Loading...
HomeMy WebLinkAboutWQ0038731_Regional Office Historical File Pre 2018Water Resources ENVIRONMENTAL QUALITY September 22, 2016 Mike Wilson, Director of Development NR Stonewall Property Owner, LLC 1057 East Morehead Street, Suite 300 Charlotte, NC 28204 Ti MCCRORY lea i•._ _t vvemor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Dtrecmr Subject: Permit No. WQ0038731 NR Stonewall Property Owner, LLC Stonewall Mixed Use Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Wilson: In accordance with your application received September 14, 2016, we are forwarding herewith Permit No. WQ0038731 dated September 22, 2016, to NR Stonewall•Property Owner, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1506 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Of6cel 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 SUPPLEMENT TO PERMIT COVER SHEET NR Stonewall Property Owner, LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water Sugar Creek Wastewater Treatment Plant in accordance with Permit Number NC0024937. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 70,538 GPD shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T,0304(b)] 2, This permit shall become voidable unless the agreement between NR Stonewall Property Owner, LLC and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T.0304(h)] II. STANDARD CONDITIONS This permit is not transferable. in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-21.5.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T,0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the Page 4of8 I operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. J. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule fora minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due tnknown orunknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.;nr b. Any SSOand/or spill over 1,OOOgallons; or c. Any SSOand/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (8OQ)85Q'0388 or(919) 733-3380. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part | of Form CS-SSO (or the, most current Division approved form) within five days following first knowledge ofthe occurrence. This report must outline the actions taken orproposed tobetaken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also bocompleted toshow that the SSOwas beyond control. [G.S.143-21S.1[(a1)l G. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so an not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters ofthe State. [15ANCACO2T.0108(b)] 7. Upon completion ofconstruction and prior tooperation ofthese permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided onthe form. Acomplete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permi11ee to appropriate enforcement actions. |fthe permit lsissued toaprivate entity with amOperational Agreement, then acopy of the Articles of incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. Aconnp}ete certification isone where the form isfully executed, and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy ofthe project construction record drawings (plan & profile views ofsewer lines &force mains) ofthe wastewater collection system extension. Final record drawings should beclear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush \ovx points in force mains with e pump cycle, and downstream sewer capacity analysis. If portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the notation schedule of the portable power source or pump, include travel tirnefrmrnes,shall beprovided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: NR Stonewall Property Owner, LLC WQ0038731 Stonewall Mixed Use September 22, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I, , as a duly registered professional En ineer in the State of North Carolina, having been authorized to observe (E periodically, El weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: E Final C Parti include description) Certification Comments/Qualifiers (attach if necessary): Mate of North Carolina I Environmental Quality I Water Resources }Water Quality Regional Operations Mooresville Regional ©fficel 610 East Center Avenue, Suite 101 d Mooresville, North Carolina 28115 ^1ridi at 41 I4116 tvtslvn of Water Resources State of North ,Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 -. FAST TRACK SEWER S'STEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application. Number: VV Q o All manta gust be completed or the appkieati APPLICANT INFORMATION: be completed by DWR) be returned 1. Applicant's name: NR Stonewall Property Owner, LL4 (company, ni..cipality, HOA, utility, etc.) 2. Applicant type: Individual Corporation ❑ General Partnership Ei Privately -Owned Public [Utility © Federal ❑ State/County ❑ Municipal ❑ Other tiT.01 06(h) Si attire authority's name:: Mike Wils rt per Title: Director of Development Applicant's mailing address: 1057 East Morehead Street, Suite 300 City: Charlotte State: .NCLip: 25204- Applicant's contaet inl"orniation: Phone number: (704) 714-9682 Email Address: rxty ilsrrrt rrorthwood ll. PROJECT INFORMATION: I, Project name: Stcnevall 1 2. Application/Project status. 