Loading...
HomeMy WebLinkAboutWQ0038862_Regional Office Historical File Pre 2018Water Resources ENVIRONMENTAL QUALITY November 29, 2016 Robert T. Drakeford, Manager The Drakeford Company, LLC 1914 Brunswick Avenue Charlotte, NC 28207 PAT M:RORY Gov mor DONALD R. VAN DER VAART Secri a y S. JAY ZIMMERMAN it mr Subject: Permit No. WQ0038862 The Drakeford Company, LLC The Mews at Morningside Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Drakeford: In accordance with your application received November 14, 2016 and additional information received November 21, 2016, we are forwarding herewith Permit No. WQ0038862 dated November 29, 2016, to The Drakeford Company, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved, Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. al Quality I Water Resources I Water Quality Regional operations et ntea Avenue, Suite 301 Mooresville, North Carolina 28115 704 663 1699 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. Sincerely, e-V1r byW. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Christopher Fleck, P.E. (e-copy) Barbara Gross (e-copy) Tommy Rowland (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) Page 2 of 9 • Environmental • •, Quality • . WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina -as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to The Drakeford Company, LLC Mecklenburg County for the construction and operation of approximately 195 linear feet of 6-inch gravity.,sewer and 28 linear feet of 8-inch gravity sewer; a 0.00247 million gallon per 'day pump station with 14 gpm@12.1' TDH operational point, as well as 230 linear feet of 1.5-inch force main to serve 13 townhome units as part of The Mews at Morningside Sanitary Sewer project, and the discharge of 2,470 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received November 14, 2016 and.additionaI information received November 21, 2016:and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria, adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting •of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and ,considered a part of this permit. This permit shall be effective from the date of issuance until rescinded.and shall be subject to the specified co ition n • limitations contained therein. fin. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section . Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0038862 Permit Issued: November 29, 2016 Page 3 of 9 SUPPLEMENT TO PERMIT COVER SHEET The Drakeford Company, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water Sugar Creek Wastewater Treatment Plant in accordance with Permit Number NC0024937. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 2,470 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between The Drakeford Company, LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T.0304(h)1 Each pump station shall be clearly and conspicuously posted using a weatherproof sign with a pump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. Simplex pump stations or vacuum sewer pits serving a single- family residence may have a placard or sticker on the control panel in lieu of a sign. [15A NCAC 02T .0305(h)(2)] 4. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. [15A NCAC 02T.0115] i1. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)1 Page 4 of 9 2.- This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February.12, 1996, as applicable; the Division's Minimum Design Criteria for -the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 027.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall • be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. 'For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. Page 5 of 9 j. 3. Grease education materials shall be distributed more often than required in Parts (1) and of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. Right-of-ways,andeayementsshaUbamaintaiomdintbeful\eascmentvvkdthfonperm»nna|and equipment accessibility. Documentation shall bekept for Subparagraphs (a) through (i)nfthis Rule for aminimum ofthree years with exception of the map, which shall be maintained for the life of the system. G. The Permittee shall report by telephone toawater resources staff member at the Mooresville Regional Office, telephone number (7Q4)663'1699^assoon aspossible, but innocase more than 24, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known, or unknown reasons, that renders the facility incapable nfadequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.;or b. Any 3SOand/or spill over l,O0Qgallons; or c. Any 5SOand/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858~0368 or(3l9)733'33Q0. Persons reporting any ofthe above occurrences shall file aspill report 6ycompleting and submitting Part | of Form CS -SS[) (or the most current Division approved form) within five days following first knowledge ofthe occurrence. This report must outline the actions taken o,proposed tobetaken to ensure that the pr#b�iwrndoes, not recur. Part ||ofForm CS-5SC](or the most current Division approved form) can also becompleted 10show that the SSDwas beyond control. [G.5.l43-21S.1C(a1)] G. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters efthe State. [15ANCACOZT.