Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0038291_Regional Office Historical File Pre 2018
Water Resources ENVIRONMENTAL QUALITY February 23, 2016 Mr. Martin Lashua — Vice President of Operations Carolina Water Service, Inc. of NC P.O. Box 240908 Charlotte, NC 28217 Dear Mr. Lashua: PAT MCCRORY Governor DONALD R. VAN DER VAART Secr oary S. JAY ZIMMERMAN IJrrec.inv Subject: Permit No. WQ0038291 Carolina Water Service, Inc. of NC Lancaster (Highway Mixed -Use Wastewater Collection System Extension Permit Mecklenburg County In accordance with your application received February 11, 2016, we are forwarding herewith Permit No. WQ0038291 dated February 23, 2016, to Carolina Water Service, Inc. of NC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina j Ent Mooresville Regional Offic mental Quality I Water Resources I Water Quality Regional Operations 0 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 Ifyou need additional information concerning this matter, please contact Barry Love atL7O4\235-2149 or via e-mail at barry'.love@ncdenr.gov. Sincerely, bvVV.Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division ofWater Resources, NCDECi cc: Matt Bramwell, P.E. (e-copy) Barbara Gross (»+copy) Tommy Rowland (e'couv) Regional Office Files Water Resources Central Files Page 2 of 8 Environmental. Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other. applicable Laws, Rules, and Regulations, permission is hereby granted to Carolina Water Service, Inc. of NC .Mecklenburg County for the construction and operation of approximately 249 linear feet of 8-inch gravity sewer to serve 26 apartments and office/mixed space as part of the Lancaster Highway Mixed -Use project, and the discharge of 12,240 gallons per day of collected domestic wastewater into the Carolina Water Service, Inc. of NC existing sewerage system, pursuant to the application received February 11, 2016, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. by W. Corey Basiner,'Regional pervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0038291 Permit Issued: February 23, 2016 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Carolina Water Service, Inc. of NC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Carolina Water Service, Inc. of NC, Lamplighter Village South Wastewater Treatment Plant in accordance with Permit Number SC0030112. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 12,240 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] II. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved, [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: Page 4 of 8 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related' sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current. Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting. documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Page 6 of 8 Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the'Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10, Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T'.0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE:. Carolina Water Service, Inc. of NC WQ0038291 Lancaster Highway Mixed -Use February 23, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I , as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe (E periodically, weekly, [ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Q Final [' Partial (include description) Certification Comments/Qualifiers (attach if necessary): State of North Carolina awn - Mooresville Regional Ot i'cel "Ti7Ca1 Quality I Water Resources Water Quality Regi mal Operations East Cener Avenue, Suite 301 I Moorreavillc, North Carolina 28115 0 LL 0 TAB KEY TO MOVE PROSE FIELD TO FIELD Owner/Permittee: la. Carolina Water Service, Inc, of NC Application Number: (to be complete' by DWR) Full Legal Name (company, municipality, HOA, utility, etc., 1 b. Martin Lashua - Vice President of O orations Signing Official Name and Title (Please review 15A) GAC 2T at 13 i authorized signing officials) lc. The legal entity who will own this system is: Individual ❑ Federal ❑ Municipality ❑ State/County ❑ Private Partnership ld, P.O. Box 240908 Mailing Address NC State 1 h. 704-525-7990 704-525-8174 Telephone Facsimile 2. Project (Facility) Information: 2a. Lancaster Highway Mixed -Use e. Charlotte City 1g, 28217 Zip Code 1 j. mjlashua uiwater,com Corporation ❑ Other E-mail 2b. Mecklenburg County Where P Brief Project Name (permit will refer to this name) roject is Located 3. Contact Person: • 3a. Martin Lashua - Vice President of Operations Name and Affiliation of Someone Who Can Answer Cuestlens About this Application z z 3b. 704-319-0517 Phone Number Project is ® New ❑ Modification Owner is Public (skip to Item 8(3) 2a. If private, applicant will be: ❑ Retaining Ownership (Le, store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc, - skip to Item 8(3)) D Selling units (lots, townhomes, etc. - go to item B(2b)) an existing permit 3c. mjlashua E-mail