1'f anmodilication, provide the ea It'ne construction bin part of ed. Us Z Proposed (New Permit) ing permit number: WQ00 [ J F;xistisrg Pura it Project and issued date: stet° plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.219079' Longitude:-g0.g44590: 5. Parcel ID (if applicable): 12.517106 (or Parcel ID to closest downstream sewer) i11. CONSULTANT INFORMATION: I. Professional Engineer: Rob Keidel License Number: NC 37425 Firm: LandDesign, inc% Mailing address: 223 N. Graham Street City: Charlotte State: NC Zip: 28202- Phone number: (704) 333-0325 Email Address: rkeidelg anddesign.corn WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I, Facility Nance: Sugar„Creek WWII Permit Number: NC0024937 Owner Name: Charlotte Water RECEIVING :DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1_ Permit Numher(s): WQ System Wide Collection System Pen it Number(s) (iWQCS Owner Natne(s): Charlotte Water Downstream (Receiving) Sewer Sire: 24 inch FORM: FTA 04-I6 Page 1 of5 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE Asheville Regional Office ater Quality Section Fay Wale ADDRESS COUNTIES SERVED 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax vifle gional Office uaHty Section 225 Green Street Suite 714 Fayetteville, North Carolina 28301- 0 (910) 433-3300 (910) 486-0707 Fax aoresville Regional Office Water Quality Section Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland 610 E. Center Avenue Mooresville, North Caro ina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Raleigh Regional Othce Water Quality Section 1628 Mail Service Center Raleigh, North Carolina 27 28 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson hicdon Regional Office ter Quality Section 943 Washington Square Mali Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bente, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne mington Regional 0 I Quality Section ern Regional Office uality Section 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax 450 W. Hanes Mffl Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Brunswick, Carteret, Columbus, Duplin, New Hanover, Onsiow, Pander A affiance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin INSTRUCTIONS FOR FORM: FTA 04- `?4,. SUPPORTING DOCUMENTATION Page 3 04'3 VL GENERAL REQUIREMENTS ], Iftlte Applicant is a Privately -Owned Public 2. If the Applicant is a veloper of lots to be sold, If the Applicant is a 1 tt `'Propei ty Own ss' . 4, Origin ©fwastewater: 0 Residential Owned • Residential Leased School / preschool Food and drink lac Businesses / offices / factories da.y care t applr 0Yes sociation, ity, has a itcate of Public Convenience and Neces been attached? 0 Yes ©No ®N/A has a Developer' 7per tiranal Agreement (FORM: Dl/2I been attached'? No N/A 0 Yes No N/A El Retail (stores, cente Retail with food pre Q Medical / dental / ve Church Nursing Home Nature of wastewater : 1©0 % Domestic/Commercial '% Industria vice `.nar* faci % Commercial 15A NCAC 021 m0.103120)) is there a Pretreatment Programs in effect? 6, Has a flow reduction. beets approved unda r 15,E NCAC 0?'f.01 1_4(02 0 Yes If yes, provide a_e©py of flow reduction approval letter 7. Summarize wastewater generated by project: Yes No No blishrent. Type (see 0rT.01140)) Daily (Design Flow 'ached'? ash ;d/orMotels ing Pool /Clubhouse ing Pool Filter Backwash (Explain in Attachment) No. of Llrtits Flow Apartments 135 gal/day 435 58,725 GPD Amenity Retail 6955 gal/day l 108 gal/day 3750 gal/day 1 6,955 GPD 1,108 GPI) 3,750 GPD gal/ GPD gal/ (iPI) Total 70,5 a See 1,5A N (0 "1" 4)l 1'44.tn. (dp j. I"err caveats to wastewater design flow rates (i.e., ntintrrtum flow per dwelling; proposed unknown non-residential development uses;; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to he used as vacation rentals as defined in G.Sµ 42A-4), b Per 1.5A NCAC 02T .01.14('c), design flow rates for e„stablishnneits not identified [ in table 1. SA NCAC 02 ➢ .tall lit] shall be determined using available flow data, water using fimutes, occupancy or operation patterns, and other measured data, 8. Wastewater generated by project: 70,538 GPD (per 15A N( ..C:. o2 i .