Loading...
HomeMy WebLinkAboutWQ0039909_Regional Office Historical File Pre 2018Water Resources FILE ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Environmental Quality Director April 13, 2018 Ms. Patricia Jones, Vice President and General Manager Carowinds, LLC 14523 Carowinds Blvd. Charlotte, NC 28273 Subject: Permit No. WQ0039909 Carowinds, LLC SpringHill Suites Charlotte at Carowinds Wastewater Collection System Extension Permit Mecklenburg County Dear Ms. Jones: In accordance with your application received April 9, 2018, we are forwarding herewith Permit No. WQ0039909 dated April 13, 2018, to Carowinds, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. ,"Nothing Compares. State of North Carolina I Environmental Quality [ Water Resources I Water Quality Regional Operations Mooresville Regional Office 1 610 East Center Avenue, Suite 30l I Mooresville. North Carolina 28115 704-663-1699 If you need additional Information concerning this matter, please contact Barry Love at (704) 235 or via e-mail at barry,love@ncdenr.gov. Sincerely, DocuSigned by: A14CC681 AF27425„, by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Jeff Oden, P.E. (e-copy) Barbara Gross (e-copy) Tommy Rowland (e-copy) Regional Office Files Water Resources. Central Files PERCS (esscopy) 4 2 I Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Carowinds, LLC Mecklenburg County for the construction and operation of a 0.01608 MGD pump station with duplex pumps, on -site audible and visual high water alarms, telemetry, and a permanent generator with automatic transfer switch; as well as approximately 913 linear feet of 2-inch force main to serve the SpringHill Suites Charlotte at Carowinds project, and the discharge of 16,080 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received April 9, 2018, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. —DocuSigned by: by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0039909 Permit Issued: April 13, 2018 SUPPLEMENT TO PERMIT COVER SHEET Carowinds, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NC0024970. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS 1. No flow in excess of the quantity permitted herein, 16,080 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between Carowinds, LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T,0304(h)] 3. Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single- family residence may have a placard or sticker on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2) II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 27; the Division's Gravity Sewer Minimum Design 'Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and -to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. 0- Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows, Right-of-ways and easements shall be rnaintairied in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the tacit ty incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence, This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part U of Form C5-S50 (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G,S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. f 15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. 6 A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T _0116) 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)1 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .01161 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North 7 Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104i 1SA NCAC 02T .01O8(b-c)] In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T__0110; 15A NCAC 02T M0108(b)j 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)1 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Carowinds, LLC WQ0039909 Springhill Suites Charlotte at Carowinds April 13, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 1, , as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe (n periodically, ❑ weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina 1 Environmental Quality' Water Resources 1 Water Quality Regional Operations Mooresville Regional Office' 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 LETTER OF TRANSMITTAL STE ART T° NCDEQ- Division of Water Resources 610 E. Center Avenue Mooresville, NC 28115 704.663.1699 DATE PROJECT NUMBER X17017 COPIES DATE SENT VIA PROJECT NAME FR(!taO David