cation, Permit No,: ater.com Ej Private (go to Item 2(a)) Carolina Water Ser rice, Inc, of NC Owner of Wastewater Treatment Facility (WI 4a. Lam hter Village South (a.k.a. Denby) Name of WWTF 5a. CW S of NC Owner of Down ea TFI Treatin i5b. 8" Sewer ;Receiving Sewer Siz. 6. The origin of this wastewater is (check all that apply): 0 Residential Subdivision Apartments/Condominiums Mobile Home Park ED School ❑ Restaurant Office 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction 0) ❑ Homeowner Assocn/Developer (Instruction E) ater From This Project 4b. SC0030112 WWTF Permit No, Gravity 5c. 15025 (9/1/1981) Force Main Permit # of Downstream Sewer (Instruction F Retail (Stores, shopping centers) Institution Hospital ❑ Church Ej Nursing Home ❑ Other (specity):r Volume of wastewater to be allocated or permitted for this particular project: 12,240 "Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 100% Domestic/Commercial % Industrial (Attach Description % Other (Attach Description) gallons per day ❑ Pump Station, Outfali or interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see15A NCAC 02T.0303 to determine if a per is required) \Pt'LICA'FIt3N 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 21 ,.0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7), Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). [(7) 1 bedroom + (17) 2 bedroom apartments] x 240 gallons per day = 5,760 gpd (2) 3 bedroom apartments x 360 gpd = 720 gpd 16 single family equivalents (office/mixed use space) X 360 gpd per single family equivalent = 5,760 gpd Total Capacity 12,240 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8" Length (feet) New Gravity or Additional Force Main 249 GRAVITY LLB 11, Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) 2 0 Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: 0 0 Design Flow Power Reliability Option Operational Point (MGD) GPM @TD11 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow (MGD) Power Reliability Option Operational Point 1 GPM @TDH - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12, Will the wastewater flow in the proposed sewer ines or pump stations be able to be directed to another treatment facility? ID Yes No If Yes, permit number of 2i'd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Malimum Dugs Criteria tor the Pelititting Qt, Pump Stations and Forcp,, tyVoips (latest version), the Grav4y.5ewer Minimum Design Critena (latest version) and 15A NCAC Chapter 2T as applicable? Yes No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 1rA 08-.13 APPLICKHON Page 5 of o 0 14. Have the following permits/certifications been submitted for approval tor the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? Yes ❑ No © N/A Trout Buffer Waiver? ❑ Yes [] No N/A Stormwater? Yes ❑ No ❑ N/A 15. Does this project include any high priority lines ("j5A NQAC 02T .040212_1) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details: N/A Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Martin Lashua, Vice President of Operations attest that this application for Lancaster Highway Mixed -Use has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 1,413-215„6A and i43-215,68, any person ho kn+»,; inglymakes any false statement, representation, or certification in any application shall be guilty of Cfa -'.` mis+ ea •rg which may include a fine not to exceed $10,000 as well as civil penalties up to $25„000 per viola i Signing Official Signature 5/2 0 / Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY; TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15ANCfAt; 02T 0305 Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Matt Bramwell ,attest that this application for Lancaster Highway Mixed -Use has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fest-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note.' In accordance with NC General Statutes 1 13-2 tt 5 nb 4 and 1 t3-215 oft, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. Matt Bramwell Professional Engineer Name 2b. LandDesign Engineering Firm 2c, 223 North Graham St Mailing Address 2d. Charlotte 2e. NC 2f. 28202. City StateZip.�_. 2g, 704-333-0325 21, Telephone Facsimile 2i. rnbramwelllanddesign com E-mail NC PE Seal, Sig rsi Lure & Date )8-1.3 ,rAPP1.A(:A'l`lt,)N SITE --EXISTING SEWER ---PROP„ PRIVATE SEWER PROP, PUBLIC SEWER 1-27-2016 Lancaster Highway Mixed -Use FAST -TRACK APPLICATION SITE MAP 07/1.1/95 11:1.1 129197334535 P1°13LIC AFF .4+ CWQS DANIEL TO WHOM IT MAY CONCERN NORTH CAROLIN a► PUBLIC STAFF UTILITIES COMMISSION July ia, 1995 Re: Danby Subdivision Woodside Village Subdivision Woodside Falls Subdivision Winghurst Subdivision The Strathmoor Subdivision This letter is to certify that Carolina Water Service of North Carolina has been granted a Certificate of Public Convenience and Necessity to provide water/sewer service in the Lamplighter Village South in Mecklenburg County, North Carolina, under Docket No. W-354, Sub 41. The above subdivisions are contiguous extension of the Lamplighter Village South Subdivision. A contiguous extension of a Franchised system does not require an additional franchise. If we can be of further assistance to you, please do not hesitate to contact this office. Sincerely, Andy Lee, Public Staff RL:sw Executive 'Director Cuoimunrcatiunr 7311435 7)3.2510 Acoe mine Consume' Services Electra 733-4179 7)3.9277 733-!267 M7* turtrt 7314326 ion Trarusprsnotion 713.7766 Water 733.5610 P.O. Dor 29520 • Raleigh, North Camttn 276.1.6.0520 • Fax k 79 733-956S A1nEqual Oppostunlrr if Air mAt,vaAct WnFIN/107r7 O7/14/9 12:11. 