µ4 ]_)4) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: El Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. 0 Flow has already been allocated in Permit. Number: [] Rehabilitation or replacement of existing sewer with no new flow expected 0 Other (Explain): FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & Mi vSewers: I. Summarize gravity sewer to be permitted: Size • ches) , Length (f 10 180 Material PVC 'fo. Section 11 & IU of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section HI contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I, Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: ' Longitude: 3. Design flow of the pump station; millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5, Summarize the force main to be permitted (tor this Pump Station Size (inches) Length (feet) 6. Power reliability in accordance with 15 j\CAC 02T ,P305:. • . 0 Standby power source or pump with automatic activation and telemetry - 1.5A NCAC 02T .0.305(h)(1)(B) ';:o Required:for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day .Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: LI Portable power source with manual activation, quick -connection receptacle and telemetry - ISA NCAC 02T .0305(4)(1)(C) or E] Portable pumping unit withplugged emergency pump connection and telemetry - I 5A. NICA.0 02T .0305(h)( I)(C): 1%, It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. • If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stationsstorage capacities and the rotation schedule of the portable power source or pump, including travel timefra.mes, shall be provided i.n the case ofa multiple station power outage. FORM: EFTA 04-16 Page 3 of 5 iX. SETBACKS & SEPARATIONS (02B .0200 & 15A NCAC 02T 5(f 1, Does the project comply with all separations found in 1 1ti A(; 02I O305(fitsJ;g) 15A NCAC 02T,0305(t) contains minimum separations that shall be provided for d er mains v Water mains (h Reclaimed water Setback Parameter* 1 below ater over sewer includirt in benched ontal vertical -, re Reclaimed water lines (horizontal imed over sew **Any private or public water supply source, it eluding any wells, WS-1 waters ofCla.ss T or f drinkinrt water ss ll inrtounded reservoirs used as a sourc **Waters claswsitied WS (except WS-1 or 'WS °), l3, SA, OR;W, HQW, or SB from normal high water (or tide elevation) and wetlands (see item I\.2) **Any Other stream, lake, impoundment, or ground water lowering and surface drainage itches Any tauilding liattndatim An basement Top slope o'cmbanktnent or cuts of 2 Drainage systems and interceptor drains wimmitt t uc arth grad more vertical hei A NcACU21°.0305(g) contains alternatives where separations in 02T 030 ( cannot ani classifications can be identified using the Division's NC Surface Water C"lass 4.ornpliance with 02'F,0305(jZ,ar,(g), see Section X of this application 2, Does the project comply with separation reclttirements for wetlands? (50 feet of separ See the Division's draft separation rccltrirenrents for situations where separation cane No variance IS required if the alternative design criteria specified is utilized in design .. As built documents should reference the location of areas effected 4. Se.aration Re' wired 24 inches l g inches be ac 2 feet 3b inches ved, ns webpage be meet nd construction No CEI Yes D No Does the project comply with all setbacks found in the river basin rules per 17A NC AC 02B ,0200`' ® Yes []' No This would include Trout Buffered Streams per 1.5A.NCAC 213,0202 project comply with an individual 404 Peranit or any 401 Certiticatisan No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can he obtained fr-o.rn the 401 & Buffer Permitting Branch. 5, Does project comply with 1 SA ('C1C. 02`T0105(0(6) (additional permittiYes LJ No Per 1 . NC:"AC. 12'l .0105(0(11 directly related environmental pennies or certi ic^atwn applications are being prepared, have been applied for, or have been obtained„ Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonnwater management plans, etc.). Does this project include any sewer collection lines that are deemed "high -priority`?' Per 1 `A N .' 1C_ dd l.°°,{)402, "high -priority sewer- ans "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to st:reambanks that is subject to erosion that undermines or deteriorates the sewer, No If yes, include an attachment with details for each lirtc, including type (ae High priority lines shall he inspected by the permittee or its representative at least documented per 1:5A NCAC 021.0403(a)(5) or the perntitee's individual System - and location), y six -months and inspections ide Collection permit. ETA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 5A :CAC 02't, the Minimum Desio Criteria for the Permittingof Pum St: hops and Force Mains jlatest version), and the Grayitv SeweryillimiunDesiencriteriajjatestyLersion) as applicable? Yes El No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review, Approval of the request is reuuired prior to submittal of the Fast Track Application and supporting documents. 