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided onthe form. Acomplete certification isone where the form io fully executed and the supporting documents are provided asapplicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, 0fthe permit hoissued twaprivate entity with amOperational Agreement, then acopy uf the Articles of incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. Acomplete certification is one where the form isfully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan& profile views of sewer lines& force mains) ofthe wastewater collection system extension. Final record drawing's should be clear on Page 6 of 9 I the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, -, separation distances, material changes, etc. b. One. copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the .rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged, by the Division and may not be approved, thus requiring. replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. if there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)1 9. .A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in -accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)1 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] Page 7 of 9 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G,S. 143- 215.1(b)1 Page 8 of 9 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: The Drakeford Company, LLC WQ0038862 The Mews at Morningside November 29, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required -documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and -shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. - Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 1, • , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (1-1 periodically, 0 weekly, [] full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the - Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains.adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: El Final [] Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I WaterResources I Water Quality Regional Operations Mooresville Regional Of icel 610 Fast Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 ti . STATE OF NORTH CAROLINA COUNTY OF Permit No. 1 `/ 6d03,s'e.. OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this (p day 1 QV i6 A, Zed & , by and between the North Carolina Environmental Management Commission, .an _ agency of the State of North Carolina, hereinafter known as the COMMISSION; and S "ERM q 04A LLB° , , a corporation/general partnership registered/licensed to do business in tTie State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: of 1. The DEVELOPER is the owner of the certain lands lying in WI eekt§44 County, upon which it is erecting and will erect dwelling units and other improvements, said dev-opment to be known as (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the (Unit Owners' Association) (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The. DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 01-15 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element, which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. a, The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. hi the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System. the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and. Bylaws shall provide that such special assessments can be made as necessary at any time. r If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town„ village, county, water and sewer authorities, or other unit of government shall hereinafter becorne available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater, 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is tiled and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: ./ FOR THE ENVIRONMENTAL N.A EMENT COMMISSION S. Jay irntnerman, Director Division of Water Resource (Date Name of DEVELOP By: (Signature) FORM: DEV 01-15 Page 2 of State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: G � {tc�beoernplered by DWRa All items must be completed or the Hpptication will be returned APPLICANT INFORMATION: 1. Applicant's name: The Drakeford Company. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: 0 Individual Corporation 0 General Partnership 0 Privately -Owned Public Utility 0 Other 0 Federal 0 State/County 0 Municipal 3, Signature authority's name: Robert T. Drakeford per 15A NCAC 02T ,0106(b) Title: Manager 4. Applicant's mailing address: 1914 Brunswick Avenue City: Charlotte State: NC Zip: 28207- 5. Applicant's contact information: Phone number: (704) 344-0332 Email Address: bobbyAtdcrealestate.com 1.1. PROJECT INFORMATION: 1. Project name: The Mews at Morningside 2. Application/Project status: Proposed (New Permit) Q Existing Permit/Project If a modification, provide the existing permit number: WQOONA and issued date: NA If new construction but part of a master plan, provide the existing permit number: WQO0-0 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.13'07' 5. Parcel ID (if applicable): 129-022-34, 129-022-33, 129-022-32 (or Parcel ID to closest downstream sewer) Longitude:-80.48'04' III. CONSULTANT