4 91973395.05 .�., CWS DA 4IEL 01/001 NORTH CAROLINA. ISL1c STAFF UTILITIES COMMISSION July 14, 1995 TO WHOM IT MAY CONCERN Re: Denby Subdivision Woodside Village Subdivision Woodside Falls Subdivision Winglwurst Subdivision The Strathmoor Subdivision This letter i s to certify that Carolina Water Service of North Carolina has been, granted a Certificate of Public. Convenience and Necessity to provide water/sewer service in the lamplighter Village South in MecklenburgCounty, North Carolina, under Docket No., W-354, Sub 41, The above subdivisions are contiguous extension of the Lamplighter Village South Su* ivision. A contiguous extension of a franchised system does not require an additional franchise. If we can be of further assistance to you, please do not hesitate to contact this office. AL:sw Executive Diretmr 7 3I-'2435 Accounting 7314179 Sincerely, Andy Public Staff -'Water Divi ion €etetelMruc Research 733-2902 Consumer Services 713,927 i Legal Transports¢k,ei 733A61u4 733•7766 RlacuralGas Watt 7.33.4326 733.5610 PC3, BO'K 29520 • Raleigh, N'us + AtuEalun:°protwkniry, Af6*m,UA'ae L;r 20 • 14x(919)733.9565 lever Jarauary 2L 201.6 Re: Southern Apartment Group-Ballantyne LLC "14732 Lancaster Highway" Project, Pineville NC Sanitary Sewer Capacity - up to a maximum, of 1.2,2.4f} gallons per day Receiving WWTF — Lamplighter Village South (a,k.a. "Da rsby") Wastewater Treatment Plant Receiving WWTP permit — SC0030112 To Whon3 It May Concern, Carolina Water Service, Inc. of North Carolina is a franchised and regulated public utility providing sanitary sewer service to the Danby/Lamplighter South/Woodside Falls/Winghurst and other subdivision area off Lancaster Highway south of Pineville in Mecklenburg County, North Carolina. Our service area is adjacent and contiguous to the above referenced project. Please accept this letter as official flow acceptance as referenced above. Carolina Water Service Inc. of North Carolina. ng and able to receive the flow for this project through our collection system and treatment facility once infrastructure construction has been satisfactorily completed to our requirements and connection fees received.. yo Sin -ed. additional information, please con ...ashua Vice President of ()per t 704-319-0517 or by email crt n��l isi A abates. 1pany Cardin later Service,. Inc. of North Carolina fax 240908 s Charlotte, NC 28224 F: 704µ525-7990 o F: 704-525-8174 5701 Westpark Dr,, Smite 101 Charlotte, INC 28217 s www.uiwater.com January 21, 2016 Re: Southern Apartment Group-Ballantyne LLC "14732 Lancaster Highway" Project, Pineville NC Sanitary Sewer Capacity - up to a maximum of 12,240 gallons per day Receiving WWTF — Lamplighter Village South (a.k.a. "Darby") Wastewater Treatment Plant Receiving WWTP permit— SC0030112 To Whom It May Concern, Carolina Water Service, Inc. of North Carolina is a franchised and regulated public utility providing sanitary sewer service to the Danby/Lamplighter South/Woodside Falls/Winghurst and other subdivision area off Lancaster Highway south of Pineville in Mecklenburg County, North Carolina. Our service area is adjacent and contiguous to the above referenced project. Please accept this letter as official flow acceptance as referenced above. Carolina Water Service Inc. of North Carolina is willing and able to receive the flow for this project through our collection system and treatment facility once infrastructure construction has been satisfactorily completed to our requirements and connection fees received. If you need additional information, please contact me at 704-319-0517 or by email at rnjlashua@uiwater.com, Vice President of Operations A P.0, '• ix 240908 it 5701 Wes1patk Carolina Water Service, Inc. of North Carolina tie, NC 28224 / P: 704.525-7990 • F: 704-525-8174 ate 101 s Charlotte, NC 28217 s www.uivrater,com V: [7‘if\ Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Carolina Water Service, Inc. of North Carolina Project Name for which flow is being requested: Lancaster Highway Mixed -Use More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Lamplighter Village South WWTP b. WWTP Facility Permit #: SC00430112 All flows are in MGD c. WWTP facility's permitted flow 0.500 (plant in service) d. Estimated obligated flow not yet tributary to the WWTP 0.008 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 0.238 (1/15 to 12/15) 0.012240 0.258 