2„ Professional Engineer's Certification: rvf attest that this application for for 7.,ssional Engineer's name from Application hasbeenreviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the hest of my 'knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria. for Gravity Sewers (latest version), and the .Minimum Design Criteria for the Fast -Track 'Permitting of Pump Stations tnd Force Mains (latest version)„Ahhough other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed 'this material and have judged it to be consistent with the proposed design„ NOTE In accordance with General Statutes 143-21.5„6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed SI 0,000, as well as civil penalties up to 525.000 per violation, North Carolina Professional Engin 's seal, signature, and date: 3: Applicants Certijition, ISA NCAC 02T 06(b): 1^-1 7E C710 A. e. attest that this application for (Signature Authority's 'e & title from Application Item 13:) 4 , has been reviewed by: me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included,. this application package is subject to being -returned as incomplete. 1 undersLand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts. of this application package are not completed and that if all required supporting information and attachments are not. included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes l443-215.6A. and 1,43:-21B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed 510.000 as well as civil penalties up to 125,000 per violation. Signature: va A s Date: q ji .FORM: ETA 04-16 Page 5 of 5 CHARLOTTE W July 15, 2016 Mr. Robert Keidel LandDesign, Inc. 223 N Graham St Charlotte, NC 28202 TER SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE STONEWALL DEVELOPMENT 500-604 STONEWALL STREET, CHARLOTTE NC CLTWATER TRACKING# 2016481 A flow acceptance study of the subject site has been completed and the following has been determined. The review has been set to major/conditional due to capacity concerns at permanent flow monitoring site 30. These concerns are expected to be addressed with the completion of the Upper Sugar Creek Improvements project. The preliminary design for this project is scheduled for 2016, final design is scheduled for 2017, and the current estimate for construction to be completed is sometime in 2018. Additionally, an update to Charlotte Water's sewer model is scheduled to occur in 2016 and is expected to provide a more accurate estimate of sewer capacity in this area and throughout the sewer system. All other associated sewer infrastructure was found to have sufficient capacity to accommodate the proposed sewer flow of 70,538 gallons per day (435 apartment units x 135 gpd/unit; 13,910 ft' amenity center x 50 gpd/100 ft2; 8,522 ft' of retail space x 130 gpd/1,000 ft2; 150 employee office space x 25 gpd/employee) from this project for transmission to the Sugar Creek Wastewater Treatment Plant; NPDES permit number NC0024937, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached NC DEQ flow tracking form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NC DENR. However, CLTWater cannot guarantee a constant pressure or quality of flow. CLTWater does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on aw first come, first served basis.. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. !f the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year o! issuance of this flow acceptance: and payment for any service connection(s) have not been received within (1) year of issuance of this flow acceptance, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Charlotte Water 51 J r rooksh r i d,. ott , , 9 r 'l s mane trewa Operated by the City of C State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: LandDeszgn , rrkc Project Name for which flow is being requested: Stonewall Development More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in.11IGD 99.0 10.452 70.670 0.0705 81.192 82.0% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)—(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf; Daily FIow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 III. Certification Statement: I Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature ofthi form indicates acceptance of this wastewater flow. Signing Of is Signature - Page 2 of 6 d71/17!