INFORMATION: 1. Professional Engineer: Christopher Fleck PE (Agent) License Number: NC #034556 Firm: ['3&A Wolverine PLLC Mailing address: 4136 Brownwood Lit NW City: Concord State: NC Zip: 28027- Phone number: (517) 404-6588 Email Address: chrisAdnawolverine.cam IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Suear Creek Permit Number: NC0024970-NC0024945-NC0024937 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Charlotte Water FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1- Iftle Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? El Yes 0No 1:4N/A. Ifthe Applicant i a eloper of lots to be sold, has a Developer's Operational Avrcement FORM,: MY) beets attached? e Applican Dev Ow 4. Origin of wastewater: (check all that apply): Residential Owned 0 Residential Leased 0lSchool / preschool /day care 0 Food and drink facilities El Businesses / offices . factories 5. Nature of wastewater 0 Yes No ON/A Tonal Agreement (FC Yes ONo 0N:r"A 0 Retail (stores, centers, malls) 0 Retail with food preparation/service 0 Medical / dental / veterinary facilities 0 Church Nursing Home een attached? 0 Car Wash 0 Hotel and/or Motels 0 Swimming Pool /Clubhouse Swimming Pool/Filter Backwash 0 Other (Explain in Attachment) 00 % Domestic/Commercial °'i, Commercial % Industrial (See 1.5A NC r C 0471.0103(20)) �ls there a Pretreatment Program in effect? 0 Yes 6. Has a flow reduction been approved under I SA NCAC 02T ,0114(1)? 0 Yes 1'f ves, provide a copy of flow reduction approval letter 7, Summarize wastewater generated by project: No Establishment Type (s Townhom Daily Design Flow °'h 190 gal/day gal/ No. of Units gal/ galr` gal/ gal/ Total Flow 2470 GPD GPD GPD GPD 2470 GPD GPD a See '15A NCAC 021' .01 l4(b), j ( 1 Lnd (e)(2) for caveats to wastewater des'gn flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities. located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4 ). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table i 5A NCAC 02T,0.1 14] shall be determined using, available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: 2470 GPD (per 15A NCAC 4) Do not include future flows or previously permitted allocations permitted flow is zero, indicate why: 0 Pump Station or Gravity Sewer where flow will be pertitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number: El Rehabilitation or replacement ofexisting sewer with ito new flow expected 0 Other (Explain): FORM: F'TA 04- .6 Page 2 of 5 VI .. GRAVITY SEWER DESIGN CRITERIA Applicable) - 02.1' .0305 & WC (Gtavkv Sewers: 1. Summarize gravity sewer to be permitted: • Section Il & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section 111 contains information related to minimum slopes for gravity sewer(s) • Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/For e Mains1:: CQMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I, Pump station number or name: PS -I 2 Approximate Coordinates. (Decimal. Degrees): Latitude: 35, 'Longitude.: -80,404' 3. Design flow of the pump station: 0,00247 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 14 gallons per minute at 12.1 feet total dynamic head (Trm) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) 1,5 Length (feet) Material 230 PVC 6, Power reliability in accordance with 15A NCAC 02T ,030501)(11: 0 Standby power source or pump with automatic activation and telemetry -15A NCAC 021' .0305(1 .'1)(B):. • 'Required for all pump stations with an average daily flow greater than or equal to 1.5,000 gallons per day • Must be permanent to facility Or if the pump station. has an average daily flow less than 15,000 gallons per day: Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T „0305(h)(1 )(C) Or Portable pumping unit with plugged emergency pump connection and telemetty - 15A NCAC 02T .0305(h)( I )(C): • It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. lfthe portable power source or pump is dedicated to multiple pump stations, an evaluation ()fall the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, :shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & I SA NCAC 02T .0305(l ): (. Does the project comply with all separations found in 15,A NCAC 0 T .0305(f) a :jaj. 15A NCAC 021 0305(f) contains minimum separations that shall be provided for sewer syste Setback Para 'to rm sewers and other utilities not listed b ar attains (vt r ater trains (hc Reclaimed wate is ate r ov including in vertical - reclaimed ove a hed trenches Reclaimed water lines (horizontal - reclaimed over sewer) *Any private or public water supply source, including any wells, lass II impounded reservoirs used as a source of drinking water S- aters of Class i or **Waters classified WS (except WS-I or WS-V'), B, SA, ORW, HOW, or SB from normal high water (or tide elevation) and ds ((see item 1X 2) **Any other stream, lak ditches poundment, or ground water lowea'itag a surface drainage Any build Any baseme To Drai ny undati ems and interceptor drains arch grade (verlica ion Eauired 24 inches 18 inches inche feet 0 50 feet Of 15A NCAC 02T.03contains alternatives where separations in Q2T.03055 **Stream classifications can be identified using the Division's NC Surface Water C"lssifications wehpage • If noncompliance with 02'T.Q305(f) or (g), see Section X of this application 5 feet: e 36 inches nnot be achieved, Does the project comply with separation requirements for wetlands? (50 feet of .separation) See the Division's draft separation requirements for situations where separation cannot be meet No variance is required ifthe alternative design criteria specified is utilized in design and construction >. As built documents should reference the location of areas effected p ject comply with all setbacks found in the river basin rules per 15A NCAC • This would include Trout Buffered Streams per 15A ivCAC 2I3.