51.6% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) Design Obligated, Pump Average Daily Approx. Not Yet Station Firm FIow** Current Avg. Tributary (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Number) MGD MGD MGD MGD Danby WWTP LS (D)=(B+C) (E)=(A-D) Total Current Flow Plus Obligated Available Flow Capacity*** 0.792 0.3168 0.238 0.02024 0.25824 0.05856 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 Certification Statement: l Martin Lashua certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station. en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning asses ent addendums for which I am the responsible party. Signature of this form indicates accepta `e of leis watewat grzature urban design planning civil engineering branding landscape architecture February 10, 2016 Mooresville Regional DENR Office Division of Water Quality 610 E. Center Ave. Mooresville, NC 28301 RE: Lancaster Highway Mixed -Use LandDesign PN: 1015061 Dear Sir/Madam, Notion Properties is proposing to develop a mixed -use development on a 3,62 acre tract. The parcel will be divided into two office and one multi -family parcels respectfully, We are estimating 12,240 gallons per day of gravity sewage. Attached is a letter from Carolina Water Service, Inc. of North Carolina agreeing to accept our flows to the Lamplighter Village South WWTP. The sewer system contains 249 L.F, of 8" PVC. The public 8" PVC system will be connecting a proposed 8" private line to an existing 8" system within Latour Court. Included in this submittal is 2 copies of the Fast -Track Application form, $480 Application fee check, , Downstream Sewer WWTF Capacity and Flow Tracking/Acceptance forms, Color Site Map and Certifications, Thank you for your assistance with this project, please feel free to contact me at 704.376.7777 or mbramwellAlanddesinn.com should you have any questions and/or comments. Respectfully Submitted, Matt Bramwell, PE, LandDesign, Inc. PO Box 36959 Charlotte, NC 28236-6959 223 North Graham Street Charlotte, NC 28202 V:704.333.0375 F.704.376.82 NN 2Oli',I✓JI506 \DocsyPe siat8in 1 nni Fonns Public San 1015061 LANCASTER HIGHWAY MIXED USE 1015061 Lancaster Highway Mixed -Use Development For your review and comment Land Design Barry Love 610 E Center Ave #301 NCDENR - Room # 3323 Mooresville Regional barry.iove©ncdenr.gov Mooresville NC 28115 Office United States 2/10/2016 00017 Overnight ELemieux©landdesign,com Ba rry, Attached is our public sewer permit submittal for the Lancaster Highway Mixed -Use project located south of Pineville in Mecklenburg County, NC. Thank you, Eric Lemieux Cover Letter 2 Fast Track Application (1 original and 1 copy) 1 -- $480 Application Fee Check 1 Flow Acceptance Form 1- Color Site Map 1 - Utility Plan 2 -- Certificate of Public Convenience and Necessity 2 -- Flow Acceptance Letter 1 - Flow Tracking/Acceptance Forrn (FTSE 08-1 Matt Bramwell Transmittal DATE: 2/10/2016 TRANSMITTAL ID: 00017 Page 2 of 2 r.. Central Files: APS ^ SWP _ 2/22/2016 Permit Number WQ0038291 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 12,240 Facility Version A Permit Classification Individual Permit Contact Affiliation Facility Name Lancaster Highway Mixed -Use Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Carolina Water Service Inc of NC Dates/Events Owner Type Non -Government Owner Affiliation Martin J. Lashua PO Box 240908 Charlotte NC 28224090 Orig Issue 2/23/2016 App Received Draft Initiated 2/11/2016 Scheduled Issuance Public Notice Issue Effective Expiration 2/23/2016 2/23/2016 Regulated Activities Requested !Received Events Apartment complex Condominium Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin RCEIV FAST TTRACK SEWER ENGINEERING CERTWFfCATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Carolina Water Service, Inc. of NC WQ0038291 Lancaster Highway Mixed -Use February 23, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERM' °I EE'S CERTIFICATION 1, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Perrnittee, and the Perrnittrt s prepared to operate & maintain the wastewater collection system permitted herein or port ict^ they J Bryce Mendenhall, VP of Operations Printed Name, Title June 9, 2020 gnature Date ENGINEER'S CERTIFICATION I, Nate Do01-tile , as a dui registered Professional En ineer in the State of North Carolina, having been authorized to observe (periodically, [1 weekly, jj full time) the construction of the project name and location as referenced above for the above Perrnittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1SA NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 21000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date. n Final Q Partial (include description) 0 8:49 AM cu Certiftcaltion Comments/Qualifiers (attach if necessary): State of North Carolina Environmental Quality I Water Resources Water Quality Regional Operations Mooresville Regional Office' 610 East Center Avenue, Smite 301 1 Mooresville, North Carolina 28115