� Date FTSE 08-13 tgASCAR HOF Si STONEWALL MIXED USE CHARLOTTE, N.C. 2016 4 CHARLOTTE EAST US TOPO 2016 PROJEC Sri„ JECT. Rob Keidel 223 North Graham Street Charlotte, NC 28202 1016055 STONEWALLI AND CALDWELL SITE 1016055 Stonewall Mixed Use Fast Track Sewer Application For Planning tu. NCDENR - Mooresville Regional Office Water Quality Section 610 East Center Avenue Mooresville, NC 28115 v. R,. :ioin coNoE,N ndDesign, Inca Y RANS IT Ai ID 9/12/2016 00012 Overnight rkeidel@landdesign.com Fast Track Sewer Application Package r 704-333-0325 704-663-1699 Corporations Division Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRE TA YOFSTATE. PO Box 29822 Rafet , NC 27iy26-Qd22 t919M7-2O00 Click Here To: Account Login Register View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Legal: NR Stonewall Property Owner LLC Limited Liability Company Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: State of Incorporation: Registered Agent: Corporate Addresses 1491230 Current -Active Current Foreign 1/13/2016 CT Corporation System Reg Office: Reg Mailing: Mailing: Principal Office: 150 Fayetteville St., Box 1011 Raleigh, NC 27601 150 Fayetteville St., Box 1011 Raleigh, NC 27601 575 Fifth Ave 23rd FI New York, NY 10017 575 Fifth Ave 23rd Fl New York, NY 10017 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 570-3-20. https://www.sosnc.gov/Search/profcorp/11960397 9/15/2016 September 12, 016 NCDENR Division of Water Qua Mooresville Regional 0 tfice 610 E. Center Avenue Mooresville, North Carolina 2Sl l RE: Stonewall Mixed Use PN: 1.016055 To Whom it May Co ern: y Enclosed is a Fast -Track Application for Gravity Sewer to serve the project e'ttitled Stonewall Mixed Use. The site is located at the intersection of Stonewall and Caldwell in Uptown Charlotte (Mecklenburg County). It is a mixed -use development consisting of two (2) buildings. The average daily flow for these facilities is 70,538 gallons per day and is being requested in its entirety. Enclosed are one (I) complete application form, one (1) application. fee, one (1) flow acceptance letter, and two (2) site nnapss Please do not hesitate to call if you have any questions or need further information. Thank you, Rob Keidel LandDesign, Charlotte 704.333.0325 1016055 STONEWALLI AND CALDWELL SITE 1016055 Stonewall Mixed Use Fast Track. Application Form For your use Rob Keidel 223 North Graham Street Charlotte, NC 28202 ro NCDENR - Mooresville Regional Office Water Quality Section 610 East Center Avenue Mooresville, NC 28115 Barry, LandDesign, Inc. 9/16/2016 IvQ3, 00015 Second Day rkeidel@a landdesign.com 7 4--333-0325 704-663-1699 Please find the requested original copy of the fast track sewer application for Stonewall Mixed Use. Thanks, Rob Keidel USE THE TAB KEY TO MOVE FROM FIELD TO FIELD owner/Perrnittee la. NR Stonewall Property Owner, LLC Full Legal Name (company, municipality, HOA, utility, etc.) Mike Wilson - Director of Develo men Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized si ApplicationNumber: (to be completed by DWR) lc. The legal entity who will own this system is; Individual 0 Federal 0 Municipality 0 State/County ( 1 d. 1057 East Morehead St. Suite 300 Mailing Address 1f, NC State 1 h. (704) 714-9682 1 i. Telephone Facsimile 2, Project (Facility} Information: 2a, Stonewall Mixed Use Brief Project Name (permit will refer to this name) 3. Cantact Person: 3a, Rob Keidel Name and Affiliation of Someone Who Can Answer Questio ng o Private Partnership 0 Corporation 0 OMV.ri ai 1e Charlotte City l g, 28204 Zip Code MOORESOLLE lja mwilson@northwoodravin.com E-mail 3b. (704) 333-0325 Phone Number Project is New 0 Modification (of an existing per 2b. Mecklenburg County Where Project is Located About this Application 3c. rkeidel4anddei an E-mail difica'tion, Permit No.: Owner is 0 Public (skip to Ito Private go to Item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i,e, store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to item B(3)) © Selling units (lots, townhomes, etc, - go to Item B(2b)) Charlotte Water Owner of Wastewater T 4a, Sugar Creek Wastewater Tre Name of WWTF Charlotte Water fib. 24" Cravity Owner of Downstream Sewer Receiving Sewer Size Force Main gent Facility (W' atment Plant 2b, If sold, cilities owned by a (must choose one) Public Utility (Instruction D) 0 Homeowner Assoc,/Developer (Instruction E) TF) Treating Wastewater From This Project 4b. NC0024937 The origin of this wastewater is (check all that apply): 0 Residential Subdivision Apartments/Condominiums 0 Mobile Home Park 0 School Ci Restaurant Office 15c WWTF Permit No, Permit # of Downstream Sewer (Instruction F) Retail (Stores, shopping centers) 0 Institution 0 Hospital 0 Church ] Nursing Home 0 Other (specify):_ Volume of wastewater to be allocated or permitted for this particular p 'Do not include future flows or previously permitted allocations t'. 