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? Wetland -related permits shall be requested, obtained, and adhered to for projects that impact. • Information can be obtained from the 401 & Buffer Permitting Branch Does project co ply with 15A NCAC 02"1°r0105(c)(6) (additional permits!'certifications)? No No No Yes No lands or surface waters Yes 1 I N Per I SA NCAC 1)2T.01 O5(r )(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). Does this project include any sewer collection lines that are deemed 'high -priority?" Per 15ANCACO2'1.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ©Yes �INo • If yes, include an attachment with details tzar each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or' its representative at leastonce every sixarnonths and ins documented per ISA NCAC O2T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-I6 Page 4 of 5 CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02"1 and Force Mains (latest version), and. the Gravity Sewer Minim as applic able'% Yes No If No, complete and submit the Variance,Alternative Design Request application (VADC4) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Apo! kat on and supporting documents Stations Professional .Engineer's Certification: (Professional Engineer`s name from Application I>esi n Criteria for the Pe attest that, this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge, 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my ° signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, NOTE — in accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. �;1 i 1111// j elkirt North Carolina. Professional Engineer's seal, signature, and date: ` n Applicant's Certification 1 SA t AC' d2T .0106(b p ;Signature ^° thority's natire title from Application ication for has been reviewed by me and is accurate and complete to the hest of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution, 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and thatif all required supporting information and attachments are not included, this application package will he returned to me as incomplete. NOTE In accordance with General Statutes 143-215.. and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date FORM: FT A 04-16 Page 5 of 5 CHARLOTTE W September 6, 2016 Mr. Sean Coldren D&A Wolverine, PLLC 550 E Westinghouse By Charlotte, NC 28273 TER SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE The Mews at Morningside 1509/1513 LYON CT, CHARLOTTE NC CLTWATER TRACKPNG# 2016904 A flow acceptance study of the subject site has been completed and the following has been determined: The review has been set to conditional due to capacity concerns at Permanent Flow Monitoring Sites 24 & 25. These capacity concerns should be addressed with the completion of the Briar Creek Relief Sewer project. All other associated sanitary sewer infrastructure was found to have sufficient capacity to accommodate the proposed sewer flow of 2,470 gallons per day (13 townhome units x 190 gpd/unit) from this project for transmission to the Sugar Creek Wastewater Treatment Plant; NPDES permit number NC0024937, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see the attached NC DEQ flow tracking form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NC DENR. However, CLTWater cannot guarantee a constant pressure or quality of flow. CLTWater does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. Charlotte Water 5100 Brookshire Blvd, C t tact , NC 28216 cR rottewater.arg ed by the City of Charlotte The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained and construction has not started within one 11) year of issuance of this flow acceptance; and payment for any service connection(s) have not been received within (1) year of issuance of this flow acceptance, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 391-5178, or Alan Gaines (704)-391-4689. Sincerely, Barbara Gross Engineering Assistant Charlotte Water 5100 Brookshire Eilvd, Charlotte, NC 28216 charlogewater,org Operated by the City of Charlott Division of Water resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: D&A wolverine, PLLC Project Name for which flow is being requested: Morningside Mews - Phase 11 More than one 1+ME may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg_ flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 11.286 71.262 0.00247 82.551 83.4% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP:. (A) (B) (C) (D)=(B+C) (E)—(A D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / p f), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not