Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0038480_Regional Office Historical File Pre 2018 (4)
Water Resources E NVNR©NVM,ENTAL. QUALITY May 26, 2016 Jeffrey Smith -- Development Partner Terwilliger Pappas Multi -Family Partners 4777 Sharon Road, Suite 550 Charlotte, NC 28210 PAT MCCRORY DONALD R. VAN DER VAART Secrehlty S. JAY ZIMMERMAN Dxre eor Subject: Permit No. WQ0038480 Terwilliger Pappas Multi -Family Partners Solis Berewick Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Smith: In accordance with your application received May 18, 2016, we are forwarding herewith Permit No. WQ0038480 dated May 26, 2016, to Terwilliger Pappas Multi -Family Partners (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee, It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina f En Y iPtat#uienlal t rtall¢y Water Resources 1 Mooresville Regional OM* 610Rsst Geetee Avenue, Suite 3©1 1 704 663 1699 y 'Regional Operations North Carolina 28115 If you need additional information concerning this matter, please contact or via e-mail at barry.love@ncdenr.gov. bvVKCorey Basinger, RegionalSupervisor Water Quality Regional Operations Section Mooresville Regional Office Division ofWater Resources, NCDEQ cc: ]enamyS. kand, P.E. (e-copy) Barbara Gross Tommy Rowkynd(e-omov Regional Office, Files Water Resources Central Files a Love at (704) 235-2143 Page 2 of 9 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted •to Terwilliger Pappas Multi -Family Partners Mecklenburg County for the construction and operation of approximately 1,621 linear feet of 8-inch gravitysewer to serve 270 apartment units as part of the Solis Berewick project, and the discharge of 36,450 gallons per day of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received May 18, 2016, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump, Stations and. Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified co it'•�s a • i ations contained therein. Fby. W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0038480 Permit Issued: May 26, 2016 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Terwilliger Pappas Multi -Family Partners is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Plant in accordance with Permit Number NC0024970. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted. February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDiTIONS No flow in excess of the quantity permitted herein, 36,450 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] 2. This permit shall become voidable unless the agreement between Terwilliger Pappas Multi -Family Partners and Charlotte Water for the collection and final treatment of wastewater is in full force and effect. [15A NCAC 02T.0304(h)] II. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.5 143-215.1(d3)] This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.01101 This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the Page 4 of 8 I operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: (15A NCAC 02T .0108(b)1: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year), Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)j 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the exiisting utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)) 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. Page 6of8 I c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement -or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field -where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification.' 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria forthe.Fast-Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. 1n°the event .that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST TRACK SEI PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: ENGINEERING CERTIFICATION Terwilliger Pappas Multi -Family Partners WQ0038480 Solis Berewick May 26, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation,. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof.. Printed Name, Title Signature Date ENGINEERS CERTIFICATION I, , as a duly registered Professional En Ineer in the State of North Carolina, having been authorized to observe (�' periodically, fl weekly, Li full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Final 0 Partial (include description) Certification Coents/Qualifiers (attach if necessary): State of North. Carolina p Envirorintental Quality I Water Resources ; Water Quality Re8¢eenal Mooresville'Regional ©1$eei 610 East Center Avenue, Suite 3111 1Mooresvillc, North Caro 704 663 1699 ton$ 28115 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD ...................... Owner!Permittee: Terwilliger Pappas Multi -Family Partners Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Jeffrey Smith - Develment Partner Signing Official Name and Title (Please review 15A NCAC 2T .0 The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ❑ atatefCounty ❑ Pri 0 1 d. 4777 Sharon Road, Suite 550 LL 0 J z 0 2 0 LL Z Mailing Address 11. NC State 1h. 704-716-3906 Telephone 2. Project. (Facility Infor 2a Solis Berewick Brief Project Name (permit will refe 3. Contact Person: 3a. Jeremy (card - Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application Application Number: (to be completed by DWR) )6 (b) for authorized signing officials) ate Partnership t Corporation ❑ Other (specify): 1 e. Charlotte City 1g„ 28210 Zip Code 1j. jsmith@terwilligerpappas.com E-mail 2b, Mecklenbu County Where Project is Located 3b. 704-333-0325 ext.1041 Phone Number Facsimile tion: name 3c. jicard ianddesign.cam E-mail Project is New ❑ Modification (of an existing permit) if Modification, Permit No.: 2. Owner is 0 Public (skip to Item B(3)) Private (go to Item 2(a)) 2a, If private, applicant will be: El Retaining Ownership (i.e. store, church, single office, etc.) or ! i Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction ©) 0 Homeowner Assoc./Developer (instruction E) 3. Charlotte Water Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. McAlpine Creek WWTP Name of WWTF 5a. CharlotteW'at€r 5b. _. 0 Gravity Owner of Downstream Sewer Receiving 6. The origin of this wastewater is (check all ❑ Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park 0 School ❑ Restaurant 0 Office 4b, NC0024970 WWTF Permit No. 5c. 100-04-0000 Sewer Size ❑ Force Main Permit II of Downstream Sewer (Instruction F) that apply): 0 Retail (Stores, shopping centers) ❑ Institution 0 Hospital 0 Church ❑ Nursing Home 0 Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project: 36,450 *Do not include future flows or previously permitted allocations 8 If the permitted flow is zero, indicate why; 100 % Domestic/Commercial Industrial (Attach Description) Other (Attach Descriotion) gallons per day Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit No. ❑, Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) 1'TA 10-I4 APPI..IC:ATION Page 4 of 6 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 27.0114 for. the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). [Units] (270 units x 135 gpd/unit) = 36,450 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" New Gravity or Additional Force Main 1,621 New Gravity z 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Z 0 Pump Station Location ID: (self chosen - as shown on planslmap for reference) V z CL� 0 tL z Longitude: Design Flow (MGD) Latitude: Operational Point Power Reliability Option GPM @TDH 1 - permanent generator w/ATS; Force Main Size 2 - portable generator w/MTS Pump Station Location ID: Force Main Length (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w/ATS; Force Main Size Force Main Length GPMTDN 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? [:] Yes No If Yes, permit number of 2"d treatment facility (RO — if 'yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum De si n Criteria forthe Permittin ,ot Pump Stations and Force Mains (latest version), the Gravit, ,Sewers Minimum Design Cntori (latest version) and 15A NCAC Chapter 2T as applicable? Yes Lj No If No, complete and submit the VariancelAlterna ive Design Request ('VADC 10-14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. FTA 10-14 APPLICATION Page,S 6 14. Hive the following permitslcertifcations been submitted for approval for the system or project to be served? Wetland/Stream Crossings General Permit or 401Certifucation? Sedimentation and Erosion Control Plan? Trout Buffer Waiver? Stormwater? 15. Does this project include any high priority line manholes)? These lines swill be considered Check if Yes: © and provide det 0 Yes ©No ® Yes ©No Yes ©No ©Yes ❑No Ej N/A 0 NA NIA 0 N/A 5ANCtiC 02T"0402L2j) involve aerial lines, siphons, or interference h priority and must be checked once every six months Owner/Pemiittee's Certification: (Signature of Signing Official and Project Name) 1,. Jeff Smith attest that this application for Solis Berhas been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if a!1 required parts of this application are not completed and that if ail required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215, 6A and 143-215. GB, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY t!) TO OTHER UTILITIES,, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 0 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, der e i y ,attest that this application for 5af 5 &rewr ck has