70,538 10p % Domestic/Commercial % Industrial (Attach Description) Q/0 Other (Attach Descrirtion) gallons per day 8. If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCACO2T .0303 to determine if a permit is required) FTA 10-14 APPLICATION I'sge 4 of 6 9 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T �0114 for the value in Item B(7) ANDIOR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7), Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data' ff 70,538 GPD = (435 Apartments x 135 GPD per Apartment) + (13,910 sf Amenity x 50 GPD per 100 sf) + (8,522 sf Retail x 130 GPD per 1,000 sf) + (150 Employee Office Space x 25 GPD per Employee) u Size (inches) 10" Lines to be Permitted (attach additional sheets if necessary) Length (feet) 180 New Gravity or Additional Force Main New Gravity Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) z 0 Pump Station Location ID: ( Longitude: Latitude: If chosen - as shown on plans/map for reference) Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator wfATS; GPM @TDH 2 - portable generator wIMTS Force Main Size Force Main Length Pump Station Location 1D: (self chosen - as shown on plans/map for reference Longitude: Latitude: Design Flow Operational Point Power Reliability Option (MGD) GPM e TDhl 1 - permanent generator wWATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12, Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes 0 No If Yes, permit number oaf 2"d treatment facility (RO — if "yes" to 8,12 please contact the Central Office PERCS Unit) Y comply Minimum sign Crit ua fpr the Permrttin cf Pump Stationsand Farce Mains. 13, Does the sewers stem eom I with the Minimum Design (latest version)„ the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter '2 i as applicable'? Yes EJ No If No, complete and submit the Variance/Alternative Design Request (VADC 10-14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. FTA 10-14 APPLICATION Page 5 ot` 6 14, have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Cert'itication? © Yes 0 No N/A Sedimentation and Erosion Control Plan? Yes 0 No 0 N/A. Trout Suffer Waiver? © Yes 0 No NIA Stormwater? ® Yes 0 No © N/A 15_ Does this project include any high priority lines (1 A NCAC 02T .0402 2 involve aerial lines, siphons, or interference manholes)? These lines will be considered high pric rit attg! must be checked once every six months Check if Yes: 0 and provide details: Owner/Permittee's Certification: (Signature of Signing Official and Project Name) t, Mike Wilson attest that this application for NR Stonewall Property Owner, LLC has been reviewed by rrae and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachrnents are not included this application package is subject to being returned as incomplete. Note: In accordance with North Carolina Genera/ Statutes 143-215.6A and 143d215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25 per v ati'on. gning Official Signe a ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY co TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 z 0 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Rob Keidel attest that this application for Stonewall Mixed Use has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge, l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Afth©ugh other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215, aA and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Rob Keidel Professional Engineer Name 2b. Land,Design, Inc, Engineering Firm 2c. 223 N Graham Street Mailing Address 2d, Charlotte City 2g. (704) 333-0325 2 Telephone Facsimile 2e. NC State Zip 2i. rkeidel landdesi n,c E-mail ➢ TA 10-14 Page 6 of"6 Central Files: APS ` SWP _ 9/22/2016 Permit Number WQ0038731 Permit Tracking Slip Program Category Status Protect Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRule Permitted Flow 70,538 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Stonewall Mixed Use Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Nr Stonewall Property Owner LLC Dates/Events Owner Type Non-Govemment Owner Affiliation Mike Wilson 1057 E Morehead St Charlotte NC 28204 Orig Issue 9122/2016 Scheduled App Received Draft initiated Issuance Public Notice Issue Effective 9/14/2016 9/22/2016 9/22/2016 Regulated Activities Requested /Received Events Apartment complex Condominium Office Retail Wastewater collection Outfall Expiration Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin