Loading...
HomeMy WebLinkAboutWQ0039415_Regional Office Historical File Pre 2018Water 1 esources Environmental Quality August 16, 2017 Mr. Mike Shea, Manager Shea Homes, LLC 8008 Corporate Center Drive, Suite 300 Charlotte, NC 28226 Subject: Permit No. WQ0039415 Shea Homes, LLC 36th Street Townhomes Wastewater Collection Syste Mecklenburg County Dear Mr. Shea:. ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Extension Permit In accordance with your application received August 11, 2017, and additional information received August 16, 2017, we are forwarding herewith Permit No. WQ0039415 dated August 16, 2017, to Shea Homes, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities,and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 1506 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Nothing Compares State of North Carolina l Env tr unental Quality p Water Resources i WaterQual' Regional Operations Mooresville Regional Office 161.0 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115 704 -663-1699 If you need additional information concerning this matter, please contact Lon Snider at (704) 235-2196 or via e-mail at |on.snider@ncdenr.gov. Sincerely, 4�--oE­bvVV.Corey Basinger, Regnna|8upen�sor Water [lua|ityBeghona|O�eradonsSectinn Mooresville Regional Office Division oyWater Resources, NCDEO cc: Brandon Plunkett, P.E.(-copy} Barbara Gross /e-cupy Tommy Rowland (e-copy Regional Office Files Water Resources Central Files PER[S(e'copy) 71 2 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Shea Homes, LLC Mecklenburg County for the construction and operation of approximately 319 linear feet of 8-inch gravity sewer, to serve the ,36th Street Townhomes project, and the discharge of 5,320 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the, application received August 11, 2017, and additional information received August 16, 2017, and inconformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000,.as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shallbe subject to the specified conditions and limitations contained therein. w(— by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division. of Water Resources, NCDEQ Permit Number: WQ0039415 Permit Issued: August 16, 2017 3 SUPPLEMENT TO PERMIT COVER SHEET Shea Homes, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water Sugar Creek Wastewater Treatment Plant in accordance with Permit Number NC0024937. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 5,320 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between Shea Homes, LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T.0304(h) ] II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4 I 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 • days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall bemaintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule fora minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919), 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part li of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [C.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification.. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension, Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated tomultiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T.0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be 7 I FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Shea Homes, LLC WQ0039415 36th Street Townhomes August 16, 2017 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title . Signature Date ENGINEER'S CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final n Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina 1 Environmental Quality 1 Water Resources 1 Water Quality Regional Operations Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: 4(5 (to Ix ,tompieted by DWR ) All items must be completed or he application vv ill be returned IL APPLICANT INFORMATION: 1. Applicant's name: Shea Homes (company, municipall 2. Applicant type. fl Individual Corporation 0 Federal E] state/county OA, utility, etc.) 0 General Partnership 0 Municipal 3. Signature authority's name: Mike Shea per 15, Title: manager. 4. Applic,a.nes mailing address:. 8008 Corporate,,Center Drive, Suite 300 City: Charlotte State: 'NC Zip: 28226- 5. Applicant's contact information: Phone number: (704) 602-3307 Email Address,: Mike.Shca@sheahornes.com 0 Privately -Owned Public Utility El Other rE,:E F DEN C D E R R OS M 0 0 R S vILLE REG K)NAL or R. c Ftt: IL PROJECT INFORMATION: 1, Project name: 36Street Townhomes 2. Application/Project status: Proposed (New Permit) 0 Existing Pen:nit/Project If a modification. provide the existing permit number: WQ00 and issued date: If construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenbu% Approximate Coordinates (Decimal. Degrees): Latitude. 