been reviewed by me and i§ accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. Jeremy S Icard, PE Professional Engineer Name 2b. Land Design Engineering Firm 2c, 223 N. Graham Street Mailing Address 2d, Charlotte City 2g, 704-333-0325 2h. 704-332-3246 Telephone Facs'imil 2e. NC 2f. 28202 State Zip 2i. jicard landdesign,cam E-mail NC PE Seal, Signature Date FTA 10-I4 APP'UCATION Page 6 of 6 CHARLOTTE W March 10, 2016 Mr, Chris Waldt Land Design 223 N Graham St Charlotte, NC 28082 TER SUBJECT: WATER AND SEWER FLOW ACCEPTANCE SOLIS BEREWICK 9520 SHOPTON ROAD WEST, CHARLOTTE NC CLTWATER TRACKING# 2016196 A flow acceptance study of the subject site has been completed and the following has been determined: Charlotte Water (CLTWater) agrees to accept the gravity sewage flow of 36,450 gallons per day (270 apartment units x 135 gpd/unit) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NC DEQ FTSE form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, CLTWater cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct ermits are not obtained and construction has not started within one issuance of this flow acceptance stud and a rnent for an service connections has not been racowed within (1) year of issuance of this flow acceptance letter, thisapproval shall be rescinded and a clew flo acceptance study must be made. If you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Charlotte Water 5100 Br a kshire Bkv^d, Cha n NC 28216 clharlotteerwate.r.org tad by the City of Charlotte 1z' tto :';i1.7 €' i d4 } .' , Division 07 Water ReSOUM25 State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: LandDesxcm, Inc. Project Name for which flow is being requested: Solis Berewick More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 10.137 69.053 0.036 79.226 50.0% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Beaverdam 2.70 1.08 0.208 0.127 0.336 0.743 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 III. Certification Statement: I J. Carl Wilson certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1 and II plus all attached planning assessment addendums for which I am the responsible party. Signature of t e form Vindicates acceptance of this wastewater flow. A) it. Signing Offi 1 Signature 03 a7 l� Date Page 2 of 6 . FTSE 08-13 Charlotte, N,C, 2013 STREET LEVEL MAP vision of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources hed Classification Attachment (WSCAS 01-15) Along with this form, submit a color copy of a USGS Topographic Map to identify the project area and waterbodies. Each map or maps must show the location of the sewer system and include location identifiers where the system traverses over or near waterbodies. The map should have location ID's for each different waterbody and corresponding classifications should be recorded. Include the completed form and map portions with the permit application for submittal to the appropriate review agency. A list of the Division's regional offices, their county coverage, and contact information can be obtained from: http://partal.ncdenr.or web w borne ro Location ID Name of Waterbody' River Basin Waterbody Index No. Waterbody Classification Beaverdam Creek Catawba 11-126 Beaverdam Creek Catwaba 11-126-1 1 If unnamed, indicate "unnamed tributary to X", where Xis the named waterbody to which the unnamed tributary joins. ! certify that as a Registered Professional Engineer in the State of North Carolina that l have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date NC Surface Water Classification EXGRAVITY—, SEWER April 18, 2016 DWR WQ Classifications EA E DAM CREEK CATAWBA BASIN 126-1 CLASSIFICATIONC -BEAVERDAM CREEK .., CATAWBA BASIN 11,126 CLASSIFtCATION: C 1:18,055 0 0,15 0.3 s r ti 0 0.25 0.5 0.6 mi Souwces: Esri, HERE, Dr'Lorrne#, intexmap, i,crem ri P Core., GEBCO, USGS, FAO, NPS, NRCAN, GeoBase,IGN, Kaeasier NL, Ordnance Sr'ey, Esri Japan„ M€TI, Esn China (Hong Kemp, s isstape, MapmyRrrie, E GpenStreetMepcontributcrs, and the GIS User Gcxnrrundty NCDENR - MvislFon or Water Resources NCDENRDiv. Water Re wrcel city dCfi ar6atf e, Corn N at Gaston State of Noon Camera DOT, Esn, HERE. DeLarmP 1NGRE ME NT P. in errnap. USGS, ME, TGINASA, EPA, USDA NCOENR • Diviser alWeler Reseueces h -March 24, 2016 ENGINEER'S REPORT Solis Berewick LDI Project No. I015388 SEWER SYSTEM APPLICANT: Terwilliger Pappas Multi -Family Partners 4777 Sharon Road, Suite 550 Charlotte, NC 28210 DEVELOPER: Terwilliger Pappas Multi -Family Partners 4777 Sharon Road, Suite 550 Charlotte, NC 28210 DESCRIPTION: The site consists of approximately 13.3 acres. The property is zoned CC-LLWPA and will consist of 4 apartment buildings with a total