Iess than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Lyon Court Downstream Permit Number: unknown Page 1 of 6 FTSE 04-16 III. Certification Statement: I Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of„t is form indicates acceptance of this wastewater flow. Signing 6 a Signature Q��bi�lG Date Page 2 of 6 FTSE 04-16 Proposed 6" sewer e'er �xlting 3°' sewer n Lyon C to Sugar Creek Wastewate Treatment Plant NC8024937) FIRE HYDRANT LOCATION PLAN NOT TO SCALE 1., Wastewater Pump Station & Force Main Design Calculations North Carolina Department of Environmental Qua PROJECT NAME: The Mews at Mor ingside LOCATION: Charlotte, NC DATE: November 9, 2016 PROJECT #: 162012 DESIGNED BY: SMC CHECKED BY: CMF Y COMMITMENT * RESPONSIVENESS * PERFORMANCE % !W''WP,DNAWOLVERINE.COM 1. DESIGN SUMMARY A v e Project Name: Morningside Mews Phase II Townhomes Number of Units; 13 ly Flow Igpd . 2,470 arrr y How () r ).: 7.4 Pump Operati°nal Pent: 14 gpra 12,1 TD+H Pump Manufacturer : E/Gne Extreme Series Grinder Pump 1 hp 240 E/One WH483-92 Horse Yes Peguir'ed: Stahlin Enclosures Part No. RJ1816HPL. *Note: Include telemetry and portable generator connections. Force Mainimmetrwrr I n: 1,5 Force Man Lengtl ft)n 230 COMMITMENT * RESPONSIVENESS * PERFORMANCE WWW.DNAWOLVERINE.COM 2. FLOW CALCULATION Flos Cal s Establishment: Townhomes Unit Value: 190 Chario Unit: gpd Number of Units: 13 Average Daily Flow (gpd): 2,470 e ue er:nine Mintrnum Pump R t se h dicer ' rote °esmmit t m 2 nnethods) NCDEQ Peak Hourly How Method (P. S-FaM MDC °.f 2AA) Service Area Population (thousands): 0.052 Peak Factor: 4.3 18 + VP 4+SIP Design Peak Factor: 4.3 Average Daily Flow (gpd): 2,470 Peak Flow (gpd): 10,649 Minimum Pump Rate Required (gpm): 7.4 Pe :k Hours AssuP..nptie Peak Hours: 7 (6-9 AM & 5-9 PM) Percent of Average Daily Flow: 70% Flow during Peak Hours (gpd): 1729 Flow during Peak Hours (gph):. 247 Minimum Pump Rate Required (gpm): 4.1 Minimum Pump Rate Required (gpm): 7.4 Design Pump Rate (gpm): 14 COMMITMENT * RESPONSIVENESS* PERFORMANCE W WW,DNAWOVERINE.COM 3. CYCLE T)ME AND V ET WELL GEOMETRY De'iern ,s per Hour Average Daily Flow (gpm): 1.7 2,470 /1440 Design Pump Rate (gpm): 14 Time (min): 15.0 Cycles Per Hour: 4 Check Cycles Per Hour: OK V=TQtidf V = active volume with » the waa np station (gallons) T = allowable eyrie time between starts (minutes) Q40-= desigrz daily flow to pump station tailors per mini) O = paurrapirrg rater °fa single pump (gallons ear, minute) Required Volume (gal): 23 Pick Wet Well Diameter (ft): 4.0 See detail for E/One WH483-92 Pick Wet Well Cycle Depth (ft): 0.3 Volume in Cycle (gal): 31 If greater than required volume design then cycles is acceptable and C r t n Eievati n (E/One WH433..92) Top Elevation: 681.10 Ground Elevation: 681.00 Sanitary Sewer Invert In: 676.01 Bottom Invert Elevation: 673.44 Alarm: 675.60 Lag On: 675.26 Lead + 4" Lead On: 674.93 Pumps Off: 674.60 CO ENT * RESPONSIVENESS * PERFORMANCE WWW,DNAWOLVERINE.COM 4. FORCE MAIN AND PIPING DESIGN in Design Design Pump Rate (gpm): Select Force Main Size (in): Force Main Material: Velocity (fps) : 14 1.5 PVC 2.6 Meets Minimum Velocity Requirement? OK Meets Maximum Velocity Requirement? OK Line Length (ft): 230 Account for Minor Losses: 5% Equivalent Length (ft): 242 Pump Station Piping L)ato Wet Well & Valve Vault Pipe Size (in): 1.5 PVC Item Number of Fittings LSD Ratio Equivalent Length 45 bend 8 16 16 9© bend 22.5 bend Branch Tee Flow Check valve Plug Valve Q 30 9 0 60 8 135 17 17 Equivalent Fitting Length (ft): 40 Wet Well & Valve Vault Piping Length (ft): 20 Total Equivalent Pump Station Pipe Length (ft): 60 Equivalent off -Site Diameter Length (ft): 60 Total Equivalent Force Main Length (ft): 302 COMMITMENT * RESPONSIVENESS * PERFORMANCE WWW.DNAWOLVERINE.COM 5. PUMP SELECTION i esigr in ut Force Main Diameter (in): 1.5 Equiva)ent Force Main Length (ft): 302 Force Main Material: PVC Hazen -Williams C Factor: 120 Minimum Required Pump Rate (gpm): 7.4 Design Pumping Rate (gpm): 14 Wet Well Invert Elevation: 673.44 Force Main Discharge Elevation: 683.00 Static Head (ft): 9.56 Dynamic Head Calculation Design Pump Rate Required (gpm): Static Head (ft): Pump Station TDH (ft): 7.4 9.56 12.1 Pump Manufacturer: E,/One M odel: Extreme Series Grinder Pump See attached pump curve Horsepow r: Vo tage: 1 hp 240 COMMITMENT * RESPONSIVENESS * PERFORMANCE WWW.DNAWOLVERINE.COM 6. OPERATIONAL CHECK Oper ti n l Point No. 1 14 gpm 12.1 TDH Ct eck Wet Bi wle Times Wet Well Diameter (ft): 4 Wet Well Area (gal/VF): 94 Wet Well Cycle (ft): 0.33 Wet Well Volume (gal): 31 Fill Time (min): 18.3 Pump Run Time (min): 2.5 Total Time (min): 20.8 Number of Cycles: 2.9 Meets Cycle Time? OK COM T ENT * RESPONSIVENESS' PERFORMANCE WWW.DNAW©LVERINE.C©M 7. BUOYANCY CALCULATIONS E One WH483) yor Buoy 4 6 Station Height (ft): 92 Station Volume (ft3): 85.1 FnP, Buoyant (Ibs): 4,870 Tank Weight (Ibs): 440.0 FtmMast (Ibs): 5,802 Volume of Concrete (ft3): 10.1 Volume of Concrete (CY): 0.4 Weight of Concrete in Air (Ibs): 1,515.0 Min. Diameter of Concrete Anchor (in): 68.0 Min, Thickness of Concrete Anchor (in): 10.0 Depth to Bottom (in): 91.2 ncy Culations per Manua:. Mt .sr Re Buc yan Fbuoyont= Fbuoyant= Fnet-buoyant` F,net-buoyant=. 62.A x 85.1 5310 Ibs 5310 4870 Ibs 440.0 n .t&te Volume (ff33)- (0.83ft)(rr))(5.6 ft)2-(4.26 ft) )/4 Volume iff31 10.1 ft volume (ft "t)= (X ft Ct.83ft)()((5.6 ft)2-(4.26 ft)2)4 X=Depth to Bottom (ft) 7.6 Volume (ft )= 70.3 Cur ` is Ballast (tot Iasi (concrete) + Ballast (saturated soil) Ballast (total)----- Vsais (DensityConcrete in water)+VsatsADensity Sat Soil) Ballast (total)= 5802 ibs Find Cond'.tii n Final Condition= Ballast Force - Net Buoyant Force Final Condition-- 5802 4870 Final Condition= 931 lbs (Excess ballast) COMMITMENT * RESPONSIVENESS * PERFORMANCE WWW.DNAWOLVERINE.COM EIONE SPD PUMP PERFORMANCE CURVE TYPICAL OPERAT ING PRESSURE u-r TOTAL DYNAMIC MEAD 100 95 90 85 80 75 70 65 60 55 50 40 35 30 20 15 10 5 0 -10 -15 -20 -25 GRINDER PUMP, 1HP, 1725 RPM OW PRESSURE SYSTEM DESIGN PRESSURE CONSULT FACTORY FOR NTERMITTENT USE ABOVE 80 PSI OR 185 FEET TOH 0 2 4 6 8 10 12 14 16 18 DISCHARGE (0), GPM 2.30 22C) 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 -10 - 20 -30 -1-0 -50 - 60 0 LjJ LiJ LL z 0 a ESD 08-0022 REV. 2, 6/08 �c/Mid= S E FLI ES Patent Numbers: 5,752,315 5,562,254 5,439,180 * Discharge data includes loss through check valve, which is minimal. NA0214P01 Rev A 3/L7 Triplex Grinder Pump Station Features The WH483 or WR483 is a complete unit that includes: three grinder pumps with check valves, polyethylene tank and controls. The WH483 is the "hardwired," or "wired," model where a cable connects the motor controls to the level controls through watertight penetrations. The WR483 is the "radio frequency identification" (RFID), or "wireless," model that uses wireless technology to communicate between the level controls and the motor controls. All solids are ground into fine particles, allowing them to pass easily through the pumps, check valves, and small diameter pipe lines. Even objects that are not normally found in sewage, such as plastic, rubber, fiber, wood, etc. are ground into fine particles. The 1-1/4" inch discharge connections are adaptable to any piping materials, thereby allowing us to meet your local code requirements. The tank is made of tough corrosion -resistant polyethylene. Designed specifically for higher -flow applications where local codes dictate higher storage requirements, the WH483/WR483 has a tank capacity of 486 gallons (1840 liters), providing ample user storage. The lower portion of the tank has a smaller diameter tapered down to a dish shaped bottom. The large tank access opening easily accommodates installation of the grinder pumps and equipment. This model can handle flows of 5000 GPD (18,927 LPD). The internal check valve assemblies, located in the grinder pumps, are custom designed for non -clog, trouble - free operation. The grinder pumps are automatically activated and run infrequently for very short periods. Operational Information Motors 1 HP, 1,725 RPM, high torque, capacitor start, thermally protected, 120 or 240 V / 60 Hz, one phase Inlet Connections 4-inch inlet grommet standard for DWV pipe. Other inlet configurations available from the factory. Discharge Connections Pump discharge terminates in two, 1-1/4" female NPT connections. Can easily be adapted to 42 mm PVC pipe or any other material required by local codes. Discharge (per pump) * 15 gpm at 0 psig (.75 Ips at 0 m TDH) 11 gpm at 40 psig (.63 Ips at 20 m TDH) 7.8 gpm at 80 psig (.47 Ips at 42 m TDH) Overload Capacity The maximum pressure that the pump can generate is limited by the motor characteristics. The motor generates a pressure well below the rating of the piping and appurtenances. The automatic reset feature does not require manual operation following overload. STATION USES 1 DUPLEX MOD T260 .ALARM PANEL AND 1 SIMPLEX SENTRY ALARM PANEL COMBINATION CHECK VALVE / ANTI -SIPHON VALVE FLAPPER TYPE (NORYL) E/ONE EQUALIZER 1/3-2/3 SPLIT COVER W/HANDLE & PADLOCK STAPLE (ALUMINUM) ELECTRICAL QUICK DISCONNECT (EQD) NEMA 6P POLYETHYLENE MOLDED TANK 486 GAL (1840 L) QUICK DISCONNECT ASSEMBLY, PVC SLIDE FACE DISCHARGE FTG 1-1/4" FEMALE NPT, SS (X2) s 25.84" (656 mm) 17 84" (453 mm) 117 gal (443 L) 175 gal (662 L) 4 ALARIA 13.84" (352 mm) 89 gal (337 L) BACK-UP PUMP, ON A 4" (102 mm) PEDESTAL (PROVIDED BY OTHERS) 1 • 7.77 n1-117-1 SEMI -POSITIVE DISPLACEMENT TYPE PUMP DIRECTLY DRIVEN BY A 1 HP MOTOR CONCRETE BALLAST MAY BE REQUIRED SEE INSTALLATION INSTRUCTIONS FOR DETAILS WH 4 8 3 LEVELRCONTROLS) W R 4 8 3 LEVEL WIRELESS CONTROLS) TOP VIEW W/LID NOT SHOWN MUSHROOM VENT TANK ACCESSWAY SECTION (FIBERGLASS) POWER/ALARM CABLE (6 CONDUCTOR) DIRECT BURY CABLE CONNECTOR BULKHEAD FITTING NYLON LIFTING HARNESS DISCHARGE WYE MANIFOLD (SS) (X2) INLET, EPDM GROMMET TO ACCEPT 4.50" (114 mm) O.D. PVC PIPE (STANDARD). DUST COVER SUPPLIED FOR SHIPMENT (NOT SUITABLE FOR BURIAL) 1-1/4" (32 mm) FLEXIBLE DISCHARGE HOSE SG5 DR BY PD CHK'D 12/28/10 DATE A ISSUE 1/16 SCALE e SEWER SYSTEMS MODEL WH483 / WR483 DETAIL SHEET, TRIPLEX NOTE: DIMENSIONS ARE FOR REFERENCE ONLY NA0214P02 A 46.7" COVER OVER DISCH TYP 43 3" DISCH DISCHARGE: 1-1/4 NPT, SS (X2) CONCRETE BALLAST MAY BE REQUIRED SEE INSTALLATION INSTRUCTIONS FOR DETAILS