Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0039952_Regional Office Historical File Pre 2018 (2)
Water Resources Em°oromenwl Quaky May 3, 2018 Mr, Fletcher Gregory, Director of Finance Charlotte Latin Schools, Inc. 9502 Providence Road Charlotte, NC 28277 ROY COOPER M'ICHAEL S. REGA.N SecrEtan.` LINDA CULPEPPER. I,nterurt Director Subject: Permit No. WQ0039952 Charlotte Latin Schools, Inc, Charlotte Latin School - New Upper School Wastewater Collection System Extension Permi Mecklenburg County Dear Mr. Gregory: In accordance with your application received May 1, 2018, we are forwarding herewith Permit No. WQ0039952 dated May 3, 2018, to Charlotte Latin Schools, Inc. (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11,1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T ,0403 or any individual system -wide collection system permit issued to the Permittee, It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding, - "N©tfifng Compares. ate t" Say fh Carolina Envuonmentai.. Quality Wafer Resources Water Qualir,, Rewiooal Operarions Mauresvilde Ite corral Office F 610 East Center Avenue, Suite 301 ` Mooresville, Nortlr Carolina 38T 15 704-663-I699 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. Sincerely, DocuSigned by: A14CC681AF27425... by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Frank G. Miller, P.E. (e-copy) Barbara Grosse -copy) Tommy Rowland (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) 2 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Charlotte Latin Schools, Inc. Mecklenburg County for the construction and operation of approximately 317 linear feet of 8-inch gravity sewer as part of the Charlotte Latin School - New Upper School project, and the discharge of no new flow (line relocation) of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received May 1, 2018, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. DocuSigned by: A14CCG81A1-27425... by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0039952 Permit Issued: May 3, 2018 3 SUPPLEMENT TO PERMIT COVER SHEET Charlotte Latin Schools, Inc. is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NC0024970. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS 1. No new flow shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between Charlotte Latin Schools, Inc. and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. 115A NCAC 02T.0304(h)] II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 027.0110] 4 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. if an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. 5 j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)1 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. 6 b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 115A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope pert re Division's Gravity Sewer Minimum Design Criteria shallnot be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .01161 101 Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(6)] 7 12, The issuance of this permit shall not exempt the Permittee from complying with any and all statutes,. rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. LG,S. 143- 215.1(b)I FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Charlotte Latin Schools, Inc. PERMIT #: WQ0039952 PROJECT: Charlotte Latin School - New Upper School ISSUE DATE: May 3, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether_partials have been submitted. PERMITTEE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEERS CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (n periodically, n weekly, 1 full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office' 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 LITTLE PY15/�W.41PUF�0 APW,I rfnal.liq TO, From: Little 5815 Westpark Drive Charlotte, NC 28217 To: NCDEQ 610 East Center Avenue Mooresville, North Carolina 28115 WE ARE SENDING YOU: ❑ Shop Drawings Copy of Letter Copies 2 Date 04/20/18 Attached ❑ Prints ❑ Change Order 2 04/20/18 n/a n/a 04/19/18 Num WQROS ,:w tf = (DC ��: � Loafer of Transmittal Date. April 20, 2018 Under separate cover via UPS the ❑ Sam,pies ❑ Speci ❑ Other See Below scnptron Fast -Track Sanitary Sewer Extension Application Cover Letter Site Map (USES Map) Site Map (Aerial) Review Fees ($480 00 Job Number: 112.5779,00 Action Req'd THESE ARE TRANSMITTED AS CHECKED BELOW: For approval For your use As requested For review and comment For bids due ❑ Reviewed El Rejected ❑ Furnish as Corrected ❑ Not marked El Revise and Resubmit ❑ Submit copies for distribution ❑ Return corrected prints ❑ Prints returned after loan to us REMARKS: Attached is the Fast-rf rack Application for the private sanitary sewer line rehabilitation at Charlotte Latin School. Please let us know if you need anything else for review and approval. Thank you. COPY TO if enclosures are not as noted, please notify us. Signed: _ Frank G. Miller PE. Email: fmiller@littleonline.com LITTLE . April 30, 2018 DWQ Division of Water Resources Mooresville Regional Office Water Quality Section 610 Center Avenue Mooresville, NC 28115 Re: Charlotte Latin School - New Upper School Fast Track Sewer System Application To Whom It May Concern; Attached you will find the following for the referenced project 1. One original and one copy of the application with attachment 2. The application fee of $480 3. 8.5"x11" color copy of a USGS topo map with project location 4. 8,5"xi 1" color aerial map with project location The Charlotte Latin School - New Upper School project Is to construct a new high school classroom building that will also house new administration offices. One existing classroom building and the existing administration building will be demolished as part of this project, Part of the existing sewer system will need to be relocated to build the new building. The total K-12 student body at Charlotte Latin School is about 1,400 students and is not expected to increase.. The existing sewer system at Charlotte Latin was installed around the year 1970. The personnel involved with the school at that time are no longer associated with the school. No existing permit information has been found in the files. Sincerely, 0r line. corn 704-581-7451 vac 704,525 53,C raK 704 5e I e721 State of North Carolina Department of ;nvironmentaDl Quality Division of Water Resources 'AC 02T .0300 — FAST TRAC:K SEWER SYSTEM EXTENSION APPLICATION ETA 04-16 & SUPPORTING DOCUMENTATION Application Number be eompleted 'dbyt°WR) APPLICANT INFORMATION: 1. Applicant's name: Charlotte Latin Schools, Inc. (company, municipality, HOA, utility', etc.) 2. Applicant type: 0 Indivxidual Z Corporation General Partnership © Privately -Owned Public Utility L Federal 0 State/County 0 Municipal 3, Signature authority's name: Fletcher Grregory per L 5 A N`;`A(" 02T .0I06(b) Title: Director of Finance Applicant's mailing address: 9502Providence Road City: Charlotte State: NC Zip: 28277-W 5. Applicant's contact information: Phone number: (704) 846-7299 Email Address: fgregory@charlotte:la in.org d R CI" iVED'NCDENS'IDWR 0 Other II. PROTECT INFORMATION: 1. Project name: Charlotte Latin SchtllmmNew leper School 2. ApplicationfProject status: Proposed (New Permit) LJ Existing Perrnit/Protect If a modification, provide the existing permit .nuniber: WQ00 and issued date: See Attachment If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located.: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.0788' Longitude:-80.7747' Parcel ID (if applicable): 2.25.13564 (or Parcel ID to closest downstream sewer) 7I. CONSULTANT INFORMATION: 1, Professional Engineer: Frank G. Miller License Number: 038668 Firm: Little Diversified Architectural C:"onsultingz,[nc. Mailing address: 5815 Westpark Drive City. Charlotte State: NC Phone number: (704) 561-7451 Lip: 28217- ...._ Email Address: WASTEWATER TREATMENT FATY (WWTF) LNFORMA''TION: 1r Facility Name: McAlpine WWTP Permit Numbers NC0924970 Owner Name: Charlotte Water \AOROS Vll.l,E Ft".rc tt7NA.. OFF) RECEIVING DOWNSTREAM SEWER INFORMATION (i€ different than WWTF): 1. Permit Number(s): WQNCEMC 12197 Downstream (Receiving) Sewer Size: 12 inch System Wide Collection. System Permit'` untber(s) {ii;applicable": `a?v'QCS OwnerName(s)_ Charlotte Water FORM: F"fA 04-I6 Page 1 of 5 VL GENERAL REQUIREMENTS lithe Applicant •is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? D Yes LJNO N/A Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement FORM: DEV) been attached? Yes LINo N/A 3.If the Applicant is a Itome/Property Owners' Association, has an Operational AgyementAFORM: HOA.) been attached? D Yes No N/A 4. Origin of wastewater: (check all that apply): El Residential Owned El Residential Leased School / preschool 1. day care D. Food and drink facilities LI Businesses offices / factories E Retail (stores, centers, malls) Ej Retail with food preparation!service LI Medical / dental / veterinary facilities 0 Church Nursing Horne 5. Nature of wastewater : 1 00% Domestic/Commercial % Commercial % Industrial (See 1.5A NCAC 02T .0103120)) here a Pretreatment Program in effect? f. Has a flow reduction been approved under 15A NCAC 021' .01,14(0? Ilfyes,provide a copy of flow reduction approval letter 7. Surnrnarize wastewater generated by project: Atablishment Type (see 02T.0114(1)) 111 Yes • Daily Design Flow 2'h galgal gal/ gal gall gal/ No D Car Wash D. Hotel and/or Motels El Swimming Pool /Clubhouse Ej Swimming Pool/Filter Backwash fl Other (Explain in Attachment) 0 GPD a See 15A 'NCAC 021' .0114(bl (4,(e)(1) and (42) for caveats to wastewater design flow rates .e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property:located south or east of the Atlantic Intracoastal Waterway to be •used as vacation rentals as defined in (i..S. 42A-4), b Per I 5A NCAC 021° ,0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0 1 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPI) (per 152A NC:A( j.12T,1)1 14) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why; D Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit Number; Rehabilitation or replacement of existing sewer with no new flow expected El Other (Explain): FORM: FIA 04-16 Page 2 of' 5 Vil. GRAVITY SEWER DESIGN CRITERIA (If Applicable) 02T NIDC",(Grusity Seers): 1. Summarize gravity sewer to be permitted: Size (inches) 8 Length (feet) 317 Material D.I.P. 1 • Section Il & Ill of the MDC for Permitting of Gravity Sewers contains. information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & NIDC (Pump Stations/Force Mai COMPLETE FOR EACH PUMP STATIONINCLUDED IN THIS PROJECT Pump station number or name: .7.. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity-) 4. Operational point(s) of the pump(s): gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) feet total dynamic head crDH) Length (feet) Material 6. Power reliability in accordance with 1 NCAC 02T .„0305(h)(1): IJ Standby power source or pump with automatic activation and telemetry I 5A NCAC 02T .0.305(h)(1)(B); Required for all pump stations with an average daily flowgreater than or equal to 1.5,000 gallons per day r Must be permanent to 'facility Or if the pump station has an average daily flow less than I 5„000 gallons per day 1 Portable power source with manual activation, quick -connection receptacle and telemetry - I5A NCAC 02.T .0305(h)(I)(C) or El Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h,)(1)(C): • it shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (drafl agreement) and is compatible with the station. ▪ If the portable power source or pump is dedicated .to multiple pump stations, an evaluation °fall the pump stationsstorage capacities and the rotation schedule of the portable power source or pump, including travel timefra.mes, shallbe provided in the case of a multiple station power outage, FORM: FTA 04-16 Page 3 of 5 IX: SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)); 1 Does the project comply with all separations found in 15A NCAC 02T .0305(1)ft„ gj Yes No - 15A 'NCAC 02T„0305(f) contains minimum separations that shall be provided for sewer syste:ms: •. . . . . ,. . . .. . , „. , . , . ' 1 Setback Parameter* ' Separation12.equired Storm sewers and other utilities not listed below (vertical) 24 inches 'Water mains (vertical -water over sewer including_iin benched trenches) i-- Water mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply source, including any wells. WS-I waters ofClass 1 or (lass 11 int2unded reservoirs used as a source of drinking. water **Waters classified WS (except WS-1 or WS-V), B, SA. ORW. DOW, or SB from normal hi ah water (pr tide elevation) and wetlands (see item IX.2) **Any other stream, lake, im.poundment, or ground water lowering and surface drainage ditches An buildiNIfoundation Any basement Top slope of emban.kment or cuts of 2 feet or more vertical height Drainage ,systems and interceptor drains Any swimming pools .Final earth eade (vertical) -4- 18 inches 10 feet 18 inches 2 feet 100 feet 50 feet 10 feet 5 feet 10 feet 10 feet 5 feet 10 feet. 36 inches • 15A 'NCAC 0.2'T.0305(g) contains alternatives where separations in 021.. 3050:, cannot he achieved, • **Stream classifications can be identified using :the. Division's NC Surface Water Classifications webpage • If noncomplia:nce with 0211,9395aor (,0,. see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) El Yes No N/A >: See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction • As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? This would include Trout Buffered Streams per I 5A NC.AC 2B (1202 4. Does the project require coverage/authorization under a 404 Nationwide or: individual permits or 401 Water Quality Certifications? • Information can be obtained from the 401 & Buffer PermittingBranch [JesLJNo N/A El Yes No 5, Does project comply 1.vith I 5A NC A C 02 T,0 05(0(0) (additional permits/certifications)? Yes No Per 15A NCAC Q21,Q105,c '(!), directly related. environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, storniwater management plans, etc), 6. Does this project include any sewer collection lines that are deemed 'high -priority"' Per 15A NCAC 02 I.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject: to erosion that undermines or deteriorates the sewer, El Yes No N/A • If yes., include an attachment :with details for each line, including type (aerial line, size, material, and location), High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCA.0 021.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM, FTA 04-16 .Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I 5A NCAC 02 F, the Minimum Design Criteria for the Pei nittnoll,Ptmp,Stationsd and ForceMains ("latest y,ersioil and the Gravity Sewer Minimum Desin Criteria thitest version), as applicable? E Yes El No If No, complete and submit the Variance/Alternative Design Request application ( V ADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents, Professional Engineer's Certification: Fraik EL fl Itr (Professional Engineer's name from Application Item-11El.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Seer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittalpackage, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design., NoTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine .not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's sea.1, signature„ and date:. 3, Applicant'Cprti Frtin per 5A NCAC 02T .0106: rsir V:ViCid4/1-Ce attest that this application for (Signature Authos n c 8e. title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge,. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition: of this permit be violated 1 also understand that if all required parts of this. application package are not completed and that if all required supporting information and attachments ate not included, this application package will be returned to me as incomplete, NOTE - In accordance with General Stat te 14.13-215.6,A and 143-215.6B,, any person who 'knowingly makes any false statement, representat or certification in application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to e 4,Sl0000 as well a. c il penalties up to $25,000 per violation.. Signature: Date: FORM: ETA 04-16 Page 5 of 5 . .E LITTLE DIVERSIFIED ARGNIIEOTIffAL OONSULTINO April 20, 2018 NCDEQ Mooresville Regional Office Water Quality Section 620 East Center Avenue Mooresville, North Carolina 28115 Reference: Charlotte Latin School — New Upper School Fast -Track Sanitary Sewer Application NCDEQ, The enclosed submittal is for a proposed rehabilitation of the existing private sanitary sewer system on the campus of Charlotte Latin School. This rehabilitation includes 317 LF of 8-inch ductile iron pipe gravity line. This submittal includes the following: • Cover Letter • Fast -Track Sanitary Sewer Application • Application Fee • Site Maps Please contact us if there are additional items needed for review and approval. Thank you. Sincerely, Little M Frank G. Miller, 5815 Westpark Drive Charlotte NC 28217 Voice 704.525.6350 Fax 704.561.8721 www.littleonline.com This map or report is p Users of this map or repor responsibility for the inform Polaris 3G Map — Mecklenburg County, North Carolina Charlotte Latin School bate Printed:4/10/20 2:52: 2 PM ed for the inventory of real property within Mecklenburg County and is compiled from recorded deeds, plats, tax maps, surveys, pianimetnc maps, and other public records and data, are hereby notified that the aforementioned public primary information sources should be consulted for venftcation. Mecklenburg County anapping contractors assume no legal anon contained herein, IF FAST TRACK SEWER ENGINEERING CERTIFICATION PERoNDFTEE: Charlotte Latin Schools, Inc. PERNN|T#: VVQ0039952 PROJECT: Charlotte Latin School - New Upper School ISSUE DATE: May 3,IOl8 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation, It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address atthe bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation ofthe permit and shall subject the Penmitteeto appropriate enforcement actions. The Permh1ee is responsible for tracking all partial certifications up until afinal certification breceived. AFinal Certification shall beacomplete set oyrecord drawings and design calculations regardless ofwhether partials have been submitted. PERIVITTEE'S CERTIFICATION ithe undersigned agent for the Pennittee hereby state that this project has been constructed pursuant tothe applicable standards & requirements, the Professional Engineer be|uxv has provided applicable design/construction information tothe Permittee' and the Pennbtee is prepared to operate & maintain the wastewater collection system permitted bene.in or portions thereof, V C M^A irte Printed Name, Title 5i8natw�e Da ENGINEER'S CERTIFICATION /� &� |' 1r'�� ��_ =* rw«��(,v_ ' as duly registered Professional E i rin the State ofNo�h Cmno|ina, having been authorized to observe (��=" periodically, . F— weekly, [� �� fu|| time) the construction of the project name and location as referenced above for the above Permittee hereby state that, tnthe best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A N[A[ 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February lZ, 1996,asapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June l'Z[K}0'osapplicable, and other supporting materials. North Carolina Professional Engineer's Seal w/s|8nature& date: Final Q$ Partial (include description) Certification Comment ualifier ich if necessary): m"C°/w,oh( "lo^na/em"*"=mmQuahn/ud°ut��Otjrm, 'A uoQ.a*ncg"vtal*�)omuou" m��a�n���mm�/w�n����w*�.���s"��/ m=�u./�x.x�c�a"z*u5 L� TT From Little 5815 Westpark Drive Charlotte, NC 28217 To: NCDEQ 610 East Center Avenue Mooresville., North Carolina 28115 WE ARE SENDING YOU: ❑ Shop Drawings ❑ Copy of Letter Copies 2 2 Date El Attached ❑ Prints • Change Order Number Date: August 2, 2018. Letter of Trans Job Number: 112.5779.00 a Attention NCDEQ Water Quality Section Re: Charlotte Latin School - New Upper School ❑ Under separate cover via UPS the following items: 0 Samples ❑ Specifications Other See Below Description Action Req'd 08/02/18 08/02/18 05/03/18 07/18/18 Fast Track Sewer Engineering Certification (Partial) Cover Letter Approval Letter (Permit #: WQ0039952) Sanitary Sewer As-builts (Plan & Profile) THESE ARE TRANSMITTED AS CHECKED BELOW: For approval ❑ For your use ❑ As requested ❑ For review and comment ❑ For bids due ___m� Reviewed 0 Rejected ❑ Furnish as Corrected ❑ Not marked REMARKS: Attached is the partial certification for Permit #: WQ00 ❑ Revise and Resubmit ❑ Submit copies for distribution ❑ Retum corrected prints El Prints returned after loan to us 9952 at Charlotte Latin School. Please let us know if you need nything else for revie nd approval. Thank you, COPY TO If enclosures are not as noted, please notr Signed: Frank G. Miller, PE Email: fmiller@littteonline.com August 2 2018 DWQ Division of Water Resources Mooresville Regional Office Water Quality Section 10 Center Avenue Mooresville, NC 115 Re: Charlotte Latin School New Upper School Partial Certification for Permit 09952 To Whom It May Concern L Attached you will find the Partial Certification for the sanitary sewer relocation approved under Permit # I I I gg5 . This partial certification is for: 298 LF of -inch DIP Four (4) precast concrete-ranhoges Concurrent with this partial certification, Per WQ0039952 is being modified to include additional -inch DIP line and a -inch force main. The remainder of these lines will be certified when they are installed, Sincerely, Frank G. Miller, P.E. nci Development Services fmillercxlittleonlin m Phone:, 04- 1-7451