Loading...
HomeMy WebLinkAboutWQ0023708_Regional Office Historical File Pre 2018oF�A "7-R Michael F. Easley, Governor OG William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources =1 Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality March 24, 2004 Mr. David Treme, City Manager City of Salisbury P. O. Box 479 Salisbury, North Carolina 28145 Subject: Permit No. WQ0023708 City of Salisbury Olde Salisbury Lots 54 & 55 Wastewater Collection System Extension Rowan County, North Carolina Dear Mr. Treme: In accordance with your application received on March 22, 2004, we are forwarding herewith Permit No. WQ0023708, dated March 24, 2004, to the City of Salisbury for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. NCDENR Mooresville Regional Office Internet http://h2o.enr.state.nc.us/ 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. David Treme Page 2 March 24, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Ruies, and Regulations, permission is hereby granted to the City of Salisbury for the construction and operation of approximately 361 linear feet of 8- inch gravity sewer to serve Salisbury Phase 1 and Phase 2 as part of the Olde Salisbury Lots 54 & 55 project, with no additional discharge of collected domestic wastewater (flow has already been allocated in Permit No. WQ0019008) into the City of Salisbury's WWTP (NPDES No. NC0023884) existing sewerage system, pursuant to the application received March 22, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Rowan County Health Department Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0023884) Darryl Wagoner, Salisbury Engineering & Planning Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A. NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project -shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit;. 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division -approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 24th day of March, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, PO.., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0023708 3 Fast Track Engineering Certification Permit No. WQ0023708 March 24, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps,system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, D weekly, ❑ full time) the construction of the Olde Salisbury Lots 54 & 55, Rowan County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. AST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE I Number: USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! USE(to be completed by Dwq W Q Z3 Tog 1. Owner: _ ...... _.. ._ .._ .. 'ta.4 City of Salisbury ll Legal Name (company, municipality, HOA, utility, etc.) Fu- - 1b. David W. Treme, City Manager O Signing Official Name and Title (Please E"' lc. The legal entity who will own this system ❑ Individual ❑ Federal @ Municipality tY Id. P. O. Box 479 review 15A NCAC 2H .0206(b) for authorized signing officials!) is: ❑ State/County D Private Partnership ■ Corporation IN Other (specify): 1e. Salisbury O Street Address City t1.. If. N.C. 1g. 28145 z State Zip Code 0 1h. (704) 638-5270 li. (704) 638-5232 1j. QTelephone Facsimile E-mail O 2. Project (Facility) Information: 2a. Olde Salisbury Lots 54 & 55 2b. Rowan Q„ Brief Project Name (permit will refer to this name) County Where Project is Located < 3. Contact Person: Q 3a. Darryl Wagoner, Owner SE & P Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (:704) 633-8550 3c. seandp@aol.com Phone Number E-mail 1. Project is hi New it) if 2 Owner is @ Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: ❑ Retaining Ownership (Le. store, ❑ Leasing units (lots, townhomes, ❑ Selling units (lots, townhomes, etc. 2b. If sold, facilities owned by a (must choose one) church, single office, etc.) ❑ Public Utility (Instruction 111) etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV) - go to Item B(2b)) c) 3. City of Salisbury QOwner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4C 4a. Salisbury Rowan WWTP 4b. NC0023884 Name of WWTF WWTF Permit No. ce O 5a. City of Salisbury 15b. 8" Vic. WQ oo.goo8 ZOwner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer Fi 6. The origin of this wastewater is (check all that apply): E4 Residential Subdivision ■ Car Wash Ce W • 0 Apartments/Condominiums ■ Mobile Home Park IN Institution 1 00 % Domestic/Commercial 0 Hospital D Church % Industrial f1 ■ School 03 ■ Restaurant • Nursing Home /° ° j (specify): • O Office ❑ OtherOther (specify): 7. Volume of wastewater to be permitted in this project: 0 gallons per day 8. lithe permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Flow has already been allocated in Permit No. WQ 0 019008 ■ Rehabilitation or replacement of existing sewer with no new flow expected 3 FTA 02/03 ST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 B. PERMIT INFORMATION (CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .02190(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality. Non -Discharge Permitting Unit, 1517 Mail Service Center,:Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). 1 P2 7o .5 ✓� 4fkt.rSR3�Q'F P 0 1�1,vg WA'6:7--*oG47 2.) M 73rt1 E'Y 2 10 1 s • 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" 361 ENTER TOTAL LINE LENGTH IN MILES 0 . 07 mi . Gravity or Force Main (pull down menu) Gravity Gravity Gravity Gravity Gravity Gravity Gravity 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Power Reliability Option Location ID Design Flow Operational Point (dual line feed, permanent generator, (as shown on plans) (MGD) GPM @ TDH portable generator, wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?! ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? D Yes ❑ No ® N/A Stormwater? ❑ Yes' ❑ No ® NIA V GO.[r 5:41.rsgww7 1-42 r-5 54' ; SS FTA 02/03 %-TRACK APPLICATION for GRAVITY SE'ERS, PUMP STATIONS, Al' ? FORCE l►° AINS PAGE 3 0 1, Use the Division's guidance document entitled, "DETFRMIN'NG STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets asI necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate Uu s: following A'Watershed Classification is not needed because all parts of the project are at least t 100 feet a y from any down slope waterbody; AND, [1 A "Watr_ rsta d Classification ,sificatiion is not r Ire°dad because reliability option for zany pump stali n ray ar xr Cass C rnwn si":a~to " 'erbody. Location ID Name of on Map Waterbody County Basin depend on wet v e i storage as a pc-Awl- Waterbody Stream Waterbody Index Classification Site Crane Creek Rowan Yadkin 12-115.5 C Submit the 8,5" x 11" topographic map as required in tnstructrr n VI regardless of whether a classification is provided! 1. Applicant's Certification: ! attest that this €application fr r O1 de Salisbury Lots 54 ass Ekfu7 reviewed by me and is atcur try and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with Morlh Carolina General Statutes 143-215.6A and 143a215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a 6ne not to exceed $10 000 as well as civil penalties up to $25,000 per violation. n Professional Engineer's Certification. Olde Salisbury l attest that this application for has been reviewed by me and is accurate, complete and consistent with .the inforrnatici19ntt e ee cf ne'rinrj j7lans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain perrtions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Mate: In accordance with NC General Statutes 143-215.6A and 143-2.15:66, any person who knowingly makes any false statement„ representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a 6ne not to exceed $10,000 as well as civil penalties up to $25,000 per violation. "" 7,, GA 2a, Da rryl_ onar Professional Engineer Name 2fr. S a l l shu.ry.__Engineering -__w Platei n g. Engineering Firm 91 6 A Irlt-r. Address 2d..Sal i burg City ate Zip 2g, 704-633-85TO. 704-633.-. 55 i. SEANL)P A0L.cote Telephone Facsimile E-mail FTA 02/03 03/23/04 Permit Number WQ0023708 Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 0 Facility Facility Name Olde Salisbury Lots 54 & 55 Location Address Owner Permit Tracking Slip Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Major/Minor Minor Region Mooresville County Rowan Facility Contact Affiliation David Treme PO Box 479 Salisbury NC 28145 Owner Name City of Salisbury Dates/Events Owner Type Government - Municipal Owner Affiliation Matt PO Box 479 Salisbury Bernhardt NC 28145 Scheduled Orig Issue App Received Draft Initiated Issuance 03/22/04 Regulated Activities Public Notice issue Effective Subdivision Wastewater collection Outfall NULL 4f 2.4 /04- Requested/Received Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin SAL LIMY ENGINEERING &. PLANNING 516-A NORTH MAIN STREET • SALISBURY, NC 26144 DARRVL L. WAGONER, RE, 704-033• 8560 March 19, 2004 DENR Division of Water Quality 919 N. Main Street Mooresvi I le, N. C. 2.8115 RE: Sanitary Sewer Extensions to serve Olde Salisbury Lots 54 & 55 Rowan County Dear Sir: Please findenclosed two applications for approval for the above referenced project. Please advise immediately if additional information is required. Sincerely, D Enclosures