximately 2,216 linear feet of 8-inch gravity sewer to serve the Sunshine manufacturing Structures project, and the discharge of 15,700 gallons per day of collected domestic wastewater into the City of Salisbury's existing sewerage system, pursuant to the application received August 4, 2006, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Salisbury WWTP (Yadkin River Regional/Town Creek Train WWTP NPDES No. NC0023884) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, _please contact Dee Browder at (704) 663-1699. Sincerely, I for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WVVTP Permit No. NC0023884) Charles Shue, McKim & Creed Surface Water Protection Central Fifes Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater • to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The waters which may be impacted in the event of a power failure at the pump stations permitted herein are classified as C waters. In accordance with 15ANCAC 2H .0219 (h) (3), a letter of power reliability for the subject area has been provided from the local power distributor authority, and included in the application package. Additionally it has been shown that the pump station will provide a minimum of 4 hours storage in the event of a power failure. 12. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or 2 b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that' the SSO was beyond control. Permit issued this the 4th day of August 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek E., Director Division of Water Quality • By Authority of the Environmental Management Commission Permit Number W00030611 3 Fast Track Engineering Certification Town of Rockwell Permit No. W00030611 August 4, 2006 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial E Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Sunshine - Manufacturing Structures, a Rowan County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28116 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Central Files: APS SVVP 08/04/06 Permit Number WQ0030611 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer • A - Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 15700 Facility Facility Name Sunshine Manufacturing Structures Location Address Owner Major/Minor., • • Region Minor_ • ' .` Mooresville • 'County Rowan Facility Contact Affiliation r Owner Name 1 Owner Type Town Of Rockwell Government - Municipal Dates/Events Orig Issue App Received 08/04/06 Draft Initiated Scheduled Issuance • Owner Affiliation Harold, Earnhardt PO Box 506 Rockwell NC 28138 Public Notice Issue Effective Expiration Regulated Activities Re . uestedlReceived Events Additional information requested Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS. PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! / r ' Application (lumber: 90030 (to be completed by DWO)1110 y Z o H Q re 0 ZMailing "- Z F () --I D. Q Q 1. Owner. 1 a. Town of Rockwell Full Legal Name (company, municipality, HOA, utility, etc.) ib. Beauford Taylor, Mayor Signing Official Name and Title (Please review 15A NCAC 2H ,0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: Private Partnership ❑ Corporation Cl Other (pecify): • Individual ❑ Federal ® Municipality ■ State/County ❑ Id. PO Box 506 1 e. Rockwell Address ) City 1 f. NC ;lg. 28138 State ; Zip Code lh. 704-279-2180 Ili. 704-279-0454 Il j. L clerk@rockwelinc.org Telephone I Facsimile E-mail 2. Project (Facility) Information: _ 2a. Sunshine Manufactured Structures Sanity L 2b. I Rowan County Brief Project Name (permit will 3. Contact Person refer to this name) County Where Project is Located _ 3a. Jeffery B. Jones; Salisbury -Rowan Utilities i Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-638-2146 3c. jione@salisburync.gov I Phone Number E-mail Z Q 1- ctOwner ce 0 LL. Z l — M 17C LL1 O. id (of an existing permit) If Modification, Permit No.: j1. Project is ® New ■ Modification 1 For modifications, attach a separate sheet clearly explaining the reason for the modification (I.e. adding another phase, changing tine sizeflength, etc.). Only include the modified information in this permit application - do not i duplicate project Information in B(7) and B(10-11) that has already been Included In the original permit. B(3)) El Private (go to item 2(a)) '2. Owner is 4 Public (skip to item 2a. if private, applicant will be: ❑ Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose or) ❑.Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) 3. City of Salisbury of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Salisbury -Rowan WWTP — Town Creek Train fib. NC0023884 Name of WWTF WWTF Permit No. 5a. City of Salisbury 5b. 8" Receiving ® Gravity Sewer Size ■ Force Main 5c. Owner of Downstream Sewer Permit Number of Downstream Sewer (if known) 6. The crigin of this wastewater is (check all that apply): 0 Car Wash ❑ Institution ❑ Hospital ❑ Church 0 Nursing Home ® Other (specify): Manufacturing 100 % Domestic/Commercial 12 Residential Subdivision ■ Apartments/Condominiums . • Mobile Home Park % Industrial 0 School 0 Restaurant ❑ Office % Other (specify): 7. Volume of wastewater to be allocated for this particular project: allocations 15,700 gallons per day *Do not include previously permitted 8. If the pemiitied flow is zero, indicate ❑ Interceptor Line - Flow will ❑ Flow has already been allocated • Rehabilitation or replacement why: be permitted in of existing in subsequent Permit No. permits that connect to this line new flow expected sewer with no FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 B. PERMIT INFORMATION .(CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow In accordance with 15A NCAC 2H .0219(f) for item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). Residential: 55 lots @ 240 gpd'lot=13,200 gpd plus one manufacturer:100 Design Flow=15,700 gpd employees if necessary) @ 25 gpd/employee=2500 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets Size (inches) - 8 - 4 — ---- - - -- Length • 2,216 (feet) Gravity or Force Main (use tho.pull down menu) Gravity ENTER TOTAL LINE LENGTH IN MILES 0.42 miles 11. Summary of Pump Stations to be Permitted (attach additional sheets (2,216 ft) as necessary) Location ID (self chosen - as shown on plans for cross-reference) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (1- dual line feed; 2- permanent generatorwlATS; 3- portable generator wltelemetry; 4-wet well storages 12. Does the sewer system comply Force Mains (latest version), applicable? with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as reference the pertinent minimum design criteria or regulation and indicate why a is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS TO THE VARIANCE WITH YOUR APPLICATION r Yes ❑ No if no, please variance PERTINENT 13. Have the following permits/certlfications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Storrnwater? ►i Yes • No ■ NIA LI NIA ® NIA ►21 Yes • No 0 Yes 0 No '14. Does this project involve aerial lines or siphons? Check if yes: Theselines-wil be_consideredhfah arianiv and must be_ctiecked_once_evenr_sixmonths 15. Does this project have gravity sewer lines designed at minimum Be aware that the Division will net accept instatled lines more than 10% flatter than corrected prior to submitting the final engineering cerlifcaron.. I slopes? ■ the minimum slope, Lines installed outside this tolerance should be FTA 02103 - Rev. 3 04105 FAST -TRACK API LICAT 'ON for GRA."'-ITY SE '"ERS, PU P STA.°' '1 4S, AND Et RCE MAINS PAGE 5 0 0) z 0 . Use the Division's guidance document entitled, ""DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: El A Stream Classification is not needed because all parts of the project are at least 100 fee waterbody; AND, ® A Stream Classification is not needed because the design does not depend an wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. ay from any down slope Location ID on Map (self chosen as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification A Unnamed Stream Rowan Yadkin N/A C Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: t, Beauford Taylor, attest that this application for the sanitary sewer to serve Sunshine Manufactured Structures has been reviewed by me and is accurate and complete to the best of my knowledge, i understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: to accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 1a, Signing Official Sig 2, Professional Engineer's Certification: bid Date I attest that this applii"cation for the sanitary sewer to serve Sunshine Manufactured Structures has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations,, and all other supporting documentation to the best of my knowledge. t further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February' 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted" June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note.- In accordance with NC General Statutes 143-215, 6A and 143-215, 6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10„000 as well as civil penalties up to $25,000 per violation. 2a. Charles E. Shue Professional Engineer Name 2b. Mckm & Creed Engineering Firm 2c. 8020 Tower Point Drive Mailing Address 2d. Charlotte 2e, NC 2f, 28269 City State Zip 2g. 704-841-2588 the 704-841-2567 2i. cshue@mckimCreed.com Telephone Facsimile E-mail Seal Signature & Date FTA 02,103 - Rev. 3 04'`05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) Z Q F, n e■ Q ZMailing — Z 2 aTelephone C.)1222. J 0- < Q I. .Owner: 1 a. Town of Rockwell Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Beau`ord Taylor, Mayor Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Private Partnership 0 Corporation ❑ Other (specify): Individual ❑ Federal r� Municipality ■ State/County ld. PO Box 506 Il e. Rockwell Address I City 1f. NC ,1g. 28138 State I Zip Code lh. 704-279-2180 Ili. 704-279-0454 Ij. clerk@rockwellnc.org I Facsimile 1 E-mail Project (Facility) Information: Qa. Sunshine Manufactured Structures Sanitary Sewer Proiect 2b. Rowan County I Brief Project Name (permit will refer to .3. Contact Person: this name) I County Where Project is Located 3a. Jeffery B. Jones; Salisbury -Rowan Utilities Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-638-2146 3c. jlone@salisburync.gov Phone Number I E-mail Z Q I-- < re O IL Z E— Ix W a m l. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate phase, changing line sizellength, duplicate project information in sheet etc.). B(7) and clearly explaining Only include B(10-11) that the reason for the modification (i.e. adding another the modified information in this permit application - do not has already been included In the original permit. B(3)) (go to Item 2(a)) 2. Owner is a Public (skip to Item ■ Private 2a. If private, applicant will be: church, single office, etc.) or etc. - skip to item B(3)) etc. - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) (instruction 111) Assoc./Developer (Instruction IV) ❑ Public Utility 0 Homeowner ■ Retaining Ownership (i.e. store, ' ❑ Leasing units (lots, townhomes, ■ Selling units (lots, townhomes, 3. City of Salisbury WT Owner of Wastewater Treatment Facility (WF) Treating Wastewater From This Project '4a. Salisbury -Rowan WWTP — Town Creek Train 4b. NC0023884 , Name of WWTF WWTF Permit No. 5a, City of Salisbury 5b. 8" Receiving Sewer Size r Gravity • Force Main 5c. ' Owner of Downstream Sewer Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): 1 Residential Subdivision ❑ Car Wash ❑ Institution ❑ Hospital ❑ Church ❑ Nursing ® Other Home (specify);. Manufacturing 100 % DomesticlCommercial • Apartments/Condominiums • Mobile Rome Park % Industrial ■ School • Restaurant %Other (specify): ■ Office 7. Volume of wastewater to be allocated for this particular project: allocations 15.700 gallons per day *Do not include previously permitted B. If the permitted flow is zero, indicate ❑ Interceptor Line - Flow will why: be permitted in of existing in subsequent permits Permit No. that connect to this line expected ■ Flow has already been allocated D Rehabilitation or replacement sewer with no new flow FTA 02103 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 B. PERMIT INFORMATION (CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 21-1 .0219(1) for Item B(7) or the design flowfor line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). Residential: 55 lots @ 240 gpd+tot= 13,200 gpd plus one manufacturer: 100 employees @.25 gpolemployee=250D gpd Design FIow=15,700 gpd 10. Summary of Sewer Lines to. be Permitted (attach additional sheets if necessary) Size (inches) Length 2,216 (feet) Gravity or Force Main (use the pull. down menu) 13- - - Gravity t 1 i . ENTER TOTAL LINE LENGTH IN MILES: 0.42 miles .to be Permitted (attach. additional sheets (2,216ft) 11. Summary of Pump Stations as necessary) Location ID (self chosen - as shown on plans for cross-reference) Design FlowOperational (MGD) Point GPM © TDH Power Reliability Option (1- dual line feed; 2- permanent generator w1ATS; 3- portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply Force Mains (latest version), applicable? with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as reference the pertinent minimum design criteria orregulation and indicate why a is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS TO THE VARIANCE WITH YOUR APPLICATION 0 Yes ❑ No if no, please variance PERTINENT 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or401 Certification? Sedimentation and Erosion Control Plan? Stormwater? ® Yes ❑ No • N/A j],NJA r Yes 0 No 0 Yes 0 No ►7 N/A 14. Does this project involve aerial lines or siphons? Theseiines_vrlll_be_consldered hiah_adority and must _be cttecked_onc 15. Does this project have gravity sewer lines Be aware that the Division will not accept installed lines corrected prior to submitting the final engineering certificat'.on., Checkif yes: ►X even/ si:unonths designed at minimum slopes? ❑ more than ID% {latter than the minimum slope. Lines installed outside this tarerence should be PTA.02103 - Rev. 3 04i05, 23' 30.00"W a Nate: ROCKWELL Date: 6(5/2006 Scale: 1 inch equals 1000 feet Location: 035' 32` 47.2" N 080 ° 23' 41,9" W Caption: Salisbury -Rowan Utilities Sunshine Manufactured Sanitary Sewer C©pyncghl (C) 1997, M ptech, 1n July 10, 2006 Mr, Charles E. Shue, P.E. McKim & Creed 8020 Tower Point Drive Charlotte, North Carolina 28269 RE Sunshine Manufactured Structures Sanitary Sewer Project. Dear Mr. Shue, The City's wastewater treatrnent facility, the Salisbury -Rowan Wastewater Treatment Plant Town Creek Train, permit # NC0023884, and collection system have sufficient capacity to support an estimated additional flow of 15,700 gpd created by Sunshine Manufactured Structures Sanitary Sewer Project. If you have any questions or comments please, contact me at (704) 638-2146. Cc: File 1 Water Street Salisbury, NC 28144 Sincerely, Jeffrey B. Jones, P.E. Utilities Engineer Salisbury -Rowan Utilities Telepaone (704) 638-5205 Utilities Engineering Division Fax (704) 638-8491 FW: Sunshine Manufactured Structures FTA Information Subject: FW: Sunshine Manufactured Structures FTA Information From: "Jeff Jones" <Jjone@salisburync.gov> Date: Fri, 4 Aug 2006 09:35:12 -0400 To: <Dee.Browder@ncmail.net> Dee, Attached are the revised sheets 3 and 4 along with the flow acceptance letter from SRU. If you have any questions, please let me know. Thanks for you help with this project. Best regards, Jeff Jones Senior Engineer Salisbury -Rowan Utilities (704) 638-2146 jjone@salisburync.gov Content -Description: Document.pdf Document.pdf, Content -Type: application/pdf Content -Encoding: base64 _ E 1 of 1 8/4/2006 9:39 AM