of 270 apartments. We are proposing to install approximately 1,621 If of 8" pvc sewer main on -site that will make up the private system. Flows from the site will be sent to the McAlpine Creek Wastewater Treatment Plant (NPDES permit number NC0024970). DEMAND: The proposed demand for this site will be approximately 36,450 gallons per day. The demand is based on 270 apartment units at 135 gallons per day/unit. New mains are expected to have a minimum 50-year service life. The system will be constructed by the Developer per Charlotte -Water standards and specifications and services will be billed by the City of Charlotte in accordance with their standard rate schedule. Information on the existing City system operational procedures and capabilities are contained in the Charlotte Mecklenburg Water System Management Plan (WSMP #05-01702 & PWS ID #0160010). 'March 24, 2016 ENGINEER'S REPORT Solis Berewick Lill Project No. 101538E SEWER SYSTEM APPLICANT: Terwilliger Pappas Multi -Family Partners 4777 Sharon Road, Suite 550 Charlotte, NC 28210 DEVELOPER: Terwilliger Pappas Multi -Family P 4 777 Sharon Road, Suite 550 Charlotte, NC 28210 DESCRIPTION: The site consists c 'approximately 13,3 acres, The property is zoned CC-LLMPA and will consist of 4 apartment buildings with a total of 270 apartments. We are proposing to install approximately 1,621 If of 8" pvc sewer main on -site that will make up the private system. Flows from the site will be sent to the McAlpine Creek Wastewater Treatment Plant (NPDFS permit number NC0024970). DEMAND: The proposed demand for this ite will be approximately 36,450 gallons per day. The demand is based on 270 apartment units at 135 gallons per day/unit. New mains are expected to have a minimum 50-year service life. The system will he constructed by the Developer per Charlotte -Water standards and specifications and services will be billed by the City of Charlotte in accordance with their standard rate schedule. Information on the existing City system operational procedures and capabilities are contained in the Charlotte Mecklenburg Water System Management Plan (WSMP #05-01702 & PWS ID #0160010). 1015388 SOLIS BEREWICK MULTI -FAMILY 1015388 Fast Track Sewer Application For your use Gurveer Uppal Land Design. Barry Love 610 E Center Ave #301 NCDENR - Room # 3323 Mooresville Regional Mooresville NC 28115 Office United States Barry, 5/17/2016 00017 Courier guppal@landdesign.com x10"2 barry„love@ncdenr„gov Attached is the updated sewer application for the Solis Berewick projec Please email me if you have any questions or require additional information. Ct,t" e (signer sninLtof DC„. 1 DeiWasj Orlando (OandDesigplr c 7/2016 NCDEQ fast track 2nd submittal.pdf Jeremy Icard Franc Corporations Division Page 1 of 1 North Carolina E/sins F MMrsha!! DEPARTMENT OF THE Secretary ..:SECRE C' RY OF STATE PO Box 29822 Ra(el ,. NC 276264322 (9'f93E97-2O0 Click Here To: Account Login Register View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Legal: Terwilliger Pappas Multi -Family Partners, LLC Limited Liability Company Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: State of Incorporation: Registered Agent: Corporate Addresses 1300907 Current -Active Current Domestic 2/7/2013 December NC Pappas, Peter A. Mailing: Principal Office: Reg Office: Reg Mailing: 4777 Sharon Road, Suite 550 Charlotte, NC 28210-0101 4777 Sharon Road, Suite 550 Charlotte, NC 28210-0101 4777 Sharon Road, Suite 550 Charlotte, NC 28210-0101 4777 Sharon Road, Suite 550 Charlotte, NC 28210-0101 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Member: Managing Member : J. Ronald Terwilliger Revocable Trust 3060 Peachtree Road, Suite 830 Atlanta GA 30305 Peter A. Pappas Revocable Trust 4777 Sharon Road, Suite 550 Charlotte NC 28210 https://www.sosnc.gov/Search/profcorp/10169865 5/19/2016 Central Files: APS _ SWP 5/26/2016 Permit Number WQ0038480 Permit Tracking Slip Program Category Status Non -discharge Active Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuie Permitted Flow 36,450 Facility Project Type New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name MajorlMlnor Region Solis Berewick Minor Mooresville Location Address Facility Contact Affiliation Owner County Mecklenburg Owner Name Terwilliger Pappas Multi -Family Partners Dates/Eve nts Owner Type Non-Govemment Owner Affiliation Jeffrey B. Smith 4777 Sharon Rd Charlotte NC 28210 Orig Issue 5/26/2016 App Received Draft Initiated 5/18/2016 Scheduled Issuance Public Notice Issue Effective 5/26/2016 5/26/2016 Regulated Activities Requested !Received Events Apartment complex Wastewater collection Outfall Additional information requested Additional information received Expiration Waterbody Name Streamlndex Number Current Class Subbasin Water Resources Environmental Quality May 8, 2017 Jeffrey Smith, Development Partner Terwilleger Pappas Multi Family Partners 4777 Sharon Road, Suite 550 Charlotte, NC 28210 SUBJECT: Final Engineering Certification. Acknowledgement Project: Solis Berewick Permit No. WQ0038480 Permittee: Terwilliger Pappas Multi -Family Partners County: Mecklenburg Dear Mr. Smith: ROY COOPER MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on May 3, 2017. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance.. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://portal.ncdenr.org/web/wq/swp/ps/cs/pnoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Jeremy S. Icard, P.E., ndDesign, 223 N. Graham. Street, Charlotte, NC 28202) Central Files MRO "Nothing Compares, - .. State of North Carolina 1 Environmental Quality p Water Resources J Wager Quality' Regional Operations Mooresville Regional office { 610 East Center Avenue, Suite 301 p Mooresville, North Carolina 28115 704-663-1699 Pr' FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: Terwilliger Pappas Multi -Family Partners PERMIT tt; W00038480 PROJECT: Solis Berewick ISSUE DATE; May 26, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PER"IITTEES CERTIFII ATION I the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name. Title Signa ENGINEERS CERTIFICATION Jeremy S !card as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe (j periodically, weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1SA NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimurn Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials, North Carolina Professional Engineer's Seal w/signature & date: Final Partial (include description) Certification Comments/Qualifiers (attach if necessary): 02 May 2017 6 htlty l w a r Resources' Water Quality Regional Operatlom enter Avenue, Suite 3011 Mooresville, Nooti Carolina 28115 704 663 1,699 1015388 SOLIS BEREWICK MULTI -FAMILY 1015388 Solis Berewick Private Wastewater Collection System Final Certification (WQ0938480) 5/2/2017 00049 For your use and distribution Courier Barrett Blackburn Barry Love 610 E Center Ave #301 NCDENR Room # 3323 Mooresville Regiona Mooresville NC 28115 Office United States Barry, BBlackburn@la ddesign.com barryaove@ncdenr.gov Please find the attached submittal package as our final certification for Solis Berewick Private Wastewater Collection System. Let us know should you have any questions, Thanks,. Barrott Brackbittn, Designer [ Office on DC; ando j San Francesco 5/2/2017 Solis Berewick Pvt S S Certification Submittal-95-t12- 2©17.pdf CREATING PLACES THAT MATTER. May 2, 2017 Mr. Barry Love NCDEQ Mooresville Regional Office 610 East Center Ave, Suite 301 Mooresville, NC 28115 Re: Wastewater Collection System Extension Terwilliger Pappas Multi -Family Partners Solis Berewick Mecklenburg County Permit Number: WQ0038480 LandDesign PN: 1015388 Dear Mr. Love, MOo ES La,... On behalf Twilliger Pappas Multi -Family Partners, we are providing herewith inspection reports, as built survey, and a final certification for the Wastewater Collection System to serve Solis Berewick, located in Charlotte, NC.. This final certification package is being submitted to certify the construction and completion of the Solis Berewick sanitary sewer collection system under the fast track permit number WQ0038480, The project consisted of approximately 1,621 LF of 8" gravity sewer to serve 275 apartment units as part of the Solis Berewick project. Construction of this system was observed and built within compliance of the permit. Feel free to give me a call if you have any questions. Respectfully Submitted, Barrett Blackburn LandDesign, Inc. LANDDESIG.N,.COM 23 N GRAHAM I:PEET 3 H:Ai L. "T L',< Hi E: 3 3w LLL SAN irRA.,yNs ESC0 Sanitary Sewer Testing Report Project Name: SOLIS Berewick Date: February 2017 Signed: William Morris Manhole Location SSMH-9 to SSMH8 SSMH-8 to SSMH-7 SSMH-7 to SSMH-6 SSMH-6 to SSMH-13 SSMH-5 to SSMH-6 SSMH-4 to SSMH-5 SSMH-11 to SSMH-10 SSMH-11 toSSMH12 SSMH-4 to SSMH-3 SSMH-4 to SSMH-3 SSMH4 to SSMH-3 SSMH-4 to SSMH-3 Pipe Size 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch 8 inch Pipe Length 107.93 94,66 95 5 218,26 162 74 221,26 50.33 311 8 78.24 66,48 66.99 10 Mandrel Test Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Present at Site: William Morris- LDI Low Pressure Air Test Time(Minutes) 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes 4 psi for 4 minutes Comments Users\ bblackburnAppDatakLocahMicrosoft‘WindowsVNeiCache\Cor)tent.1 lc k. Sewer testing 4:03 PM 5/2/2017