Starkel, PE Civil Project. Engineer II dstarkel@stewartinc.com 704.909.3513 SpringHull Suites Charlotte at Carowinds DESCRIPTION 04 ©6 11I Cover Letter 4_3-23-18Application Fee - $480.00 i T 03-30-18 I Fast Track Application Form(FTA 04-16) _( 03-16 18 ; Charlotte Water Capacity Assurance Letter 1_03-27 18 Flow Tracking/Acceptance Form (FrSE 04 1.6) 04-06-18 i Site Map_ 04 06 18 ; Street Level Mail C�3-2Q 18 Site Utility Plan For approval For your use As requested COMMENTS For review & comment Approved as noted betas/5 r*R 4 p41/v4? (©ear +M4114. David Starkel Returned for corrections Resubmit copies for approval APP.rCnaN COPIED TO File RONGER DESEG N 101 N. TRYON ST, SUITE 1400 CHARLOTTE,. NC T 704,334,7925 28202 704,334,7926 STEWART April 6, 2018 NCDEQ - Division on Water Resources 610 East Center Avenue Mooresville, NC 28115 Re; SpringHill Suites Charlotte at Carowinds Fast Track Application (FTA 04-16) Stewart Project Number: X17017 To whom it may concern, Please find the Fast Track Application for the referenced project enclosed. The applicant is requesting a permit from the Division of Water Resources to extend a sewer system pursuant to G.S. 1.43-215.1. The project includes the construction of a private sanitary sewer extension to serve a new 130-room hotel, including a new duplex pump station and approximately 913 linear feet of 2" force main piping. The pump station will combine effluent from two laterals from the hotel building and an exterior pool. Approximately 85 linear feet of 8" gravity sewer lateral from the hotel building and 367 linear feet of 4" gravity sewer lateral from the pool will be routed to the pump station. The proposed force main will tie into an existing private force main located on -site and will eventually discharge to a private on -site gravity wastewater collection system. The existing private wastewater collection system eventually discharges into the public wastewater collection system operated by Charlotte Water, The private system will be owned, operated, and maintained by Carowinds, LLC. The wastewater discharged from the hotel and ultimately treated by the wastewater treatment facility (WWTP NC0024970) will be 100% domestic type waste. Proposed Average Daily Design Flow from Hotel: Office: 8 employees x 25 GPD/employee Pool: 28 persons x 10 GPD/person Hotel 30 rooms x 120 P© room Total Please contact me with any comments or questions a Sincerely, Jeff ©den, PE Enclosed; Check in the amount of $480,00 Fast Track Application Form (FTA 04-16) Charlotte Water Capacity Assurance Letter Flow Tracking/Acceptance letter (FTSE 04-16) Site Map Street Level Map Site Utility Plan (Sheet C600) = 200 GPD 280 GPD = 5a00 GPD 16,©80 GPD 704)909-3506. 'SIR av 101 NORTH TRYON ST, SUITE 1400 CHARLOTTE, NC 28202 T '7O4,334,7925 F 704.334,7926 State of North Carolina Depart tatertt of Environmental Quality Division of Water Resources 'AC 02T .0300 — FAST TRACK SEWER SYSTEM ;EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: ,,tAt VR) All items must be completed or the application will be returned APPLICANT INFORMA'I'ION: I. Applicant's name: ("arm', APP ype: Signature attthority`s tt:tnte: Pat Title: Vice President and General Manager Applicant's. mailing address: 145.23 Carow Inds Blvd City: Charlotte State NC Iola. 2+127+- Applicit's contact tnl€ rtta ttttrri: Phone number: (704) 58K_2601.) hmail Address: *any, mu porution 'County Partnership cipal tat IL PROJECT INFORMATION: 1. Project name Sprit:10101 Suites Ch:)tl'tt at Carowinits 2. Application/Project status: Proposed (New Pcrriitt) F:x sting Perntitrl lfa modification, promde. the existing permit number: WQ00 and issued date:.. construction but part of a master plan, provide the eristin 3. ("minty where project is located: Mecklenbu 4. Approximate Coordinates (Decimal I)egrec s 5. Parcel ID (if applicable): 20317102 (or Parcel ID to closest downstream sewer} I11 CONSULTANT INFORMATION: I. Prot 1059' eff(den l.,icense Number: NC13328 Firm.: Stewart Erin,tteertna Mailing address: II f} I N. Tryon Street, Suite 1400 City: Charlotte State: NC:" Phone: *teen Cher: (704) 334-792 Zip: 28202--.... I tttail e (&clreti e is~d number: WQOO c. n '4'ASTEWATER TREATMENT FACIL,F) INFORMATION; I. Facility Name: McAlpine Creek WWII' Permit Number: NC.'0024970 Owner Name: C:harlctte t''ater V, RECEIVING DOWNSTREAM SEWER INFORMATION (if different than 1VWTF): 1. Permit Number(s): WQro_ .System Wide Collection Owrraer Name(s): Downstream, (Receiving) Sewer Size it Number(~'JIt `„ p ➢ieablrl: V QCS FORM: Fi 04-16 .VI. GENERAL REQUIREMENTS 1. lithe Applicant is a Privately -Owned Public Utility. has a Certificate of Public Convenience and Necessity been attached? 0 Yes ONo NIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's 0 ...era .i-, al AgreementArejnt (1'ORM. DENO been attached? 0 Yes DNo NIA 3. If the Applicant is a Home/Property_Owners" Association,has an Operational Ag,reement (FORM: .F1(1).A), been attached? 0 Yes LJNo NIA 4. Origin of was•tewater: (check all that apply): LI Residential Owned Residential Leased Ej. School / preschool day care 0 Food and drink facilities. Businesses / offices factories 0 Retail (stores, centers, malls) 0 Retail with food preparationlserice 0 Medical / dental veterinaryfacilities 0 Church Nursing Home 5. Nature of wastewater : 100 % Domestic/Co•mmercial % Commercial o Industrial (See 15A NCAC 02T .0103c0J) there a Pretreatment Program in effect? 6. Has a flow reduction been approved. under 15A NCAC 02`f .0114(D? Yes If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02 l'.0114(0) Office Pool Hotel Daily Design Flow 25 gal/employee 10 gallperson 120 Ballroom 0 Car Wash, Hotel andlor Motels 0 Swimming Pool /Clubhouse ii Swimming Pool/Filter Backwash 0 Other (Explain in Attachment) Yes LJNo No No. of Units Flow 200 GPD 280 GPD 15600 GPI) GP[) GPD Total 16080 GPD a See 15A NCAC 02T 14(b),,:(4) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i,e, minimum flow per dwelling; proposed unknown :non-residential development uses: public access facilities located near high public use area; and residential property located. south or east of the Atlantic Intracoastal Waterway to be used as vacation rentalsas defined in G,S, 42A-4), b Per 15A NCAC 02T ,0114(c), design •flow rates for establishments not identified [in table 1.5A NCAC 021-.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: -1.6080 GPD (per 15A. NCAC ,0114) ‘.1.: Do not •include future flows or previously permitted allocations If permitted flow is zero, indicate why: 0 Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line Flow has already been allocated in Permit Number: 0 Rehabilitation or replacement of existing sewer with. no new flow expected 0 Other (Explain): FORM: FTA 04-16 Page 2 of 5 +[ RAi 1`I" `` SE k`ER [DESIGN CRITERIA (lf rtl,pplicahle) - 02T .0305 & 14'I1)C JCravitv ! e►re 1. Summari o he pernutted: Size (inches) Length (Feet) Material r Section 11 & 111 attic MDC:' for Permitting c fCiravity Se ers ca ntaitas inf rmation related to design crite.ri Section Ill contains information related to minimttrrn slopes f`i OversiLing litres tro meet minimum slope requis not 11owsed and a violation of the Iw1DC ''Ili. PUMP STATICiN DESIGN CRITERIA (11 Applicable) \1DC (Pump Stations/Force Mains : COMPLETE FOR EACH PUMP STATION INC:LL=IDEID iN THIS PiO,IECT 1. Pump station number or name: Springhill Suites Charlotte at ds Approximate (Ty'oordinate Decimal Degrees): Latitude: 3 w1059'' 1,ongitude. ' -80.) 3 l9 5'' pp ( 3. Design flow of the pump station: 0,01608 millions gallons per day (kirnn capacity) 4, Operational point(s) of the pump(;): gallatt s pe.r minute at 91 1 dynamic Iteacl ('11)I1) 5, Summarize the force main to be permitted (lor this Pump Station): 6. Power re Length (feet) S.AN{,°AC f)2'1 .0305:lI(11' Standby power source or pump with automatic activation and telemetry - 15A NCAC 02i` _0305(h)(1)(By Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must he permanent to facility Or if the pump station has an average d 15.000 gallons per day: El Portable power source with manual activatatan, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or Portable~. pumping unit with plugged eiraergency pump co'nne.ct etry - 15A NCn'AC' 02T .0305 h It, shall he demonstrated to the 1Divisiasts that the portable source is owned or contracted by the applicant (drat agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, taut evaluation of all the pump stations" storage capacities and the rotation schedule of the portable power source or pump, including travel time:frarncs, shall be provided in the case of a multiple station power outage. FORM 1'°7`A 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I, Does