35,241803' Longitude. - .798462' 5. Parcel ID (if applicable): 08316208 (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: 1. Professional Fiineer: Brandon Plunkett, PF Firm: McAdams Mailing address: 3436 TorimiikWaSuite 110 City Charlotte State: NC Phone number: (704) 521-0800 Email Address: plunkettgmcdarn5co„com 28277-__ License Number: 27475 IV. WASTEWATER TREATMENT FA LITY (WWII) INFORMATION: l. Facility Name: Sugar Creek Permit Number: NC0024937 Owner Name: Charlotte Water RECEIVING DOWNSTREAM SEWER INFORMATION (if different than 'WWTF): 1, Permit Number(s) : WQ Downstream (Re,ceiving) Sewer Size: inch SiyisitemiNithi Collection System Permit Noinbetkilitirutiplicablel: Owner Name(s): FORM: ETA 04-16. Page 1 of 5 % 1. GENERAL REQUIREMENTS If the Applicant is a Privately -Owned Public t_.=tilit , has a Certificate of Pu a( )pry,©1k e;zrF¢s Yes No tf`the .A 'plic t is a Developer of lots to be sold, has a Developer': s tt c atie,n'►,l Agreement (FORM: OKM1)3 v been attar hz ❑ Yes No 1NIA if the Applicant is a llc}late.Prty. rty Association,h t astt) sutic�n rl 4eireemestt FORM: I. J been attached'' D Yes Origin of wastewater. Residential Owned ❑ Residential Leased ❑ School preschool; day care [] Food and drink facilities ri Businesses r offices ;' factories check all that apply): Retail (s'tores, centers, mails) Retad with food preparationise¢ vica ❑ Medical dental ,' veterinary laciliti ❑ Church. ❑II Nursing Horne 100 °-°i, Domestic Commercial otntttercial 0 Industrial (Ste 15 1 \C.l(. 02T .0 L L20)) there a Pretreatment Program in effect'' h. Has a Clow reduction been approved tinder 15 \ NCAC 02T 0114(1)'l ❑ Y Ifyes, provide a copy of flow reduction approval letter 7_ Summarize wastewater generated by project, Establishment Type (see 02T 0114(f)) I Residential„ Townhorne Daily Design Flow a 190 gallda. unit 28 ! 5,320 GP[) W ash tel andlor ?Motels Swirrtming Pool /CIu ❑ Swimming Pool }filter Backwash ❑ Other (Explain in Attach d? gal/ gall No. of1.1 .T. GPL) Two/ 5.: 20 GPD a See 15 1 NCAC 02'T .01 14Lb). (d). (e)(1) and fe)t t for caveats to wastewater design flow rates (i.c., m.mum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas, and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G,S. 42ry 1). b Per 15.E NCAC 02T .0114(4 design flow rates for establishments not identified [in table 15A NC hall be determined using available tow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 5,.320 GPD (per 15,A N't, U 021` m1 14) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or (ravity. Sewer where flow will be per in subsequent permits 'that connect to this line ❑ Flow has already been allocated in Permit Number; Rehabilitation or replacement of existing sewer wiflt no new flow expected Other (Explain): FIRM Page 2of5 I. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 I. Summarize gravity sewer to be permitted: v. Q«ROS Section 11. & III of the M.DC 'for Permitting of Gravity Sewers contains inforion related to design erneri. Section III contains inforrnatior related to min um slopes for gravity sewers Oversizing lines to meet minimum slope requirement is not allowed and a violation of theN1DC STATION DESIGN CRITERIA (If Applicable) - 02T .0305 & NI I)C (Pump Stations/Force COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude:_` 3. Design flow of the pump station: milk ns gallons per day (firm capacity) 4. Operational point(s) of the pump(s): .,, gallons per minute at teettotal dymamie head (TI7H) S. Summarize the force main to be permitted (for this Pump Station}: Power reliability in Length (feet) rdance with l , C CO?T .0 O5(h0(.I )_ El Standby power source or pump with automatic activation and telemetry - I _A NCAC 02T .0305 h 1)()3)y= Required for all pump stations with an average daily flow greater than or equal to i 5,000 gallons per day 7 Must be pemtanent to facility Or if the pump station has an average daily flow less than 15,000 ,gallons per day: [] Portable power source with manual activation, quick -connection receptacle and telemetry - 1 SA NCAC 02T ,0305(h)(I)(C) or M1I i,_ OFFICE Portable pumping unit with plugged emergency pump connection and telemetry - 1 S A NCAC 021' .0305(h)(I)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or putnp is dedicated to multiple pump stations. an evaluation of all the pump stations" storage capacities. and the rotation schedule of the portable power source or pump, including, travel timeframes, shall be provided in the case of a multiple station power outage, A 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS (0213 .0200 & 15A NCAC 02-1" .0305(1)): I, Does the project comply with all separations found in 15,A NCAQ0.211,41.10511&(0 5A NCAC 02T.0305(t) contains minimum separations that shall beprovided fo Setback Parameter* and other utilities not listed below (vertical) systems: 0 Yes 0 No Separation Required /4 inches rains (vertical -water over sewer including in benched trenches) ins (horizontal) claimed water lines erUcaI - reclaimed over 18 inches 10 feet Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class 11 irn ounded reservoirs used as a source of drinking water raters classified WS (except WS-1 or WS-V), B, SA, ORW, HOW, or SB from normal h water (or tide elevation) and wetlands (see item 1X.2) 18 inches 2feet 100 feet 50 feet *Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Any building foundation Any basement —op, slope of emba.n.k.ment or cuts of 2 feet or moreve stems and interce tor drains swimming pools Final earth grade (vertical) 10 feet 5 feet 10 feet 36 inches )`.. 15A NCAc 02T.0305(g) contains alternatives where separations in 02T.0305 Icannot be achieved. » **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage • If noncompliance with (12T031)5(1) or (e), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) Yes 0 No Ei N/A ')'0: See the Division's draft separation requirements for situations where separation cannot be meet Y No variance is required if the alternative design criteria specified is utilized in design and construction ▪ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 0213 ,0200? Yes 0 No 0 N/A )'0 This would include Trout Buffered Streams per 15A,N(AQ,21.1.0202 4, Does the project require coverage authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? )%0 Information can be obtained from the 401 & Buffer Permitting_Branch Yes 0 No 5. Dues project comply with )5A 1\,I,CA('O2T.0105(J(6) (additional permits/certifications)? D Yes No Per 15A, NCAC 02T.0105(c)(t), directly related environmental 'permits or certification applications are being prepared. have been applied for, or have been obtained. Issuanceof this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?'" Per I5A NCAC 02T.0402„ "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer, El Yes No E1NA If yes, include an attachment with details I'm each line, including type (aerial line, size, material, and location), High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(1)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 1 A NCAC 021, the Mininttynt Des jg Crit tt3 tsar the erarat Ling of Pinup Staherns and Force Mains,.(Iatest version),, and the t .Sewer Mtnnnum Design Criteria..(] ttest yr rsiot . as applicable? Yes D No If No, complete and submit the Variance/Alternative Design Request application (VADC I0-14) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track App•lica'tion and supportingd" • uments. Professional Engineer's Certification: (Professional Engineer's name from Application th ieation for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version), Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE -- In accordance with General Statutes '143-215.6A and '143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation, North Carolina Professional Engineer's seal, signature, and date: attest that this application for has been reviewed by me and is ac ura'te. and complete tea the best of my knowledge, 1 understand that if all required parts of this application arc not comp)etcd and that if all required supporting doeumcntatiou and attachments are not included, this application package is subject to being rcturnetl as incornplece. ! understand that any discharge of Wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action drat may include civil penalties, injunctive relict, andlor criminal prosecution, 1 will make no claim against the Division of Water Resources should a condition of this permit be violated, 1 also understand that if all required parts of this application package are not completed. and that if all required supporting information and attachments are not included, this application package will he returned to me as incomplete. NOTE In accordance with General Statutes I43�21 . and 14 3-''2 1 5,6B, any person who knowingly makes any false statement, representation,, or certification in any application package shalt be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000 as well civil penalties up to $25,000 per violation, Signature: Date: FORM; FTA 04-16 Page 5 of 5 CHARLOTTE Wt.TER June 27, 2017 Mr, Matt Kearns Shea Homes 8008 Corporate Center Dr Suite 300 Charlotte, NC 28226 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE 36TH STREET TOWNHOMES 1122 E 36TH STREET, CHARLOTTE NC CLTWATER TRACK1NG# 201'7712 After an analysis of the sanitary sewer system associated