W 1-1 4 8 3- 9 2 LEVELRDCONTROLS) W R 483 - 9 2 LEVEL RCONTROLS) GRADE MUST SLOPE AWAY FROM STATION 3.2" 60.4" INVERT DEPTH INLET: EPDM GROMMET FOR 4" DWV PIPE (STANDARD) SGS DR BY PD 02/10/11 CHK'D DATE 1/16 ISSUE SCALE e SEWER SYSTEMS MODEL WH483-92 / WR483-92 NOTE: DIMENSIONS ARE FOR REFERENCE ONLY NAO7 14PO4 DIAMETER CHOICES STATION TO BE USED WITH (1) M(1PANEL )�SENTTRY T260DSIMPLEX PANEL 1/3-2/3 HINGED ALUMINUM LOCKABLE LID TANK DISCHARGE SS DISCHARGE WYE DISCHARGE KIT FOR A SINGLE POINT DISCHARGE, 2 1-1/4" SS X HDPE WHIP 2 1-1/4" SS STREET ELBOWS (((1) 1-1/4" COMPRESSION TEE i TO MAIN INLET LOCATION VARIABLE 30` MIN (2) MAIN PUMPS RUN BY A MOD T260 DUPLEX PANEL MUSHROOM VENT (FACTORY DRILLED FIELD INSTALLED) BULKHEAD (FACTORY INSTALLED) CABLE CONNECTOR (FIELD INSTALLED) LIFTING ROPE (NYLON) SS DISCHARGE WYE 1-" FEMALE NPT (FACTORY INSTALLED) ANTI -SIPHON CHECK VALVE FIBERGLASS TANK WITH ANTI -FLOAT FLANGE (3) SEMI -POSITIVE DISPLACEMENT TYPE PUMP - DIRECTLY DRIVEN BY 1 HP MOTOR INLET CHOICES 4" DWV PIPE (4.50 OD) ❑ 4" DR35 PIPE (4.22 OD) ❑ 6" DWV PIPE (6.63 0D) ❑ 6" DR35 PIPE (6.28 OD) ❑ S5 DISCHARGE TANK DISCHARGE BACKUP PUMP, RUN BY A SIMPLEX PANEL ON A 4" BLOCK (BY OTHERS) E/ONE EQUALIZER ELECTRICAL QUICK DISCONNECT (EQD) n " 48 ❑ 60 ❑ W SERIES TRIPLEX STATIONS HEIGHT CHOICES "H" 60 66 72 78 84 90 96 102 108 114 120 126 132 138 144 COD RANGE 24 ) ❑ 24-30 ❑ 24-36 ❑ 24-42 ❑ 24-48 ❑ 24-54 ❑ 24-60 ❑ 24-66 ❑ 24-72 ❑ 24-78 ❑ 24-84 ❑ 24-90 ❑ 24-96 ❑ 24--102) ❑ 24-108 ❑ COVER OVER DISCH CHOICES "COD" 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ (DIMENSIONS SUPPLY CABLE 6 CONDUCTOR, TYPE TC DIRECT BURY CABLE "COY EPDM INLET GROMMET (FIELD INSTALLED) DISCHARGE SLIDE FACE QUICK DISCONNECT SS DISCHARGE HUB 7/..— 1-" FEMALE NPT (FACTORY INSTALLED) FLEXIBLE DISCHARGE HOSE 13' 102 gal SGS DR BY 25` 196 gal 17' 133 gal ARE IN INCHES) 'H` VOLUMES SHOWN ARE FOR 048 CHK'D 04/08/16 DATE ISSUE SEWER SYSTEMS 1/32 SCALE DETAIL SHEET W—SERIES TRIPLEX,SINGLE DISCH ESD 16-0028 i 31f�m0 MOM WM DI 710311 "1° -°4 NIIHVI3 aJ1: R7: glad [ow 7.d1!!! 101:1} I11=11:1E1 ream 71� Air 14 l 03/113210 DIONilla 13A ye A WON IMAM IICIYtl AWA karrO hOND 'R7 X► VIM 331131 IMAM 3➢MM7 Ol L3 WWX 9MIAW I T r8 v ,. 4 . EIONE RECOMMENDED BACKFILL UNDISTURBED EARTH CONCRETE BALLAST ANCHOR CONCRETE BENEATH TANK BASE (SEE SEC. 2) GRAVEL BEDDING 0 47.4" REF 0 68.0" MINIMUM BALLAST E/ONE RECOMMENDED BACKFILL (SOIL CONSIDERED CONTRIBUTING TO BALLAST) 10" MINIMUM BALLAST THICKNESS BALLAST INFORMATION 17 D&A WOLVERINE PLLC 550 E. WESTINGHOUSE BLVD, CHARLOTTE NC, 28273 TEL: 517,404.6588 WWW.DNAWOLVERINE. .-OM COMMITMENT * RESPONSIVENESS " PERFORMANCE November 16, 2016 MEMO: Section H Power Reliability Plan RE: The Mews at Morningside, Charlotte NC - Sanitary Sewer Application The 0rakeford Company, (Applicant/Developer) proposes to construct Thirteen (13) Townhome units for residential use on a parcel(s) 129-022-32, 129-022.-33, and 129-022-34 on Lyon Court in Charlotte, North Carolina. The system will utilize a lift station to pump sanitary effluent from the wet well to the existing system in the street. The applicant/developer and ultimately the property HOA acknowledge that in accordance with 15A NCAC 02T .0305(h)(1) a portable source of electric power (ie: generator) will be provided and kept onsite at all times for the specific purpose of providing standby power for the pump station in the event of a power outage. • The generator will be owned and maintained by the H©A. • The generator will have sufficient power to provide the necessary power as required to properly operate the pumps and the pump station. The pump station shall have appropriate electrical connections at the pump/station and or panel for the generator. e Received: Initial Revi by (ci: net I)E) RBK dd info Requ sted: Add info Receiv MEMO: Section H — Power Reliability Plan RE; The Mews at Morningside, Charlotte NC — Sanitary Sewer Application The Drakeford Company, (Applicant/Developer) proposes to construct Thirteen (13) Townhome units for residential use on a parcel(s) 129-022--32, 129-02.2-33, and 129-022-34 on Lyon Court in Charlotte, North Carolina. The system will utilize a Iift station to pump sanitary effluent from the wet well to the existing system in the street. The applicant/developer and ultimately the property HOA acknowledge that in accordance with 15A NCAC 02T .0305(h)(1) a portable source of electric power (le: generator) will be provided and kept onsite at all times for the specific purpose of providing standby power for the pump station in the event of a power outage.. • The generator will be owned and maintained by the HOA. • The generator will have sufficient power to provide the necessary power as required to properly operate the pumps and the pump station. • The pump station shall have appropriate electrical connections at the pump/station and or panel for the generator. r D&A WOLVERINE PLLC 550 E. WESTINGHOUSE BLVD. CHARLOTTE NC, 28273 TEL: 517.404.6588 WWW:L�NAVVOi.VERINE,COM COMMITMENT * RESPONSIVENESS* PERFORMANCE November 9, 2016 MEMO: RE: The Mews at Morningside, Charlotte NC — Sanitary Sewer Application The Drakeford Company, (Developer) proposes to construct Thirteen (13) Townhome units for residential use on a parcel(s) 129-Q22-32, 129-022-33, and 129-022-34 on Lyon Court in Charlotte, North Carolina. The development will consist of two (2) buildings of five (5) residential units and one (1) building of three (3) residential units for a total of 13 residential units. Each unit will have a 4" diameter PVC lateral with dean -out. 195 LF of 6" diameter' Sch. 40 PVC will serve as the gravity sanitary sewer collection system leading to a triplex grinder pump station internal to the property (See sheet C1.0). The 1.0 horsepower grinder pumps will discharge into 230 LF of 1.5" Sch. 40 PVC force .main. The 1.5" force main will discharge into a proposed manhole inside the public right-of- way. 28 LF of Sch. 40 PVC gravity sewer will connect this manhole to a proposed doghouse manhole at the existing 8" diameter Public Sanitary Sewer located along the center of Lyon Court. All construction will be in accordance with Charlotte Water standards and applicable building codes. Corporations Division Page 1 of 1 North Carolina Elaine F Marshall EPARTM ENT OF THE Secretary S E CRETARYO ' STATP PO Ba*, 29 '2 Rates , NC 271626—Da22 (9-M P,Q7-2 )0 Account Login The Secretary of State's Office will be closed on Friday, November 11 in observance of Veterangtegister Day. We will reopen at 8 a.m. on Monday, November 14. Click Here To: View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Legal: The Drakeford Company, LLC Limited Liability Company Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: State of Incorporation; Registered Agent: Corporate Addresses 0612367 Current -Active Current Domestic 12/6/2001 December NC Drakeford, Robert T. Mailing: Principal Office: Reg Office: Reg Mailing: 1914 Brunswick Ave Ste 1A Charlotte, NC 28207-1891 1914 Brunswick Ave Ste 1A Charlotte, NC 28207-1891 1914 Brunswick Ave Ste 1A Charlotte, NC 28207-1891 1914 Brunswick Ave Ste IA Charlotte, NC 28207-1891 Company Officials Ali LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Manager: Robert T Drakeford 1914 Brunswick Ave Ste 1A Charlotte NC 28207 https://www.sosne.gov/Search/profcorp/5395638 11/15/2016 Central Files: APS _ SWP 11/29/2016 Permit Number WQ0038862 Permit Tracking Slip Program Category Status Protect Type Non -discharge Active New Project Permit Type - Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions • 1.00 Individual Primary Reviewer barry.love Coastal SWRuie Permitted Flow 2,470 Facility Permit Contact Affiliation Facility Name Major/Minor Region The Mews at Momingside Minor Mooresville Location Address County Mecklenburg Facility Contact Affiliation Owner Owner Name The Drakeford Company Dates/Events Owner Type Non-Govemment Owner Affiliation Robert Drakeford 1914 Brunswick Ave Charlotte NC 28207 Orig Issue 11/29/2016 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective 11/14/2016 11/29/2016 11/29/2016 Regulated Activities Requested /Received Events Apartment complex Condominium Wastewater collection Outfall Expiration Additional information requested 11/15/16 Additional information received 11/21/16 Waterbody Name Streamindex Number Current Class Subbasin FAST TRACK SEWER ENatNEERING CERTIFI!4TION PERMITTEE: The Drakefe rd Company, LLC PERMIT ri: WQ0038862 PROJECT: The Mews at Morningside ISSUE DATE: November 29, 2016 WO R OS This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation, it should be submitted in a manner that documents the Division's receipts Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, The Permittee Is responsible for tracking ail partial certifications up until a final certification Is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PE'RMITTEE'S CERTIRCATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. nit er--4-' 0.„rkkeiLd Printed Name, Title fQt ure ENEttI+lEE3t'5 CERTIFKATION as a dui registered Professional E ineer in the State of North Carolina, teen authorized to observe ( periodically, weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of s, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials North Carolina Professional Engineer's Seal w/signature & date: vi Final Q Partial (indude dcrlpti©n) Certification Comments/Qualifiers (attach if rlec Stale or North Carolina I Mooresville Regional Off/eel61 ity Q Water Resources 1 Weser Quality Regional Operations ex Avenuc, Suitt 301 N Mooresw7le, North Carolina ni 13 7rr +Sd3 1699 9NE PLLC OKSHIRE BLVD. OTTE NC, 28216 704,494, 9776 ,UNAWOLVLRINE,CQY COMMITMENT * RESPCbNSIVENES. PERFORMANCE December 4, 2018 NCDEQ Mooresville Regional Office Attn: Mr. Barry Love 610 E. Center Avenue Suite 301 Mooresville, NC 28115 RE: The Me +r sat Morningside, Charlotte NC — Sanitary Sewer Permit #WQ0038862 Dear Sir: Please find the attached relative to final certification for the above referenced permit: • Signed & Sealed Fast Track Certification • Recorded HOA Documents & Operations Agreement • As -built drawing & survey • Copy of original permit application & calcs • USB drive of the above. Please let us know if any additional information is needed. Sincerely, D&A Wolverine PLLC Christopher M. Heck, PE Owner / Managing Member (O 704 785.9664 WQFROS