the project: comply with all separations found in I 5A 'NCAC 02T ,0305(1) & (g) 15A NCAC 02T.0305(1, contains minimum se ..arations that shall be ,„ rovided for se' Setback Parameter* 'Storm sewers and other utilities :not listed below:(vertical Water mains (vertical -water over sewer including in benched trenches) Water mains (horizontal) .Reclaimed :water lines (vertical - reclaimed over sewer) .Reclaimed water lines (horizontal - reclaimed over sewer) Yes1 INo S:. **Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class II impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, SA, ORW. HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX 2) **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Any building foundation Any basement Top slope of embankment or cuts of 2 feet or more vertical height Drainage systems and interceptor drains Any swimming, pools Finaleahgradcveic Separation Required 24 inches 18 inches 10 feet 18 inches 2 feet 100 feet 50 feet 10 feet 5 feet (0 feet 10 feet 5 feet .10 feet 36inches 15A NCAC 02T,0305(g) contains alternatives where separations in 02T,0305(t) cannot he achieved. **Stream classifications can be identified using the Division's NC Surface Water ClaSsifications webpage If noncompliance with 0.21.0305() or (g), see Section X of this application .7. Does the project comply with separation rcqutrcmcnts. for wetlands? (50 feet of separation) Li Yes 0 No N/A See the Division's draft separation requirements for situations where separation cannot be meet >: No variance is required.if the alternative design criteria specified is utilized in design. and construction .> As built documents should reference the location ofareas effected 3. Does the project comply with setbacks found in the river basin rules per I.5.A NCAC 02B 0200' Yes L1i No N/A This would include Trout Buffered Streams per I 5A. NCAC 213.020.2 4. Does the project require coveragc/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications'? Information can be obtained from the 401 & Buffer Permitting Branch .Yes No 5. Does project comply with I5A NCAC 02T,0105(40 (additional permitsicertifications)? Yes LJ No Per I 5A NCAC 0217.0105(c)(6)., directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained, Issuance of this permit is contingent on issuance of dependent pennits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15.A .NCAC 0210402, "high. -priority sewer" :means any aerial sewer, sewer contacting surface waters, siphon, or sewer ,positioned parallel to strcambanks that is subject to erosion that undermines or deteriorates the sewer. ED Yes, No NIA If yes, include an attachment with details for each line, including type (aerial line, size, material., and loc.ation). High priority lines shall be inspected by the permittee or its representative. at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the pernnitee's individual System -Wide Collection permit. FORM FTA 04-16 Page 4 of 5 X. CERTIFICATION'S: Does the submitted system comply with 1 5A NCAC 02T, the Minimum Design Criteria for the Permitting of PuimiStations,, and Force Mains (late,st v:ersion), and the (jravity Sewer Minima:1m. ,Design Criteria (latest version) as applicable? PiiYes DNo If No, complete and submit the Variance/Altemative Design Request application (V ADC 10-14) and supporting documents for review, !Approval ofthe request is required prior Jo submittal of the Fast Track.Applicution anti supporting devout its, 2. Professional Engineer's Certification: 1, -p • obeN _ pE attest that this application for (Professional Engineer's 4iame from Application Item 111. I.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my !signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, NOTE - In accordance with General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000, as well as civil penalties up to S25,000 per violation, North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per I5A NCAC 02T „CH 06(b): 1, „Ar....___aQ‘7YALE!_egia5tOfejr Ceifiggeft4k_eatest that this application for (Signature Authority's name & title frorn Application Item 1,3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated, I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete, NOTE — In accordance with General Statutes 143-215.6A and 143-215613, any person who knowingly makes any false statement, representation e cat,jiany application pa age shall be guilty of a Class 2 misdemeanor, which may include a tine not to ex ed 09wefl as civiLpa1ti$to$25,000 per violation, Signature: Date: FORM: FTA 04- I 6 Page 5 of 5 CHARLOTTE W TER March 16, 2018 Mr. David Starkel Stewart Engineering, Inc. 101 N. Tryon Street Ste.1400 Charlotte, NC 28202 SUBJECT: CAPACITY ASSURANCE REVIEW CAROWINDS SPRINGHILL SUITES HOTEL 14500 BEST DAY BLVD, CHARLOTTE NC CLTWATER TRACKING# 2018297 A Capacity Assurance Review of the subject site has been completed and the following has been determined: After an analysis of the sanitary sewer associated with the proposed design of project 2018297, Carowinds Springhill Suites Hotel, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 16,080 gallons per day (8 emp x 25 gal/emp;28 persons x 10 gpd/person;130 rooms x 120 gpd/room) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. CLTWater agrees io furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained and construction has not started within one (2) year of issuance of this Capacity Assurance Review, and payment for any service connection(s) has not been received within (2) year of issuance of this Capacity Assurance Review letter, this approval shall be rescinded and a new Capacity Assurance Review must be made. If you have any questions, you may contact me at (704) 391-5138 or Justin Webster at (704) 336-3019. Sincerely, Vwenctrofyn 43anner Gwendolyn Banner Engineering Assistant Charlotte Water 5100 Brookshire NA, Charlotte, NC 282'16 charlottewater.org permed by the City of Charlotte Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Stewart Engineering, Inc . Project Name for which flow is being requested: Carowinds Springhill Suites hotel More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 10.797 64.791 0.016 75.588 77.0* H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Steele Creek 7.9 3.16 4.135 0.663 4.798 -1.638 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < D. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 2 FTSE 04-16 III. Certification Statement: I Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items Iisted above in Sections I and II plus all attached planning assessment addendums 'for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signin_ .9f icia ignature Date Page 2 of 2 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 13.8 % and 0.663 MGD of the Available Capacity (E) in Pump Station Steele Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.663 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Steele Creek LS Replacement is in design or under construction with planned Completion in Q4 - 2 618 ; and/or d. The following applies: The Steele Creek Pump Station replacement project will provide a new regional facility capable of handling build -out in the basin. Construction is expected to be complete by Q4 - 2018 Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. „39, Sign ingcial Signature Date Page3. FTSE 04-16 8" SANITARY SEWER LATERAL FROM HOTEL EXISTING 2°' FORCE MAIN PROPOSED PUMP STATION N35° 06' 21.OB" W80° 55' 53.48" 4" SANITARY SEWER LATERAL FROM POOL SPRINGHILL SUITES CHARLOTTE AT CAROWINDS SITE MAP egend Carowinds Amusement Park erovoada An u eme t Park K SE'it'ER ENGINEER CERTIFICATION PERMIiI`l"EE: Carowinds, LLC PERMIT #: WQ0O399O9 PROJECT: SpringHill Suites Charlotte at Carowinds ISSUE DATE: April 13, 2018 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this. Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMiTTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein.or portions thereof. P 3 FF OD .r4, PE a as ul egistered Professional En ineer in the State of North Carolina, having been authorized to observe ( periodically, [ weekly, En full time) the construction of the project name and location as refer e a bone for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such thatthe construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Diviision's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials.. North Carolina Professional Engineer's Seal w/signature & date: { Final D Partial {Include description) Certification Comments/Qualifiers (attach if necessary): Stair of North Carolina { Environmental Quality I Wier [%mum %ear u t R Maonassiite Ragiornl three! 1510 East Cent= Aw. Bade 30i 1 moms 704 661 1699