with the proposed design of project 36'h Street Townhomes, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 5,320 gallons per day (28 townhome units x 190 god/unit) at the connection point(s) indicated on the submitted utility plan for transmission to the Sugar Creek Wastewater Treatment Plant: NPDES permit number NC0024937, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works Please see attached NC DEQ flow tracking form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NC DEQ However„ CLTWater cannot guarantee a constant pressure or quality of flow. CLTWater does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies arid continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved, Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to constructionif the appropriate authorization to construct permits are not obtained and construction has notstarted within one 1 ear of issuance of this flow acceptance, and payment for any service ccnnection(s2 have not been received within (1) year of issuance of this flow acce tance, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, ,( Barbara Gross Engineering Assistant Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewaterorg operated tly the City of Challotte 0 1,000 2,000 4,00,0 \. /I. 1 Feet inch 2,k )1) Fect X\" 36TH STREET USGS TOPO MAP PROJECT #: SHH-17000 CHARLOTTE, NORTH CAROLINA VICINITY MAP The John R. McAdams Company, Inc. Raleigh r Durham, NC 2905 Meridian Parkway Durrham,North Carohna 27713. (919) 361-5000 Charlotte, NC 3436 Toringdon Way Su to 110 Cwrlotte, North Caraldna 28277 (704) 527-OBOO CADAMS August 10, 2017 NCDEQ Mooresville Regional Office Water Quality Section. 610 E. Center Avenue Mooresville, North Carolina 281 1 Re: Fast -Track Application FTA 04-16 For Sewer 366 Street Townhomes Charlotte, North Carolina SHH-17000 Water Resources Department. Please find enclosed with this application the following attachments: 1, Application Forrn (FTA 04-16) 2, Application Fee 3, Flow Tracking/Acceptance for Sewer Extension Permit Forth (FaTSE 08-13) 4. Site Maps -USGS Topographic Map -Street Level Map The proposed water distribution system provides water service for domestic. and irrigation applications to serve a single-family attached development that include 28 residential units, The system consists of approximately 373 If of 2" private domestic service line and two 2" reduced pressure principle backflow preventers at each domestic connection to the public lines. The system will be connected to Charlotte Water and connections will be made to the existing 8" water main located within E 36th St. and to the existing 20" water man located within Holt St. The proposed sanitary sewer system will provide sanitary sewer service for each residential unit. The system will include 5 manholes and approximately 319 If of 8" PVC private sanitary sewer. The private service will be tied into the existing 8" sanitary sewer located within E 36th St, Sincerely, THE JOHN R. MC ADAFS COMPANt, INC. Brandon. Plunkett, PE Sr. Project Manager Enclosures McAdamsCo.com Designing Tomorrow's �!!nlrastru tr re Common!I,e'es Corporations Division Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE Po Box 29622 Raleigh,NC 27626-0622 (919)514-5400 Click Here To: View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Account Login Create Site Account Legal: SHEA HOMES L.L.C. Limited Liability Company Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: Registered Agent: Corporate Addresses 0348160 Dissolved Not Applicable Domestic 7/1/1994 December Farmer, Woodard , Jr. Reg Office: Reg Mailing: Mailing: Principal Office: 401 South Tryon Street, Ste. 3000 Charlotte, NC 28202 401 South Tryon Street, Ste. 3000 Charlotte, NC 28202 655 Brea Canyon Road Walnut, CA 91789 655 Brea Canyon Road Walnut, CA 91789 Company Officials Ail LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Manager: John F Shea , Jr 8008 Corporate Center Drive Suite 300 Charlotte NC 28226 https://www.sosnc.gov/Search/profcorp/4720340 8/14/2017 Central Files: APS SWP _ 8/16/2017 Permit Number WQ0039415 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 5,320 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name 36th Street Townhomes Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Shea Homes Non -Government Owner Affiliation Douglas I. Lawrie Dev Dir of 3436 Toringdon Way Dates/Events Charlotte NC 28277 Orig Issue 8/16/2017 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/11/2017 8/16/2017 8/16/2017 Regulated Activities Requested !Received Events Subdivision Wastewater collection Outfall Additional information requested 8/15/17 Additional information received 8116117 Waterbody Name Streamlndex Number Current Class Subbasin